Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

SCHNEIDER ATS48D88Q Soft Starter - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

onduleur solaire/compteur d'électricité/électrique/

SCHNEIDER ATS48D88Q Soft Starter

Model Code Interpretation Code Segment Description ATS48 Product series: Altistart 48 series soft starter, used for soft start and soft stop control of three-phase squirrel-cage asynchronous motors D Rated current factor: D=1.0, rated current is the base value without multiplier adjustment 88 Courant nominal: 88UN (at 40C ambient temperature) Q Voltage class: 3-phase 230~415V AC ...

  • Détails du produit

Interprétation du code modèle

Code SegmentDescription
ATS48Product series: Altistart 48 série démarreur progressif, used for soft start and soft stop control of three-phase squirrel-cage asynchronous motors
DRated current factor: D=1.0, rated current is the base value without multiplier adjustment
88Courant nominal: 88UN (at 40C ambient temperature)
QVoltage class: 3-phase 230~415V AC (Y=3-phase 208~690V AC)
  1. Paramètres techniques de base

Paramètres électriques

ArticleValeurDescription
Rated operating voltage230~415V AC, 50/60Hz3-phase power input
Rated operating current88UN (40C)Continuous operating current
Suitable motor power45kW (400V normal duty)Matching power for different voltages and applications
37kW (400V heavy duty)
22kW (230V normal duty)
18.5kW (230V heavy duty)
Starting currentNormal duty: 152UN (delta connection) / 88UN (line connection)Starting current limits for different connections
Heavy duty: 130UN (delta connection) / 75UN (line connection)
Control supply voltage220~415V AC, 50/60HzControl circuit supply
Protection functionsSurintensité, surcharge, phase loss, phase sequence, PTC, underload, surtension, sous-tension, etc..Comprehensive motor protection
IP ratingIP20Protection against finger contact and solid foreign objects >12mm

Physical Parameters

ArticleValeur
Dimensions (L×H×P)190mm × 290mm × 235mm
PoidsEnviron. 8.3kilos
MontageStandard 35mm DIN rail mounting
  1. Applications
  2. Industrial pumps: Water pumps, oil pumps, chemical process pumps, etc., to reduce water hammer during start-up
  3. Ventilateurs: Industrial fans, cooling tower fans, boiler induced draft fans, etc., to reduce mechanical shock
  4. Compressors: Air compressors, refrigeration compressors, etc., to extend service life
  5. Conveyors: Smooth starting to avoid material spillage
  6. General industry: Three-phase squirrel-cage asynchronous motors requiring soft start/stop control, up to 45kW (400V)
  7. Replacement Models

4.1 Schneider Same-Series Upgrade/Replacement

Modèle de remplacementCaractéristiquesApplication
ATS48D88YWide voltage version (208~690V)For higher voltage applications
ATS480D88YUpgraded version of ATS48 seriesFor higher performance and compatibility
ATS22D88QEconomic alternativeBasic soft start requirements with limited budget

4.2 Cross-Brand Functional Equivalents

MarqueModèleMatch Level
ABBPSE85-600-7085Un courant nominal, similar functions, fits 45kW motors
Siemens3RW4443-6BC4488Un courant nominal, démarreur progressif, full protection
DeltaMPS500-4545kW soft starter, suitable for industrial automation
  1. Principales fonctionnalités & Remarques

Fonctionnalités principales

Soft start modes: Current-limited start, voltage ramp start, current ramp start for various loads

Soft stop function: Linear deceleration stop to prevent pump dry running and water hammer

Built-in intelligent protection: Full motor protection, self-diagnosis and alarm output

Communication: Supports Modbus, CANopen, etc., for easy PLC integration

Installation & Remarques sur l'opération

  1. Température ambiante: -10°C ~ +40°C; derate above 40°C
  2. Ensure good ventilation; keep at least 50mm clearance above and below
  3. Control supply and main power must be switched on/off synchronously
  4. Match motor power to soft starter rating to avoid overload
  5. Regularly check cooling fan and terminal connections

Selection Table – Schneider ATS48 Series Q-Type Soft Starters (Including ATS48D88Q)

Application: Soft start/stop for three-phase squirrel-cage motors, 230~415V AC, 50/60Hz, IP20, 35mm rail DIN.

ModèleCourant nominal (40C)Motor Power (Normal/Heavy Duty)Dimensions (W*H*D)PoidsPower Loss (Full Load)
230V (kW)400V (kW)
ATS48D17Q17UN4-37.5/5.5160mm*290mm*235mm4.9kilos59W
ATS48D22Q22UN5.5/411/7.5160mm*290mm*235mm4.9kilos74W
ATS48D32Q32UN7.5/5.511-15160mm*290mm*235mm4.9kilos104W
ATS48D47Q47UN11-922/18.5160mm*290mm*235mm4.9kilos142W
ATS48D62Q62UN11-1530/22190mm*290mm*235mm8.3kilos201W
ATS48D75Q75UN18.5/1537/30190mm*290mm*235mm8.3kilos245W
ATS48D88Q88UN22/18.545/37190mm*290mm*235mm8.3kilos290W

Key Selection Notes

  1. Power matching rules

Normal duty: Pumps, les fans, convoyeurs (light starting)

Heavy duty: Compressors, crushers, mélangeurs; select by heavy-duty power

Exemple: ATS48D88Q fits 45kW (400V normal), 37kW (400V heavy)

  1. Taille & weight groups

Petit (D17Q~D47Q): 160mm de large, 4.9kilos, for small motors

Large (D62Q~D88Q): 190mm de large, 8.3kilos, better cooling for medium/high power

  1. Remplacement & upgrade suggestions

Voltage upgrade: Q (230~415V) → Y (208~690V), par ex., ATS48D88Q → ATS48D88Y

Performance upgrade: ATS48 → ATS480 series

Economic option: ATS22 series same current models

  1. Installation & thermal notes

All IP20; install in enclosed panel

Min. 50mm ventilation above/below

Derate 1% per °C above 40°C

Sync control and main power