Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

Delta VFD450C43S-00 Onduleur - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

onduleur solaire/électrique/

Delta VFD450C43S-00 Onduleur

This is a Delta C2000+ Series 45kW/60HP 400V-class high-performance vector inverter. It adopts FOC (Field-Oriented Control) technology and supports three-motor drive: induction motor, permanent magnet synchronous motor (PMSM), and synchronous reluctance motor (SynRM). It features 150% overload capacity for 60 secondes, built-in PLC (10k steps) and DC reactor, suitable for high-dynamic loads such as extruders, ...

  • Détails du produit

This is a Delta C2000+ Series 45kW/60HP 400V-class high-performance vector inverter. It adopts FOC (Field-Oriented Control) technology and supports three-motor drive: induction motor, permanent magnet synchronous motor (PMSM), and synchronous reluctance motor (SynRM). It features 150% overload capacity for 60 secondes, built-in PLC (10k steps) and DC reactor, suitable for high-dynamic loads such as extruders, cranes, machine tool spindles, and is a mainstream model in industrial automation.

  1. Full Model Code Breakdown (VFD450C43S-00)
SectionMarkingDescriptionTechnical Note
1VFDProduct Series PrefixStandard identifier for Delta AC drives
2450Rated Power CodeCorresponds to 45kW/60HP (Heavy Duty rating)
3CSeries CodeC2000+ Series (upgraded from C2000), high-performance vector control
44Voltage Class400V class (3-phase 380–480V, global 400V grid compatible)
53Phase3-phase input / output
6SStructure/SpecModèle standard (no conduit box, UL open type installation)
70Configuration CodeVersion de base, no built-in EMC filter, Protection IP20
  1. Paramètres techniques clés
ArticleValeurRemarques
Série de produitsVFD-C2000+ (C2000 Plus)Delta flagship vector inverter, upgraded from C2000
Puissance nominale45kW / 60HPHeavy-duty design for high-dynamic loads
Rated Output Current91UN (50/60Hz)Heavy Duty (HD) rating; Standard Heavy Duty (SHD) up to 113A
Tension d'entrée3-phase 380–480V, 50/60HzWide voltage range, adapts to grid fluctuations
Tension de sortie3-phase 0–input voltagePWM control, linear variation with frequency
Méthode de contrôleFOC Vector Control / V/F ControlSensorless vector / Closed-loop vector; speed ratio 1:2000
Motor CompatibilityInduction / PMSM / SynRMTri-motor drive for versatile applications
Capacité de surcharge150% rated current for 60s; 180% for 3sIdeal for shock loads and heavy industrial environments
Built-in ComponentsDC reactor, API (10k steps), brake unit interfaceStandard DC reactor, PF ≥ 0.95
CommunicationBuilt-in Modbus RTU, supports extension modulesPROFINET, EtherCAT, EtherNet/IP available
Digital Inputs8 points (expandable to 16)Programmable for versatile control
Analog Inputs2 points (voltage/current selectable)0–10V / 4–20mA for remote speed reference
Relay Outputs3 points (general/alarm/run)Status indication and fault relay
Protection DegreeIP20 (standard)IP54 kit optional for harsh environments
Température ambiante-10℃ to +55℃Wide temp range, PCB coating (3C3 level)
Dimensions (mm)H×L×P: 480×260×375 (Frame D)Standard industrial size for cabinet mounting
PoidsEnviron. 29kilosStandard weight, installation facile
  1. Applications typiques
  2. Heavy-Duty Industrial Applications

Metalworking: Machine tool spindles, fraiseuses, grinders requiring high-precision speed/torque control

Plastic & Rubber Machinery: Extruders, injection molding machines with stable pressure control and high dynamic response

Hoisting & Conveying: Cranes, elevators, port machinery needing 150% overload for start-up shock

Mining Machinery: Crushers, conveyors for harsh environments and frequent starts/stops

  1. General Industrial Loads

Ventilateurs & Pumps: Large HVAC, wastewater treatment; energy-saving algorithm, up to 30%+ energy reduction

Machines textiles: Carding machines, spinning frames with high low-speed torque and precise synchronization

Machines d'emballage: High-speed lines requiring smooth acceleration/deceleration for improved efficiency

  1. Special Technical Advantages

Multi-motor Synchronization: Built-in PLC for complex logic and multi-axis sync

Gestion de l'énergie: Power monitoring for consumption analysis and optimization

Remote Maintenance: Modbus/TCP for SCADA integration and remote diagnosis

Harsh Environments: -10℃ to +55℃ operation, PCB coating for dust and humidity resistance

  1. Replacement Models

4.1 Delta Upgrades / Replacements

Modèle de remplacementDifférence principaleApplication
VFD450C43A-00With conduit box, UL enclosed typeMarché nord-américain, câblage standardisé
VFD450C43S-21Filtre CEM intégré + conduit boxSystems with high EMC requirements
VFD450C43S-01With STO (Coupure sûre du couple)Cranes, elevators and safety-critical applications
VFD450C43S-4GPROFINET communicationSmart manufacturing with industrial Ethernet

4.2 Cross-Brand Equivalents

MarqueModèleParamètres de correspondance clésRemarques
ABBACS880-04-092A-545kW, 92UN, 400V, DTC controlHigh-performance vector drive for complex loads
SchneiderATV930U45N445kW, 91UN, 400V, contrôle vectorielBuilt-in PLC, multi-protocol support
SiemensG120XA 6SL3220-3YE48-0UA045kW, 91UN, 400V, fan/pump optimizedHVAC-focused, high energy efficiency
FujiFRN0090G2S-4G45kW, 90UN, 400V, vecteur sans capteurBuilt-in brake unit for frequent starts/stops
  1. Sélection & Application Notes
  2. Correspondance de charge

Heavy loads (extrudeuses, cranes) must use HD rating (150%/60s) for stable long-term operation

General loads (les fans, pompes) may use SHD rating (110%/60s) for cost efficiency

Shock loads (presses, crushers) recommend 20% power oversizing to avoid frequent tripping

  1. Braking System

Standard unit has no built-in brake unit; external brake unit + resistor required for fast stopping

For braking torque >20%, recommend Delta DBU-4055 brake unit + DR-1200 resistor

  1. Communication

Base version: Modbus RTU only

PROFINET / EtherCAT / EtherNet/IP require optional DVCCNET-xxx card

  1. Installation & Cooling

Must be mounted vertically with ≥100mm clearance above and below

Derate 1% per °C above 40°C or add forced cooling

IP54 kit recommended for dusty environments to extend service life

  1. Entretien

Regularly inspect fan and main capacitor; use built-in lifetime diagnosis

Clean heat sink every 6 months to prevent overheating

Keep firmware updated via Delta ISPSoft software

Delta VFD450C43S-00 is an outstanding 45kW vector inverter with tri-motor drive, 150% heavy-duty capacity, built-in PLC and DC reactor, making it ideal for high-demand industrial automation. Select based on load type, braking and communication needs, or choose upgraded variants for enhanced performance. Its wide-temperature design and high reliability ensure stable operation in harsh environments, supporting productivity and energy savings.

Delta VFD450C43S-00 – Key Selection Notes (Field Version)

  1. Power & Correspondance de charge

This drive is Heavy Duty (HD): 45kW/91A, 150%/60s overload for extruders, cranes, crushers, machine tools.

Fans/pumps can be used as SHD 60kW, but oversizing is not recommended.

For shock loads (presses, crushers), oversize by one power level or verify overload margin.

  1. Voltage & Grid

3-phase 380–480V input, 50/60Hz universal.

For unstable or high-harmonic grids: DC reactor is built-in, but an input AC reactor is still recommended.

  1. Motor Compatibility

Supports induction / PMSM / SynRM in three drive modes.

Auto-tuning is mandatory for PMSM; otherwise torque and speed will be unstable.

  1. Freinage & Stopping (Critical)

VFD450C43S-00 has NO built-in brake unit!

For fast stopping or overhauling loads (cranes, elevators, downhill conveyors):

External brake unit + resistor is required.

Recommandé: Delta DBU-4055 brake unit.

  1. Installation, Cooling & Protection

Must be mounted vertically with ≥100mm ventilation space top and bottom.

Derate when ambient > 40°C (≈1% per °C).

Unit is IP20 open type; use enclosure or IP54 kit in dust, moisture or oil.

  1. EMC

-00 version has NO built-in EMC filter.

For sensitive devices (sensors, API): add external EMC filter + shielded cable + proper grounding.

  1. Sécurité

This model does NOT include STO (Coupure sûre du couple).

For safety-related applications (palans, machines), use STO-equipped model (-01 suffixe) or external safety relay.

  1. Communication & Expansion

Standard only Modbus RTU.

PROFINET / EtherCAT / EtherNet/IP require optional communication card.

  1. Spare Parts & Entretien

Recommended spares: cooling fan, condensateurs, résistance de freinage.

Use keypad parameter copy for fast commissioning of multiple drives.

 

Précédent:

Suivant:

Laisser une réponse

Laisser un message