W2: 2-axis integrated drive (one unit controls 2 motori)

77: Rated power of each axis: 750W + 750W

B: SSCNETⅢ/H fiber bus interface for fiber synchronous control, compatibile con Mitsubishi motion CPUs

📋 Main Specifications

ArticoloSpecifica
Number of axes2 assi
Rated power per axis0.75kW (750W)
Alimentazione elettrica3-fase / single-phase AC200~240V, 50/60Hz (marked on label: 3PH+1PH 200-240V)
Communication busSSCNETⅢ/H (high-speed fiber synchronization)
Funzione di sicurezzaBuilt-in STO Safe Torque Off (conforme alla CEI 61800-5-2)
Freno dinamicoIntegrato
DimensioniW85 × H168 × D195 mm
Peso2 kg
Supporto dell'encoder22-codificatore assoluto a bit (4,194,304 p/r)
CertificazioniCE, UL/cUL, UKCA, RoHS
Codice SA85044095

 

Mitsubishi MR-J4W2-77B 2-axis integrated servo drive

🛠️ Compatible Motors

Compatible with Mitsubishi HG-MR73 / HG-KR73 (750W J4-series servo motors), supporting absolute encoders.

🎯 Typical Applications

Attrezzatura sincrona multiasse: montatori di chip, inspection platforms, moduli di trasferimento, Macchine ausiliarie CNC, macchine per l'imballaggio, apparecchiature per semiconduttori.

Vantaggio: Two axes share one drive, saving cabinet space and reducing cost.

🔄 Replacement Options

  1. Upgrade to new generation (J5):MR-J5W2-77B (same 2-axis rating, SSCNETⅢ/H compatible, prestazioni migliorate)
  2. Separate drive solution:2 pcs MR-J4-70B (single-axis 750W, larger footprint)
  3. Legacy replacement:Predecessor MR-J3W-77B. Wiring and program differences, non plug-and-play

This is a bus-type servoazionamento; pulse command control is not supported directly. It must be used with Mitsubishi motion controllers (Q/R series motion CPU) via SSCNET fiber link.

USB port for commissioning; configured with MR Configurator2 software.

Pezzi di ricambio: Power board, CPU board, CNP connector with individual part numbers (303772, 303769, ecc.)

MR-J4W2 (MR-J4W2-77B) Allarme / Fault Code List

Descrizione: MR-J4W2 2-axis integrated type B (SSCNETⅢ/H). Alarms are divided into fault alarms (latched, reset required) and warnings (no shutdown, prompt only).

Suffisso .1/.2 stands for Axis 1 / Asse 2, which is critical for this 2-axis model.

Readout: Drive panel or MR Configurator2 software; alarm history can be saved with waveform data for troubleshooting.

  1. Fault Alarms (ALME, machine shutdown)
  1. Codice allarmeNomeBrief Cause & Risoluzione dei problemi
    10SottotensioneInsufficient DC bus voltage; missing phase, caduta di tensione, scarso contatto del contattore, damaged rectifier module
    12Memory errorInternal ROM / flash failure; replace drive if fault persists after power cycle
    13Clock errorInternal RTC failure; drive replacement is generally required
    15Power circuit errorPre-charge / soft-start circuit failure on main power side
    16Guasto a terraShort to earth of motor power cable, motor winding insulation breakdown
    19Main circuit errorIPM or power driver hardware damage
    1UNMotor combination errorMismatched motor model in PA01/PA02; wrong encoder cable or motor selection (.1 Axis1, .2 Axis2)
    20Encoder initial communication errorHandshake failure at power-up; broken encoder cable, connettore allentato, faulty encoder
    24Encoder communication errorCommunication dropout during operation; Interferenza EMI, poor shield on long cable, water ingress in connector
    25Encoder Z-phase errorAbnormal encoder zero signal
    2BEncoder counting errorCount disorder caused by interference or encoder hardware failure (.1 Axis1, .2 Axis2)
    30Regeneration errorBroken regenerative resistor, wrong resistance value, excessive regenerative power; built-in regeneration insufficient, external resistor required
    31Velocità eccessivaMotor speed exceeds limit; abnormal command, encoder feedback fault, runaway due to excessive gain
    32SovracorrenteHardware / software overcurrent; phase-to-phase short circuit in motor, shorted power wire, IPM breakdown, mechanical jam
    33SovratensioneDC bus over-limit; excessive energy feedback during deceleration, high input voltage, failed regeneration circuit
    34SSCNET receive error 1SSCNETⅢ/H fiber communication fault: bent fiber, contaminated end face, connettore allentato, faulty fiber port on motion CPU
    35Command frequency errorIllegal command sent from upper motion controller
    36SSCNET receive error 2Fiber synchronization timing error, multi-axis link synchronization fault
    37Parameter errorParameter out of range or checksum error; restore factory settings and re-download parameters
    3UNSurge suppression circuit errorSoft-start circuit failure at power-on
    3EOperation mode errorMismatch between control mode parameter and SSCNET configuration on master side
    42Full-closed control errorExternal linear scale feedback fault (only for full-closed loop mode)
    45Main device overheatPower module overheat; blocked cooling air duct, fan stall, temperatura ambiente elevata
    46Motor overheatMotor thermal sensor triggered; continuous overload, poor motor heat dissipation (.1 Axis1, .2 Axis2)
    47Cooling fan faultDrive internal fan stall / low speed; inceppamento di oggetti estranei, fan aging
    50Sovraccarico 1Sovraccarico continuo (electronic thermal protection); mechanical binding, high friction, undersized selection
    51Sovraccarico 2Peak overload; impact load, sudden mechanical lock
    52Position excessive errorPosition deviation exceeds threshold; lost pulses, mechanical jam, low gain, excessive command speed (.1 Axis1, .2 Axis2)
    54Vibration detectionServo oscillation; guadagno eccessivo, risonanza meccanica
    56Forced stop alarmSTO safety circuit open, emergency stop triggered, disconnected STO wiring
    61Operation errorIllegal command while servo ON, sequence control error
    63STO timing errorTiming mismatch between two STO channels, asymmetric safety wiring
    64Safety setting errorIncorrect STO safety parameter configuration

    Avvertenze (AVVISARE, servo keeps running, alert only)

Warning CodeNomeDescrizione
91Drive overheat pre-warningTemperature approaching protection threshold
92Battery cable breakAbsolute encoder battery wire disconnected; dead battery, spina allentata
95STO warningSingle STO channel abnormal (single wire open, shutdown alarm not triggered yet)
96Home setting warningFaulty home signal logic or home proximity signal
9BPosition deviation pre-warningPosition error close to alarm threshold
9FBattery low warningEncoder battery voltage low; replace battery soon to avoid home position loss
E0Regeneration overload warningSustained high regenerative load
E1Overload warning 1Load approaching overload threshold
E2Motor overheat warningMotor temperature rising
E3Absolute counter warningAbnormality of absolute position counter
E4Parameter warningUnreasonable parameter setting (no latch-up)
E6Drive-side forced stop warningSTO / E-stop triggered at drive side
E7Controller forced stop warningStop command issued by upper motion CPU
E8Fan speed drop warningFan aging with reduced speed, not stalled
E9Main circuit OFF warningMain power cut off while control power remains energized
EBOther axis alarm (2-axis specific)The other axis on this drive has an active fault
CEOverload warning 2High peak load detected
EDOutput power limit warningContinuous output power close to rated limit
F0Tough drive instantaneous power dip warningTough drive function activated by voltage fluctuation
F2Drive log write errorInternal fault recorder access failure
F3Vibration diagnostic warningHigh mechanical vibration detected by diagnostic function

Special Notes for MR-J4W2 2-Axis Drive

  1. Suffisso .1 = CH1 (Asse 1);.2 = CH2 (Asse 2). Confirm faulty axis first; motor and encoder of the two axes are independent.
  2. EB warning is unique to this multi-axis model: When one axis faults, the other axis reports EB to indicate the companion axis failure. Do not troubleshoot EB directly; check the real alarm code on the other channel.
  3. 34 / 36 fiber alarms: For SSCNETⅢ/H fiber, clean end face first, minimum bend radius ≥30mm, avoid sharp bends.
  4. STO (56, 63, 95): Two STO channels must switch synchronously; inconsistent timing triggers code 63.
  5. Reset allarme: Remove root cause first, turn servo SON OFF then reset. Some hardware faults cannot be cleared by power cycling.

Mitsubishi MELSERVO Servo Drive Model List

General suffix definition

UN: Impulso + interfaccia analogica (pulse command type)

B: SSCNETⅢ/H fiber bus (fiber synchronization with motion CPU, MR-J4W2-77B belongs to this type)

GF / G: CC-Link IE / CC-Link IE TSN Ethernet bus

W2: 2-axis integrated; W3: 3-axis integrated

D1/D2/D3: Separate power type (amplifier unit paired with MR-CV power supply)

Numeric code for power rating (10=0,1kW, 20=0,2kW, 40=0,4kW, 60=0.6kW, 70=0,75kW, 100=1kW, 200=2kW, 350=3.5kW, 500=5kW, 700=7kW)

RJ: Special specification version

Active Series (Available for new orders)

  1. Serie MR-J5 (Ultima generazione, MELSERVO-J5, 3.5risposta kHz)

Asse singolo

MR-J5-10A / 20UN / 40UN / 60UN / 70UN / 100UN / 200UN / 350UN / 500UN / 700A 【Pulse type】

MR-J5-10G / 20G / 40G / 70G / 100G / 200G / 350G / 500G / 700G 【CC-Link IE TSN】

MR-J5-10B / 20B / 40B / 70B / 100B / 200B / 350B 【SSCNETⅢ/H fiber】

Multi-axis integrated

MR-J5W2-22B / 44B / 77B / 1010B / 2020B (2-asse, SSCNET fiber)

MR-J5W3-222B / 444B / 777B (3-asse, SSCNET fiber)

MR-J5W2-22G / 44G / 77G / 1010G (2-asse, CC-Link IE TSN)

MR-J5W3-222G / 444G / 777G (3-asse, CC-Link IE TSN)

Separate power type (Common DC bus regeneration system)

MR-J5D1-G4-N1 (1-asse), MR-J5D2-G4-N1 (2-asse), MR-J5D3-G4-N1 (3-asse)

Matching power unit: MR-CV4 regenerative converter

  1. Serie MR-J4 (Mature mainstream, your model belongs here)

Asse singolo

MR-J4-10A / 20UN / 40UN / 60UN / 70UN / 100UN / 200UN / 350UN / 500UN / 700UN / 11IL / 15IL / 22IL

MR-J4-10B / 20B / 40B / 60B / 70B / 100B / 200B / 350B / 500B / 700B (SSCNETⅢ/H)

MR-J4-10GF / 20GF / 40GF / 70GF / 100GF (CC-Link IE Field)

Multi-axis integrated (Focus: MR-J4W2 / J4W3)

MR-J4W2-22B (0.2+0.2kW)

MR-J4W2-44B (0.4+0.4kW)

MR-J4W2-77B (0.75+0.75kW, il tuo modello)

MR-J4W2-1010B (1+1kW)

MR-J4W2-2020B (2+2kW)

MR-J4W3-222B / 444B / 777B (3-axis integrated)

MR-J4W2-0303B6 (Low-power special version)

Separate amplifier unit

MR-J4-DU900B / DU11KB / DU15KB / DU22KB, used with MR-CV regenerative power supply

  1. MR-JE Economy Series (Low-cost, impulso / simple bus, low power range)

MR-JE-10A / 20UN / 40UN / 70UN / 100UN / 200UN

MR-JE-10C / 20C / 40C / 70C (EtherCAT version, JE-C)

Applicazione: Simple feeding and transfer; SSCNET fiber multi-axis synchronization is not supported

  1. MR-JN Micro Economy Series (Ultra compact, 10~100W)

MR-JN-10A / 20UN / 40UN / 60UN / 100UN

Applicazione: Small rotary tables, miniature slides, entry-level low-power

⏸️ Obsolete Series (Spare parts market only, not recommended for new machines)

MR-J3 (Production discontinued, stock spares reducing)

Asse singolo: MR-J3-10A /20A/40A/70A/100A/200A/350A / MR-J3-10B/20B/40B/70B

Multi-axis: MR-J3W-22B / MR-J3W-44B / MR-J3W-77B (J3 2-axis, predecessor of J4W2)

CC-Link version: MR-J3-10T / 20T /40T

MR-J2S (Eredità, manufacturer repair service terminated)

MR-J2S-10A/20A/40A/70A/100A/200A/350A, MR-J2S-10B, MR-J2S-CP (built-in positioning type)

MR-J2 (Erly first generation, nearly phased out)

MR-J2-10A、MR-J2-20A, ecc.

📌 Auxiliary Units (Common servo system accessories)

MR-CV: Regenerative power converter (common DC bus system for J4/J5D)

MR-RB: External regenerative braking resistor

MR-TB: Terminal block adapter

📎 Quick Selection Reference for MR-J4W2-77B

Sostituzione della stessa serie: MR-J4W2-77B

Upgrade to new generation: MR-J5W2-77B (SSCNET compatible, preferred direct upgrade)

Separate drive alternative: 2 pcs MR-J4-70B

Alternativa economica: JE series does not support SSCNET fiber, cannot replace directly