Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

Chint CJX2-9511 AC Contactor - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

contacteur/

Chint CJX2-9511 AC Contactor

Model SegmentSignification
CJX2Chint AC contactor series code (equivalent and compatible with Schneider LC1D series)
95Rated operating current of 95A (under AC-3 utilization category at 400V)
11Configuration des contacts auxiliaires: 1 Normalement ouvert (NON) + 1 Normalement fermé (Caroline du Nord)

  • Détails du produit

Core Positioning: The Chint CJX2-9511 is a 3-pole Contacteur CA with a rated current of 95A, equipped with 1 normalement ouvert (NON) + 1 normalement fermé (Caroline du Nord) contact auxiliaire. It is suitable for AC 50/60Hz circuits, mainly used for remote switching on/off of circuits, frequent starting and control of three-phase AC motors. It can be combined with a thermal overload relay to form an electromagnetic starter for overload protection.

  1. Interprétation du modèle
Model SegmentSignification
CJX2Chint AC contactor series code (equivalent and compatible with Schneider LC1D series)
95Rated operating current of 95A (under AC-3 utilization category at 400V)
11Configuration des contacts auxiliaires: 1 Normalement ouvert (NON) + 1 Normalement fermé (Caroline du Nord)
  1. Paramètres techniques de base
Élément de paramètreSpecification Details
Contactor TypeAC coil contactor, 3-pole main contacts + 1NON + 1NC auxiliary contacts
Tension de fonctionnement nominaleCircuit principal: AC 50/60Hz, up to 690V
Courant de fonctionnement nominal95A at AC-3, 400V; 132A at AC-1, 400V
Coil Voltage OptionsAC 24V/36V/110V/220V/380V, compatible with 50/60Hz
Coil Power ConsumptionPull-in power approx. 1800Virginie, holding power approx. 180Virginie
Tension d'isolation nominale800V (complies with IEC 60947-4-1 standard)
Tension de tenue aux impulsions nominale8kV
Durée de vie mécaniqueEnviron 10 millions d'opérations
Durée de vie électriqueEnviron 1 million operations at AC-3, 400V, 95UN
Rated Operating FrequencyJusqu'à 1200 operations per hour (AC-3 utilization category)
Control Circuit VoltageCoil voltage range: 85%~110% of rated voltage
Méthode de montageDIN rail mounting (35mm standard rail) or screw fixing
Méthode de câblageDouble-hole terminal blocks, main circuit applicable wire cross-section: 16~35mm²
Température de fonctionnement-5°C ~ +40°C (can reach +40°C when relative humidity ≤50%, derating required at higher humidity)
Classe de protectionIP20 (protects against finger contact and solid foreign objects with diameter ≥12mm)
PoidsApproximately 1.2kg

III. Caractéristiques fonctionnelles

  1. High Compatibility Design: Same dimensions as Schneider LC1D series, directly interchangeable, compatible with various functional accessories
  2. High-efficiency Energy-saving Coil: Adopts high-quality electromagnetic materials, pull-in/holding power ratio up to 10:1, with significant energy-saving effect
  3. Plusieurs mécanismes de protection:

Built-in overvoltage suppressor in the coil to extend coil service life

Main contacts made of silver alloy material, résistant à l'arc et anti-soudure, improving reliability

Dust cover design, adapté aux environnements industriels difficiles

  1. Flexible Wiring System: Double-hole terminal block design, more secure wiring, reducing loosening risk
  2. Large adaptabilité de tension: Wide coil voltage range (85%~110%), adapting to power grid fluctuations
  3. Easy Installation: Standard DIN rail mounting, space-saving and convenient for quick replacement
  4. Champ d'application

The CJX2-9511 contactor is suitable for the following industrial scenarios:

  1. Contrôle du moteur:

Direct start/stop control of three-phase asynchronous motors (approx. 45kW at 380V)

Control of continuous operation equipment such as fans, water pumps and compressors

Control of frequent starting equipment such as conveyors and mixers

  1. Electrical Control Systems:

Remote switching on/off of circuits in power distribution systems

Control of electric heating equipment and lighting systems

Combined with thermal overload relays (par ex., NR2 series) to form electromagnetic starters for overload protection

  1. Automatisation industrielle:

Executive component of PLC control systems

Bypass contactor for soft starters and frequency converters

Electrical control of machine tools, printing machinery and packaging equipment

  1. Recommandations de sélection

5.1 Key Selection Points

Selection FactorRecommended Considerations
Type de chargeSelect AC-3 rated current for motor loads; select AC-1 rated current for resistive loads
Correspondance de puissanceCan control ≤45kW three-phase asynchronous motors at 380V (AC-3)
Tension de bobineSelect according to control circuit power supply (220V/380V commonly used, 24V/36V/110V optional for special occasions)
Contacts auxiliaires1NO+1NC meets basic control needs; auxiliary contact modules can be added for more contacts
Fréquence de fonctionnementFor frequent operation (>600 times/hour), derating is recommended or special high-frequency contactors should be selected
Conditions environnementalesFor high-temperature, humid and dusty environments, derating or protection class upgrade should be considered

5.2 Modèles alternatifs et compatibilité

Alternative ModelMarqueDifference DescriptionCompatibilité
NXC-9511Chint (Kunlun Series)Upgraded version of CJX2 series with improved performance and compatible dimensionsEntièrement compatible, can be directly replaced
LC1D9511SchneiderOriginal design with consistent performanceInstallation and electrically compatible, interchangeable
TGC1-9511TengenSame specification product with more competitive priceInstallation compatible, consistent functions
CJX2-9501/9510ChintDifferent auxiliary contact configurations (01: 1Caroline du Nord; 10: 1NON)Consistent main circuit parameters, different auxiliary contacts

5.3 Recommended Supporting Products

  1. Relais de surcharge thermique: NR2-93 (setting current 63~93A), directly pluggable with CJX2-9511 to form an electromagnetic starter
  2. Protection contre les surcharges: Motor protectors (par ex., JD-5) can be optionally configured for more comprehensive protection
  3. Auxiliary Contact Expansion: Auxiliary contact modules such as F4-11 and F4-22 to increase the number of contacts
  4. Surge Suppression: RC snubber or varistor to protect coils and contacts
  5. Troubleshooting Guide

6.1 Défauts courants et solutions

Phénomène de défautCauses possiblesÉtapes de dépannage
Contactor fails to pull in1. Coil not powered; 2. Low coil voltage; 3. Burned coil; 4. Mechanical jamming1. Check control circuit power supply and wiring; 2. Measure coil voltage (should be ≥85% of rated value); 3. Measure coil resistance with multimeter (normal value approx. several hundred ohms); 4. Check if iron core is jammed and remove foreign objects
Loud noise after pull-in1. Oil/dust on iron core end face; 2. Broken shading coil; 3. Low coil voltage1. Clean iron core end face; 2. Check shading coil (replace iron core if broken); 3. Adjust coil voltage to rated range
Contact overheating/ablation1. Overload operation; 2. Poor contact connection; 3. Arc suppression failure1. Check load current and replace with contactor of larger capacity; 2. Clean contacts and replace if severely ablated; 3. Check arc chute and ensure it is intact
Poor auxiliary contact connection1. Contact oxidation; 2. Spring fatigue; 3. Câblage lâche1. Clean contacts; 2. Replace auxiliary contact module; 3. Tighten wiring terminals
Coil burnout1. Excessively high voltage; 2. Frequent starting; 3. High ambient temperature1. Check power supply voltage and install overvoltage protection; 2. Reduce starting frequency or select high-frequency contactor; 3. Improve ventilation and lower ambient temperature

6.2 Contactor Status Judgment

Article d'inspectionNormal StatusAbnormality Judgment
Coil ResistanceApprox. 300~800Ω (depending on coil voltage)Resistance of 0 (court-circuit) or infinity (open circuit) is abnormal
Main Contact Voltage Drop≤50mV when closedExcessively high voltage drop indicates poor contact connection
Iron Core Pull-inNo obvious noise and slight vibrationLoud noise and obvious vibration are abnormal
Arc ChuteIntact without carbonization marksSevere damage or carbonization requires replacement

VII. Installation and Maintenance Precautions

  1. Pre-installation Preparation:

Confirm that the model matches the load (actuel, tension, contacts auxiliaires)

Check for no external damage and complete accessories (arc chute, mounting bracket)

Select appropriate installation location (bien ventilé, loin des sources de chaleur et des sources de vibrations)

  1. Spécifications d'installation:

Install after power cut, live operation is strictly prohibited

Standard DIN rail mounting (35mm), fix firmly

Main circuit wiring: wire cross-section 16~35mm², double-hole wiring to ensure firm connection

Control circuit wiring: wire cross-section 0.75~1.5mm², avoid laying in the same slot as main circuit

Installation direction: vertical installation (iron core upward), tilt ≤5°

  1. Points clés de l'entretien:

Regular inspection (recommended once a month):

Contact status (presence of ablation and oxidation)

Coil temperature (should not exceed ambient temperature +40°C)

Wiring terminals (presence of loosening and overheating)

Arc chute (presence of damage and carbonization)

Cleaning: Remove dust with dry brush, solvent use is prohibited

Lubrication: Oil application is prohibited on iron core end face, keep clean and dry

Replacement Cycle:

Durée de vie mécanique: approx. 10 millions d'opérations, replacement is recommended after reaching the limit

Durée de vie électrique: approx. 1 millions d'opérations (AC-3), replacement cycle should be shortened for frequent starting

VIII. Résumé

The Chint CJX2-9511 contactor is an industrial-grade contactor with high cost performance and high compatibility. With its 95A rated current and 1NO+1NC auxiliary contact configuration, it is widely used in the control of three-phase motors below 45kW and electrical systems. During selection, comprehensive consideration should be given to factors such as load type, power and coil voltage. Installation and maintenance must strictly follow specifications to ensure safe and reliable operation. Compared with the Kunlun series NXC-9511, the CJX2-9511 has a more competitive price; compared with the Schneider LC1D9511, it has higher cost performance, making it an ideal choice in the field of industrial automation.

Précédent:

Suivant:

Laisser une réponse

Laisser un message