ABB ACS355-03E-07Convertitore di frequenza A3-4

Descrizione del modello: ACS355 machinery drive frequency converter; 03E = 3-phase input, IP20 enclosure; 07A3 = rated output 7.3 UN; 4 = 380–480 V voltage class Part Number: 3AUA0000058188 ✅ Core Electrical Specifications Rated Power: 3.0 kW (light overload / dazio standard) Rated Output Current I₂ₙ: 7.3 Un ingresso: 3-phase 380–480 V ±10%, 48–63 Hz Output: ...

  • Dettagli del prodotto

Descrizione del modello: ACS355 machinery drive frequency convertitore; 03E = 3-phase input, IP20 enclosure; 07A3 = rated output 7.3 UN; 4 = 380–480 V voltage class

Numero di parte: 3AUA0000058188

✅ Specifiche elettriche principali

Potenza nominale: 3.0 kW (light overload / dazio standard)

Rated Output Current I₂ₙ: 7.3 UN

Ingresso: 3-phase 380–480 V ±10%, 48–63 Hz

Produzione: 0 ~ Uₙ, 0–599 Hz

Protezione della custodia: IP20 (without +B063 or other options)

Dimensioni del telaio: R0

Raffreddamento: Air cooling

Motore compatibile: 3 Motore asincrono trifase kW

📦 Dimensions & Peso

Unità: W70 mm × H239 mm × D161 mm

Peso netto: 1.8 kg

Packaged Size: 350×220×130 mm, Peso lordo 2.3 kg

🧩 On-board I/O (Standard)

5 Ingressi digitali (DI)

1 Uscita relè (RO)

2 Ingressi analogici (AI, 0–10 V / 4–20mA)

1 Uscita analogica (AL, 4–20mA)

Modbus RTU integrato (Terminal X1)

Optional plug-in communication adapters: Profibus DP, CANopen, DeviceNet, EtherCAT, ecc.

📌 Applicazioni tipiche

Macchinari generali: trasportatori, tifosi, pompe, miscelatori, small processing machines. Supports standard V/F control and vector control, velocità preimpostate, ramps, multi-set parameter groups.

⚠️Selezione & Note di sostituzione

  1. For IP66 version: add suffix +B063. Dimensions and weight differ completely, part number changes.
  2. Upgrade alternative within ABB portfolio: ACS380. Older ACS350 of the same power can be cross-referenced by current rating.
  3. Fusibile / interruttore automatico: sized per 7.3 A converter standard circuit. Output du/dt reactor is optional.

📎 Common Spare Parts & Accessori

Pannelli di controllo: ACS-CP-A / ACS-CP-D

Input filter, output du/dt filter, resistenza di frenatura (braking chopper built-in)

Adattatori di comunicazione, Moduli di espansione I/O

ABBACS355 (ACS355-03E-07A3-4)|Factory Default Parameters for ABB Standard Macro (9902=1)

Nota: Parameters in Group 99 (dati di targa del motore) have no fixed default values. Enter data per 3 kW motor nameplate after power-up.

Parametro n.Nome del parametroValore predefinitoOsservazioni
9902Application Macro Selection1 ABB Standard MacroDI1 start, DI2 direction, AI1 reference; più ampiamente utilizzato
9904Motor Control Mode3 Scalare (V/F)Opzionale: 1=Vector Speed, 2=Vector Torque
9905Tensione nominale del motore—Follow nameplate; 380 V for standard 3 motore da kW
9906Corrente nominale del motore—Typical value for matched motor ≈6.2 A
9907Motor Rated Frequency—50 Hz for general asynchronous motors
9908Velocità nominale del motore—1440 giri/min (4-palo)
9909Potenza nominale del motore—3.0 kW
1001Ext1 Start/Stop Command2 DI1DI1 closed = Run
1002Ext Direction Command3 DI2DI2=0 Forward, DI2=1 Reverse
1103Ext Reference 1 Selezione1 AI1AI1 0–10 V / 4–20mA
1105Ext Reference 1 Massimo50.0 HzMatches full-scale AI signal
1201Constant Speed Selection0 Not SelectedMulti-speed via DI combination
1301AI1 Minimum0.0 V0 V corrisponde a 0 Hz
1302AI1 Maximum10.0 V10 V corrisponde a 50 Hz
1304AI2 Minimum0.0 VAI2 disabled by default
1401Relay Output RO1 Source0 ReadyOutput when drive is ready
1501AO1 Signal Source102 Frequenza di uscitaAL: 4–20 mA mapped to 0–50 Hz
1504AO1 Minimum Output4 mA
1505AO1 Maximum Output20 mA
2007Minimum Frequency0.0 Hz
2008Maximum Frequency50.0 Hz
2202Tempo di accelerazione 15.0 S
2203Tempo di decelerazione 15.0 S
2102Stop Mode1 Coast Stop2=Ramp Stop
2601U/F Ratio1 LineareSquared for fan/pump duty
3017Overcurrent Trip Limit4×I₂n
3025STO Function0 Alarm OnlyImposta su 1 triggers fault 0044
5302EFB Station Address1Modbus RTU Slave Address
5303Velocità di trasmissione9600
5304Parità0 No Parity, 1 Stop Bit

ACS355 Fault Code List (English with Troubleshooting Guidance)

Codice erroreNome erroreDescrizioneRisoluzione dei problemi comuni
1SOVRACORRENTEOutput current exceeds trip thresholdCortocircuito del motore, danni al cavo, locked load, too short ramp time, incorrect motor data
2DC OVERVOLTDC bus voltage too highDecelerazione rapida, regenerative load, high supply voltage, missing braking resistor
3DEV OVERTEMPIGBT module overtemperatureBlocked airflow, failed fan, temperatura ambiente elevata, sovraccarico, scarsa ventilazione dell'armadio
4SHORT CIRCMotor-side short circuitMotor winding short, phase-to-phase short on power cable, shorted output terminals
6DC UNDERVOLTDC bus voltage insufficientFase di ingresso mancante, open fuse/contact, voltage dip, undersized supply
9MOT OVERTEMPEstimated motor temperature exceededSovraccarico del motore, scarso raffreddamento, incorrect motor thermal protection settings
16EARTH FAULTEarth leakage on motor/power cableDamaged cable insulation, motor insulation failure, ingresso di umidità
22SUPPLY PHASEPerdita di fase in ingresso / 3-phase imbalanceBlown input fuse, poor contactor contacts, unbalanced 3-phase supply
44SAFE TORQUE OFF (STO)STO safety circuit activatedSTO terminals not jumpered, safety loop open, parameter 3025=1 triggers fault
28COMM ERRORBuilt-in EFB bus communication breakModbus wiring, termination resistor, affrontare il conflitto, master offline
35AI1 LOSSAI1 signal below fault thresholdTransmitter wire break, faulty sensor, threshold setting in 3021
36AI2 LOSSAI2 signal lossBroken AI2 wiring, trasmettitore difettoso
41ID RUN FAILMotor identification run failedWrong motor wiring, mismatched power rating, rotore bloccato
51USER PARAM FAULTParameter set corruptedRestore factory defaults and re-enter motor parameters
71FAN FAULTCooling fan failureFan jammed, fan supply fault

✅ Reset Methods: Panel RESET, DI reset, communication reset, ciclo di alimentazione. Fault history stored in Group 04 parametri.

Quick Operation

Ripristino delle impostazioni di fabbrica: Parametro 9606, enter RESET. The drive restarts and loads ABB Standard Macro defaults.

Installation Notes for ABB ACS355-03E-07A3-4 (Frame R0, IP20)

This unit is for cabinet installation only. Grado di protezione IP20, not suitable for direct outdoor exposure.

  1. Montaggio meccanico & Dissipazione del calore
  2. Orientamento di montaggio: Vertical upright installation is mandatory. Do not invert. Side mounting is permitted for R0 frame but vertical is preferred. Cooling air flows bottom-in, top-out; inverted mounting causes overheating fault 0003.
  3. Minimum Clearances

Top ≥75 mm, Bottom ≥75 mm; no mandatory side clearance, reserve space for maintenance.

Stacked multiple drives: hot exhaust from lower unit must not blow directly onto upper unit. Use baffles, staggered layout or independent air ducts.

  1. Mounting Options: Screw fixing or 35 Guida DIN standard da mm. Mounting base must be rigid and flame-retardant. Prevent conductive dust from entering the unit during drilling (risk of short circuit).
  2. Condizioni ambientali

Temperatura ambiente: -10 ~ +50 °C; declassare sopra 40 °C. Nessuna condensa, niente glassa.

Altitudine: Full rating ≤1000 m; derate with increasing altitude above 1000 M.

Prohibited environment: polvere conduttiva, gas corrosivo, strong magnetic fields (near contactors / large single-core cables), heavy vibration or shock.

  1. Sicurezza & Power-off Procedures (Critico)

After disconnection, Aspettare 5 minutes for DC bus capacitors to fully discharge before opening covers, wiring or measuring. Do not touch power terminals or internal PCB when powered.

For permanent magnet motors: motor may generate back EMF when rotating even with supply disconnected. Mechanically lock the shaft before working on motor cables.

Before power-up: Disconnect U2/V2/W2 at the converter, test motor insulation to earth with 1000 V megger. Do not energise if insulation is poor (≥100 MΩ @25°C for ABB motors).

Strictly forbidden: Connect mains supply to U2/V2/W2 output terminals, this will destroy the unit.

  1. Selezione del cavo, Instradamento & EMC
  2. Cable Recommendations

Motor cable: Symmetric shielded VFD cable preferred, reduces bearing currents and EMI. Unshielded standard cables often interfere with sensors and instruments.

Segnali analogici (AI/AO): Double-shielded twisted pair. DI/DO relay signals: shielded twisted pair. Separate power cables and control cables in different trunking, minimum gap ≥20 cm. Cross only at 90° where unavoidable.

Do not mix 24 V low-voltage and 220 V high-voltage circuits inside one cable.

  1. Shield Grounding Rules

360° shield termination with earthing clamp; avoid pigtail earthing (poor high-frequency EMC performance). Shield of motor cable grounded at both converter and motor ends.

PE conductor must be short, thick and connected reliably to cabinet earth bar.

  1. ESSO / Ungrounded Delta System: Remove internal EMC filter earth screw, otherwise earth fault 0016 may occur. Keep screw fitted for standard TN-S systems.
  2. Output-side Restrictions: Do not connect capacitors or surge suppressors to U2/V2/W2. For long motor cables (>50 M), fit output du/dt reactor to protect motor insulation.
  3. Coppia terminale & STO Safety Circuit

Control terminal tightening torque: 0.4 N·m. Power terminals follow datasheet torque specification.

STO (Coppia di sicurezza disattivata): Factory fitted with jumper. If STO function is unused, STO terminals must be permanently jumpered. Open STO triggers fault 0044. For safety applications, wire to safety relay contacts.

Resistenza di frenatura (BRK+, BRK-): Utilizzare cavo schermato, mount close to drive to minimise lead inductance.

  1. Input Protection, Messa a terra & Auxiliary Devices

Fit circuit breaker or fuses on input side, sized for 7.3 Una valutazione. Input AC reactor is recommended to reduce harmonic distortion.

Messa a terra: PE conductors must be home-run separately to earth bar, do not daisy-chain. Never use neutral N as protective earth PE.

Cabinet ventilation: Install cabinet fans to keep internal temperature below 40 °C. Clean filters regularly to prevent blocked cooling paths.

  1. Pre-power-up Checklist
  2. Terminali di potenza: U1/V1/W1 supply, U2/V2/W2 motor, BRK+/braking resistor – verify connections.
  3. Circuiti di controllo: DI/AI/AO, STO jumper, messa a terra dello schermo.
  4. Insulation test passed, no short circuit or earth leakage.
  5. Air path unobstructed.
  6. Motor nameplate data ready; perform motor identification after first power-up.
  7. Installation-related Fault Quick Reference

0003 Sovratemperatura: Blocked airflow, insufficient top/bottom clearance, montaggio invertito, high cabinet temperature

0016 Guasto della Terra: Incorrect shield grounding, EMC screw not removed for IT system, damaged/wet motor cable

0044 STO Fault: STO terminals not jumpered, safety loop open

Fluctuating AI signals: Mixed power/control wiring, poor shield grounding, non-twisted analog cable

ABB ACS355 Model & Part Number List|03E 3-phase 380–480 V, IP20, Filtro EMC integrato, Versione standard

Descrizione del modello:

03 = 3-phase input; E = EMC filter enabled (50 Hz); trailing 4 = 380~480 V; +B063 = IP66 high protection variant (separate order)

Part Number format: 3AUA00000XXXXX (ABB part number, used for purchasing, quotation and customs declaration)

Frame sizes: R0/R1/R3/R4; built-in braking chopper and STO.

ModelloPotenza Nominale kWOutput Current I₂N(UN)TelaioABB Part Number (3AUA)
ACS355-03E-01A2-40.371.2R03AUA0000058186
ACS355-03E-01A9-40.551.9R03AUA0000058243
ACS355-03E-02A4-40.752.4R03AUA0000058187
ACS355-03E-03A3-41.13.3R13AUA0000058184
ACS355-03E-04A1-41.54.1R13AUA0000058185
ACS355-03E-05A6-42.25.6R13AUA0000058189
ACS355-03E-07A3-437.3R03AUA0000058188
ACS355-03E-08A8-448.8R13AUA0000058190
ACS355-03E-12A5-45.512.5R33AUA0000058191
ACS355-03E-15A6-47.515.6R33AUA0000058192
ACS355-03E-23A1-41123.1R33AUA0000058193
ACS355-03E-31A0-41531R43AUA0000058195
ACS355-03E-38A0-418.538R43AUA0000058194
ACS355-03E-44A0-42244R43AUA0000058196

Supplementary Range: 01E Single-phase 200–240 V, IP20, Built-in EMC

ModelloPotenza kWCurrent ATelaioNumero di parte
ACS355-01E-02A4-20.372.4R03AUA0000058174
ACS355-01E-04A7-20.754.7R13AUA0000058175
ACS355-01E-06A7-21.16.7R13AUA0000058176
ACS355-01E-07A5-21.57.5R23AUA0000058177
ACS355-01E-09A8-22.29.8R23AUA0000058178

Accessori comuni & Part Numbers for ACS355

Nome dell'accessorioModelloNumero di parte
Basic Control PanelACS-CP-A3AUA0000040901
Pannello di controllo assistente (cinese)ACS-CP-D3AUA0000040902
Profibus DP AdapterFPBA-013AUA0000040888
CANopen AdapterFCAN-013AUA0000040889
DeviceNet AdapterFDNA-013AUA0000040890
EtherCAT AdapterFECA-013AUA0000040891

Suffix Options (added after model +xxxx)

+B063: IP66 high protection version (for humid, dusty environments)

+N830: Non-coated PCB (standard cabinet version)

+J400: Potentiometer kit

Esempio: ACS355-03E-07A3-4+B063 (IP66 variant, different part number)

Model Code Guide for Export Selection

03E: 3-fase, EMC filter enabled (mainstream for China market) ✅

03U: 3-fase, EMC filter disabled (60 Hz overseas version)

03X: Export special version, not common locally

01E / 01U: Monofase 220 V models

Replacement series: ACS380 (nuova generazione, successor to ACS355)