PowerFlex 755 Air-Cooled AC Azionamento a frequenza variabile (VFD)
Ciclo vitale: Obsoleto (Last order date: 2024‑06‑30). Direct OEM replacement part number: 20G11NC011JA0NNNNN
- Catalog Number Breakdown (20G Series Coding Rule)
20G 1 1 N C 011 UN 0 NNNNN
| Segmento | Codice | Descrizione |
| 1~3 | 20G | PowerFlex 755 air-cooled AC drive series |
| 4 | 1 | Embedded EtherNet/IP, protezione standard, raffreddamento ad aria forzata |
| 5 | 1 | AC input with DC bus terminals |
| 6 | N | IP20 / IP00, Open Frame (NEMA Open Type) |
| 7 | C | 400V trifase (380~480 VCA) |
| 8~10 | 11 | Rated output current 11.5A |
| 11 | UN | Integrated Dynamic Braking Transistor (DB Transistor) |
| 12 | 0 | No HIM keypad (blank) |
| 13~17 | NNNNN | No additional option modules |
- Specifiche elettriche principali
Corrente nominale: 11.5UN
Classe di tensione: 3-phase 400V AC
Potenza nominale:
ND (Dovere normale): 5.5kW
HD (Servizio pesante): 4kW
Dimensioni del telaio: Telaio 2
Raffreddamento: Raffreddamento ad aria forzata
Comunicazione: Embedded EtherNet/IP (DLR ring support)
Dynamic Braking: Built-in DB transistor, è necessaria una resistenza di frenatura esterna
Valutazione della custodia: IP20 (solo per montaggio in armadio)
Ingresso: AC main circuit with brought-out DC bus terminals, suitable for common DC bus applications
- Applicazioni tipiche
Trasportatori, tifosi, pompe, extruders and general-purpose industrial motor speed control; supports multi-axis EtherNet/IP motion control and can share the same network with Kinetix servo drives.
- Hardware & Note sulla manutenzione
- Obsolete notice: After discontinuation of AA0 suffix legacy units, JA0 is the drop-in compatible replacement. Dimensioni di montaggio, I/O and program parameters are fully compatible for direct replacement.
- Accessori opzionali: HIM keypad (20‑750‑HIM), input EMC filter, dynamic braking resistor, Coppia di sicurezza disattivata (STO) modulo.
- Common failure points: Fan aging, DC bus capacitor degradation, ESD damage on EtherNet/IP port; for spare part replacement, prioritize OEM JA0 version.
- Domestic Alternative Reference (Same rating 400V /11.5A VFD)
Inovance MD880, V&T AC800, Xinje DS500. Hardware replacement is feasible, but communication program, parameter groups and terminal definitions require re-commissioning. Cannot directly inherit the original Rockwell EtherNet/IP motion link.
- HS Code Reference
8504409990 (Other static converters, general classification for VFDs. Final customs classification subject to local customs authority.)
PowerFlex755 (20G11NC011AA0NNNNN) Power-On Commissioning Parameter List
Applicabile: 400V, ND 5.5kW / HD 4kW, embedded EtherNet/IP, integrated braking transistor. Struttura: Pre-power-on inspection → Factory reset → Motor nameplate data → Control mode → Start / Speed reference source → Accel/Decel & limiti & protection → Autotune → EtherNet/IP communication → Dynamic braking & fault strategy → Monitoring parameters
Nota: Parameter numbers refer to Port0 (drive native parameters). Actual values from motor nameplate must be entered on site. Italic values below are examples.
- Pre-Power-On Hardware Check (Not parameters, mandatory before commissioning)
- Circuito principale: 3-phase input R/S/T, output U/V/W, DC bus, braking resistor wiring and earthing.
- Circuito di controllo: 24V control supply, STO safety terminals must be shorted (short required if no STO module, otherwise safety fault alarm).
- Motor decoupling recommended: Disconnect mechanical load before initial autotune.
- Rating verification: Drive rated 11.5A, match motor rated current.
- Factory Reset (Nuovo progetto / After repair)
| Parametro n. | Nome inglese | Nome cinese | Collocamento | Osservazioni |
| 5 | Reset To Default | 恢复出厂 | Opzioni>Factory Reset | Takes effect after power cycle; clears all custom parameters. Recommended for new commissioning. |
- Motor Nameplate Parameters (Critico, enter from nameplate)
| Parametro n. | Nome inglese | Nome cinese | Example Value | Osservazioni |
| 26 | Motor NP FLA | 电机额定电流 | 10.5UN | Motor full load current from nameplate, shall not exceed drive 11.5A |
| 27 | Motor NP Hertz | 电机额定频率 | 50Hz | Dalla targa |
| 28 | Motor NP RPM | 电机额定转速 | 1480giri al minuto | Dalla targa |
| 29 | Mtr NP Pwr Units | 电机功率单位 | 0=kW /1=HP | 0=kilowatt |
| 30 | Motor NP Power | 电机额定功率 | 5.5kW | Dalla targa |
| 31 | Motor NP Volts | 电机额定电压 | 380V | Dalla targa |
- Modalità di controllo (TotalFORCE, for induction motors)
| Parametro n. | Nome inglese | Nome cinese | Impostazione consigliata | Osservazioni |
| 35 | Motor Cntl Mode | 电机控制模式 | 2=Sensorless Vector | Preferred for fans/pumps/conveyors; |
| use 3=Flux Vector for high precision torque control (encoder required) |
- Command Source & Speed Reference Source (Select ONE: Controllo del terminale / EtherNet/IP Network Control)
Opzione A: EtherNet/IP Network Control (Built-in port standard on this unit, most common for projects)
| Parametro n. | Nome inglese | Nome cinese | Collocamento | Osservazioni |
| 160 | Start Source | 启动命令源 | Port13 (Embedded EtherNet/IP) | Start/stop command from Logix controller |
| 161 | Speed Ref Source | 速度给定源 | Port13 (Embedded EtherNet/IP) | Speed reference from network |
Opzione B: Local Terminal Control (Commissioning test / Standalone test)
| Parametro n. | Nome inglese | Nome cinese | Collocamento | Osservazioni |
| 160 | Start Source | 启动命令源 | Ingresso digitale (DI Terminal) | Start/stop via DI terminals |
| 161 | Speed Ref Source | 速度给定源 | Ingresso analogico 0 (AI0) | AI analog 0-10V /4-20mA reference |
| 163 | DI Run | 数字输入 – 运行 | DI0 | DI0 = Run command |
| 164 | DI Stop | 数字输入 – 停止 | DI1 | DI1 = Stop (normally closed for safety) |
- Accel / Decel & Limit Parameters
| Parametro n. | Nome inglese | Nome cinese | Esempio | Osservazioni |
| 53 | Accel Time 1 | 加速时间 1 | 5.0S | Extend for heavy load; 8~20s for fans/pumps |
| 54 | Decel Time 1 | 减速时间 1 | 5.0S | Extend for high inertia loads; can shorten if braking resistor fitted |
| 55 | Max Freq | 最大频率 | 50Hz | Maximum operating frequency, do not exceed motor nameplate |
| 56 | Min Freq | 最小频率 | 0Hz | Minimum output frequency |
| 57 | Speed CLIP Hi | 最高转速限幅 | 1480giri al minuto | Matches motor rated speed |
- Attuale / Torque Protection Parameters
| Parametro n. | Nome inglese | Nome cinese | Esempio | Osservazioni |
| 42 | Motor OL Current | 电机过载保护电流 | Motor nameplate FLA | Motor thermal protection, use nameplate value |
| 44 | Motor OL Select | 电机过载保护模式 | 1=Class10 | Class10 for standard induction motors; Class20 for heavy duty |
| 47 | Current Limit 1 | 电流限幅 | 11.5UN | Drive rated output current |
| 49 | Torque Limit Pos | 正向转矩限幅 | 150% | Predefinito 150%; reduce for hoist applications |
| 50 | Torque Limit Neg | 反向转矩限幅 | 150% | Reverse torque limit |
- Motor Autotune (Critico! Run after entering nameplate data)
| Parametro n. | Nome inglese | Nome cinese | Operazione | Osservazioni |
| 70 | Autotune | 电机自整定 | Static Tune 2 | Motor decoupled from load before autotune. |
| Static Tune: No motor rotation. | ||||
| Rotational Tune: Motor spins, higher accuracy for commissioning |
After successful autotune, parameter 70 automatically returns to Ready 0. If autotune fails, controllare il cablaggio, nameplate entries and short-circuit to earth.
- Embedded EtherNet/IP Communication Parameters (Port13 Embedded Adapter)
| Parametro n. | Nome inglese | Nome cinese | Collocamento | Osservazioni |
| 36 | BOOTP | BOOTP 模式 | 0=BOOTP Disabled | For static IP addressing |
| 37 | IP Address | IP 地址 | 192.168.1.10 | Site planned IP address |
| 38 | Subnet Mask | 子网掩码 | 255.255.255.0 | Match subnet segment |
| 39 | Gateway | 网关 | 192.168.1.1 | Gateway address |
| 84 | Comm Flt Action | 通讯丢失动作 | 0=Fault (Fault Trip) | Network break protection; optional 1=Coast, 2=Hold Speed |
| 85 | Idle Flt Action | 控制器 Idle 动作 | 0=Fault | Drive action when PLC enters idle state |
Hardware DIP switch: All DIPs set to 0 to allow software-configured IP. If DIPs are non-zero, IP is determined by hardware switches.
- Dynamic Braking Parameters (A suffix = integrated DB transistor on this model)
| Parametro n. | Nome inglese | Nome cinese | Esempio | Osservazioni |
| 100 | DB Resistor Ohms | 制动电阻阻值 | Enter actual resistor value | Must match fitted external braking resistor |
| 101 | DB Resistor Power | 制动电阻功率 | Actual power rating | |
| 102 | DB Level | 制动投入电压 | 780V | Default for 400V class drives |
| 103 | DB Overload | 制动电阻过载保护 | Set per resistor selection |
- Auto Restart on Fault (Opzionale, safety hazard risk)
| Parametro n. | Nome inglese | Nome cinese | Collocamento | Osservazioni |
| 348 | Auto Rstrt Tries | 自动重启次数 | 0=Disabled | 1~5 allowed for fans/conveyors; DO NOT enable for safety-critical machinery |
| 349 | Auto Rstrt Delay | 重启延时 | 5S | Delay between each fault restart attempt |
- Read-only Monitoring Parameters (For observation only, no write)
| Parametro n. | Nome inglese | Nome cinese | Scopo |
| 10 | Output Freq | 输出频率 | Actual output frequency |
| 11 | DC Bus Volts | 直流母线电压 | Normal ~540~580V for 400V class |
| 12 | Corrente di uscita | 输出电流 | Actual motor current |
| 13 | Motor Speed | 电机转速 | Estimated motor speed |
| 220 | Digital In Sts | 数字输入状态 | Diagnose DI terminal status |
- Standard Commissioning Procedure
- Power off → Factory reset parameters → Apply power
- Enter all motor nameplate parameters
- Configure control mode, command source and reference source
- Set accel/decel, limits and overload protection
- Run motor autotune with load decoupled, confirm autotune success
- Ethernet/IP: Set IP address, download PLC project, establish I/O connection
- No-load jog test, verify rotation direction, current and speed
- Loaded trial run, fine-tune accel/decel and torque limits
- Save parameters to drive (parameter backup), export via Studio5000
- Record and archive full parameter set
- Common Commissioning Pitfalls
- STO safety terminals: 20G11NC011AA0NNNNN has no STO module; STO jumpers on control board must be shorted, otherwise safety fault on power-up.
- Autotune fault: Check for open 3-phase motor wiring, nameplate data entry and earth short circuit.
- Replacement 20G11NC011AA0NNNNN → 20G11NC011JA0NNNNN: Parameters can be uploaded/downloaded directly, nearly fully compatible; only verify firmware version.
4. High inertia loads: Extend deceleration time or select higher rated braking resistor