Pilz 751104 Relais de sécurité - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

 Pilz 751104 Relais de sécurité - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

électrique/

Pilz 751104 Relais de sécurité

For cross-brand replacement of model 751104, the core differences lie in system integration compatibility, diagnostic functions, wiring methods and price ranges. Siemens is ideal for full Siemens-based systems; Schneider boasts powerful diagnostic functions; Omron features the most compact size; Phoenix Contact offers high cost performance; Weidmüller provides flexible wiring; Eaton delivers superior environmental adaptability; Wieland ...

  • Détails du produit

For cross-brand replacement of model 751104, the core differences lie in system integration compatibility, diagnostic functions, wiring methods and price ranges. Siemens is ideal for full Siemens-based systems; Schneider boasts powerful diagnostic functions; Omron features the most compact size; Phoenix Contact offers high cost performance; Weidmüller provides flexible wiring; Eaton delivers superior environmental adaptability; Wieland shares identical dimensions with Pilz products.

Pilz 751104 PNOZ s4 Compact Safety Relay

  1. Informations de base & Precise Model Definition

Numéro de commande: 751104

Modèle officiel: PNOZ s4 C 24VDC

Série: PNOZsigma s Compact Safety Relay

Official Manual: 21396-EN-21 (2026 Version)

Répartition du modèle

SegmentSignificationDescription
PNOZCore series code of Pilz safety relaysSafety control products complying with EN ISO 13849-1
sUltra-slim compact designHousing width: only 22.5mm, économiser de l'espace dans l'armoire
4Contact configuration codeStandard: 3 Normalement ouvert (NON) + 1 Normalement fermé (Caroline du Nord) safety contacts
CType de borneCage spring terminals (screwless); old model 750104 adopts screw terminals
24VCCTension de fonctionnement nominaleC.C 24 V, voltage range: 20.4-26.4V (-15%/+10%)
  1. Core Electrical Specifications (Official Authorized Data)
CatégorieSpécificationRemarques
Power Supply Parameters
Tension de fonctionnement nominaleC.C 24 VFluctuation range: 20.4~26.4V
Power Consumption Current≤120mANo-load condition
Inrush Current0.2UNPulse duration: 15MS
Caractéristiques d'entrée
Input ChannelsDual-channel safety input (S11-S12; S21-S22)Supports single/dual-channel wiring with inter-contact short-circuit detection
Courant d'entrée50mA per channelAt 24VDC
Mode de réinitialisationManuel / Automatic optionalAutomatic reset enabled by short-circuiting S34-S12
Caractéristiques de sortie
Safety Outputs3 NO contacts: 13-14, 23-24, 33-34Each group consists of 2 series-connected NO contacts for higher safety
Auxiliary Output1 NC contact: 41-42For fault indication and alarm signal
Rated Contact Current6UN (AC-1/DC-1)Resistive load at 240VAC / 24VCC
Thermal Rated Current4.5UNWhen 3 contacts operate simultaneously
Mécanique & Paramètres environnementaux
Temps de réponse≤15msKey safety-related index
Housing Width22.5mmStandard DIN rail mounting size
Classe de protectionIP20For cabinet internal installation
Température de fonctionnement-10℃ ~ +55℃Température de stockage: -25℃ ~ +70℃
Type de câblageCage spring clamp terminalWire cross-section: 0.2~2,5 mm²
Certifications de sécurité
Safety LevelEN ISO 13849-1: PL e, Cat.4Highest safety rating
Functional SafetyCEI 61508: SIL3Applicable to safety-critical systems
Certifications internationalesCE, TUV, UL, ASCGlobally approved
  1. Full PNOZ s Series Order Number List (Modèles grand public)
Numéro de commande.ModèleTensionConfiguration des contactsType de borneFonctionnalités principales
751101PNOZ s1 C24VCC1NON+1NCPince à ressortSingle-channel input, basic safety control
751102PNOZ s2 C24VCC3NON+1NCPince à ressortSingle-channel input, no short-circuit detection
751103PNOZ s3 C24VCC3NON+1NCPince à ressortDual-channel input, manual reset
751104PNOZ s4 C24VCC3NON+1NCPince à ressortDual-channel input, manual/automatic reset optional (mainstream model)
751105PNOZ s5 C24VCC4NON (2 instant + 2 delayed)Pince à ressortDelayed output, for equipment requiring braking delay
751106PNOZ s6 C24VCC3NO+1NC+1 semiconductor outputPince à ressortSolid-state output, suitable for high-speed switching
750104PNOZs424VCC3NON+1NCBorne à visObsolete model, replaced by 751104
751204PNOZ s4 C 24VDC24VCC3NON+1NCPince à ressortHigh-current upgraded version, rated contact current 10A
  1. Remplacement & Compatibility List

4.1 Old & New Model Replacement

Old ModelModèle de remplacementReplacement Description
750104751104Entièrement compatible; only terminal changed from screw to spring clamp, fonctions identiques & paramètres
750134751104Replacement for wide voltage version (24-240V CA/CC); confirm power supply type first

4.2 Competitor Equivalent Reference (Same-grade Safety Relays)

MarqueModèleAvantages comparatifs
Siemens3TK2825-1BB40Prix ​​inférieur, perfect for Siemens PLC system integration
SchneiderXPS-AV1110More comprehensive diagnostic functions, fit for complex safety systems
OmronG9SA-321-T075More compact size, ideal for ultra-narrow installation space
PILZ 751104High safety level (PL e/SIL3), flexible wiring, complete global certifications
  1. Scénarios d'application & Cas industriels

✅ Recommended Application Scenarios

  1. Emergency Stop Circuit: Connect series emergency stop buttons to cut off power of hazardous equipment instantly once triggered
  2. Safety Gate Monitoring: Detect open/closed status of protective gates and halt moving machine parts when gates open
  3. Photoelectric Safety Protection: Connect safety light curtains to stop equipment when personnel enter dangerous zones
  4. Two-hand Control: Applied to punching & bending machines; machine starts only with simultaneous two-hand operation to avoid misoperation
  5. Automated Production Line: Multi-device linkage safety control for zoned emergency stop
  6. Conditionnement / Impression / Injection Molding Machinery: Mold protection and safety interlock control

Typical Industry Applications

Fabrication automobile: Safety fence monitoring for welding robots

Electronic Assembly: Safety gate interlock for SMT production lines

Transformation des aliments: Emergency stop circuit for filling machines complying with food machinery safety standards

Équipement de machine-outil: Safety guard control for CNC machine tools

❌ Not Recommended Scenarios

Direct AC220V power supply (convert to 24VDC via transformer)

Outdoor open-air, humidité élevée (>95%RH) and heavy dust environments (only IP20 protection)

Direct switching of high-power main circuits (max 6A contact current; expand via contactors)

Explosion-proof areas (sans certification antidéflagrante)

Underwater installation or high-pressure washing environments

  1. Air Freight Compliance & Certification Info

6.1 Air Freight Compliance Confirmation

No built-in batteries or energy storage components: Classified as ordinary industrial electrical goods, non-dangerous goods

Air freight category: General cargo, no special shipping documents or marks required

Sea & land transportation: No restrictions, shipped as standard industrial products

6.2 Main Certifications & Official Numbers

AttestationNuméro de certificat.Applied Standard
CE0120-CPD-022DANS 60947-5-1, EN ISO 13849-1
TUV9706037CEI 61508: SIL3
ULE175588UL 508, UL 61010-1
ASCLR24536CSA C22.2 Non. 14
  1. Dépannage & Directives d'entretien

Défauts courants & Solutions

Phénomène de défautCause possibleInspection StepsSolutions
Power LED flashesLow/unstable input voltage1. Measure voltage between terminal A1-A21. Adjust voltage to 20.4-26.4V
2. Check power adapter2. Replace qualified power supply
Fault LED keeps onShort circuit or failure on input channels1. Check wiring of S11-S12 / S21-S221. Eliminate inter-contact short circuit
2. Test after disconnecting loads2. Replace damaged input components
In1/In2 LED flash alternatelyShort circuit between S12 and S221. Check dual-channel wiring1. Correct wrong wiring
2. Power off and restart2. Ensure channel insulation
No output signal1. Input not activated1. Check input status1. Activate input signals
2. Reset circuit open2. Verify S34-S12 reset loop2. Close reset circuit
3. Damaged output contacts3. Measure contact resistance3. Remplacer le relais
Accidental emergency stop1. Câblage lâche1. Tighten all terminals1. Retighten terminals
2. Electromagnetic interference2. Add shielding measures2. Use shielded cables
3. Power fluctuation3. Install filter modules3. Stabilize power quality

Calendrier d'entretien

Routine inspection: Check LED status and wiring tightness monthly

Periodic maintenance: Clean terminals and inspect contact wear every 6 mois

Service life suggestion: Replace every 8~10 years (adjust according to operating frequency)

  1. Selection Mnemonic

24V S4 model with 3NO+1NC spring terminals,

Dual-channel input with dual reset modes,

PL e & SIL3 high safety performance,

22.5mm slim size saves cabinet space,

Standard safety choice for industrial control!

Overview of Cross-brand Replacement for Pilz 751104 PNOZ s4 Compact Safety Relay

For cross-brand replacement of model 751104, the core differences lie in system integration compatibility, diagnostic functions, wiring methods and price ranges. Siemens fits full Siemens automation systems; Schneider has powerful diagnostics; Omron is ultra-compact; Phoenix Contact is cost-effective; Weidmüller supports diverse wiring; Eaton adapts well to harsh environments; Wieland is dimensionally identical to Pilz.

  1. Tableau de comparaison des paramètres de base
MarqueModèleNuméro de commande.Temps de réponseLargeurAvantages principaux
PILZPNOZ s4 C 24VDC751104≤15ms22.5mmComplete global certifications, flexible wiring
SIEMENS3TK2825-1BB403TK2825-1BB40≤15ms22.5mmStrong system integration, rich diagnosis
SCHNEIDERXPSUAF13APXPSUAF13AP≤15ms22.5mmExpandable, powerful diagnostic performance
OMRONG9SA-321-T075G9SA-321-T075≤15ms17.5mmUltra-slim structure
PHOENIXPSR-SPP-24DC/ESD/3X1/1X22904950≤15ms22.5mmPerformances à coût élevé, installation facile
WEIDMÜLLERSCS 24VDC P1SIL3DS MG38938670000≤15ms22.5mmHigh protection grade, harsh environment resistant
EATONMSR1270MSR1270≤15ms22.5mmWide temperature range, heavy industry oriented
WIELANDSNO 4083-24VSNO 4083-24V≤15ms22.5mmPin-to-pin replacement with Pilz
  1. In-depth Brand Analysis & Replacement Suggestions

2.1 Siemens 3TK2825-1BB40

Avantages principaux

Seamless connection with Siemens S7 series PLC for shared diagnostic data

Supports PROFIBUS / Communication PROFINET

Built-in current monitoring for output contact fault diagnosis

Conforme à la CEI 61508 SIL3 & EN ISO 13849-1 PL e

Conseils d'application

✅ Prioritize for full Siemens automated projects to cut integration costs

✅ Perfect for complex safety systems requiring PLC data interaction

❌ Less cost-effective in non-Siemens systems

2.2 Schneider XPSUAF13AP

Avantages principaux

Multi-level fault diagnosis with LED & text fault display

Modular design expandable up to 8 safety outputs

Built-in safety self-test function simplifies on-site commissioning

Compatible with Schneider safety bus system

Conseils d'application

✅ Ideal for production lines requiring detailed fault troubleshooting

✅ Best choice for multi-function integrated safety equipment

✅ Matches perfectly with Schneider Modicon PLC

2.3 Omron G9SA-321-T075

Avantages principaux

Ultra-narrow 17.5mm width saves 50% cabinet space

Low power consumption ≤80mA, suitable for battery-powered devices

Built-in surge suppression with strong anti-interference capability

Economical for mass installation

Conseils d'application

✅ Recommended for space-limited equipment such as small robots

✅ Suitable for large-quantity layout on assembly lines

❌ Not fit for frequent manual wiring operation due to narrow terminal spacing

2.4 Phoenix Contact PSR-SPP-24DC/ESD/3X1/1X2

Avantages principaux

Spring clamp wiring triples installation efficiency

Built-in electronic short-circuit protection extends contact service life

Hot-swap supported for easy on-site maintenance

Obvious price advantage with high cost performance

Conseils d'application

✅ Best choice for projects demanding fast installation & entretien facile

✅ Matches Phoenix distributed I/O systems perfectly

✅ Cost-saving option for mass-produced standard equipment

2.5 Weidmüller SCS 24VDC P1SIL3DS MG3

Avantages principaux

Standard IP20, partial models reach IP40 protection level

Supports 0.2~4mm² wide-range wire connection

All-round self-diagnosis for power, input and output faults

Excellent vibration resistance for rail transit & machinerie lourde

Conseils d'application

✅ Preferred for dusty & vibrating harsh working conditions

✅ Suitable for applications needing large cross-section wiring

✅ Unified wiring layout matched with Weidmüller terminal blocks

2.6 Eaton MSR1270

Avantages principaux

Wide working temperature range: -25℃~+70℃ for extreme environments

10A high rated current can directly drive small motors

Multi safety logic: arrêt d'urgence, safety gate, commande à deux mains

Complete global safety certifications

Conseils d'application

✅ Suitable for outdoor and non-air-conditioned workshop equipment

✅ Widely used in heavy industry and new energy industries

✅ Perfect alternative for high-current safety control demands

2.7 Wieland SNO 4083-24V

Avantages principaux

Fully consistent 22.5mm dimension with Pilz PNOZ s series for direct replacement

Identical terminal layout with no cabinet modification needed

Built-in contact welding detection function

15~20% lower price than Pilz original products

Conseils d'application

✅ First choice for Pilz system renovation & réduction des coûts

✅ Ideal for retrofitting projects retaining original cabinet layout

✅ Preferred alternative in mechanical manufacturing industry

  1. Key Factors for Cross-brand Selection
Selection FactorPoints clésRecommended Brands
Compatibilité du systèmeMatching degree with existing PLC & automation platformSiemens (S7), Schneider (Modicon), Omron (Sysmac)
Space LimitationAvailable installation space inside cabinetOmron (17.5mm), Pilz/Siemens/Schneider (22.5mm)
Diagnostic DemandFault diagnosis depthSchneider (haut), Siemens, Weidmüller
Wiring EfficiencyOn-site installation & maintenance convenienceContact Phénix (borne à ressort), Pilz 751104
Ambient ConditionTempérature, humidité, vibration levelEaton (wide temp), Weidmüller (anti-vibrations)
Cost BudgetOverall project cost controlContact Phénix, Wieland, Omron
Special Safety FunctionsDelay output, extended output etc.Schneider (extensible), Eaton (courant élevé)
  1. Replacement Implementation Rules & Remarques

4.1 Direct Replacement Feasibility

Physical Compatibility: All models except Omron are 22.5mm wide for direct DIN rail mounting

Compatibilité électrique: Uniform 24VDC power supply and 3NO+1NC output for direct wiring replacement

Functional Compatibility: All support dual-channel input and dual reset modes with identical safety standards

4.2 Replacement Precautions

  1. Reset Circuit: Automatic reset wiring definition varies by brand; adjust S34-S12 connection referring to official manuals
  2. Diagnostic Program: Reconfigure PLC diagnosis logic to adapt to new brand fault signal definition
  3. Certification Verification: Confirm alternative models meet all required project certifications (CE, UL, CSA etc.)
  4. Capacité de contact: Ensure rated contact current meets actual load demand (minimum 6A consistent with 751104)

4.3 Optimal Selection Scheme

Nouveaux projets: Select the same-brand safety relay as your automation control system for better compatibility

Renovation projects: Prioritize Wieland (dimension fully compatible) or Phoenix Contact (easy wiring)

Bulk replacement: Choose cost-effective Omron or Phoenix Contact

  1. Cross-brand Selection Mnemonic

Siemens excels in system integration,

Schneider leads in diagnosis function,

Omron owns the slimmest dimension,

Phoenix wins high cost attribution,

Weidmüller adapts tough condition,

Eaton fits wide temperature application,

Wieland replaces Pilz without variation,

Matching selection brings best operation!

Précédent:

Suivant:

Laisser une réponse

Laisser un message