(TeSys Deca Series) Quick Model Identification LC1D65AQ7C – 380V is an AC contactor from Schneider Electric’s TeSys Deca series. The model breakdown is as follows: Model Segment Description LC1 Contactor product category D TeSys Deca series (upgraded version of the original D series) 65 Rated operational current 65A (at 400V, AC‑3 category) A Coil type: ...

  • Détails du produit

(TeSys Deca Series)

  1. Quick Model Identification

LC1D65AQ7C – 380V is an AC contactor from Schneider Electric’s TeSys Deca series. The model breakdown is as follows:

Segment de modèleDescription
LC1Contactor product category
DTeSys Deca series (upgraded version of the original D series)
65Rated operational current 65A (at 400V, AC‑3 category)
UNCoil type: Alternating Current (CA)
Q7Coil voltage: 380V CA 50/60 Hz
CTermination type: Everlink terminals (replacing traditional screw terminals)
380VSupplementary note for coil voltage

Global Order Code: LC1D65AQ7C

Trade Alias: TeSys D 65A 3P 380V AC Contactor

  1. Core Technical Specifications
ArticleValeurRemarques
Rated Operational Current (AC‑3)65UN (at 400V)Controls a 30kW three‑phase asynchronous motor
Tension de fonctionnement nominale≤ 440V AC50/60Hz, three‑phase system
Main Pole Configuration3P. (3 NON, 3 Normalement ouvert)Standard for motor control
Contacts auxiliaires1 NON + 1 Caroline du NordBasic configuration, expandable
Tension de bobine380V CA 50/60 HzPick‑up: 70%–100% Uc; Drop‑out: 20%–75% Uc
Consommation électrique de la bobinePick‑up: 170Virginie, Holding: 20VirginieEnergy‑saving design
Durée de vie mécanique20 millions d'opérationsHigh‑reliability design
Durée de vie électrique (AC‑3)2 millions d'opérationsÀ charge nominale
DimensionsH=105mm, W=85mm, D=100mmCompact, space‑saving in panels
PoidsEnviron. 0.75kilosStandard configuration
Protection DegreeIP2XFinger‑safe, suitable for cabinet installation
Impulse Withstand Voltage6–8kVHigh insulation for industrial environments
Plage de température de fonctionnement-25°C à +70°CWide temperature range
MontageRail DIN standard de 35 mmCompatible with standard panel designs
  1. Applications

This contactor is widely used in industrial automation and power distribution systems:

  1. Contrôle du moteur: Départ, stopping and protection of pumps, les fans, compresseurs, convoyeurs, injection molding machines, air compressors, etc..
  2. Building Electrical Systems: Control of air conditioning units, ascenseurs, fire pumps, ventilation systems
  3. Power Distribution: Main or branch switching for lighting, electric heating and other non-motor loads
  4. Lignes de production automatisées: PLC-controlled motor circuits for remote automatic control
  5. Gestion de l'énergie: Used with soft starters and inverters to optimize motor starting and operation
  6. OEM Equipment: Control circuits for machine tools, machines d'emballage, printing equipment and other special machines
  7. Principales fonctionnalités

High Efficiency & Energy Saving: Holding power as low as 20VA, saving approx. 30% energy compared to conventional contactors

Fast Installation: Everlink terminals enable tool-free wiring, reducing installation time by about 30%

Performances fiables: Durée de vie mécanique 20 million, electrical life 2 million, exceeding industry standards

Safe Design: IP2X protection against electric shock; optimized arc extinguishing system

Adaptabilité environnementale: Operating temperature -25°C to +70°C, with “TH” treatment for high humidity

Flexible Expansion: Expandable up to 4 NON + 2 NC using auxiliary modules (par ex., Série LADN)

Green Certification: Green Premium product, compliant with RoHS and REACh

  1. Replacement Options

5.1 Remplacements d'origine Schneider

ModèleCaractéristiquesApplication
LC1D65AQ7Traditional screw terminal versionRetrofit, compatible with existing wiring
LC1D65AD7C220V AC coil versionDifferent control voltage requirements
LC1D65ANDDC coil version (60À DC)DC control circuits, better noise immunity
LC1D80AQ7C80A upgraded versionHigher power motors (37kW @ 400V)

5.2 Cross-Brand Alternatives

MarqueModèle de remplacementMatching Specs
ABBAF65-30-11-1165UN, 3P., 380V et, 1 NON + 1 Caroline du Nord
Siemens3RT2036-1BB4065UN, 3P., 380V et, 1 NON + 1 Caroline du Nord
Commutateur ChangshuCK3-65/3P65UN, 3P., 380V et, domestic alternative
ChintNXC-6565UN, 3P., 380V et, cost‑effective alternative
  1. Remarques
  2. Model Difference: LC1D65AQ7C is the upgraded replacement for LC1D6511, with improved performance and compatible mounting dimensions.
  3. Terminals: Suffix “C” indicates Everlink tool-free terminals, ideal for fast installation.
  4. Correspondance de charge: At AC-3, 65A corresponds to a 30kW motor at 400V; consider actual load type when selecting.
  5. Contacts auxiliaires: Standard 1 NON + 1 Caroline du Nord; add modules such as LADN02 / LADN04 for more contacts.
  6. Installation: Mount on 35mm DIN rail; allow 5mm clearance for heat dissipation.
  7. Protection contre les surtensions: Surge suppressors (par ex., RC snubbers) are recommended across the coil to extend service life.
  8. Référence de prix
ChannelGamme de prix (Tax Included)Remarques
Authorized Schneider Distributor¥450–600Genuine product with technical support
Industrial E‑commerce Platform¥400–550In stock, fast delivery
Used / Stock¥250–350Condition and remaining life to be inspected
Imported (Overseas Sourcing)$140–180 (≈ ¥1000)Including duties and shipping
  1. Recommandations de sélection
  2. New Projects: Prefer LC1D65AQ7C (Everlink version) for faster installation and easier maintenance.
  3. Retrofit: Direct replacement for LC1D6511 with fully compatible dimensions.
  4. Extreme Environments: Derate to approx. 80% rated current at temperatures above 50°C.
  5. Frequent Switching: For >10 operations per hour, select an AC-4 rated contactor or increase maintenance frequency.

Schneider LC1D Series Contactor Model List & Corresponding ABB Order Codes

  1. LC1D Series Naming Rules & Paramètres de base

1.1 Model Breakdown Rules

Segment de modèleDescriptionExemple
LC1Contacteur (3‑pole)LC1
DTeSys Deca series (upgraded D series)D
XXCourant nominal (AC‑3 at 400V)09=9A, 12=12A, 65=65A, 115=115A
A/DCoil type (A=AC, D=DC)A=AC coil, D=DC coil
XXCoil voltage codeQ7=380V AC, M7=220V AC, F7=110V AC, B7=24V AC, BD=24V DC
CTermination (Everlink tool‑free)C=Everlink, no C=screw terminal
Aux CodeConfiguration des contacts auxiliaires00=no aux, 11=1NO+1NC (standard), 02=2NO, 20=2NC

Standard Example: LC1D65AQ7C (65UN, 380V AC coil, Everlink, 1 NON + 1 Caroline du Nord)

1.2 Common Coil Voltage Codes

Tension de bobineAC CodeDC CodeRemarques
24VB7BD50/60Hz (CA), universal (CC)
48VE7ED
110VF7HD
220VM7LDMost common control voltage
380VQ7Three‑phase control circuits
12VADDC only
42VD7AC only
  1. Complete LC1D Series Model List (By Current Rating)

2.1 Low Current Range (9A–32A)

CurrentStandard Model (Bobine CA)Motor Power (400V)Aux ContactsCode de commande
9UNLC1D09AQ7C / LC1D09AM7C4kW1 NON + 1 Caroline du NordLC1D09AQ7C / LC1D09AM7C
12UNLC1D12AQ7C / LC1D12AM7C5.5kW1 NON + 1 Caroline du NordLC1D12AQ7C / LC1D12AM7C
18UNLC1D18AQ7C / LC1D18AM7C7.5kW1 NON + 1 Caroline du NordLC1D18AQ7C / LC1D18AM7C
25UNLC1D25AQ7C / LC1D25AM7C11kW1 NON + 1 Caroline du NordLC1D25AQ7C / LC1D25AM7C
32UNLC1D32AQ7C / LC1D32AM7C15kW1 NON + 1 Caroline du NordLC1D32AQ7C / LC1D32AM7C

2.2 Medium Current Range (40A–95A)

CurrentStandard Model (Bobine CA)Motor Power (400V)Aux ContactsCode de commande
40UNLC1D40AQ7C / LC1D40AM7C18.5kW1 NON + 1 Caroline du NordLC1D40AQ7C / LC1D40AM7C
50UNLC1D50AQ7C / LC1D50AM7C22kW1 NON + 1 Caroline du NordLC1D50AQ7C / LC1D50AM7C
65UNLC1D65AQ7C / LC1D65AM7C30kW1 NON + 1 Caroline du NordLC1D65AQ7C / LC1D65AM7C
80UNLC1D80AQ7C / LC1D80AM7C37kW1 NON + 1 Caroline du NordLC1D80AQ7C / LC1D80AM7C
95UNLC1D95AQ7C / LC1D95AM7C45kW1 NON + 1 Caroline du NordLC1D95AQ7C / LC1D95AM7C

2.3 High Current Range (115A–205A)

CurrentStandard Model (Bobine CA)Motor Power (400V)Aux ContactsCode de commande
115UNLC1D115AQ7C / LC1D115AM7C55kW1 NON + 1 Caroline du NordLC1D115AQ7C / LC1D115AM7C
150UNLC1D150AQ7C / LC1D150AM7C75kW1 NON + 1 Caroline du NordLC1D150AQ7C / LC1D150AM7C
205UNLC1D205AQ7C / LC1D205AM7C90kW1 NON + 1 Caroline du NordLC1D205AQ7C / LC1D205AM7C

2.4 DC Coil Model Examples

CurrentDC Coil ModelTension de bobineCode de commande
65UNLC1D65DBDC24À DCLC1D65DBDC
65UNLC1D65DLDC220À DCLC1D65DLDC
32UNLC1D32DBDC24À DCLC1D32DBDC
  1. Cross-Reference: LC1D Series ↔ ABB AF Series

Below is the precise matching list including ABB official order codes and key specifications.

Schneider LC1D ModelCourant nominalPower (400V)ABB EquivalentABB Order CodeMatching Specs
LC1D09AQ7C9UN4kWAF09-30-10-131SBL137001R13103P., 1NON+1NC, 100–250V coil
LC1D12AQ7C12UN5.5kWAF12-30-10-131SBL167001R13103P., 1NON+1NC, 100–250V coil
LC1D18AQ7C18UN7.5kWAF16-30-10-131SBL177001R13103P., 1NON+1NC, 100–250V coil
LC1D25AQ7C25UN11kWAF26-30-10-131SBL257001R13103P., 1NON+1NC, 100–250V coil
LC1D32AQ7C32UN15kWAF30-30-10-131SBL287001R13103P., 1NON+1NC, 100–250V coil
LC1D40AQ7C40UN18.5kWAF38-30-10-131SBL297001R13103P., 1NON+1NC, 100–250V coil
LC1D50AQ7C50UN22kWAF45-30-10-131SBL337001R13103P., 1NON+1NC, 100–250V coil
LC1D65AQ7C65UN30kWAF65-30-10-131SBL367001R13103P., 1NON+1NC, 100–250V coil
LC1D80AQ7C80UN37kWAF80-30-10-131SBL377001R13103P., 1NON+1NC, 100–250V coil
LC1D95AQ7C95UN45kWAF95-30-10-131SBL457001R13103P., 1NON+1NC, 100–250V coil
LC1D115AQ7C115UN55kWAF116-30-10-131SBL617001R13103P., 1NON+1NC, 100–250V coil
LC1D150AQ7C150UN75kWAF146-30-10-131SBL677001R13103P., 1NON+1NC, 100–250V coil
LC1D205AQ7C205UN90kWAF205-30-10-131SBL767001R13103P., 1NON+1NC, 100–250V coil
LC1D65DBDC65UN30kWAF65-30-10-011SBL367001R10103P., 1NON+1NC, 24V DC coil
LC1D65AQ765UN30kWAF65-30-10-111SBL367001R11103P., 1NON+1NC, 250–500V coil
  1. Modèles spéciaux & Expansion Options

4.1 Auxiliary Contact Modules

LC1D series can be expanded with LADN auxiliary modules:

Module ModelConfiguration des contactsApplicationCode de commande
LADN022 NONLC1D09 to LC1D205LADN02
LADN202 Caroline du NordLC1D09 to LC1D205LADN20
LADN044 NONLC1D09 to LC1D205LADN04
LADN404 Caroline du NordLC1D09 to LC1D205LADN40

4.2 4-Pole Contactors (LC2D Series)

4‑Pole ModelCorresponding 3‑Pole ModelCaractéristiquesCode de commande
LC2D65AQ7CLC1D65AQ7C4P. (4 NON), for 3P+N applicationsLC2D65AQ7C

4.3 Mechanically Interlocked Contactors

Interlocked ModelCombinationApplicationCode de commande
LC1D65AQ7C + LAD926102×LC1D65 interlockedReversible motor controlLC1D65AQ7C + LAD92610
  1. Sélection & Notes de remplacement
  2. Mounting Compatibility: Both LC1D and ABB AF mount on 35mm DIN rail with similar dimensions, direct replacement possible.
  3. Correspondance de tension de bobine:

Schneider Q7 (380V et) → ABB 250–500V coil (code 14)

Schneider M7 (220V et) → ABB 100–250V coil (code 13)

Schneider B7 (24V et) → ABB 24–60V coil (code 11)

  1. Load Category Adaptation:

AC-3 (motor loads): match rated current directly

AC-1 (charges résistives): may use one size smaller

  1. Terminal Selection:

Suffix “C”: Everlink tool-free terminals for speed

No “C”: traditional screw terminals for legacy systems

  1. Advantages of ABB AF Series:

Built-in surge protection, no extra RC needed

Wide-range coil (100–250V AC covers 220V / 380V)

Mechanical life up to 30 millions d'opérations

  1. Price Reference Ranges (Tax Included)
Current RangeSchneider LC1D PriceABB AF PriceDifference
9–32A¥200–450¥250–500ABB approx. 15–20% higher
40–65A¥400–600¥450–650ABB approx. 10–15% higher
80–115A¥600–900¥650–950ABB approx. 8–12% higher
150–205A¥900–1500¥950–1600ABB approx. 5–10% higher