This is an ABB SACE Tmax T6N 800A MCCB equipped with a TMA800/4000-8000 adjustable thermomagnetic release, 3-palo, fixed mount, collegamento frontale, with N-type breaking capacity (36kA@400V). It is used as a main switch in industrial main circuits, heavy-duty motor protection, and power distribution systems. Full Model Code Breakdown Section Marking Description Technical Note 1 T6 ...

  • Dettagli del prodotto

This is an ABB SACE Tmax T6N 800A MCCB equipped with a TMA800/4000-8000 adjustable thermomagnetic release, 3-palo, fixed mount, collegamento frontale, with N-type breaking capacity (36kA@400V). It is used as a main switch in industrial main circuits, heavy-duty motor protection, and power distribution systems.

  1. Full Model Code Breakdown
SectionMarkingDescrizioneTechnical Note
1T6Frame sizeTmax T series MCCB, max frame current 800A, compact design (depth 103.5mm)
2NBreaking capacity classN‑type standard breaking capacity: 36kA@400V/415V, 25kA@500V, 20kA@600V
3800Frame rated currentMaximum rated current of the interruttore automatico telaio: 800UN
4TM/TMARelease typeThermomagnetic Adjustable release – both overload (thermal) and short‑circuit (magnetic) protection are adjustable
5800Corrente nominale (In)Continuous operating current: 800UN
640000‑8000Instantaneous trip rangeI3 = 4000–8000A, adjustable short‑circuit instantaneous protection
7FMounting typeFisso (non‑withdrawable)
8FConnection typeCollegamento frontale
93PPoles3‑pole circuit breaker for three‑phase systems
  1. Parametri tecnici chiave
ItemValoreRemarks
Product typeSACE Tmax T6N 800A MCCBFactory code: 1SDA060214R1
Tensione di isolamento nominale (Ui)1000VMaximum continuous voltage for insulation parts
Rated impulse withstand voltage (Uimp)8kVCapability to withstand transient high voltage
Rated operating voltage (Ue)690V eMax operating voltage
Frequenza50/60HzFor standard mains systems
Trip characteristicAdjustable thermomagneticSovraccarico (inverse time), short‑circuit (instantaneous)
Ultimate breaking capacity (Icu)36kA@400VN class
25kA@500V
20kA@600V
Service breaking capacity (Ics)100% IcuReusable after tripping
Corrente nominale (In)800UNMaximum continuous current
Instantaneous trip range4000–8000AI3 = 5–10In, adjustable
Dimensioni (mm)H×W×D: 268×210×103.5Uniform depth for panel layout
Pesoapprox. 9kgStandard
Protection degreeIP30CEI 60529
  1. Applicazioni tipiche
  2. Industrial power distribution

Main or sub-switch for 3-phase 800A circuits in factories, workshops, data centers.

  1. Large motor protection

Three-phase induction motors up to approx. 400kW (380V)

Critical motor circuits requiring adjustable overload and short-circuit protection

  1. Building electrical

Main switchboards in commercial and high-rise buildings

Power circuits for HVAC, pumps, and large equipment

  1. Renewable energy

Main switches in combiner boxes for PV and wind power systems

DC-side protection for energy storage (DC version required)

  1. Other heavy industries

Mining, ports, railways, and applications requiring high reliability and adjustable protection.

  1. Replacement Models

4.1 ABB Upgrades / Replacements

Modello sostitutivoMain DifferenceApplication
T6S800 TMA800/4000‑8000 FF 3PBreaking capacity upgraded to S class (50kA@400V)Systems with higher short‑circuit current near transformers
T6L800 TMA800/4000‑8000 FF 3PBreaking capacity upgraded to L class (70kA@400V)Heavy industrial grids and large plants
T6N800 PR221DS‑LSI 800 FF 3PElectronic LSI release (Long / Short / Instantaneous)Complex systems requiring precise grading and selectivity
XT6N800 TMA800/4000‑8000 FF 3PNew‑generation Tmax XT, same dimensions, improved performanceSystem upgrades and new installations

4.2 Cross-Brand Equivalents

MarcaModelloKey Matching ParametersNote
SchneiderNSX630N TM800D 3PIn=800A, Icu=36kA, thermomagneticNSX max frame 630A; 800A is special rating
Siemens3VA6880‑6EL32‑0AA0In=800A, Icu=36kA, 3P, thermomagnetic3VA series, similar performance
MitsubishiNF800‑CW 3PIn=800A, Icu=35kA, thermomagneticJapanese standard, suitable for Japanese equipment
DeltaPM800H‑3PIn=800A, Icu=36kA, thermomagneticCost‑effective industrial MCCB
  1. Selection & Application Notes
  2. Breaking capacity matching

Ensure short-circuit current ≤ 36kA@400V; otherwise use T6S/T6L.

Icu is only 20kA at 600V – use with caution.

  1. Release settings

Sovraccarico (thermal): set to 1.0–1.1 × load rated current

Instantaneous (magnetic): set to 5–10 × In to avoid nuisance tripping while maintaining selectivity.

  1. Mounting & wiring

Fisso, collegamento frontale; allow depth ≥ 103.5mm.

Use copper busbar/cable rated for 800A; ≥240mm² copper recommended.

  1. Maintenance & replacement

Regularly verify release settings.

Inspect contacts after short-circuit tripping; replace if needed.

For upgrades, prefer T6S/T6L or XT6N to keep dimensions compatible.

  1. Conclusione

ABB T6N800-TM800-40000-8000-F-F-3P is a high-performance 800A MCCB with compact size, adjustable thermomagnetic protection, and standard breaking capacity. It is ideal for high-current three-phase circuits in industrial automation. Selection should consider system short-circuit current, protection requirements, and installation space. For better accuracy and selectivity, use higher-breaking versions or electronic releases.

Schneider Replacement for ABB T6N800-TM800-40000-8000-F-F-3P

Key Summary: The ABB T6N800 is an MCCB; Schneider’s NSX series is the best match. If you require an MT air circuit breaker (ACB), suitable models are also available. Full solutions and technical comparisons below.

  1. Product Type Comparison
TipoABBSchneider Corresponding SeriesMain Difference
MCCBT6N800NSX SeriesCompatto, 36–150kA, for sub‑circuits
ACBNo equivalent in Tmax T6MT SeriesLarger, 50–200kA, for main incomers
  1. Schneider MT ACB Replacement

2.1 Recmmended Model: MT08N1 3P F MIC2.0+LR 800A

Model explanation:

MT08: Frame size 800A

N1: Breaking capacity 50kA@400V (higher than T6N 36kA)

3P: 3-palo

F: Fixed mount

MIC2.0+LR: Thermomagnetic protection (Long + Instantaneous)

800UN: Corrente nominale

Parameter matching:

ItemABB T6N800Schneider MT08N1Match Level
Corrente nominale (In)800UN800UNPerfect
MountingFissoFissoPerfect
Poles3P3PPerfect
Potere di interruzione (Icu)36kA@400V50kA@400VHigher
Release typeThermomagnetic (TMA)Thermomagnetic (LR)Functional match
Instantaneous range4000–8000A (5–10In)5–10In adjustablePerfect

Order No: 63006 (MT08N1 3P F MIC2.0 800A)

2.2 Alternatives (Higher Breaking)

MT08N2 3P F MIC2.0+LR 800A: 50kA@400V, wider current range

MT08H1 3P F MIC2.0+LR 800A: 65kA@400V for heavy short-circuit systems

  1. Better Schneider NSX MCCB Replacement

3.1 Recommended Model: NSX800F TMD 800 3P3D F

Model explanation:

NSX800: Frame 800A

F: 36kA@400V (identical to T6N)

TMD: Thermomagnetic release (distribution type)

800: Rated current 800A

3P3D: 3-palo

F: Fisso, collegamento frontale

Parameter matching:

ItemABB T6N800Schneider NSX800FMatch Level
TipoMCCBMCCBPerfect
In800UN800UNPerfect
Icu36kA@400V36kA@400VPerfect
MountingFissoFissoPerfect
ConnectionFrontFrontPerfect
Poles3P3PPerfect
ReleaseTMATMDPerfect
Instantaneous5–10In5–10InPerfect

Order No: C80F3TM800

3.2 Higher-Breaking Alternatives

NSX800N TMD 800 3P3D F: 50kA@400V, order No C80N3TM800

NSX800H TMD 800 3P3D F: 70kA@400V for heavy industry

  1. Replacement Selection Notes
  2. Product type choice

For direct replacement of an MCCB, choose NSX for identical form factor.

For upgrading to a main incomer, use MT ACB (note larger dimensions).

  1. Release settings

Long-delay (Ir): 1.0–1.1 × rated current

Instantaneous (Ii): 5–10 × In (4000–8000A) to match original ABB behavior.

  1. Potere di interruzione

MT08N1, NSX800N/H exceed 36kA for improved safety.

NSX800F is sufficient if Isc ≤ 36kA.

  1. Mounting space

MT ACB depth ~300mm (much larger than T6N 103.5mm)

NSX matches T6 dimensions for easy retrofit.

  1. Riepilogo

Top Recommendation: Schneider NSX800F TMD 800 3P3D F (order No C80F3TM800).

Perfectly matches the ABB T6N800 in type, attuale, mounting, potere di interruzione, and characteristics, with near-identical dimensions for easy replacement.

Alternative: If ACB is required, use MT08N1 3P F MIC2.0+LR 800A (order No 63006), which provides higher breaking capacity but requires more space.

Let me know if you want a simplified 1-page English datasheet version for customers or bidding.