Eaton PKZM0-16 Motor-Protective Circuit Breaker - Contacteur,disjoncteur,capteur,Encodeur,API,Convertisseur

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

 Eaton PKZM0-16 Motor-Protective Circuit Breaker - Contacteur,disjoncteur,capteur,Encodeur,API,Convertisseur

disjoncteur/

Eaton PKZM0-16 Motor-Protective Circuit Breaker

Numéro de commande: 046938 Part of Moeller PKZM0 series; 3-pole rotary-knob motor circuit breaker integrating overload & protection contre les courts-circuits, Classe 10 caractéristique du voyage, with built-in phase-failure protection. ✅ Core Technical Parameters Poles: 3P Adjustable current setting range: 10~16 A Rated operational voltage Ue: Max.. CA 690 V Matched motor power (AC-3, 50 Hz): 230 V: 4 ...

  • Détails du produit

Numéro de commande: 046938

Part of Moeller PKZM0 series; 3-pole rotary-knob disjoncteur moteur integrating overload & protection contre les courts-circuits, Classe 10 caractéristique du voyage, with built-in phase-failure protection.

✅ Core Technical Parameters

Poteaux: 3P.

Adjustable current setting range: 10~16 A

Tension assignée d'emploi Ue: Max.. CA 690 V

Puissance moteur adaptée (AC-3, 50 Hz):

230 V: 4 kW

400 V: 7.5 kW

440 V: 9 kW

Instantaneous short-circuit trip current: Fixé à 248 UN

Classe de voyage: Classe 10

Terminaison: Bornes à vis

Classe de protection: IP20 (front touch-safe)

Dimensions hors tout: W45 mm × H93 mm × D76 mm

Endurance électrique: 100,000 opérations

Normes: CEI/EN 60947-4-1, VDE, UL508, CE, CSA certified

✅ Key Features

  1. Sensitive phase-failure protection; trips rapidly on single phasing to prevent motor burnout.
  2. Rotary knob with padlock provision for lockout/tagout (CŒUR) safety isolation.
  3. Built-in TEST pushbutton for manual mechanical trip testing.
  4. Wide range of add-on accessories: contacts auxiliaires, fault trip contacts, déclencheur à minimum de tension, voyage de dérivation, side busbars.
  5. Montage sur rail DIN; conception modulaire, directly combinable with DILM contactors to form MSC motor starter units.

✅ Variants with Suffixes (Same Current Rating)

PKZM0-16: Standard screw terminals (Numéro de commande. 046938)

PKZM0-16-EA: EA export version

PKZM0-16-SPI32: Screw terminals on line side, push-in spring terminals on load side

PKZM0-16-GVP2: Bulk packaging version

✅ Sélection & Equivalent Cross Reference

Domestic equivalents: Delixi CDP6-16, Chint NS2-25 (10–16 A)

Next higher rating in series: PKZM0-20 (16~20 A)

Note: PKZM0 is an integrated breaker; it cannot be used solely as an overload relay. Use ZB series if only thermal overload protection is required.

✅ Troubleshooting Guide

  1. Trips immediately with no load: Check if current setting is too low, perte de phase, or mechanical trip mechanism jamming.
  2. Instant trip on motor startup: Short-circuit protection triggered; inspect motor winding short-circuit or cable fault.
  3. Slow trip under sustained overload: Normal Class 10 inverse-time behaviour; if tripping frequently under heavy load, increase the current setting or upgrade to a higher-rated model.

Full Accessory List for PKZM0 Series (Applicable to PKZM0-16)

Installation rule: NHI-E = front-mounted; NHI = side-mounted; AGM = fault trip contact; U-PKZ0 = undervoltage release; A-PKZ0 = shunt trip. Suffix -PI = push-in spring terminals; no suffix = screw terminals.

  1. Contacts auxiliaires standards (Main contact status feedback: closed/open signal)
  2. NHI-E-10-PKZ0|1NO, monté à l'avant
  3. NHI-E-01-PKZ0|1NC, monté à l'avant
  4. NHI-E-11-PKZ0|1NO+1NC (le plus courant), monté à l'avant
  5. NHI11-PKZ0|1NO+1NC, monté sur le côté
  6. NHI21-PKZ0|2NO+1NC, monté sur le côté
  7. NHI12-PKZ0|1NO+2NC, monté sur le côté

PI version available: NHI-E-11-PKZ0-PI (bornes à ressort)

Notation: AC-15 230 V 0.5 UN, DC-13 24 V; used for PLC feedback and status indication lamps.

  1. Fault Trip Contacts (Only actuated on protective trip – critical distinction!) AGM Series

Only changes state when tripped by overload / court-circuit / perte de phase; remains inactive during manual ON/OFF operations, used exclusively for fault alarm signals.

  1. AGM2-01-PKZ0|2NC (standard for engineering projects)

PKZM0 Full Model List

1) Standard Screw Terminal Models (Base Version, No Suffix)

ModèleAdjustment Range IrMoteur assorti (400 V)Eaton Numéro de commande.
PKZM0-0,160.10~0.16 A0.04 kW72730
PKZM0-0,250.16~0.25 A0.06 kW72731
PKZM0-0,40.25~0.40 A0.09 kW72732
PKZM0-0,630.40~0.63 A0.18 kW72733
PKZM0-10.63~1.00 A0.25 kW72734
PKZM0-1,61.00~1.60 A0.37 kW72735
PKZM0-2,51.60~2.50 A0.55 kW72736
PKZM0-42.50~4.00 A1.1 kW72737
PKZM0-6,34.00~6.30 A2.2 kW72738
PKZM0-106.30~10.0 A4.0 kW46937
PKZM0-128.00~12.0 A5.5 kW278486
PKZM0-1610.0~16.0 A7.5 kW46938
PKZM0-2016.0~20.0 A9.0 kW46988
PKZM0-2520.0~25.0 A11 kW46989
PKZM0-3225.0~32.0 A15 kW278489

Définition du suffixe (Même note actuelle, only terminal/function differs)

  1. -PI: Bornes à ressort enfichables (câblage sans outil); exemple: PKZM0-16-PI
  2. -C: Older spring clamp version (same function as PI)
  3. -EA: Export overseas standard model (identical construction to domestic standard version)
  4. -T: Transformer protection variant (NO phase-failure protection, only thermal + short-circuit trip); exemple: PKZM0-0,63-T
  5. /ET: Thumb-lock rotary handle, field padlockable
  6. -SPI32: Mixed terminals: line-side screw, load-side push-in

2) PKZM01 Compact Series (Toggle handle, NO phase-failure protection; only overload + short-circuit trip)

Note: PKZM01 has no phase-loss protection; only for small motors without single-phasing risk.

ModèleAdjustment Current Range
PKZM01-0.40.25~0.4 A
PKZM01-0.630.4~0.63 A
PKZM01-10.63~1 A
PKZM01-1.61~1.6 A
PKZM01-2.51.6~2.5 A
PKZM01-42.5~4 A
PKZM01-6.34~6.3 A
PKZM01-106.3~10 A
PKZM01-128~12 A
PKZM01-1610~16 A
PKZM01-2016~20 A
PKZM01-2520~25 A

3) Higher-Current PKZM4 Series (16~63 A, fully interchangeable accessories with PKZM0)

PKZM4-16 / PKZM4-20 / PKZM4-25 / PKZM4-32 / PKZM4-40 / PKZM4-50 / PKZM4-63

4) Règle de dénomination du modèle (Quick Selection)

PKZM0 16 PI

  1. PKZM0 = Motor-protective circuit breaker (with phase-failure protection, rotary handle)
  2. Numeric value = Maximum adjustable current (16 = 10~16 A)
  3. Suffix = Terminal type / special function

5) Standard Accessory List (Fits all PKZM0 variants)

1) Contacts auxiliaires (Position feedback)

NHI-E-11-PKZ0 (Front-mounted: 1NON+1NC)

NHI11-PKZ0 (Monté sur le côté: 1NON+1NC)

2) Fault Trip Contacts (Only triggered by overload/phase loss/short-circuit)

AGM2-01-PKZ0 (2Caroline du Nord, standard for site engineering)

3) Voltage Releases (Only one can be fitted at a time, not both together)

U-PKZ0 Undervoltage release (24VCC / 110V / 230V / 400V)

A-PKZ0 Shunt trip release (24VCC / 110V / 230V / 400V)

4) Mechanical Accessories

PKZ0-XRH: Extended rotary handle for cabinet door mounting (padlockable)

CL-PKZ0: Phase barrier

B-PKZ0: Parallel busbar for multiple units

6) Lignes directrices de sélection

  1. Require phase-failure protection → Choose PKZM0; No phase-loss risk & cost-sensitive → Choose PKZM01.
  2. Remote tripping → Select A-PKZ0 shunt trip; Anti-restart on power failure → Select U-PKZ0 undervoltage release (cannot mount both).
  3. Frequent on-site wiring → Prefer -PI push-in terminal version; General installation → Standard screw terminal model.

Précédent:

Laisser une réponse

Laisser un message