Model Code Breakdown Code Segment Meaning Detailed Description FX5 Series Identifier Mitsubishi MELSEC iQ-F series, 5th-generation high-performance compact PLC platform, compatible with FX5U/FX5UC/FX5UJ CPUs, supporting high-speed system bus communication 4 Number of Channels 4 independent analog output channels, capable of simultaneously outputting different analog signals DA Function Type Digital-to-Analog conversion, converting PLC digital signals into ...

  • Détails du produit
  1. Model Code Breakdown
Code SegmentSignificationDescription détaillée
FX5Series IdentifierMitsubishi MELSEC iQ-F series, 5th-generation high-performance compact PLC platform, compatible with FX5U/FX5UC/FX5UJ CPUs, supporting high-speed system bus communication
4Number of Channels4 independent analog output channels, capable of simultaneously outputting different analog signals
DAFunction TypeDigital-to-Analog conversion, converting PLC digital signals into analog voltage/current signals recognizable by external actuators
No SuffixInstallation TypeBasic type with spring clamp terminal block design, directly mounted on the expansion bus to the right of the CPU (non-ADP adapter type)
  1. Paramètres techniques de base

2.1 Spécifications de base

ParamètreValeurRemarques
Number of Output Channels4 channels (independent)Each channel can be independently configured for voltage or current output
Occupied I/O Points8 points4 points for input and 4 points for output
Conversion Speed80μs per channelHigh-speed conversion, suitable for dynamic control scenarios
Power RequirementDC5V, approx. 120mAPowered by FX5 series CPU or dedicated power module
Insulation MethodOptocoupler insulation between output terminals and PLC, non-insulated between channelsAnti-interference design to protect PLC system
Classe de protectionIP20For cabinet installation, étanche à la poussière
Dimensions (L×H×P)40mm×90mm×102.2mmCompact design, économiser de l'espace dans l'armoire
PoidsEnviron. 0.2kilosLightweight, easy to install
Température de fonctionnement0~55℃Industrial standard environment

2.2 Analog Output Performance Parameters

Output TypeRangeCorresponding Digital ValueResolutionPrécision (25±5℃)Deviation Range
Voltage Output0~10V0~32000312.5μV±0.1%FS±20mV
0~5V0~32000156.25μV±0.1%FS±10mV
1~5V6400~32000125μV±0.1%FS±8mV
-10~+10V-32000~+32000312.5μV±0.1%FS±20mV
Current Output0~20mA0~32000625nA±0.1%FS±20μA
4~20mA6400~32000500nA±0.1%FS±16μA

Accuracy Note: Accuracy is ±0.2%FS within the temperature range of -20~55℃

  1. Scénarios d'application & Guidance

3.1 Typical Application Fields

IndustrieScénario d'applicationSpecific Cases
Process ControlFlow/Pressure/Temperature RegulationValve positioner control, PID loop regulation, temperature controllers
Contrôle de mouvementSpeed/Torque ControlInverter frequency setting, servo drive speed control, DC motor speed regulation
Automatisation industrielleActuator ControlProportional valves, hydraulic systems, pneumatic control valves, analog display instruments
Test & MeasurementSignal SimulationSensor simulation, test equipment calibration, analog signal generators
Équipement médicalPrecision ControlMedical analyzers, laboratory equipment, pharmaceutical machinery

3.2 Points clés de sélection

  1. Channel Requirement: Confirm the required number of analog output channels; 4 channels meet most small and medium-sized control systems
  2. Output Type: Select voltage (0~10V/-10~+10V) or current (4~20mA) output based on actuator type
  3. Accuracy Requirement: Choose FX5-4DA for high-precision control (par ex., ±0.1%); consider economical alternatives for general control
  4. Vitesse de réponse: Verify if 80μs conversion speed meets requirements for fast dynamic response systems (par ex., servo control)
  5. Méthode d'installation: FX5-4DA mounts directly to the right of the CPU; FX5-4DA-ADP mounts on DIN rail via extension cable
  6. Compatibilité: Only compatible with FX5 series CPUs; select corresponding models for older series like FX3U
  7. Installation & Configuration Guide

4.1 Étapes d'installation

  1. Power-off Operation: Cut off all PLC power before installation to prevent electric shock
  2. Installation mécanique:

Mount directly on the expansion bus to the right of FX5U/FX5UC CPU, align with the guide rail and push to lock

For multiple module expansion, install in sequence with ≥5mm gap between modules for heat dissipation

  1. Spécifications de câblage:

Use shielded twisted pair for analog output wiring, with shield grounded at one end (PLC side)

Separate power and signal wiring with a distance ≥100mm to avoid interference

Terminal wiring: +V for positive, -V for negative, COM as common terminal

  1. Exigences de mise à la terre:

Adopt Class D grounding (ground resistance ≤100Ω) with grounding wire ≥2mm²

Prohibit shared grounding with high-power equipment to prevent ground potential interference

4.2 GX Works3 Parameter Configuration Steps

  1. Module Addition:

Right-clickModule Informationin project tree →Add New Module→ SelectAnalog Output” → “FX5-4DA→ Set unit number

  1. Channel Parameter Setting:

Double-click the module to enter parameter interface, set for each channel:

Output type (Voltage/Current)

Range (par ex., 0~10V, 4~20mA)

Output hold function (maintain last output value after power-off)

Calibration parameters (Auto/Manual calibration)

  1. Programming:

Read/write module data via FROM/TO instructions or use GX Works3 dedicated instructions

Digital-to-analog conversion formula: Analog output value = Digital value × Range / 32000 (unipolar) ou 64000 (bipolar)

4.3 Calibration Process

  1. Auto Calibration: ExecuteAuto Calibrationfunction in GX Works3; the module automatically completes zero and gain calibration
  2. Manual Calibration:

Short-circuit output terminals, adjust zero potentiometer to achieve 0 output

Input full-scale digital value, adjust gain potentiometer to achieve full-scale output

  1. Calibration Cycle: Recommended every 6 mois; shorten to 3 months in harsh environment
  2. Modèles alternatifs & Recommandations de sélection

5.1 Mitsubishi Same-series Alternative/Upgrade Models

ModèleMain DifferencesScénario d'application
FX5-4DA-ADPADP adapter type, mounted on DIN rail via FX5-ADP-BUS cable, up to 10m from CPULimited cabinet space, remote installation required
FX5-2DA2-channel version, occupant 4 I/O points with more compact size (25mm largeur)Fewer channel requirements, space-saving
FX5-8DA8-channel version to meet multi-channel control needsLarge-scale control systems requiring more analog outputs
FX5U-4DAAnalog output built into FX5U CPU, no additional expansion module neededCost-saving, simplified system structure
FX5-4DA-PHigh-precision version with accuracy improved to 卤0.05%FSUltra-high precision control (par ex., process control, medical equipment)

5.2 Cross-series/Cross-brand Alternative Models

MarqueAlternative ModelMatching DegreeCaractéristiques
Mitsubishi FX3U SeriesFX3U-4DA★★★★☆Compatible with FX5U via FX5-CNV-IF adapter, accuracy ±0.2%FS, conversion speed 10ms
SiemensSM 1232★★★★S7-1200 series, 4 channels, accuracy ±0.1%FS
SchneiderTM2DAI4★★★★Modicon M221 series, 4 channels, hot-swappable
Domestic AlternativeTanshuo FX5-4DA-ADP★★★★Fully compatible with Mitsubishi FX5 series, more cost-effective
OmronCJ1W-DA041★★★☆CJ series, 4 channels, conversion speed 50μs
  1. Entretien & Troubleshooting

6.1 Regular Maintenance Schedule

Cycle d'entretienArticleStandardMaintenance Measures
MonthlyInspection visuelleNo damage, looseness, or overheating marksClean dust on module surface, check terminal connections
QuarterlySignal TestOutput error ≤±0.1%FSMeasure each channel output with multimeter and compare with set value
Every 6 MonthsCalibration CheckZero offset ≤±10mV/±10μAPerform auto calibration, manual adjustment if necessary
AnnualInsulation TestInsulation resistance ≥10MΩ (500V mégohmmètre)Test module insulation performance under power-off condition
System UpgradeMise à jour du micrologicielLatest versionUpdate module firmware via GX Works3 to fix known issues

6.2 Dépannage des pannes courantes & Solutions

Phénomène de défautCauses possiblesPriorityÉtapes de dépannage
No Output Signal1. Unconfigured moduleHigh1. Check GX Works3 parameter configuration
2. Disabled output channel2. Enable channel output function
3. Incorrect wiring3. Verify wiring (+V/-V/COM)
4. Power failure4. Measure module DC5V power supply
Output Accuracy Deviation1. Uncalibrated or expired calibrationMedium1. Perform auto calibration
2. Ambient temperature out of range2. Improve heat dissipation and control ambient temperature
3. Mismatched load resistance3. Voltage output load ≥400kΩ, current output load 250~500Ω
4. Module aging4. Replace module
Output Fluctuation1. Excessive power supply rippleMedium1. Install power filter
2. Signal interference2. Check shield grounding and keep away from power lines
3. Poor grounding3. Optimize grounding system with independent grounding
4. Unstable load4. Check actuator load
Module Error Report1. Incompatible firmware versionHigh1. Update module firmware to latest version
2. Poor expansion bus connection2. Reconnect module and check expansion bus
3. Damaged module3. Replace module for testing
  1. Safe Operation Specifications
  2. Power-off Operation: All installation, wiring, and maintenance work must be performed with PLC completely powered off
  3. ESD Protection: Discharge static electricity from human body before touching the module to avoid damaging electronic components
  4. Spécifications de câblage:

Prohibit connecting AC power to DC module terminals (may cause module burnout)

Prohibit external wiring to empty terminals to prevent short circuit

  1. Correspondance de charge:

Voltage output: External load resistance ≥400kΩ

Current output: External load resistance 250~500Ω to avoid overload

  1. Exigences de dissipation thermique:

Leave ≥5mm heat dissipation space around the module

Cabinet temperature ≤55℃; install cooling fan if necessary

  1. Résumé & Recommandations de sélection

FX5-4DA is a high-performance 4-channel analog output module in Mitsubishi FX5 series, featuring 80μs high-speed conversion, ±0.1% high accuracy, and independent channel configuration. It is suitable for industrial automation scenarios requiring precise analog signal control. Its core advantages lie in seamless integration with FX5 series CPUs and high-speed system bus communication, fully leveraging the performance of the 5th-generation PLC.

Recommandations de sélection:

  1. Prioritize FX5-4DA for new projects, as its performance comprehensively outperforms older series like FX3U
  2. Choose FX5-4DA-ADP adapter type for limited space or remote installation needs
  3. Recommend FX5-4DA-P high-precision version for high-precision control scenarios (par ex., process control, medical equipment)
  4. Consider FX5-2DA to save cost and space when channel requirements are low (≤2)
  5. When used with FX5U CPU, utilize built-in analog functions of the CPU plus FX5-4DA expansion for more flexible system configuration

Comprehensive Guide to Alternative Models for Mitsubishi FX5-4DA Analog Output Module

  1. Mitsubishi Same-series Alternative/Upgrade Models (Highly Recommended)

The following models are native products of Mitsubishi FX5 series, seamlessly compatible with FX5U/FX5UC/FX5UJ CPUs, and serve as the optimal alternatives to FX5-4DA.

ModèleDifférences fondamentalesConversion SpeedPrécisionOccupied I/O PointsMéthode d'installation
FX5-4DA-ADPAdapter type connected via FX5-ADP-BUS cable2.5ms per channel±0.1%FS (25℃)0 pointsDIN rail installation, up to 10m from CPU
FX5-2DA2-channel version with more compact size80μs per channel±0.1%FS (25℃)4 pointsDirect installation to the right of CPU
FX5-8DA8-channel version for multi-channel control80μs per channel±0.1%FS (25℃)16 pointsDirect installation to the right of CPU
FX5-4DA-PHigh-precision version with enhanced performance80μs per channel±0.05%FS (25℃)8 pointsDirect installation to the right of CPU
FX5U-4DABuilt into FX5U CPU80μs per channel±0.1%FS (25℃)AucunNo additional installation required

Key Difference Comparison Table

FonctionnalitéFX5-4DAFX5-4DA-ADPFX5-2DAFX5-8DAFX5-4DA-P
Number of Channels44284
Installation PositionRight of CPURemote rail installationRight of CPURight of CPURight of CPU
Bus ConnectionDirect expansion busADP bus (cable connection)Direct expansion busDirect expansion busDirect expansion bus
Conversion Speed80s per channel2.5ms per channel80s per channel80s per channel80s per channel
Occupied I/O8 points0 points4 points16 points8 points
Accuracy Grade0.1%FS0.1%FS0.1%FS0.1%FS0.05%FS
Maximum Expansion Quantity4 unités4 unités4 unités4 unités4 unités
  1. Mitsubishi Cross-series Alternative Models (Downward Compatible/Upgrade)

Suitable for upgrading from older series or compatible with existing systems.

ModèleSérieCompatibilitéParamètres de baseReplacement Suggestion
FX3U-4DAFX3U SeriesRequires FX5-CNV-IF adapter to connect to FX5U10ms per channel, ±0.2%FSTransitional solution for upgrading old systems to FX5U; not recommended for new projects
FX3U-2DAFX3U SeriesSame as above10ms per channel, ±0.2%FSUpgrade for old systems with fewer channel requirements
FX5-4A-ADPFX5 SeriesDirectly compatible with FX5U2.5ms per channel, ±0.1%FSSelect when 2-channel input + 2-channel output are needed simultaneously
FX5-8AD-4DAFX5 SeriesDirectly compatible with FX5U80μs per channel, ±0.1%FSLarge-scale systems with mixed input/output requirements
  1. Cross-brand Alternative Models (Performance Equivalent)

The following models from different brands have performance equivalent to FX5-4DA, suitable for brand switching or multi-brand system integration.

MarqueAlternative ModelParamètres de baseCaractéristiques
SiemensSM 12324 channels, 12-bit resolution, ±0.1%FSS7-1200 series, hot-swappable, seamless integration with Siemens PLCs
SchneiderTM2DAI44 channels, 12-bit resolution, ±0.1%FSModicon M221 series, Modbus support, moderate price
OmronCJ1W-DA0414 channels, 12-bit resolution, 50μs per channelCJ series, high-speed conversion, suitable for fast response systems
Rockwell1762-OW44 channels, 12-bit resolution, ±0.1%FSMicroLogix 1200 série, supports RSLogix programming software
Domestic AlternativeTanshuo FX5-4DA-ADP4 channels, 80μs per channel, ±0.1%FSFully compatible with Mitsubishi FX5 series, more cost-effective, partially interchangeable parts
DeltaDVP04DA-H34 channels, 12-bit resolution, ±0.2%FSDVP series, supports Delta WPLSoft software, high cost-performance ratio
  1. Alternative Selection Decision Guide

4.1 Selection by Installation Requirements

Installation ScenarioModèle recommandéReason
Direct installation to the right of CPUFX5-4DA/FX5-2DA/FX5-8DANo additional cables needed, fastest communication speed (system bus)
Remote installation (>1m from CPU)FX5-4DA-ADPConnected via ADP bus cable, up to 10m maximum distance
Limited cabinet spaceFX5-4DA-ADP/FX5-2DAAdapter type for flexible installation; 2-channel model only 25mm wide
Multi-module expansion (>4 unités)FX5-4DA-ADPSupports more expansions without occupying CPU-side installation space

4.2 Selection by Performance Requirements

Performance IndicatorModèle recommandéReason
High-speed dynamic response (<1MS)FX5-4DA/FX5-2DA/FX5-8DA/FX5-4DA-P80s per channel, suitable for servo control and fast process regulation
High-precision control (<卤0.1%)FX5-4DA-P0.05%FS accuracy, meeting requirements of laboratory and medical equipment
Multi-channel synchronous outputFX5-8DA8-channel simultaneous output, suitable for large-scale production line control
Cost-effective solutionFX5-4DA-ADP/FX3U-4DALower price for adapter type; high cost-performance ratio for older series models

4.3 Selection by Functional Requirements

Functional RequirementModèle recommandéReason
Mixed input/outputFX5-4A-ADP/FX5-8AD-4DAProvides both input and output channels simultaneously, simplifying system configuration
No I/O point occupationFX5-4DA-ADPAdapter type does not occupy PLC I/O points, saving resources
Built-in solutionFX5U-4DAIntegrated into CPU, reducing external modules and improving reliability
Food/Medical IndustryFX5-4DA-PHigh precision + food-grade certification, meeting industry-specific requirements
  1. Notes on Replacement
  2. Compatibility Confirmation:

Mitsubishi same-series models are directly compatible with FX5U/FX5UC/FX5UJ CPUs

Verify communication protocols and physical connections for cross-series/cross-brand models

BFM address allocation differs between FX5-4DA-ADP and FX5-4DA, requiring corresponding program adjustments

  1. Parameter Configuration Adjustment:

Conversion speed difference: FX5-4DA-ADP (2.5MS) is slower than FX5-4DA (80µs), requiring control algorithm adjustments

Accuracy difference: Some alternative models may have slightly different accuracy, requiring recalibration

Output load matching: Ensure the output load range of the alternative model matches the actuator

  1. Installation & Câblage:

Adapter type requires dedicated FX5-ADP-BUS cable

Analog output wiring must use shielded twisted pair with single-end grounding of the shield

Terminal definitions vary across different brand modules; refer to manuals for verification

Mitsubishi FX5-4DA has a wide range of alternative models. Priority is recommended for Mitsubishi same-series products such as FX5-4DA-ADP (remote installation), FX5-2DA (fewer channels), FX5-8DA (more channels), and FX5-4DA-P (high precision), which are seamlessly compatible with FX5U CPUs and fully leverage system performance. Among cross-brand alternatives, Siemens SM 1232, Schneider TM2DAI4, and domestic Tanshuo FX5-4DA-ADP are excellent choices, which can be flexibly selected based on specific application scenarios and budgets.

Suggestions de sélection: Prioritize Mitsubishi FX5 series native products for new projects; select FX3U series as a transitional solution for old system upgrades; fully evaluate compatibility and cost-performance ratio when switching brands.

Précédent:

Laisser une réponse

Laisser un message