Grundfos DDE 6-10 B-PP/E/C-X-31I001FG Diaphragm Dosing Pump
Materiale n.: 97720906|Grundfos SMART Digital DDE Economy Digital Diaphragm Dosing Pompa (Stepper Motor Driven)
Scomposizione del codice modello
DDE 6-10 B-PP/E/C-X-31I001FG
- DDE: Serie, economy digital dosing pump (modello base, differs from premium DDA/DDC)
- 6: Max flow rate 6 L/h
- 10: Max working pressure 10 sbarra
- B: Control version = Basic, manual adjustment + pulse signal input control
- PP: Pump head material = Polypropylene
- E: Seal material = EPDM (ethylene propylene diene monomer, resistant to water, weak acids & weak alkalis)
- C: Ball material = Ceramic
- X: Valve type = Standard double ball valve (non-spring-loaded)
- 31I001: Voltaggio / regione / connection code: 230V50Hz, I = Australia & New Zealand specification, 4/6mm hose connection
- F.G: Cable and certification configuration code
Dati tecnici principali
Max flow: 6 L/h; Min flow: 6 mL/h
Turn-down ratio: 1:1000, logarithmic adjustment knob 0.1~100% continuous regulation
Guidare: Stepper motor, full-stroke operation, stable dosing even with aerated media
Diaframma: Solid PTFE diaphragm
Precisione di ripetizione: ≤5%
Classe di protezione: IP65 / NEMA 4X
Max medium viscosity: 50 mPa·s
Built-in air vent valve for easy priming
Modalità di controllo: Local manual, external pulse input (dividable)
Certificazioni: CE, CSA-US, NSF61, EAC, RCM
Applicazioni tipiche
Trattamento dell'acqua (raw water, acque reflue, acqua della caldaia, circolazione dell'acqua di raffreddamento), RO & ultrafiltration, swimming pools, light chemical dosing, sodium hypochlorite, acido & alkali dosing (subject to EPDM chemical compatibility)
Nota: EPDM is not suitable for strong oxidants, concentrated chlorine or aromatic solvents. For high-chlorine applications, select V (FKM) versione.
Equivalent Series Reference (per la selezione & sostituzione)
DDE 6-10 B-PP/V/C-X-31I001FG: PP pump head + FKM seals (sodium hypochlorite resistant)
DDE 6-10 B-PVC/E/C-X-31I001FG: PVC pump head + Guarnizioni in EPDM
DDE 6-10 B-PV/T/C-X-31I001FG: PVDF pump head + PTFE seals (heavy corrosion)
Accessori opzionali (Installation Kit)
Foot valve, injection valve, PE discharge tubing, PVC suction tubing, vent tubing, compression fittings (4/6mm hose)
Spare Parts List for DDE 6-10 B-PP/E/C-X-31I001FG (97720906)
Pump configuration: PP pump head + Guarnizioni in EPDM + ceramic ball valves (SD-S-1-PP/E/C-2, S-series for 6~9L/h flow range)
Complete Repair Kit (Il più popolare, Full Set)
97751105|Pump Head Repair Kit SD-S-1-PP/E/C-2
Contains:
- PTFE composite main diaphragm
- Suction valve assembly (ceramic ball + EPDM seat seal)
- Discharge valve assembly (ceramic ball + EPDM seat seal)
- Pump head O-rings and small sealing gaskets
- Fixing screws, shims and air vent components
Compatible with DDE 6-10 and equivalently configured DDA 6–9L/h, PP/E/C combination
Promemoria: Grundfos S-series (≤15L/h) does not supply loose individual balls or diaphragms as standalone OEM part numbers. Factory supply prioritizes complete valve kits or diaphragm+valve kits; loose single parts on the market are mostly aftermarket.
Split Kits (Separate Procurement If Required)
- Valve Kit (aspirazione + discharge valves only, no diaphragm)
Codice: SD-S-PP/E/C-2 valve assembly (8-digit material number to be retrieved via Grundfos channel using pump PN 97720906)
Contenuto: 2 sets of valve assemblies (Al₂O₃ ceramic ball + EPDM valve seals)
- Diaphragm Only Kit (PTFE diaphragm only, no valves)
Codice: SD-S-1-PP diaphragm kit, also retrieved by pump serial/material number
Material Breakdown (Cross-check for replacements)
Diaframma: PTFE faced diaphragm with support flange
Valve ball: Al₂O₃ alumina ceramic ball
Valve seat O-ring / main pump head O-ring: EPDM (E code)
Pump head body: Polipropilene (PP)
If upgraded to sodium hypochlorite resistant version (V=FKM), repair kit PN will change and cannot be interchanged.
Cross-reference for different material sets (stocking reference)
PP/V/C (FKM seal for chlorine): Different repair kit PN from 97751105
PVDF/T/C (PTFE seal for heavy corrosion): Separate SD-S-PVDF/T/C-2 valve kit
PVC/E/C: Dedicated repair kit PN for PVC pump head variant
Grundfos DDE 6-10 B-PP/E/C-X-31I001FG Troubleshooting Guide
Applicable to DDE economy digital diaphragm dosing pump, PP pump head + Guarnizione in EPDM + ceramic ball valve configuration
Precauzione: Isolate power before service. Wear protection for corrosive chemicals; ensure ventilation for hypochlorite, acid and alkali media.
- Colpa: Pump runs, no suction / no chemical output
| Sintomo | Possibile causa | Controllo & Rimedio |
| Stepper motor runs normally, stroke action visible, no discharge | Air trapped inside pump head, insufficient priming | 1. Open manual air vent valve on pump head;2. Keep suction hose fully submerged to drain air from piping;3. Cycle pump at low flow to purge bubbles; close vent after air removed |
| Air leakage on suction side (più frequente) | Inspect foot valve, hose ferrules, cracked tubing;Ageing / kinked PE tubing or loose fittings leak air;Submerge foot valve ≥10cm below liquid level; avoid suction pipe above tank liquid level | |
| Suction/discharge valve stuck, ball stuck or fouled | Dismantle valve assemblies, clean ceramic balls and EPDM seats;Dirt, scale or crystals prevent tight sealing;Inspect balls for chipping or cracking | |
| Foot valve clogged / foot valve check valve failed | Remove and clean foot valve strainer; replace foot valve if worn or jammed | |
| Diaphragm ruptured | Check vent port and pump housing for chemical leakage;Medium entering drive chamber means diaphragm failure; shut down and replace repair kit | |
| Altezza di aspirazione eccessiva | DDE has limited self-priming capability; flood suction side preferred (tank above pump); vertical suction lift ≤2m | |
| Medium viscosity out of range | Viscosity >50 mPa·s exceeds pump specification, poor priming |
- Colpa: Inaccurate flow, low/high actual output, flow drift
| Sintomo | Possibile causa | Controllo & Rimedio |
| Metered flow deviates from setpoint, persistently low flow | Air ingress or poor valve sealing (same as above leakage issues) | Perform air purge and suction side leak test first; this is the #1 cause of flow inaccuracy |
| Valve ball / seat wear, crystal buildup, poor sealing | Dismantle and clean valve assemblies; EPDM ages and swells under continuous high chlorine exposure – replace repair kit | |
| Diaphragm fatigue, reduced swept volume | Diaphragm creep after long runtime; replace full repair kit | |
| Unstable outlet backpressure, backpressure too low | Install backpressure valve on dosing pump outlet; free flow siphoning occurs without backpressure valve, causing uncontrolled flow;This pump rated 10 sbarra; continuous low-pressure siphoning leads to over-dosing | |
| Pulse control mode: wrong pulse scaling or faulty signal source | Verify pulse ratio and scaling parameters for external pulse control;Switch to local manual mode to isolate pump fault vs controller signal fault | |
| Changing chemical temperature or crystallisation | Temperature changes alter density; crystals accelerate valve wear and gradual flow decay | |
| Calibration lost | Re-calibrate by timed volumetric collection and re-set calibration on pump panel |
- Colpa: Rumore anomalo, vibrazione
| Sintomo | Possibile causa | Controllo & Rimedio | |
| Regular tapping / clicking sound with unstable discharge | Ball hammering seat (typical air-bound noise) | Purge air first; cavitation causes dry ball impact noise | |
| Cracked / chipped ceramic ball | Disassemble valve set; replace valve kit if ceramic ball damaged | ||
| Hum from motor, forti vibrazioni, intermittent output | Piping resonance, loose hose supports | Add pipe clamps; avoid rigid hard pipe tension pulling pump inlet/outlet | |
| Pump installed off-level, pump head under stress | Mount pump horizontally; prevent hose tension pulling pump head | ||
| Stepper motor overload, diaphragm jammed | DDE has no manual crank; energise and observe stroke movement;Jammed crystals or debris on diaphragm increase load | ||
| Intermittent high-pitched whistling | Over-restriction / dead-head pressure or cavitation | Check for blocked outlet piping or clogged injection valve; clean injection check valve |
- Other Common Faults
- Visualizzazione normale, no pumping action at all
Power supply fault / sottotensione; check 230V supply and loose terminals
Keypad lock active; unlock panel
- Leakage at pump head
Aged pump head O-rings, uneven bolt torque; tighten pump head bolts diagonally and evenly
Ruptured diaphragm with chemical leaking into drive side → stop immediately, replace repair kit
- Continuous dripping from air vent
Worn vent valve seal; replace vent valve component or full repair kit
Recommended Diagnostic Sequence
- Confirm power supply and control mode (locale / impulso)
- Vent air → inspect suction side for air leaks
- Volumetric flow test to confirm true pump fault or signal issue
- Dismantle and inspect valve assemblies, ceramic balls and EPDM seals
- Inspect diaphragm for rupture and leakage
- Check outlet backpressure valve and injection valve for blockage or failure
- Final action: replace complete pump head repair kit (97751105)
Sicurezza & Note sulla manutenzione
For crystallising media (PAC, phosphate, high brine), flush pump head and valves with clean water after shutdown to prevent seizure
EPDM seals are not suitable for long-term high-concentration sodium hypochlorite service; use V variant (FKM) for chlorine dosing
Tighten pump head bolts diagonally and evenly; uneven torque can crack PP pump head
Grundfos SMART Digital DDE Series List (S-series ≤15L/h Economy Range)
Important separation: S-series small flow DDE (6-10 /15-4) (the model above); separate XL large flow DDE (60/120/200 L/h). Spare parts are NOT interchangeable.
Control variants exclusive to DDE: B / P / PR
B: Basic|manual adjustment + pulse input (la tua unità: DDE 6-10 B)
P: B + external start/stop + low-level input
PR: P + uscita allarme relè (stroke signal, relè di guasto)
- S-series DDE (low flow 0–15 L/h, ampiamente utilizzato) Base Models
| Modello base | Max Flow | Max Pressure | Turn-down Ratio | Min Flow |
| DDE 6-10 | 6 L/h | 10 sbarra | 1000:01:00 | 0.006 L/h (6 mL/h) |
| DDE 15-4 | 15 L/h | 4 sbarra | 1000:01:00 | 0.015 L/h (15 mL/h) |
Formato del modello completo:
DDE Flow-Pressure Control Code-Pumphead/Seal/Ball-Valve Type-Voltage Region Code FG
Esempio: `DDE 6-10 B-PP/E/C-X-31I001FG`
Material Combinations (Pumphead / Foca / Ball)
PP/E/C: PP pump head + Guarnizione in EPDM + ceramic ball (your configuration, fresh water, weak acid/alkali)
PP/V/C: PP pump head + FKM seal + ceramic ball (sodium hypochlorite, chlorine media)
PVC/E/C: PVC pump head + Guarnizione in EPDM + ceramic ball
PVC/V/C: PVC pump head + FKM seal + ceramic ball
PVDF/T/C: PVDF pump head + PTFE seal + ceramic ball (strong acid / heavy corrosion)
PP/E/SS: PP + EPDM + stainless steel ball (special abrasion service)
Valve Type Codes
X: Standard double ball valve (non-spring-loaded, scopo generale)
H: Spring-loaded valve (unstable backpressure, high viscosity media)
Voltaggio / Region Codes (Comune)
31I001: 230V50Hz, RCM AU/NZ, 4/6mm hose compression (la tua unità)
31U2U2: 100–240V universal voltage, CE, EU specification
31V: 110V North America version
S-series Finished Model Examples (Direct for PO)
- DDE 6-10 B-PP/E/C-X-31I001FG (PN 97720906|your pump)
- DDE 6-10 B-PP/V/C-X-31I001FG (chlorine resistant same rating)
- DDE 6-10 PR-PP/V/C-X-31U2U2FG|alarm relay, universal voltage
- DDE 15-4 B-PP/E/C-X-31I001FG|15L/h 4bar, EPDM
- DDE 15-4 P-PVDF/T/C-X-31U2U2FG|PVDF heavy corrosion, controllo degli impulsi
- SMART Digital XL DDE (Large Flow 60~200 L/h, gamma indipendente)
XL pump head structure and repair kits are incompatible with S-series 6-10 /15-4
| DDE 60-10 | 60 L/h | 10 sbarra |
| DDE 120-7 | 120 L/h | 7 sbarra |
| DDE 200-4 | 200 L/h | 4 sbarra |
XL example:
DDE 60-10 B-PP/V/C-F-31U3U3FG
- DDE Control Variant Function Table
| Codice di controllo | Manual Adjustment | Pulse Input | External Stop / Basso livello | Relay Alarm Output |
| B | ✅ | ✅ | ❌ | ❌ |
| P | ✅ | ✅ | ✅ | ❌ |
| PR | ✅ | ✅ | ✅ | ✅ (2 relè) |
- Differenziazione in serie (Avoid mixing with DDC / DDA)
DDE: Economia, basic function, no 4-20mA analog input, conveniente (OEM water treatment standard)
DDC: Grado standard, 4-20analogico mA, extended menu, additional alarms
DDA: Premium grade, built-in FCM flow monitoring, alta precisione, batch dosing, complex interlock
- Spare Part Cross-reference Summary
S-series (6-10 /15-4): Repair kit family SD-S-1-xxx, PN 97751105 for PP/E/C
XL series (60/120/200): Dedicated XL repair kits, non intercambiabile
- Guida alla selezione rapida
- Sodium hypochlorite / chlorine dioxide dosing: prefer `/V/` (FKM), avoid EPDM `/E/`
- Acido concentrato / heavy corrosion: PVDF `/T/`
- Unstable backpressure or siphon risk: select H spring-loaded valve instead of X standard valve
- Standard domestic global supply: prefer 31U2U2 universal voltage; AU/NZ export use 31I001