Onduleur Schneider ATV71 HU75N4Z

This is a Schneider Altivar 71 series inverter dedicated for fans and pumps. Below is technical data organized directly for selection/purchasing: Model Breakdown ATV71: Schneider high-performance general-purpose vector inverter series HU: Dedicated for HVAC fans & pompes (algorithme d'économie d'énergie, suitable for pump/fan loads) 75: Applicable motor power 7.5 kW N: Voltage class 3-phase 380~480 V, ...

  • Détails du produit

This is a Schneider Altivar 71 série onduleur dedicated for fans and pumps. Below is technical data organized directly for selection/purchasing:

  1. Répartition du modèle

ATV71: Schneider high-performance general-purpose vector inverter series

HU: Dedicated for HVAC fans & pompes (algorithme d'économie d'énergie, suitable for pump/fan loads)

75: Applicable motor power 7.5 kW

N: Voltage class 3-phase 380~480 V, 50/60 Hz

4: Mode de contrôle: Contrôle vectoriel

Z: Version standard (filtre CEM intégré, braking unit, Chinese operation panel)

  1. Paramètres techniques clés
ArticleValeur
ModèleATV71HU75N4Z
Moteur applicable7.5 kW 3-phase asynchronous motor
Courant nominal17 UN (typical at 380V)
Tension d'entrée3-phase AC 380~480 V
Mode de contrôleContrôle V/F + Sensorless vector control
Degré de protectionIP20 (monté sur armoire)
Standard FeaturesFiltre CEM intégré, braking unit, Chinese panel
  1. Application & Sélection

Applications typiques: Ventilateurs de climatisation centrale, pompes de circulation, water supply pumps, exhaust systems, CVC

Load Characteristic: Optimized for quadratic torque loads, outstanding energy-saving effect

Same-series replacement/upgrade:

One size smaller: ATV71HU55N4Z (5.5 kW)

One size larger: ATV71HU11N4Z (11 kW)

General replacement: VTT340, ATV610 series in the same power range for fans and pumps

  1. Installation & Entretien

Installation: Rail/screw mounting inside cabinet, air duct top inlet, sortie inférieure

Refroidissement: Natural air cooling; cabinet space reserved for heat dissipation recommended

Common protections: Surintensité, surcharge, surtension, sous-tension, surchauffe, stall protection

Complete ATV71 Series Model List & Replacement Options from Major Global Brands

  1. Full ATV71 Series Models (by Type & Pouvoir)

ATV71 is a Schneider high-performance general-purpose vector inverter, covering 0.37kW~630kW. It is discontinued and officially upgraded to ATV930/ATV630/ATV340 series.

1.1 Règle de dénomination du modèle (Review)

`ATV71` + `Type Code` + `Power Code` + `Voltage Code` + `Control Code` + `Configuration Code`

Code de type: HU=HVAC fan/pump; HD=General heavy-duty; HC=Enhanced coating (harsh environment); H0=Basic version

Power Code: par ex., 75=7,5 kW, 11=11kW, 15=15kW, etc..

Code de tension: N=3-phase 380~480V; M=3-phase 220~240V; Y=3-phase 500~690V

Control Code: 4=Vector control; 3=V/F control

Code de configuration: Z=Standard (CEM intégrée, braking unit, Chinese panel); D=Enhanced; X=Basic

1.2 Common Model List (by Power Range)

PouvoirHVAC Fan/Pump Type (HU)General Heavy-Duty (HD)Enhanced Coating (HC)
0.75kWATV71HU075N4ZATV71HD075N4ZATV71HC075N4
1.5kWATV71HU15N4ZATV71HD15N4ZATV71HC15N4
2.2kWATV71HU22N4ZATV71HD22N4ZATV71HC22N4
3kWATV71HU30N4ZATV71HD30N4ZATV71HC30N4
4kWATV71HU40N4ZATV71HD40N4ZATV71HC40N4
5.5kWATV71HU55N4ZATV71HD55N4ZATV71HC55N4
7.5kWATV71HU75N4Z (your model)ATV71HD75N4ZATV71HC75N4
11kWATV71HU11N4ZATV71HD11N4ZATV71HC11N4
15kWATV71HU15N4ZATV71HD15N4ZATV71HC15N4
18.5kWATV71HU18N4ZATV71HD18N4ZATV71HC18N4
22kWATV71HU22N4ZATV71HD22N4ZATV71HC22N4
30kWATV71HU30N4ZATV71HD30N4ZATV71HC30N4
37kWATV71HU37N4ZATV71HD37N4ZATV71HC37N4
45kWATV71HU45N4ZATV71HD45N4ZATV71HC45N4
55kWATV71HU55N4ZATV71HD55N4ZATV71HC55N4
75kWATV71HU75N4ZATV71HD75N4ZATV71HC75N4
90kWATV71HU90N4ZATV71HD90N4ZATV71HC90N4
630kWATV71HD63N4DATV71HC63N4D
  1. Cross-Reference Table for Major Global Brands (7.5kW Base)

2.1 Schneider Official Upgraded Models (Premier choix)

Modèle originalRecommended ReplacementCaractéristiques
ATV71HU75N4ZATV930HU75N4Contrôle vectoriel performant, compatible with old parameters, EcoStruxure smart architecture
ATV71HU75N4ZATV630HU75N4Optimized for fans & pompes, upgraded energy-saving algorithm
ATV71HU75N4ZATV340HU75N4Rentable, suitable for basic HVAC applications

2.2 Equivalent Models from Other International Brands

MarqueSérieModèle de remplacementMode de contrôleTension appropriée
SiemensSINAMIQUE G1206SL3224-0BE27-5UA0Contrôle vectoriel3-phase 380~480V
SiemensSINAMICS V206SL3210-5BE27-5UV0V/F + Vector3-phase 380~480V
ABBACS580ACS580-01-145A-4Contrôle direct du couple3-phase 380~480V
ABBACS380ACS380-040S-07A5-1Contrôle vectoriel3-phase 380~480V
MitsubishiFR-A840FR-A840-00163-2-60Contrôle vectoriel3-phase 380~480V
MitsubishiFR-F840FR-F840-00163-2-60Contrôle V/F3-phase 380~480V
RockwellPowerFlex 52525B-D017N104Contrôle vectoriel3-phase 380~480V
DanfossVLT AutomationDriveFC302P11KT4E20H2BXCDContrôle vectoriel3-phase 380~480V
FujiFRENIC-AceFRN0016E2S-4CContrôle vectoriel3-phase 380~480V
YaskawaGA700CIMR-GA2A0018ABAContrôle vectoriel3-phase 380~480V
  1. Points clés pour la sélection de remplacement
  2. Correspondance de puissance: Rated current of replacement ≥ 17A of original ATV71HU75N4Z (typical at 380V)
  3. Fonctions de contrôle: For fan/pump applications, prioritize models with PID, sleep/wake-up, contrôle multi-pompes
  4. Compatibilité d'installation: Match dimensions, cutout, cooling requirements with original equipment
  5. Migration des paramètres: ATV930/630 support direct parameter import from ATV71, reducing commissioning cost
  6. Capacité de surcharge: ATV71: 150% surcharge pendant 60s; verify equivalent rating when replacing
  7. Recommandations de sélection

Prioritize Schneider official upgraded models (ATV930/630): best compatibility, full technical support

HVAC fan/pump applications: Choose HU type first, then brand-specific HVAC-optimized drives (par ex., ABB ACS580-01, Siemens G120X)

Applications industrielles générales: HD type or general vector inverters; verify braking unit, EMC filter options