ABB MS116-4.0MPCB - Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari

Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Di Contatto |

ABB MS116-4.0MPCB - Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari

interruttore automatico/

ABB MS116-4.0MPCB

ABB MS116-4.0 Technical Datasheet (Manual Motor Starter / Interruttore automatico di protezione del motore) Key Overview: 3-palo, rated current 4.0A (adjustable 2.5~4.0A), Class 10A tripping, 50kA/400V breaking capacity, suitable for 1.5kW/400V AC-3 motors, 45mm DIN-rail mounting, Protezione IP20, global order number 1SAM250000R1008. Model Explanation Model Part Description MS116 ABB MS116 series compact 3-pole manual motor starter, integrated ...

  • Dettagli del prodotto

ABB MS116-4.0 Technical Datasheet (Manual Motor Starter / Interruttore automatico di protezione del motore)

Key Overview: 3-palo, rated current 4.0A (adjustable 2.5~4.0A), Class 10A tripping, 50kA/400V breaking capacity, suitable for 1.5kW/400V AC-3 motors, 45mm DIN-rail mounting, Protezione IP20, global order number 1SAM250000R1008.

  1. Spiegazione del modello
Parte del modelloDescrizione
MS116ABB MS116 series compact 3-pole manual motor starter, integrated thermal-magnetic protection (sovraccarico + cortocircuito + mancanza di fase), fuse-free design
4Rated operational current Ie = 4.0A, adjustable range 2.5~4.0A
1SAM250000R1008Global order code
Dimensioni / MontaggioLarghezza 45 mm, standard 35mm DIN rail mounting, IP20 degree of protection
  1. Core Electrical & Mechanical Data

2.1 Di base & Protection Parameters

ParametroValoreDescrizione
Numero di poli3-paloFor three-phase motor protection
Rated current Ie4.0UNAdjustable range 2.5~4.0A
Tripping classClass 10ATypical motor tripping characteristic; trips in approx. 10 s at 10 overload current
Protezione da cortocircuito50UN (fisso)Instantaneous magnetic trip, no extra fuse required
Breaking capacity Ics50IL (400V e)Rated service short-circuit breaking capacity
Tensione nominale690V e, 50/60HzSuitable for various voltage systems
Applicable power (AC-3)1.5kW (400V) / 2 hp (480V)For standard motor duty
Funzioni di protezioneTemperature compensation, fuse-free protection, free tripping mechanism, funzione di isolamento, protezione dalla mancanza di faseComprehensive motor protection, IEC compliant

2.2 Meccanico & Mounting Data

  1. ParametroValore
    Larghezza45mm
    Altezza90mm
    Profondità85.6mm
    Peso0.225kg
    MontaggioGuida DIN standard da 35 mm (TH35-15/TH35-7.5)
    ConnessioneMorsetti a vite, main circuit torque 0.8~1.2Nm
    OperationManiglia rotante (clear ON/OFF indication), free tripping mechanism
    Grado di protezioneIP20 (anteriore)
    Consumo energetico5.4W
    Temperatura ambiente-25C≈+55C

    Guida alla selezione

3.1 Applicazioni tipiche

Direct starting and protection of small three-phase motors (1.5kW/400V)

Control of pumps, tifosi, compressors and industrial automation equipment

Replacement of traditional “fuse + contactor” combinations to save space and cost

Applications requiring manual control and reliable motor protection

3.2 Selection Steps

  1. Verify motor rated current: within 2.5~4.0A adjustable range
  2. Check motor power: ≤ 1.5kW (400V AC-3)
  3. Confirm system voltage: ≤ 690V AC, 50/60Hz
  4. Evaluate short-circuit current: system short-circuit current ≤ 50kA (400V)
  5. Installation space: reserve 45mm DIN rail width
  6. Ambient conditions: temperature -25°C ~ +55°C, no excessive vibration or corrosive gas

3.3 Setting & Note operative

Protezione da sovraccarico: set to 1.0~1.1 × motor rated current (within 2.5~4.0A)

Ensure reliable phase failure protection for all three-phase motor applications

Use isolation function: safe electrical isolation after shutdown for maintenance

Can be used with contactors for remote control and automatic protection

  1. Cross-Brand Replacement Models
MarcaModelloParametri principaliDifferenze
SchneiderGV2ME083-palo, 2.5~4.0A, Classe 10, 50kA/400VStessa larghezza (45mm), functionally compatible, sostituzione diretta
Siemens3RV2011-0JA103-palo, 2.5~4.0A, Classe 10, 50kA/400VMatching mounting dimensions, compatible protection characteristics
EatonPKZM0-43-palo, 2.5~4.0A, Classe 10, 50kA/400VFunctionally and dimensionally compatible, conveniente
ABB UpgradeMS132-4.03-palo, 2.5~4.0A, Classe 10, 100kA/400VMaggiore potere di interruzione, backward compatible mounting
  1. Note applicative
  2. Thermal-magnetic characteristics: Class 10A is intended for standard squirrel-cage motors; not recommended for special loads (per esempio., trasformatori, capacitors)
  3. Phase failure protection: Trips within 2~5 seconds if any phase is lost, effectively preventing motor burnout
  4. Fuse-free design: Eliminates external fuses, reduces cost and maintenance; ensure line short-circuit current ≤ 50kA
  5. Free tripping mechanism: Forces tripping under overload/short-circuit even in ON position, ensuring safety
  6. Temperature compensation: Protection characteristics stable over ambient temperature range -25°C ~ +55°C

Prec:

Prossimo:

Lascia una risposta

Lasciate un messaggio