- Positionnement du produit
SMC SY3000 series miniature 5/2-way single-coil pilot-operated solenoid valve.
Designed specifically for high-frequency switching, suitable for small cylinder control.
Widely applied in pneumatic automation, équipement électronique, packaging machinery and other industries.
- Définition du code modèle (SY3220-5G-C4)
| Segment | Code | Description | Optional Configuration |
| SY | SY | SMC SY series pilot-operated 5-way solenoid valve | Fixé |
| 3 | 3 | Size code: 3000 series miniature body (width 10mm) | 3=Mini, 5=Medium, 7=Large, 9=Extra Large |
| 2 | 2 | Type de fonction: 5/2-way | 2=5/2-way, 3=5/3-way |
| 20 | 20 | Structure: Single-coil + manifold base mounting | 20=Single-coil, 40=Dual-coil |
| 5 | 5 | Tension de bobine: DC24V | 4=AC110V, 5=DC24V, 6=AC220V |
| G | G | Type de câblage: Direct outlet type (lead type, cable length 300mm) | G=Direct outlet, LZ=Socket with indicator, LD=Socket with indicator + diode |
| C4 | C4 | Taille du port: φ4mm push-in fitting | C4=φ4mm, C6=φ6mm, M5=M5 thread |
- Main Technical Specifications
| Catégorie | Paramètre | Détails |
| Basic Characteristics | Valve Type | 5/2-way, Single-coil, Pilote interne, Elastic seal |
| Working Medium | Air comprimé (Lubrication optional; ISO VG32 lubricant recommended) | |
| Type de montage | Manifold base mounting | |
| Pressure Ratings | Operating Pressure | 0.15~0.7 MPa |
| Proof Pressure | 1.0 MPa | |
| Guaranteed Withstand Pressure | 1.5 MPa | |
| Electrical Ratings | Tension nominale | DC24V |
| Fluctuations de tension | ±10% | |
| Consommation d'énergie | Standard: 2.5W; Économie d'énergie: 0.1W (with power-saving circuit) | |
| Classe de protection | IP40 | |
| Flow Characteristics | Effective Cross-sectional Area | 1.1 mm² |
| Max Flow Rate | 196 NL/min @ 0.5MPa | |
| Environmental Ratings | Ambient / Medium Temperature | -5℃~+50℃ (Non-freezing) |
| Humidité | 35%~85%RH | |
| Physical Parameters | Valve Body Width | 10mm (SY3000 series standard width) |
| Poids | Environ. 60g (including coil) | |
| Piping Method | Front piping (push-in fitting) |
- Standard Accessories List
| Nom de l'accessoire | Spécification | Qty | Remarques |
| Solenoid Valve Main Body | SY3220-5G-C4 | 1 pc | Includes coil, valve body, pilot valve |
| Outlet Cable | 300mm, 2-core | 1 pc | Standard for G-type direct outlet |
| Mounting Gasket | For SY3000 series | 1 pc | Manifold sealing |
| Mounting Screws | M3×8mm | 2 pcs | Fix valve to manifold |
| Instruction Manual | Électronique / Paper Version | 1 copy | Including installation, entretien & dépannage |
- SY3220 Series Full Model List (Common Types)
Modèle Tension Type de câblage Taille du port Caractéristiques SY3220-5G-C4 DC24V Direct outlet φ4mm Modèle standard, high-frequency switching SY3220-5G-C6 DC24V Direct outlet φ6mm High flow type SY3220-5LZ-C4 DC24V Socket with indicator φ4mm Visible status, easy diagnosis SY3220-5LD-C4 DC24V Socket with indicator + diode φ4mm Reverse polarity protection, protection des circuits SY3220-4G-C4 AC110V Direct outlet φ4mm Compatible with AC110V control system SY3220-6G-C4 AC220V Direct outlet φ4mm Compatible with AC220V control system SY3220-5G-M5 DC24V Direct outlet M5 thread Thread connection type SY3220-5GUE-C4 DC24V Direct outlet with indicator + protection contre les surtensions φ4mm Advanced protection type Compatible Manifold Models
| Manifold Model | Number of Stations | Taille du port | Caractéristiques |
| SS5Y3-01-01 | 1-station | C4/C6/M5 | 1-station manifold |
| SS5Y3-02-02 | 2-station | C4/C6/M5 | 2-station manifold |
| SS5Y3-05-05 | 5-station | C4/C6/M5 | 5-station manifold |
| SS5Y3-10-10 | 10-station | C4/C6/M5 | 10-station manifold |
| SS5Y3-20-20 | 20-station | C4/C6/M5 | 20-station manifold |
| SS5Y3-05-05D | 5-station | C4/C6/M5 | With DIN rail mounting |
- Concurrent & Cross-Brand Replacement Chart
| Marque | Modèle | Correspondance des spécifications | Core Difference | Interchangeabilité |
| SMC | SY3220-5G-C4 | 100% | Original authentique, qualité fiable, prix plus élevé | — |
| Arctique | 4V210-06 | 90% | 30% Prix inférieur, slightly lower flow | Same mounting holes, direct interchangeable |
| Mindman | MVSC-220-4E1 | 90% | Similar response speed, moderate price | Dimensions de montage compatibles |
| Festo | VUVS-L20-M52-AD-G14-F8 | 85% | Prix plus élevé, Protection IP65 | Requires adapter plate |
| MRC | 4F210-08 | 85% | Japanese quality, moderate price | Same mounting holes |
- Lignes directrices de sélection & Règles de remplacement
Conseils de sélection
Three key factors for SY3220 selection: tension, wiring and port size;
5 stands for 24V, G for direct wire outlet;
C4 for Φ4 tube, C6 for Φ6 tube;
20 for single-coil, 40 for dual-coil match;
10mm miniature body, manifold mounting saves space.
Selection Decision Tree
- Tension de contrôle: Choose 5 for DC24V, 4 for AC110V, 6 for AC220V
- Type de câblage: Fixed installation → G (direct outlet); Frequent replacement → LZ/LD (socket type)
- Taille du port: Low flow → C4 (Φ4mm); High flow → C6 (Φ6mm)
- Mode de contrôle: Single-acting → 20 single-coil; Double-acting → 40 dual-coil
- Montage: Manifold mounting → Standard type; Independent mounting → Model with F1 bracket
Recommandations de remplacement
Budget limited: Choose Airtac 4V210-06, 30% cost down, sufficient performance for most working conditions
Frequent maintenance: Select LZ/LD socket type for fast coil replacement and less downtime
Higher flow required: Upgrade to SY5220 series (medium body, effective area 2.8mm²)
Environnement difficile: Choose UE suffix model (with indicator + protection contre les surtensions) for higher reliability
- Domaines d'application typiques
- Electronic Equipment: Small cylinder drive, automatic assembly line, PCB conveying & positioning
- Machines d'emballage: Label attaching, film tension control, packaging sealing cylinder
- Équipement médical: Pneumatic control of analytical instruments, sample conveying mechanism
- Automation Production Line: Jig & fixture positioning, small manipulator joint control
- Transformation des aliments: Small pneumatic actuator, sorting mechanism control
- Key Operation & Points d'entretien
- Avant l'installation: Ensure medium cleanliness (5μm filter recommended) to prevent seal damage by impurities
- Instructions d'installation: Follow the flow arrow on valve body; reverse installation is prohibited
- Montage sur collecteur: Use sealing gasket, tighten screws evenly (torque 0.5~0.7N·m)
- Cycle d'entretien: Inspect seals every 6 mois; replace O-rings annually
- Dépannage: No action → Check in sequence: Voltage → Air pressure → Coil → Pilot valve
SMC SY Series Solenoid Valve Complete Model List & Guide de sélection
- Classement des séries & Naming Rule Overview
1.1 Series Specification Classification (by Body Size & Couler)
| Code de série | Body Width | Effective Area | Max Flow | Suitable Cylinder | Application typique |
| SY3000 | 10mm | 1.1m㎡ | 196NL/min | φ6~φ20 | Mini cylinder, contrôle de précision |
| SY5000 | 15mm | 2.8m㎡ | 470NL/min | φ25~φ40 | Small cylinder, general automation |
| SY7000 | 20mm | 5.2m㎡ | 860NL/min | φ50~φ63 | Medium cylinder, production line |
| SY9000 | 30mm | 11.0m㎡ | 1780NL/min | φ80~φ125 | Large cylinder, high flow system |
1.2 Règle de dénomination complète (Exemple: SY3220-5G-C4)
| Segment | Code | Signification | Optional Configuration |
| SY | SY | Series prefix | Fixé |
| 3/5/7/9 | 3 | Size code | 3=SY3000, 5=SY5000, 7=SY7000, 9=SY9000 |
| 2月3日 | 2 | Code de fonction | 2=5/2-way, 3=5/3-way |
| 20/40/30/31/32 | 20 | Mode de contrôle | 20=Single-coil, 40=Dual-coil, 30=Closed center, 31=Exhaust center, 32=Pressure center |
| 2005/4/6 | 5 | Tension de bobine | 4=AC110V, 5=DC24V, 6=AC220V |
| G/LZ/LD/UE | G | Type de câblage | G=Direct outlet, LZ=Socket with indicator, LD=Socket with indicator+diode, UE=Indicator+surge protection |
| C4/C6/M5 | C4 | Taille du port | C4=φ4mm push-in, C6=φ6mm push-in, M5=M5 thread |
| -Q | -Q | Attestation | Q=CE certified (facultatif) |
- Full Standard Model List By Series
2.1 SY3000 Series (Mini, 10mm Width)
5/2-way Single-coil (Taper 20)
| Modèle | Tension | Type de câblage | Taille du port | Caractéristiques |
| SY3220-4G-C4 | AC110V | Direct outlet | φ4mm | Modèle standard |
| SY3220-4G-C6 | AC110V | Direct outlet | φ6mm | Haut débit |
| SY3220-4LZ-C4 | AC110V | Socket with indicator | φ4mm | Status visible |
| SY3220-5G-C4 | DC24V | Direct outlet | φ4mm | Most commonly used |
| SY3220-5G-C6 | DC24V | Direct outlet | φ6mm | High flow common |
| SY3220-5LZ-C4 | DC24V | Socket with indicator | φ4mm | Status visible |
| SY3220-5LD-C4 | DC24V | Socket with indicator+diode | φ4mm | Reverse polarity protection |
| SY3220-5G-M5 | DC24V | Direct outlet | M5 thread | Thread connection |
| SY3220-5GUE-C4 | DC24V | Direct outlet+indicator+surge protection | φ4mm | Advanced protection |
| SY3220-6G-C4 | AC220V | Direct outlet | φ4mm | AC220V system compatible |
5/2-way Dual-coil (Taper 40)
| Modèle | Tension | Type de câblage | Taille du port |
| SY3240-5G-C4 | DC24V | Direct outlet | φ4mm |
| SY3240-5LZ-C4 | DC24V | Socket with indicator | φ4mm |
| SY3240-5G-C6 | DC24V | Direct outlet | φ6mm |
5/3-way (30/31/32 Taper)
| Modèle | Type de contrôle | Tension | Type de câblage | Taille du port |
| SY3330-5G-C4 | Closed Center | DC24V | Direct outlet | φ4mm |
| SY3331-5G-C4 | Exhaust Center | DC24V | Direct outlet | φ4mm |
| SY3332-5G-C4 | Pressure Center | DC24V | Direct outlet | φ4mm |
2.2 SY5000 Series (Moyen, 15mm Width)
5/2-way Single-coil (Taper 20)
| Modèle | Tension | Type de câblage | Taille du port |
| SY5220-5G-C4 | DC24V | Direct outlet | φ4mm |
| SY5220-5G-C6 | DC24V | Direct outlet | φ6mm |
| SY5220-5LZ-C6 | DC24V | Socket with indicator | φ6mm |
| SY5220-5LD-C6 | DC24V | Socket with indicator+diode | φ6mm |
| SY5220-5G-M5 | DC24V | Direct outlet | M5 thread |
5/2-way Dual-coil (Taper 40)
| Modèle | Tension | Type de câblage | Taille du port |
| SY5240-5G-C6 | DC24V | Direct outlet | φ6mm |
| SY5240-5LZ-C6 | DC24V | Socket with indicator | φ6mm |
| SY5240-5LD-C6 | DC24V | Socket with indicator+diode | φ6mm |
5/3-way (30/31/32 Taper)
| Modèle | Type de contrôle | Tension | Type de câblage | Taille du port |
| SY5330-5G-C6 | Closed Center | DC24V | Direct outlet | φ6mm |
| SY5331-5G-C6 | Exhaust Center | DC24V | Direct outlet | φ6mm |
| SY5332-5G-C6 | Pressure Center | DC24V | Direct outlet | φ6mm |
2.3 SY7000 Series (Grand, 20mm Width)
| Modèle | Fonction | Type de contrôle | Tension | Type de câblage | Taille du port |
| SY7220-5G-C6 | 5/2-way | Single-coil | DC24V | Direct outlet | φ6mm |
| SY7240-5G-C6 | 5/2-way | Dual-coil | DC24V | Direct outlet | φ6mm |
| SY7330-5G-C6 | 5/3-way | Closed Center | DC24V | Direct outlet | φ6mm |
| SY7331-5G-C6 | 5/3-way | Exhaust Center | DC24V | Direct outlet | φ6mm |
| SY7332-5G-C6 | 5/3-way | Pressure Center | DC24V | Direct outlet | φ6mm |
2.4 SY9000 Series (Extra Large, 30mm Width)
| Modèle | Fonction | Type de contrôle | Tension | Type de câblage | Taille du port |
| SY9220-5G-C6 | 5/2-way | Single-coil | DC24V | Direct outlet | φ6mm |
| SY9240-5G-C6 | 5/2-way | Dual-coil | DC24V | Direct outlet | φ6mm |
| SY9330-5G-C6 | 5/3-way | Closed Center | DC24V | Direct outlet | φ6mm |
| SY9331-5G-C6 | 5/3-way | Exhaust Center | DC24V | Direct outlet | φ6mm |
| SY9332-5G-C6 | 5/3-way | Pressure Center | DC24V | Direct outlet | φ6mm |
- Special Specification Models (Common Derivatives)
3.1 With Mounting Bracket (Suffix F1)
For independent mounting, only available for 5/2-way single-coil models
SY3220-5G-C4-F1
SY5220-5G-C6-F1
SY7220-5G-C6-F1
3.2 CE Certified Model (Suffix -Q)
Compliant with EMC & Low Voltage Directive, widely used for European export
SY3220-5G-C4-Q
SY5220-5G-C6-Q
SY7220-5G-C6-Q
3.3 External Pilot Type (Suffix -P)
Suitable for vacuum or low-pressure environment (0~0,7MPa)
SY3220-5G-C4-P
SY5220-5G-C6-P
3.4 Clean Room Version (Suffix -C)
Suitable for Class 100 clean environment
SY3220-5G-C4-C
SY5220-5G-C6-C
- Compatible Manifold Models (Universel pour toutes les séries)
| Manifold Model | Applicable Series | Number of Stations | Taille du port | Caractéristiques |
| SS5Y3-01-01 | SY3000 | 1-station | C4/C6/M5 | 1-station manifold |
| SS5Y3-05-05 | SY3000 | 5-station | C4/C6/M5 | 5-station manifold |
| SS5Y5-05-05 | SY5000 | 5-station | C4/C6/M5 | 5-station manifold |
| SS5Y7-05-05 | SY7000 | 5-station | C4/C6/M5 | 5-station manifold |
| SS5Y3-10-10D | SY3000 | 10-station | C4/C6/M5 | 10-station with DIN rail |
| SS5Y5-20-20 | SY5000 | 20-station | C4/C6/M5 | 20-station manifold |
- Selection Mnemonic
Five key points for SY selection: série, fonction, tension;
3=Mini,5=Medium,7=Large,9=Extra Large;
2=5/2-way,3=5/3-way remember clearly;
20=Single-coil,40=Dual-coil;
30=Closed,31=Exhaust,32=Pressure center;
5=24V,G=direct wire outlet;
C4 for Φ4,C6 for Φ6 tube;
Manifold mounting saves space, add F1 for standalone installation;
Add -Q for CE, add -P for external pilot.
- Core Selection Decision Tree
- Flow Demand: Mini cylinder → SY3000; Small → SY5000; Medium → SY7000; Large → SY9000
- Mode de contrôle: Single-acting → Single-coil(20); Reciprocating → Dual-coil(40); Mid-stop → 5/3-way(30/31/32)
- Voltage Match: DC24V→5; AC110V→4; AC220V→6
- Wiring Preference: Fixed installation→G; Frequent replacement→LZ/LD
- Taille du port: Low flow→C4; High flow→C6; Thread→M5
- Montage: Manifold→Standard; Independent→Model with F1 bracke
- Cross-Series Replacement Reference
| Modèle original | Remplacement de mise à niveau | Downgrade Replacement | Replacement Reason |
| SY3220-5G-C4 | SY5220-5G-C6 | — | Upgrade when flow insufficient |
| SY5220-5G-C6 | SY7220-5G-C6 | SY3220-5G-C6 | Cylinder upsize / downsize |
| SY7220-5G-C6 | SY9220-5G-C6 | SY5220-5G-C6 | High flow demand / cost optimization |
Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires















NH42-63-318x560.png)