Phoenix Contact UM-IC14/8DI/F/LA/S7 Interface Module - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

Phoenix Contact UM-IC14/8DI/F/LA/S7 Interface Module - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

électrique/

Phoenix Contact UM-IC14/8DI/F/LA/S7 Interface Module

This is a VARIOFACE series 8-channel passive digital input interface module manufactured by Phoenix Contact. Order number: 2902894. It is specially designed for Siemens S7-300/ET 200M systems, equipped with fuse protection and signal indicator lights, and adopts knife terminal wiring mode. Model Code Interpretation Code Meaning Detailed Description UM Product Series VARIOFACE Universal Interface Module ...

  • Détails du produit

This is a VARIOFACE series 8-channel passive digital input interface module manufactured by Contact Phénix. Order number: 2902894. It is specially designed for Siemens S7-300/ET 200M systems, equipped with fuse protection and signal indicator lights, and adopts knife terminal wiring mode.

  1. Interprétation du code modèle
CodeSignificationDescription détaillée
UMSérie de produitsVARIOFACE Universal Interface Module
IC14Type d'interface14-pin IC connector, compatible with Siemens ET 200M modules
8DEPUISChannel Configuration8 Digital Input channels
FProtection FeatureWith fuse protection, 1A pluggable fuse per channel
LEIndication FunctionBuilt-in signal indicators with independent LED status display for each channel
S7Compatibilité du systèmeDeveloped for Siemens S7-300/ET 200M controllers, compatible with 6ES7321 series input modules
  1. Paramètres techniques de base
Catégorie de paramètreTechnical IndexRemarques
Basic Characteristics
Numéro de commande2902894Exclusive official part code of Phoenix Contact
Type de produitPassive digital input interface moduleNo built-in power supply, powered by controller
Channel Quantity8 chaînesIndependent input without mutual interference
Mode de câblageKnife terminalSuitable for 0.14-1.5mm² wires for easy wiring
Méthode d'installationN.-É. 35/7.5 Rail DINStandard industrial mounting, largeur: only 12.5mm
Performances électriques
Tension nominale24À DCCompatible with wide voltage range: 19.2-26.4À DC
Input TypeSink/Source universalSupports PNP and NPN sensor signals
Courant d'entréeMax.. 8mA per channelStandard current range for PLC input
Fuse Specification1A per channel, enfichableProtection contre les surintensités, easy replacement
Temps de réponse≤1msFast signal acquisition
Insulation GradeFunctional insulationOvervoltage Category II, Degré de pollution 2
Mécanique & Paramètres environnementaux
Matériau du boîtierUL94 V0 flame-retardant plasticHigh safety and reliability
Classe de protectionIP20Applicable for installation inside control cabinets
Température de fonctionnement-20°C ~ +55°CSuitable for wide-temperature industrial environments
Température de stockage-40°C ~ +85°CAdapt to harsh storage conditions
PoidsEnviron. 82gLightweight design to save installation space
  1. Cross-brand Compatibility List
MarqueCompatible ModelSystème applicableDifférences
Siemens6ES7321-1BH02-0AA0S7-300/ET 200MPhoenix module has fuses and indicators, original Siemens version does not
Siemens6ES7321-1BL00-0AA0S7-300/ET 200M16 channels for Siemens, 8 channels for Phoenix Contact
Schneider ÉlectriqueBMXDRA8040Modicon M340System incompatible, adapter required
ABBDI810AC500Different interface types, conversion module needed
WeidmüllerUR20-14DI8/S7S7-300Spring terminals for Weidmüller, knife terminals for Phoenix Contact
  1. Full UM-IC14 Series Model List
ModèleDescriptionNuméro de commande.Principales caractéristiques
UM-IC14/8DI/F/LA/S78-channel digital input with fuse and indicators2902894Standard digital input module
UM-IC14/8DO/F/LA/S78-channel digital output with fuse and indicators2902896Passive output, 0.8A per channel
UM-IC14/8R/DO/1CO/DRY/S78-channel relay output, 1 change-over dry contact290289110A per channel, mechanical service life: 5×10⁶ times
UM-IC14/8R/DO/1CO/WET/D/S78-channel relay output, 1 change-over wet contact2904530Equipped with freewheeling diode, ideal for inductive loads
UM-IC14/8O/DO/1NO/WET/S78-channel solid state relay output29028953A per channel, free of mechanical wear
UM-IC14/8DI/LA/S78-channel digital input with indicators only2902893No fuse protection, rentable
  1. Défauts courants & Guide de dépannage
Phénomène de défautCauses possiblesSolutions
No input signal on channels1. Blown fuse1. Replace 1A fuse
2. Wrong wiring2. Check wiring polarity and tighten terminals
3. Defective sensor3. Verify sensor output
4. Loose module insertion4. Reinstall and lock the module firmly
Indicator light off while signal exists1. Damaged LED lamp1. Replace the module
2. Faulty indicator circuit2. Inspect internal indicator circuit
Simultaneous failure of multiple channels1. Abnormal common power supply1. Inspect 24V DC power supply
2. Poor bus connection of the module2. Check IC14 connector and clean contacts
Unstable signal / faux déclenchement1. Electromagnetic interference1. Add shielding measures and reliable grounding
2. Câblage lâche2. Retighten wiring terminals
3. Power fluctuation3. Stabilize power supply and install filters
Fuse frequently blown1. Excessive load current1. Confirm load parameters and replace matched module
2. Circuit short circuit2. Locate and eliminate short circuit points
3. Faulty sensor3. Replace damaged sensors
  1. Scénarios d'application & Cas industriels

Scénarios applicables

  1. Automatisation industrielle: Collect digital signals for Siemens S7-300/ET 200M systems, connect sensors, push buttons and limit switches
  2. Fabrication automobile: Monitor operating status of production line equipment, detect signals of stamping, welding and assembly stations
  3. Nourriture & Beverage Industry: Position detection and status feedback for packaging and filling lines, meeting food-grade environmental requirements
  4. Logistique & Entreposage: Signal acquisition for stackers and conveyors in automated warehouses, adapt to frequent start-stop operation
  5. Water Treatment Industry: Monitor pump stations and valves, suitable for humid working environments

Non-recommended Scenarios

  1. Unprotected outdoor environments: IP20 rating vulnerable to dust and moisture erosion
  2. Severe electromagnetic interference environments: Without dedicated shielding structure, extra protection is required
  3. Haute température & high humidity environments: Ambient temperature over +55°C or humidity above 95% will shorten module service life
  4. Severe vibration and impact occasions: Standard installation without anti-vibration reinforcement design

Cas d'application typiques

Cas 1: Auto Parts Production Line

An auto parts manufacturer adopts this module to connect S7-300 PLC with 20 proximity switches for stamping mold position and status monitoring. The built-in fuse effectively avoids PLC damage caused by sensor short circuit; indicator lights realize rapid fault diagnosis, raising maintenance efficiency by 40%.

Cas 2: Intelligent Warehousing System

An e-commerce logistics center applies this module in automated stereoscopic warehouses to connect limit switches, photoelectric sensors and safety door switches of stackers. The 8-channel design saves cabinet space; its compatibility with both PNP and NPN sensors simplifies equipment selection, achieving stable operation for 2 années consécutives.

  1. Air Transport Compliance & Certification Information
Certification TypeNuméro de certificat.Compliance StatusRemarques
Certification CE2902894-CECompliantConform to EU Low Voltage Directive 2014/35/EU
RoHS Certification2902894-RoHSCompliantMeet RoHS 2.0 Standard (2011/65/EU)
REACH Certification2902894-REACHCompliantFree of SVHC substances
Certification ULE254492CompliantComply with UL 508 industrial control equipment standard
Air Cargo ClassificationNon-restricted goodsCompliantNo built-in lithium battery and hazardous substances
Shipping StandardIATA/ICAO CompliantCompliantDelivered as general goods with no special restrictions
  1. Selection Mnemonic

Choose UM-IC14 for S7 input modules,

8 channels with fuses and indicators available;

Knife terminals ensure fast wiring,

Phoenix Contact part number: 2902894.

Supplementary Note about 2902888

Conclusion: 2902888 is NOT a product of Phoenix Contact.

It is the Element14 distributor part number for NorComp 15-pin right-angle female D-Sub connector, original model: 174-E15-213R461.

Phoenix Contact has a similar number 2900288, which refers to PLC-BPT-230UC/21-21 relay socket, please distinguish them clearly.

  1. Explication du code modèle
CodeSignificationDescription détaillée
2902888Distributor order numberExclusive product code of Element14 platform, not original factory model
174-E15-213R461Original factory modelComplete model of NorComp 174-E series standard D-Sub connector
174Code de sérieBasic D-Sub connector series for general industrial use
EType de montageRight-angle mounting to save PCB space
15Pin quantity15-pin high-density D-Sub layout (2 rows: 8 épingles + 7 épingles)
213Core specification2 = Female receptacle, 13 = 0.370 inch pitch (9.40mm), R = with positioning pin for anti-misplug
461Fonctionnalités supplémentaires4 = wired connection, 61 = standard plating (gold-plated contact area, tin-plated tail) and material configuration
  1. Paramètres techniques de base
Catégorie de paramètreTechnical IndexRemarques
Basic Features
Connector TypeStandard D-Sub female connector, right-angle typeComply with EIA-530 industrial standard
Pin Layout15 pins in high-density arrangement (8+7)Standard DB-15 interface layout
Mode de montagePCB through-hole welding0.370 inch (9.40mm) pitch, fit for standard PCB design
Performances électriques
Courant nominal5A per pinMax continuous current for industrial signal transmission
Tension nominale250V CA/CCDielectric test voltage: 1500V et (no breakdown within 1 minute)
Contact Resistance≤20mΩInitial value for low-loss signal transmission
Résistance d'isolation≥1000MΩ @500V DCEnsure reliable electrical isolation
Dielectric Strength1500V AC per minuteConform to IEC 60664-1 standard
Performances mécaniques
Matériel de contactCopper alloy, 30μin gold plating + tin platingGold-plated contact anti-oxidation, tin-plated tail easy for welding
Matériau du boîtierNickel-plated steelProvide EMI shielding and mechanical strength
Mating Cycle≥500 timesDurable under standard operation
Conditions environnementales
Température de fonctionnement-55°C ~ +125°CWide temperature range for harsh industrial environments
Classe de protectionIP00Non-sealed type, used inside control cabinets
Plage d'humidité5% ~ 95%Non-condensing environment, meet industrial standards
PoidsEnviron. 12gLightweight without extra load on PCB
  1. Cross-brand Alternative List
MarqueModèle alternatifScénario applicableDifférences
Contact Phénix2903777 (VIP-2/PT/D 9SUB/M)Only for D-Sub connectionNo 15-pin right-angle socket from Phoenix Contact, this is 9-pin module
Weidmüller178005400015-pin right-angle female D-Sub socketMechanically and electrically compatible, different terminal types
Siemens6ES7972-0BA12-0XA0Communication interface connectionSiemens is bus connector with different functions
Schneider ÉlectriqueBMXCPS3020Electrical parameter reference onlyIt is PLC power module instead of connector
OmronXW2Z-200J-B45Communication cable connectionOmron product is cable assembly, not PCB socket
  1. NorComp 174-E Series Full 15-pin Model List
ModèleDescriptionPrincipales caractéristiquesTypical Distributor No.
174-E15-213R46115-pin female, right-angle, wired typeStandard version without shielding2902888 (inquired part number)
174-E15-113R46115-pin male, right-angle, wired typeStandard version without shielding2902887
174-E15-213R46215-pin female, right-angle, wired with shieldEnhanced EMI shielding performance2902890
174-E15-113R46215-pin male, right-angle, wired with shieldEnhanced EMI shielding performance2902889
174-E15-213R46315-pin female, right-angle, dual-shield wired typeDouble shielding for high-frequency occasions2902892
174-E15-113R46315-pin male, right-angle, dual-shield wired typeDouble shielding for high-frequency occasions2902891
174-E15-213R46415-pin female, right-angle, high-current wired typeRated current up to 10A per pin2902894
174-E15-113R46415-pin male, right-angle, high-current wired typeRated current up to 10A per pin2902893
  1. Défauts courants & Dépannage
Phénomène de défautCauses possiblesSolutions
Mauvais contact / signal interruption1. Oxidation & contamination on pins1. Clean contact surface with isopropyl alcohol
2. Exceeded service life over 500 fois2. Replace the connector
3. Poor welding3. Reweld and check welding spots
Insulation failure / court-circuit1. Dust and moisture intrusion1. Clean and dry the product
2. Aging insulating material2. Replace the connector
3. Overvoltage damage3. Stabilize system voltage and add surge protection
Mechanical damage1. Excessive mating force over 50N1. Use professional tools to control mating force
2. Loosening caused by vibration & impact2. Reinforce installation and add anti-vibration measures
3. Deformed housing3. Replace housing or whole connector
Poor shielding / EMI interference1. Disconnected shielding layer1. Check integrity of shielding connection
2. Incorrect grounding2. Ensure reliable housing grounding with resistance below 1惟
Welding spot fracture1. Excess welding temperature1. Control welding temperature at 260掳C卤5掳C within 3 secondes
2. Excessive mechanical stress2. Add stress relief measures such as heat shrink tube
  1. Scénarios d'application & Cas typiques

Scénarios applicables

  1. Automatisation industrielle: PLC communication port, HMI connection, sensor signal transmission (S7-300/ET 200M system etc.)
  2. Équipement médical: Data interface for monitors and analyzers (medical certified models required)
  3. Test & Mesures: Connection for oscilloscopes, signal generators to ensure accurate signal transmission
  4. Équipement de communication: Serial port connection for modems and routers, support RS-232/422/485 protocols
  5. Electronique automobile: On-board diagnostic (OBD) interface, adapt to wide-temperature working environment

Non-recommended Scenarios

  1. De plein air & humid environments: IP00 rating without moisture-proof design
  2. High-frequency high-speed transmission: Limited bandwidth not suitable for signal above 100MHz
  3. Severe vibration & impact occasions: Standard type without shockproof structure, reinforced version required
  4. Nourriture & pharmaceutical clean workshops: Fail to meet hygiene standards, stainless steel housing type needed

Cas d'application typiques

Cas 1: PLC Control for Automotive Production Line

An automobile manufacturing plant uses this connector to connect S7-1200 PLC and HMI touch screen. Right-angle installation saves 30% cabinet space; gold-plated contacts guarantee long-term stable communication, realizing 3 years trouble-free operation and 50% coût d'entretien réduit.

Cas 2: Data Acquisition for Medical Devices

A medical device manufacturer applies this connector in blood analyzers to link sensor modules and main control boards. The 15-pin design meets multi-parameter synchronous transmission demands; its wide-temperature property adapts to lab environment changes, et CE & RoHS certifications satisfy medical industry standards.

  1. Air Transport Compliance & Attestation
Certification TypeNuméro de certificat.Compliance StatusRemarques
Certification CENC-174-E15-213R461-CECompliantConform to EU Low Voltage Directive 2014/35/EU
RoHS CertificationNC-174-E15-213R461-RoHSCompliantComply with RoHS 2.0 (2011/65/EU), lead-free and cadmium-free
REACH CertificationNC-174-E15-213R461-REACHCompliantFree of SVHC substances, conform to EU chemical regulations
Certification ULE486697CompliantMeet UL 1977 connector safety standard
Air Cargo ClassificationNon-restricted goodsCompliantNo lithium battery or dangerous goods, shipped as general cargo
Shipping RequirementIATA/ICAO ApprovedCompliantNo special packaging needed, storage temperature: -40°C ~ +85°C
  1. Selection Mnemonic

Three steps for D-Sub selection: confirm pin number 15, right-angle direction and female type;

Take electrical 5A/250V and mechanical 500 cycles into consideration, match actual working environment;

Belong to NorComp 174-E series, 2902888 is only Element14 order number.

Précédent:

Laisser une réponse

Laisser un message