Descrizione del modello: ACS355 machinery drive frequency convertitore; 03E = 3-phase input, IP20 enclosure; 07A3 = rated output 7.3 UN; 4 = 380–480 V voltage class
Numero di parte: 3AUA0000058188
✅ Specifiche elettriche principali
Potenza nominale: 3.0 kW (light overload / dazio standard)
Rated Output Current I₂ₙ: 7.3 UN
Ingresso: 3-phase 380–480 V ±10%, 48–63 Hz
Produzione: 0 ~ Uₙ, 0–599 Hz
Protezione della custodia: IP20 (without +B063 or other options)
Dimensioni del telaio: R0
Raffreddamento: Air cooling
Motore compatibile: 3 Motore asincrono trifase kW
📦 Dimensions & Peso
Unità: W70 mm × H239 mm × D161 mm
Peso netto: 1.8 kg
Packaged Size: 350×220×130 mm, Peso lordo 2.3 kg
🧩 On-board I/O (Standard)
5 Ingressi digitali (DI)
1 Uscita relè (RO)
2 Ingressi analogici (AI, 0–10 V / 4–20mA)
1 Uscita analogica (AL, 4–20mA)
Modbus RTU integrato (Terminal X1)
Optional plug-in communication adapters: Profibus DP, CANopen, DeviceNet, EtherCAT, ecc.
📌 Applicazioni tipiche
Macchinari generali: trasportatori, tifosi, pompe, miscelatori, small processing machines. Supports standard V/F control and vector control, velocità preimpostate, ramps, multi-set parameter groups.
⚠️Selezione & Note di sostituzione
- For IP66 version: add suffix +B063. Dimensions and weight differ completely, part number changes.
- Upgrade alternative within ABB portfolio: ACS380. Older ACS350 of the same power can be cross-referenced by current rating.
- Fusibile / interruttore automatico: sized per 7.3 A converter standard circuit. Output du/dt reactor is optional.
📎 Common Spare Parts & Accessori
Pannelli di controllo: ACS-CP-A / ACS-CP-D
Input filter, output du/dt filter, resistenza di frenatura (braking chopper built-in)
Adattatori di comunicazione, Moduli di espansione I/O
ABBACS355 (ACS355-03E-07A3-4)|Factory Default Parameters for ABB Standard Macro (9902=1)
Nota: Parameters in Group 99 (dati di targa del motore) have no fixed default values. Enter data per 3 kW motor nameplate after power-up.
| Parametro n. | Nome del parametro | Valore predefinito | Osservazioni |
| 9902 | Application Macro Selection | 1 ABB Standard Macro | DI1 start, DI2 direction, AI1 reference; più ampiamente utilizzato |
| 9904 | Motor Control Mode | 3 Scalare (V/F) | Opzionale: 1=Vector Speed, 2=Vector Torque |
| 9905 | Tensione nominale del motore | — | Follow nameplate; 380 V for standard 3 motore da kW |
| 9906 | Corrente nominale del motore | — | Typical value for matched motor ≈6.2 A |
| 9907 | Motor Rated Frequency | — | 50 Hz for general asynchronous motors |
| 9908 | Velocità nominale del motore | — | 1440 giri/min (4-palo) |
| 9909 | Potenza nominale del motore | — | 3.0 kW |
| 1001 | Ext1 Start/Stop Command | 2 DI1 | DI1 closed = Run |
| 1002 | Ext Direction Command | 3 DI2 | DI2=0 Forward, DI2=1 Reverse |
| 1103 | Ext Reference 1 Selezione | 1 AI1 | AI1 0–10 V / 4–20mA |
| 1105 | Ext Reference 1 Massimo | 50.0 Hz | Matches full-scale AI signal |
| 1201 | Constant Speed Selection | 0 Not Selected | Multi-speed via DI combination |
| 1301 | AI1 Minimum | 0.0 V | 0 V corrisponde a 0 Hz |
| 1302 | AI1 Maximum | 10.0 V | 10 V corrisponde a 50 Hz |
| 1304 | AI2 Minimum | 0.0 V | AI2 disabled by default |
| 1401 | Relay Output RO1 Source | 0 Ready | Output when drive is ready |
| 1501 | AO1 Signal Source | 102 Frequenza di uscita | AL: 4–20 mA mapped to 0–50 Hz |
| 1504 | AO1 Minimum Output | 4 mA | |
| 1505 | AO1 Maximum Output | 20 mA | |
| 2007 | Minimum Frequency | 0.0 Hz | |
| 2008 | Maximum Frequency | 50.0 Hz | |
| 2202 | Tempo di accelerazione 1 | 5.0 S | |
| 2203 | Tempo di decelerazione 1 | 5.0 S | |
| 2102 | Stop Mode | 1 Coast Stop | 2=Ramp Stop |
| 2601 | U/F Ratio | 1 Lineare | Squared for fan/pump duty |
| 3017 | Overcurrent Trip Limit | 4×I₂n | |
| 3025 | STO Function | 0 Alarm Only | Imposta su 1 triggers fault 0044 |
| 5302 | EFB Station Address | 1 | Modbus RTU Slave Address |
| 5303 | Velocità di trasmissione | 9600 | |
| 5304 | Parità | 0 No Parity, 1 Stop Bit |
ACS355 Fault Code List (English with Troubleshooting Guidance)
| Codice errore | Nome errore | Descrizione | Risoluzione dei problemi comuni |
| 1 | SOVRACORRENTE | Output current exceeds trip threshold | Cortocircuito del motore, danni al cavo, locked load, too short ramp time, incorrect motor data |
| 2 | DC OVERVOLT | DC bus voltage too high | Decelerazione rapida, regenerative load, high supply voltage, missing braking resistor |
| 3 | DEV OVERTEMP | IGBT module overtemperature | Blocked airflow, failed fan, temperatura ambiente elevata, sovraccarico, scarsa ventilazione dell'armadio |
| 4 | SHORT CIRC | Motor-side short circuit | Motor winding short, phase-to-phase short on power cable, shorted output terminals |
| 6 | DC UNDERVOLT | DC bus voltage insufficient | Fase di ingresso mancante, open fuse/contact, voltage dip, undersized supply |
| 9 | MOT OVERTEMP | Estimated motor temperature exceeded | Sovraccarico del motore, scarso raffreddamento, incorrect motor thermal protection settings |
| 16 | EARTH FAULT | Earth leakage on motor/power cable | Damaged cable insulation, motor insulation failure, ingresso di umidità |
| 22 | SUPPLY PHASE | Perdita di fase in ingresso / 3-phase imbalance | Blown input fuse, poor contactor contacts, unbalanced 3-phase supply |
| 44 | SAFE TORQUE OFF (STO) | STO safety circuit activated | STO terminals not jumpered, safety loop open, parameter 3025=1 triggers fault |
| 28 | COMM ERROR | Built-in EFB bus communication break | Modbus wiring, termination resistor, affrontare il conflitto, master offline |
| 35 | AI1 LOSS | AI1 signal below fault threshold | Transmitter wire break, faulty sensor, threshold setting in 3021 |
| 36 | AI2 LOSS | AI2 signal loss | Broken AI2 wiring, trasmettitore difettoso |
| 41 | ID RUN FAIL | Motor identification run failed | Wrong motor wiring, mismatched power rating, rotore bloccato |
| 51 | USER PARAM FAULT | Parameter set corrupted | Restore factory defaults and re-enter motor parameters |
| 71 | FAN FAULT | Cooling fan failure | Fan jammed, fan supply fault |
✅ Reset Methods: Panel RESET, DI reset, communication reset, ciclo di alimentazione. Fault history stored in Group 04 parametri.
Quick Operation
Ripristino delle impostazioni di fabbrica: Parametro 9606, enter RESET. The drive restarts and loads ABB Standard Macro defaults.
Installation Notes for ABB ACS355-03E-07A3-4 (Frame R0, IP20)
This unit is for cabinet installation only. Grado di protezione IP20, not suitable for direct outdoor exposure.
- Montaggio meccanico & Dissipazione del calore
- Orientamento di montaggio: Vertical upright installation is mandatory. Do not invert. Side mounting is permitted for R0 frame but vertical is preferred. Cooling air flows bottom-in, top-out; inverted mounting causes overheating fault 0003.
- Minimum Clearances
Top ≥75 mm, Bottom ≥75 mm; no mandatory side clearance, reserve space for maintenance.
Stacked multiple drives: hot exhaust from lower unit must not blow directly onto upper unit. Use baffles, staggered layout or independent air ducts.
- Mounting Options: Screw fixing or 35 Guida DIN standard da mm. Mounting base must be rigid and flame-retardant. Prevent conductive dust from entering the unit during drilling (risk of short circuit).
- Condizioni ambientali
Temperatura ambiente: -10 ~ +50 °C; declassare sopra 40 °C. Nessuna condensa, niente glassa.
Altitudine: Full rating ≤1000 m; derate with increasing altitude above 1000 M.
Prohibited environment: polvere conduttiva, gas corrosivo, strong magnetic fields (near contactors / large single-core cables), heavy vibration or shock.
- Sicurezza & Power-off Procedures (Critico)
After disconnection, Aspettare 5 minutes for DC bus capacitors to fully discharge before opening covers, wiring or measuring. Do not touch power terminals or internal PCB when powered.
For permanent magnet motors: motor may generate back EMF when rotating even with supply disconnected. Mechanically lock the shaft before working on motor cables.
Before power-up: Disconnect U2/V2/W2 at the converter, test motor insulation to earth with 1000 V megger. Do not energise if insulation is poor (≥100 MΩ @25°C for ABB motors).
Strictly forbidden: Connect mains supply to U2/V2/W2 output terminals, this will destroy the unit.
- Selezione del cavo, Instradamento & EMC
- Cable Recommendations
Motor cable: Symmetric shielded VFD cable preferred, reduces bearing currents and EMI. Unshielded standard cables often interfere with sensors and instruments.
Segnali analogici (AI/AO): Double-shielded twisted pair. DI/DO relay signals: shielded twisted pair. Separate power cables and control cables in different trunking, minimum gap ≥20 cm. Cross only at 90° where unavoidable.
Do not mix 24 V low-voltage and 220 V high-voltage circuits inside one cable.
- Shield Grounding Rules
360° shield termination with earthing clamp; avoid pigtail earthing (poor high-frequency EMC performance). Shield of motor cable grounded at both converter and motor ends.
PE conductor must be short, thick and connected reliably to cabinet earth bar.
- ESSO / Ungrounded Delta System: Remove internal EMC filter earth screw, otherwise earth fault 0016 may occur. Keep screw fitted for standard TN-S systems.
- Output-side Restrictions: Do not connect capacitors or surge suppressors to U2/V2/W2. For long motor cables (>50 M), fit output du/dt reactor to protect motor insulation.
- Coppia terminale & STO Safety Circuit
Control terminal tightening torque: 0.4 N·m. Power terminals follow datasheet torque specification.
STO (Coppia di sicurezza disattivata): Factory fitted with jumper. If STO function is unused, STO terminals must be permanently jumpered. Open STO triggers fault 0044. For safety applications, wire to safety relay contacts.
Resistenza di frenatura (BRK+, BRK-): Utilizzare cavo schermato, mount close to drive to minimise lead inductance.
- Input Protection, Messa a terra & Auxiliary Devices
Fit circuit breaker or fuses on input side, sized for 7.3 Una valutazione. Input AC reactor is recommended to reduce harmonic distortion.
Messa a terra: PE conductors must be home-run separately to earth bar, do not daisy-chain. Never use neutral N as protective earth PE.
Cabinet ventilation: Install cabinet fans to keep internal temperature below 40 °C. Clean filters regularly to prevent blocked cooling paths.
- Pre-power-up Checklist
- Terminali di potenza: U1/V1/W1 supply, U2/V2/W2 motor, BRK+/braking resistor – verify connections.
- Circuiti di controllo: DI/AI/AO, STO jumper, messa a terra dello schermo.
- Insulation test passed, no short circuit or earth leakage.
- Air path unobstructed.
- Motor nameplate data ready; perform motor identification after first power-up.
- Installation-related Fault Quick Reference
0003 Sovratemperatura: Blocked airflow, insufficient top/bottom clearance, montaggio invertito, high cabinet temperature
0016 Guasto della Terra: Incorrect shield grounding, EMC screw not removed for IT system, damaged/wet motor cable
0044 STO Fault: STO terminals not jumpered, safety loop open
Fluctuating AI signals: Mixed power/control wiring, poor shield grounding, non-twisted analog cable
ABB ACS355 Model & Part Number List|03E 3-phase 380–480 V, IP20, Filtro EMC integrato, Versione standard
Descrizione del modello:
03 = 3-phase input; E = EMC filter enabled (50 Hz); trailing 4 = 380~480 V; +B063 = IP66 high protection variant (separate order)
Part Number format: 3AUA00000XXXXX (ABB part number, used for purchasing, quotation and customs declaration)
Frame sizes: R0/R1/R3/R4; built-in braking chopper and STO.
| Modello | Potenza Nominale kW | Output Current I₂N(UN) | Telaio | ABB Part Number (3AUA) |
| ACS355-03E-01A2-4 | 0.37 | 1.2 | R0 | 3AUA0000058186 |
| ACS355-03E-01A9-4 | 0.55 | 1.9 | R0 | 3AUA0000058243 |
| ACS355-03E-02A4-4 | 0.75 | 2.4 | R0 | 3AUA0000058187 |
| ACS355-03E-03A3-4 | 1.1 | 3.3 | R1 | 3AUA0000058184 |
| ACS355-03E-04A1-4 | 1.5 | 4.1 | R1 | 3AUA0000058185 |
| ACS355-03E-05A6-4 | 2.2 | 5.6 | R1 | 3AUA0000058189 |
| ACS355-03E-07A3-4 | 3 | 7.3 | R0 | 3AUA0000058188 |
| ACS355-03E-08A8-4 | 4 | 8.8 | R1 | 3AUA0000058190 |
| ACS355-03E-12A5-4 | 5.5 | 12.5 | R3 | 3AUA0000058191 |
| ACS355-03E-15A6-4 | 7.5 | 15.6 | R3 | 3AUA0000058192 |
| ACS355-03E-23A1-4 | 11 | 23.1 | R3 | 3AUA0000058193 |
| ACS355-03E-31A0-4 | 15 | 31 | R4 | 3AUA0000058195 |
| ACS355-03E-38A0-4 | 18.5 | 38 | R4 | 3AUA0000058194 |
| ACS355-03E-44A0-4 | 22 | 44 | R4 | 3AUA0000058196 |
Supplementary Range: 01E Single-phase 200–240 V, IP20, Built-in EMC
| Modello | Potenza kW | Current A | Telaio | Numero di parte |
| ACS355-01E-02A4-2 | 0.37 | 2.4 | R0 | 3AUA0000058174 |
| ACS355-01E-04A7-2 | 0.75 | 4.7 | R1 | 3AUA0000058175 |
| ACS355-01E-06A7-2 | 1.1 | 6.7 | R1 | 3AUA0000058176 |
| ACS355-01E-07A5-2 | 1.5 | 7.5 | R2 | 3AUA0000058177 |
| ACS355-01E-09A8-2 | 2.2 | 9.8 | R2 | 3AUA0000058178 |
Accessori comuni & Part Numbers for ACS355
| Nome dell'accessorio | Modello | Numero di parte |
| Basic Control Panel | ACS-CP-A | 3AUA0000040901 |
| Pannello di controllo assistente (cinese) | ACS-CP-D | 3AUA0000040902 |
| Profibus DP Adapter | FPBA-01 | 3AUA0000040888 |
| CANopen Adapter | FCAN-01 | 3AUA0000040889 |
| DeviceNet Adapter | FDNA-01 | 3AUA0000040890 |
| EtherCAT Adapter | FECA-01 | 3AUA0000040891 |
Suffix Options (added after model +xxxx)
+B063: IP66 high protection version (for humid, dusty environments)
+N830: Non-coated PCB (standard cabinet version)
+J400: Potentiometer kit
Esempio: ACS355-03E-07A3-4+B063 (IP66 variant, different part number)
Model Code Guide for Export Selection
03E: 3-fase, EMC filter enabled (mainstream for China market) ✅
03U: 3-fase, EMC filter disabled (60 Hz overseas version)
03X: Export special version, not common locally
01E / 01U: Monofase 220 V models
Replacement series: ACS380 (nuova generazione, successor to ACS355)