MCCB CHINT NM1LE-250S-4300-200A

MarcaModello sostitutivo
SchneiderEZD250E4200ELN (integrated leakage)
SchneiderNSX250N 4P 200A TM200D + Vigi NSX 250
ABBA2C250 TMF200/2000 4P integrated leakage
ABBTmax T2N250 TMD200/2000 4P + RC221
Siemens3VM1250-4ED32-0AA0
MitsubishiNV250-SV 4P 200A
DELIXICDM1LE-250/4300 200A
DELIXICDM3LS-250S/4300A 200A
GIUSTOTGM1LE-250/4300 200A
Interruttore ChangshuCM1L-250/4300 200A
NADERNDM1L-250/4300 200A
HUYUHUM1LE-250/4300 200A

  • Dettagli del prodotto

NM1LE-250S-4300-200A is a moulded case residual current circuit breaker (RCCB/MCCB with earth leakage protection) from CHINT (NM1LE Series).

  1. Full Model Explanation

NM1LE: Series code

N: CHNT company code

M: Moulded case circuit breaker

1: Design sequence

IL: With earth leakage / residual current protection

250: Frame rating current 250A (maximum frame current for this series)

S: Classe del potere di interruzione (Tipo standard, ultimate breaking capacity Icu=30kA)

4300: Poli & funzioni

4: 4 poli (3P+N)

3: Thermal-magnetic trip with overload + protezione da cortocircuito

00: No accessory trips (no undervoltage, no shunt trip)

200UN: Rated operational current In=200A (continuous permissible current)

  1. Parametri tecnici chiave (NM1LE-250S/4300 200A)
ArticoloValore
Tensione operativa nominale UeAC 400V/415V (3-phase 4-wire)
Tensione nominale di isolamento Ui800V
Rated impulse withstand voltage Uimp8kV
Frequenza nominale50Hz
Ultimate breaking capacity Icu30IL (Type S standard)
Service breaking capacity Ics15IL
Trip characteristicMagnetotermico (distribution type)
Rated residual operating current IΔn50mA / 100mA / 200mA (3 adjustable steps)
Residual operating timeStandard type ≤ 0.1s (time‑delay optional)
Numero di poli4P (Pole N type A: no overcurrent trip, always closed)
MontaggioTipo fisso (front connection mainly)
Norme applicabiliGB/T 14048.2, CEI 60947-2
  1. Funzioni principali
  2. Protezione da sovraccarico: Thermal trip delays and trips when current exceeds 200A.
  3. Protezione da cortocircuito: Magnetic trip operates instantly within 30kA short-circuit current.
  4. Residual current (earth leakage) protezione: Detects current imbalance between phase and neutral; trips quickly at set values (50/100/200mA) to prevent electric shock and electrical fires.
  5. Infrequent switching: Can be used as a main switch for circuits and equipment.
  6. Applicazioni tipiche

3-phase 4-wire distribution systems, industrial equipment, distribuzione dell’energia nell’edificio, construction temporary power, main circuits in shopping malls and factories, and other occasions requiring earth leakage + sovraccarico + short-circuit triple protection.

Complete Technical Data Sheet

CHINT NM1LE-250S/4300 200A

All parameters are from CHINT official catalog and manual, applicable to NM1LE-250S/4300 200A (4-pole moulded case residual current circuit breaker).

  1. Basic Identification Parameters
ArticoloKey ValueNote
Full product nameMoulded case residual current circuit breaker (interruttore differenziale)Distribution protection type
Brand/SeriesCINT / NM1LE SeriesUpgraded first generation
Full modelNM1LE-250S/4300 200AStandard front connection, no accessory trips
Frame rating current250UNMax rated current supported by this frame
Rated operational current In200UNLong‑term permissible operating current
Poli4 poli (3P+N)Pole N has no overcurrent trip, always closed
Classe del potere di interruzioneType S (Standard)Tipo H (rottura elevata) available for same frame
Tipo di viaggioThermal-magnetic tripLong‑time delay overload + instantaneous short‑circuit protection
ConformitàGB/T 14048.2, CEI 60947-2Certificato CCC
  1. Main Circuit Electrical Parameters
ArticoloKey ValueNote
Tensione operativa nominale UeAC 400V/415VFor 3-phase 4-wire systems
Tensione nominale di isolamento Ui800VMaximum insulation withstand voltage
Rated impulse withstand voltage Uimp8kVSurge & lightning overvoltage capability
Frequenza nominale50HzFor domestic mains power systems
Rated ultimate short-circuit breaking capacity Icu (AC400V)30ILMax safe breaking short-circuit current
Rated service short-circuit breaking capacity Ics (AC400V)15ILCan continue normal operation after breaking
Arc distance≤100mmMax arc flash during short-circuit breaking
ConnessioneCollegamento frontale (standard)Collegamento posteriore & plug-in type optional
Main terminal torque12N·mFor M8×16 terminal screws
Recommended copper conductor≥70mm² (solid) / 120mm² (stranded)Copper busbar / cable recommended
  1. Caratteristiche di protezione
ArticoloKey ValueNote
Protezione da sovraccarico (thermal trip)Non-tripping at 7.2In; trips within 1h at 1.3InReference temp +30°C, inverse time delay
Protezione da cortocircuito (magnetic trip)Instantaneous setting 12In (2400UN)Distribution type, reliable at 120% collocamento
Funzioni di protezioneSovraccarico, cortocircuito, corrente residua (earth leakage)Can be used for infrequent circuit switching
Inlet/outletTop inlet, bottom outlet (standard)Reverse connection strictly prohibited
  1. Earth Leakage Protection Parameters
ArticoloKey ValueNote
Rated residual operating current IΔn50mA / 100mA / 200mA, 3 adjustable stepsDIP switch on device
Rated residual non-operating current IΔn00.5×IΔnThreshold to avoid nuisance tripping
Residual operating time (standard)≤0,1 s (fast type)Trips within 100ms on earth fault
Earth leakage typeTipo CAReliable for sinusoidal AC residual current
Test circuitBuilt-in test circuitWith test button; test at least monthly
Earth fault indicationRed mechanical indicatorPops out after earth leakage trip
  1. Environmental & Parametri meccanici
ArticoloKey ValueNote
Operating ambient temperature-5℃ ~ +40 ℃Derate required beyond this range
Temperatura di conservazione-25℃ ~ +70 ℃Non-energized storage
Altitudine≤2000mDerate for higher altitude
Grado di inquinamento3Suitable for industrial distribution
Categoria di installazioneIIIFor distribution circuits and main equipment circuits
Ingress protectionIP30 (except terminals)Solid foreign object protection, not waterproof
Resistenza meccanica10,000 operazioniNo-load operating cycles
Electrical endurance4,000 operazioniAl carico nominale
Orientamento di montaggioVertical or horizontal mounting allowedInverted mounting not permitted
  1. Dimensioni (4-palo, unit: mm)
DimensioneValoreNote
Width W188Total width of 4-pole unit
Height L165Including terminals
Depth H102Body thickness
Horizontal mounting hole spacing140Center-to-center left-right
Vertical mounting hole spacing126Center-to-center up-down
Mounting hole diameter Ød4.5For M4 mounting screws
Minimum clearance≥25mm side, ≥5 mm superiore/inferioreFor side-by-side installation

Alternative Models from Other Brands

All below match the core specification:

4 poli (3P+N), 250Una cornice, 200Una corrente nominale, Icu ≥30kA at AC400V, thermal-magnetic overload + protezione da cortocircuito, AC-type earth leakage (50/100/200mA regolabile), no accessory trips, front fixed connection.

  1. Domestic High-Compatible Alternatives

(Dimensioni, prezzo, function highly matched; ideal for direct replacement)

  1. MarcaModello sostitutivoParametri di corrispondenza chiaveDescrizione
    DELIXICDM1LE-250/4300 200AIcu=30kA, 4P 200A, 50/100/200mA regolabile, thermal-magnetic1:1 design with NM1LE, high compatibility, no cabinet modification
    DELIXICDM3LS-250S/4300A 200AIcu=35kA, 4P 200A, adjustable leakage, thermal-magneticNew upgraded series, prestazioni più elevate
    GIUSTOTGM1LE-250/4300 200AIcu=30kA, 4P 200A, 50/100/200mA regolabileDirectly compatible with NM1LE
    Interruttore ChangshuCM1L-250/4300 200AIcu=35kA, 4P 200A, adjustable leakageIndustrial rade high reliability
    NADERNDM1L-250/4300 200AIcu=35kA, 4P 200A, adjustable leakageStable for construction & industry
    HUYUHUM1LE-250/4300 200AIcu=30kA, 4P 200A, 3-step leakageCost-effective direct replacement

    Joint-venture / International Brands

(Higher performance for premium projects & severe conditions)

MarcaModello sostitutivoParametri di corrispondenza chiaveDescrizione
SchneiderEZD250E4200ELN (integrated leakage)Icu=36kA, 4P 200A, 30/100/300mA regolabileEconomic universal type
SchneiderNSX250N 4P 200A TM200D + Vigi NSX 250Icu=50kA, 4P 200A, multi‑range leakageHigh‑end industrial grade
ABBA2C250 TMF200/2000 4P integrated leakageIcu=36kA, 4P 200A, adjustable leakageEconomic building distribution
ABBTmax T2N250 TMD200/2000 4P + RC221Icu=36kA, 4P 200A, multi‑range leakageHeavy industrial & foreign projects
Siemens3VM1250-4ED32-0AA0Icu=36kA, 4P 200A, 30/100/300mA regolabileStandard international type
MitsubishiNV250-SV 4P 200AIcu=36kA, 4P 200A, 100/200/500mA regolabileHigh reliability for precision equipment
  1. Key Replacement Notes
  2. Mounting dimension check: Domestic models (CDM1LE, TGM1LE, ecc.) are highly compatible with NM1LE for direct replacement. International brands often differ in size and hole spacing.
  3. Minimum breaking capacity: Icu at AC400V must be ≥30kA to ensure safety.
  4. Leakage matching: Prefer 50/100/200mA adjustable; use fast‑acting type ≤0.1s, not time‑delay.
  5. Poli & N-pole characteristic: Must be 4P (3P+N), with N-pole without overcurrent trip, always closed.
  6. Conformità: All replacements must be CCC certified and comply with GB/T 14048.2 / CEI 60947-2.