Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

CHNT CJX2-4011 AC Contactor - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

contacteur/

CHNT CJX2-4011 AC Contactor

CJX2-4011 is a 3-pole AC contactor from CHNT’s classic CJX2 series, with a 40A rated current and equipped with 1 NON + 1 NC auxiliary contacts. It is suitable for AC-3 duty (par ex., three-phase motors) and widely used in industrial motor control, power distribution switching, and automation systems. It is a cost-effective choice from a ...

  • Détails du produit

CJX2-4011 is a 3-pole AC contactor from CHNT’s classic CJX2 series, with a 40A rated current and equipped with 1 NON + 1 NC auxiliary contacts.

It is suitable for AC-3 duty (par ex., three-phase motors) and widely used in industrial motor control, power distribution switching, and automation systems. It is a cost-effective choice from a leading domestic brand.

  1. Modèle & Part Number Explanation
Model PartDescription
CJX2Code de série (CJ = AC contactor, X2 = 2nd generation)
40Rated operational current of main poles: 40UN (AC‑3, 380V)
11Contacts auxiliaires: 1 NON (Normalement ouvert) + 1 Caroline du Nord (Normalement fermé)
Common coil voltagesAC24V / AC36V / AC110V / AC220V / AC380V (select as required)
  1. Core Technical Specifications
ArticleSpécificationRemarques
Marque & ModèleCHNT CJX2-4011Compatible with Schneider LC1-D40 series
Poteaux3P. (3 main poles)For three‑phase AC loads
Courant nominal (C'est à dire)40UN (AC‑3, 380V)Suitable for 18.5kW three‑phase motor
Rated operational voltage (Ue)Max. AC690VNormal use: AC380V/400V
Control coil voltageMulti‑range optional (AC24/36/110/220/380V)Must match control circuit voltage
Pouvoir de coupureAC‑3: 40UN; AC‑1: 110UNMeets general industrial load switching
Contacts auxiliaires1 NON + 1 Caroline du NordFor status feedback and interlocking
Montage35mm rail DIN + screw fixingFits standard electrical cabinets
Capacité de câblageMain: 4~10mm² Cu; Coil: 1.5~2.5mm²
Durée de vie mécanique≥ 10 millions d'opérationsReliable for frequent use
Durée de vie électrique≥ 1 millions d'opérations (AC‑3)Silver alloy contacts for durability
Operating temp-5℃ ~ +40℃For standard industrial environments
Protection degreeIP20Prevents finger contact with live parts
  1. Caractéristiques & Avantages
  2. High-reliability contact system

Silver alloy contacts offer good conductivity, anti-welding, and arc resistance

32-sheet silicon steel core for stable, low-noise operation (≤55dB)

Red copper coil + flame-retardant housing for high temperature resistance

  1. Dual mounting flexibility

Standard 35mm DIN rail for quick installation

Also supports screw mounting for panel installation

  1. Energy saving

Low power consumption for long-term operation

Stable coil pull-in, reduced control circuit energy use

  1. Strong compatibility

Directly matches CHNT NR2 series thermal overload relays

Dimensions compatible with Schneider LC1-D40 series for direct replacement

  1. Installation & Guide de câblage

4.1 Exigences d'installation

DIN rail: Clip onto 35mm standard rail and ensure full locking

Screw mounting: Use M4 screws on a flat surface with ≥10mm clearance for heat dissipation

Prefer vertical installation; avoid horizontal mounting

4.2 Spécification de câblage

Type de borneMarkingDescriptionCautions
Main polesL1, L2, L3 (line); T1, T2, T3 (charger)Connect three‑phase power / moteurDisconnect power before wiring; torque 0.8~1.2N·m
CoilA1, A2Connect to control circuit (pushbutton, API)Coil voltage must match; do not reverse polarity
AuxiliaryNON (13‑14), Caroline du Nord (21‑22)Retour / interlock circuitDistinguish NO/NC correctly

4.3 Key Wiring Notes

Do NOT mix main pole and coil terminals

Securely crimp wires to avoid overheating

When used with a thermal relay, connect it after T1/T2/T3

  1. Applications typiques

Commande de moteur triphasé: 7.5kW~18.5kW pumps, les fans, convoyeurs

Industrial power distribution: cabinet switching, capacitor bank control

Automated production lines: PLC-controlled start/stop and interlock

Building systems: CVC, ascenseurs, fire pumps

Machine tools: tours, fraiseuses, drilling machines

  1. Modèles de remplacement & Compatibilité

6.1 CHNT Upgraded Replacements

OriginalRemplacementKey DifferenceApplication
CJX2-4011NXC-4011Kunlun series, upgraded contacts, smaller, lower powerNew panels, system upgrades
CJX2-4011CJX2-40011 NC onlyFault feedback only
CJX2-4011CJX2-40222 NON + 2 Caroline du NordComplex interlocking

6.2 Cross-Brand Equivalents

MarqueEquivalent ModelMatching Specs
SchneiderLC1-D4011M5C40UN, 3P., 1NON+1NC, Bobine AC220V
Siemens3TF4722-0XM040UN, 3P., 2NON+2NC
ABBA40-30-1140UN, 3P., 1NON+1NC
DélicieuxCJX2-4011Directly interchangeable
  1. Purchasing & Conseils d'utilisation
  2. Authenticity

Buy via official channels to avoid counterfeits

Verify model, tension de bobine, and poles

  1. Accessories

Must use with NR2 thermal relay for motor overload protection

Surge suppressor (SR2 series) recommended for frequent switching

  1. Selection Rules

AC-3 for motors; AC-1 for resistive loads

Coil voltage must match control power

Higher protection grade for dusty/humid environments

  1. Entretien

Check terminal tightness every 6–12 months

Clean contacts and replace if worn

Energize briefly before long-term storage

> Note: CJX2-4011 is a general-purpose contactor with high cost-performance, stable supply, and easy replacement. Widely used in machinery, chemical, building materials, light industry.

Complete CHNT AC Contactor Series-Models & Order Codes

Core Overview

CHNT AC contactors cover 5 main series:

CJX2 (classic), NXC (Kunlun upgrade), NC1 (industrial IEC), NC2 (high current), NC8 (high voltage heavy duty).

Models are coded by current + contacts auxiliaires + tension de bobine.

Order codes start with 710010xxxx and cover 6A ~ 1250A.

  1. Série CJX2 (Classic, being phased out)

Application: Small-medium motors, 35mm rail DIN, compatible with Schneider LC1-D.

ModèleKey SpecsTypical Order Code (AC220V)Moteur
CJX2-06106UN, 1NON71001020006102202.2kW
CJX2-09109UN, 1NON71001020009102204kW
CJX2-121012UN, 1NON71001020012102205.5kW
CJX2-181018UN, 1NON71001020018102207.5kW
CJX2-251025UN, 1NON710010200251022011kW
CJX2-321032UN, 1NON710010200321022015kW
CJX2-401140UN, 1NON+1NC71001020040322018.5kW
CJX2-501150UN, 1NON+1NC710010200501122022kW
CJX2-651165UN, 1NON+1NC710010200651122030kW
CJX2-951195UN, 1NON+1NC710010200951122045kW

> Note: 01=1NC, 10=1NO, 11=1NO+1NC. Coil voltages: AC24/36/110/220/380V. Last 3 digits = voltage code.

  1. NXC Series (Kunlun Upgrade, Mainstream)

Application: CJX2 replacement, smaller, lower power, longer life.

ModèleKey SpecsTypical Order Code (AC220V)Application
NXC-066UN, 1NON710010100000498Petit moteur, éclairage
NXC-099UN, 1NON710010100000499Pumps, les fans
NXC-1212UN, 1NON710010100000500Small machines, A/C
NXC-1818UN, 1NON7100101000005017.5kW motor
NXC-2525UN, 1NON71001010000050211kW motor
NXC-3232UN, 1NON71001010000050315kW motor
NXC-4040UN, 1NON+1NC71001010000050418.5kW motor
NXC-5050UN, 1NON+1NC71001010000050522kW motor
NXC-6565UN, 1NON+1NC71001010000050630kW motor
NXC-8080UN, 2NON+2NC71001010000050745kW motor
NXC-100100UN, 2NON+2NC71001010000050855kW motor
NXCQ-4040UN, mechanical emergency710010100002345Fire pump

> Note: Z = DC coil (par ex., NXC-12Z DC24V); M = mechanical latching.

  1. Série NC1 (Industrial IEC Standard)

Application: International standard, high reliability, frequent operation.

ModèleKey SpecsTypical Order Code (AC230V)Coil Type
NC1-09109UN, 1NON7100161000910230CA
NC1-120112UN, 1Caroline du Nord7100161001201230CA
NC1-251125UN, 1NON+1NC7100161002511230CA
NC1-401140UN, 1NON+1NC71001610804011200CA
NC1-651165UN, 1NON+1NC71001610806511200CA
NC1-951195UN, 1NON+1NC71001610809511200CA
NC1-1210Z12UN, 1NON710016121210024DC24V
NC1-2501Z25UN, 1Caroline du Nord7100161212501020DC24V

> Note: NC1-N = reversing contactor. Z = DC coil.

  1. NC2 Series (High Current Industrial)

Application: Heavy motors & main circuits up to 800A.

ModèleKey SpecsTypical Order Code (AC220V)Application
NC2-150150UN, 3P.7100162001501220Main switch, large fan
NC2-225225UN, 3P.7100162002251220Air compressor
NC2-400400UN, 3P/4P7100162004001220Data center
NC2-630630UN, 3P/4P7100162006301220Large equipment
NC2-800800UN, 3P/4P7100162008001220Main incomer

> Note: 3P/4P available. Shunt trip, undervoltage release optional.

  1. NC8 Series (High Voltage Heavy Duty)

Application: Up to 1140V, 2650A for metallurgy, mining, marine.

ModèleKey SpecsTypical Order Code (AC220V)Application
NC8-12M1012UN, 1NON71001680001210200High-voltage auxiliary
NC8-25M1125UN, 1NON+1NC71001680002511200HV motor control
NC8-40M2240UN, 2NON+2NC71001680004022200HV cabinet
NC8-100M22100UN, 2NON+2NC71001680010022200Large HV motor
NC8-500M22500UN, 2NON+2NC71001680050022200Mining, marine

> Note: M = mechanical latching. 4P for 3P+N systems. DC coil available.

  1. General Selection & Order Code Rules

6.1 Model Coding

PositionSignificationExemple (CJX2-4011 AC220V)
PrefixSérieCJX2, NXC, NC1
MiddleCourant nominal (AC‑3, 380V)40 = 40A
Suffixe 1Contacts auxiliaires11 = 1NO+1NF
Suffixe 2Poles/function/4 = 4P; /Z = DC; /M = latching

6.2 Order Code Format

Standard: 710010xxxxxxx

Exemple:

CJX2-4011 AC220V → 710010200403220

NXC-12 DC24V → 710010100000500Z

6.3 Points clés de sélection

  1. Charger: AC-3 for motors; AC-1 for resistive loads
  2. Coil voltage must match control power
  3. Contacts auxiliaires: 10, 01, 11, 22
  4. Poteaux: 3P for three-phase; 4P for 3P+N
  5. Series Comparison & Recommendation
SérieCurrentKey StrengthApplication
CJX26A~95AMature, low cost, compatibleRetrofit, general use
NXC6A~100APetit, low power, long lifeNew projects, automation
NC19A~95AIEC standard, high reliabilityExporter, frequent duty
NC2150A~800AHigh current, heavy dutyIndustrie, data center
NC812A~2650AHV, extreme environmentMetallurgy, mining, marine

Précédent:

Suivant:

Laisser une réponse

Laisser un message