Parker PHS520S-02 Solenoid Pilot-Operated Pneumatic Valve - Contacteur,disjoncteur,onduleur solaire,compteur électrique,capteur,Encodeur,API

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

Parker PHS520S-02 Solenoid Pilot-Operated Pneumatic Valve - Contacteur,disjoncteur,onduleur solaire,compteur électrique,capteur,Encodeur,API

électrique/

Parker PHS520S-02 Solenoid Pilot-Operated Pneumatic Valve

PHS520S-02 PHS520: Série, 5-port pilot-operated pneumatic solenoid valve S: Célibataire, Single-solenoid, retour à ressort (energize for shift; de-energize for spring reset) -02: PT1/4 (G1/4) fil, inline threaded mounting, non-manifold base version Complete ordering example: PHS520S-02-24V-DL 24V: DC24V; 220V: AC220V D: DIN connector; DL: DIN connector with LED indicator; no marking = direct wire-out L: Lockable manual ...

  • Détails du produit

PHS520S-02

PHS520: Série, 5-port pilot-operated pneumatic électrovanne

S: Célibataire, Single-solenoid, retour à ressort (energize for shift; de-energize for spring reset)

-02: PT1/4 (G1/4) fil, inline threaded mounting, non-manifold base version

Exemple de commande complet: PHS520S-02-24V-DL

24V: DC24V; 220V: AC220V

D: DIN connector; DL: DIN connector with LED indicator; no marking = direct wire-out

L: Lockable manual override; no marking = non-locking manual override

Spécifications techniques de base

ArticleSpécification
Fonction de la vanne5/2-chemin, single‑solenoid spring return, internal pilot
MédiasAir comprimé (non‑lubricated acceptable)
Taille du portPT1/4 (P‑supply, A/B‑output); Exhaust R1/R2 PT1/8
Pression de fonctionnement0.15-0,9MPa (1.5‑9 bar)
Flow Cv1.0, Effective area ≈18 mm²
Temps de réponse≤20 ms
Température de fonctionnement+5~+60 ℃
Matériau du corpsAnodized aluminum; Joint: NBR nitrile rubber
Tension de bobineDC24V, AC110V, AC220V
Consommation d'énergieDC24V: 2.6 W; AC220V: 3.5 VA
Allowable Voltage Variation±10%
Classe de protectionIP65 (DIN connector properly fitted)
Classe d'isolationClasse F
Commande manuelleStandard: non‑locking push‑type; Optional L: lockable lever type
Fréquence de fonctionnement maximale5 cycles/s
Code SH8481804090

Caractéristiques du produit

  1. Internal pilot design, faible consommation d'énergie de la bobine, suitable for long-duration continuous energization, low risk of coil burnout
  2. Direct inline threaded mounting; compatible with PHS520-series manifold bases for multi-valve assembly
  3. PEC5-series coils can be individually removed and replaced, valve body reusable, faible coût d'entretien
  4. Independent exhaust ports, silencers can be fitted for noise reduction
  5. Certifié CE, widely used for cylinder directional control in packaging machinery, machine tools and automation production lines

Coil Compatibility

Valve body PHS520S-02 is supplied without coil. Order separate Parker PEC5-XXV-D / DL coils:

PEC5-24V-D: DC24V, DIN connector, pas de LED

PEC5-24V-DL: DC24V, DIN connector with LED indicator

PEC5-220V-DL: AC220V, DIN connector with LED

Domestic Equivalent Selection Reference

Match thread size, flow rate and outer mounting dimensions as much as possible

  1. Arctique: 4V210-08 (PT1/4, 5/2 mono-solénoïde, comparable flow)
  2. JELPC: 4V210-08
  3. CEM: EV520S-02 (highly compatible mounting & port dimensions for PHS520S-02)

Note: PHS520S-02 is pilot-operated; 4V210-08 is direct-pilot type. Differences exist in power consumption and internal construction. Prior to drop-in replacement, verify cylinder actuation speed and minimum working pressure.

Opération & Directives d'entretien

  1. L'alimentation en air doit être filtrée; recommend 40 μm filter-regulator unit. Prevent liquid water/oil from entering valve cavity.
  2. Never energize bare coil; coil must be assembled onto valve body.
  3. Preferred mounting orientation: coil upward or horizontal.
  4. Commande manuelle: Standard non-locking: press to test, auto-reset upon release. L-suffix lockable version: rotate to lock spool position.
  5. Dépannage: No LED light → check power supply; No shift when energized → verify supply pressure ≥0.15 MPa, inspect pilot orifice for debris blockage.

PHS520 Series Complete Model Coding Table

Full ordering format:

PHS520【Function Code】【Pilot Option】-【Port Code】-【Voltage】-【Wiring】-【Manual Override】

Example complete model: PHS520S-02-24V-DL-L

① Series: PHS520

5-port internal pilot pneumatic solenoid valve, rubber seal, Parker Korea origin

② Valve Body Function Code

CodeDescription de la fonction
S5/2-chemin, Single‑solenoid spring return (PHS520S‑02 is this variant)
D5/2-chemin, Double‑solenoid latching, pulse trigger, no spring return
C5/3‑way Center Closed (A/B ports blocked in center position)
E5/3‑way Center Exhaust (A/B ports exhausted in center position)
P.5/3‑way Center Pressure (A/B ports pressurized in center position)

③ Pilot Option (Suffixe facultatif)

No marking: Pilote interne (standard for most models)

X: External pilot, requires separate external pilot air supply, for vacuum / low-pressure applications, par exemple. PHS520SX-8

④ Port Specification (suffix after hyphen)

SuffixePort Description
-02Inline threaded, RC(TP)1/4; Exhaust Rc1/8; standalone threaded valve body
‑8Montage sur embase de collecteur, no external threads; mounts onto PHS520‑M multi‑station manifold, internal manifold air channels

⚠️ PHS520S-02 VS PHS520S-8 Key Comparison

  1. PHS520S-02: Inline threaded valve: Valve body has threaded ports for direct pipe connection, standalone operation without manifold.
  2. PHS520S-8: Manifold-mount valve: No external pipe threads, must install on PHS520-M-series manifold base. Designed for multi-valve banks, cannot accept direct pipe fittings.

Bobine, flow rating, pressure rating and coils are fully interchangeable between the two variants; PEC5-XXV-D/DL coils cross-fit 100%.

⑤ Coil Voltage

24V: DC24V (le plus courant)

110V: AC110V

220V: AC220V

⑥ Wiring Code

CodeWiring Form
No markingDirect wire‑out flying leads
FLDirect wire‑out + Indicateur LED
DDIN43650 connector, pas de LED
DLDIN connector, with LED indicator + suppression des surtensions, preferred for industrial field installation

⑦ Manual Override (Optional trailing suffix-L)

CodeManual Override Type
No markingNon‑locking push‑to‑test: press for test, auto‑reset; cannot hold spool position
LLockable lever override: rotate to mechanically lock spool position for maintenance & essai

Separate-order Coil Models (PEC5 Series)

Corps de vanne fourni sans bobine; coils must be ordered separately:

PEC5-24V-D: DC24V DIN connector, pas de LED

PEC5-24V-DL: DC24V DIN connector with LED

PEC5-220V-DL: AC220V DIN connector with LED

Bobines 100% interchangeable between PHS520-02 and PHS520-8 bodies.

Manifold Bases (for-8 manifold-mount valves)

PHS520-M N, N = number of stations:

PHS520-M2 (2-station), M3 (3-station) … M15; Blank-off plate: PHS520-BP-1

Common Selection Pitfalls Summary

  1. Do not confuse-02 inline threaded and-8 manifold-mount versions; -8 bodies cannot accept direct pipe threads.
  2. Suffix-X = external pilot. Do not select-X for standard cylinder control; external pilot air supply is mandatory, otherwise valve will not shift.
  3. 5/3-way valves (C/E/P) minimum working pressure 0.2 MPa, higher than 5/2-way valves at 0.15 MPa.
  4. Utilisé / second-hand valve inspection checklist:

No body cracks; manual override pushes and returns smoothly.

Pneumatic test at 0.4-0.5 MPa supply pressure; verify home position with power off; confirm shift upon energization, spring return upon de-energization.

DC24V coil resistance approx. 950-1100 Oh. Do not judge AC coil health by multimeter resistance; test by applying rated voltage.

Continuous exhaust port leakage indicates worn internal seals.

Frequently-used Complete Ordering Examples

  1. Stand-alone inline single-solenoid: PHS520S-02-24V-DL
  2. Manifold-mount single-solenoid with lockable manual override: PHS520S-8-24V-DL-L
  3. Double-solenoid inline version: PHS520D-02-24V-DL
  4. External-pilot manifold-mount single-solenoid: PHS520SX-8-24V-DL

Parker PHS520S-02 5/2-Way Single-Solenoid Solenoid Valve (Full Official Specifications)

Valve function: 5/2-chemin, internal pilot, single-solenoid spring return, inline threaded mounting (-02 = PT1/4 thread ports)

Pneumatic Performance

ArticleValeur
Valve Logic5/2-chemin, single‑solenoid spring return
ActionnementPilote interne (‑X suffix = external pilot)
MédiasAir comprimé, non‑lubricated or lubricated service
Pression de fonctionnement0.15~0.9 MPa (1.5‑9 bar)
Minimum Pilot Pressure0.15 MPa (spring cannot guarantee reliable shift below this threshold)
Port ThreadsP/A/B ports: TP(RC)1/4″; R1/R2 exhaust PT(RC)1/8″
Flow Coefficient Cv1
Zone de débit efficace18 mm²
Temps de réponse≤20 ms (energize shift; de‑energize spring return)
Fréquence de fonctionnement maximale10 cycles/s
Exhaust ConfigurationSeparate independent exhaust ports; silencers may be fitted
Durée de vie mécanique≥20 million cycles

Mécanique & Material Data

ArticleSpécification
Matériau du corpsAnodized aluminum alloy
ScellésNBR nitrile rubber
Commande manuelleStandard: non‑locking push‑type; Optional‑L: lockable lever type
Poids (body without coil)environ. 220 g; complete unit with DIN‑connector coil approx. 310 g
MontageDirect threaded inline mounting; also bracket‑mount via screw holes; NOT compatible with‑series‑8 manifolds
Vibration & Résistance aux chocs5‑200 Hz at 5G; Shock 30G
Température ambiante de fonctionnement+5℃ ~ + 60 ℃

Paramètres électriques (matched with PEC5 coils)

ArticleDC24VAC110VAC220V
Rated Power Consumption2.6 W4.0 VA3.5 VA
Allowable Voltage Deviation±10%±10%±10%
Classe d'isolationClasse FClasse FClasse F
Indice de protectionIP65 (DIN connector fully seated)IP65IP65
Wiring OptionsDirect flying‑lead / DIN43650 connector; DL variant includes LED indicator + suppression des surtensions
DC24V Coil DC Resistanceenviron. 950‑1100 Ω

⚠️ Valve body PHS520S-02 is supplied without coil. Coil part numbers: PEC5-24V-D / PEC5-24V-DL

Key Dimensional Data (mm)

Overall length (corps + bobine): 112

Largeur du corps: 40

Body height (excluding manual override): 42

Trous de montage: Φ4,5, hole center-to-center 60 mm

PT1/4 effective thread depth: 8 mm

Full Ordering Examples

PHS520S-02-24V-DL

PHS520S: 5/2-way single-solenoid spring return

-02: Inline PT1/4 threaded ports

24V: Bobine DC24V

DL: DIN connector with LED indicator and surge suppression

PHS520S-02-24V-DL-L: trailing-L = lockable manual override

Accessoires compatibles

  1. Silencieux: fits PT1/8 exhaust ports
  2. Bobines: PEC5-series, fully interchangeable between PHS520-02 and PHS520-8
  3. L-shaped mounting bracket: fastens to bottom of valve body

Fault Diagnosis Reference

  1. Continuous exhaust leakage: worn spool seals, aged NBR sealing components
  2. No shift when energized: confirm supply pressure ≥0.15 MPa; inspect pilot orifice for particulate blockage; verify coil receives rated voltage
  3. No spring-return on de-energization: sticking return spring, insufficient supply pressure

Code SH

8481804090 (Pneumatic solenoid valve)

PHS520S-02 vs PHS520S-8 Main Difference

PHS520S-02: Inline threaded valve, integral PT threads for direct pipe connection

PHS520S-8: Manifold-base valve, no pipe threads; must mount onto PHS520-M manifold base

Bobine, flow performance and coils are fully interchangeable; only mounting configuration differs.

Précédent:

Laisser une réponse

Laisser un message