Carlo Gavazzi WM12-96.AV5.3.3.X Multi-functional Power Meter - Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari

Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Di Contatto |

Carlo Gavazzi WM12-96.AV5.3.3.X Multi-functional Power Meter - Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari

contatore elettrico/elettrico/

Carlo Gavazzi WM12-96.AV5.3.3.X Multi-functional Power Meter

Carlo Gavazzi WM12-96.AV5.3.3.X is a 96×96mm panel-mounted three-phase multi-functional power meter. It adopts TRMS True RMS measurement technology, designed for 400V three-phase four-wire systems, with 230V AC power supply and no RS485 communication function. Its core advantages include high-precision measurement (Voltage/Current ±0.5% FS), multi-parameter display (12 measuring pages), wide measuring range (0.03-6Una corrente) e alto ...

  • Dettagli del prodotto

Carlo Gavazzi WM12-96.AV5.3.3.X is a 96×96mm panel-mounted three-phase multi-functional power meter. It adopts TRMS True RMS measurement technology, designed for 400V three-phase four-wire systems, with 230V AC power supply and no RS485 communication function. Its core advantages include high-precision measurement (Voltage/Current ±0.5% FS), multi-parameter display (12 measuring pages), wide measuring range (0.03-6Una corrente) and high protection degree (IP65 front panel). It is ideally applied in industrial automation, edifici commerciali, data centers and OEM equipment. It can monitor power parameters in real time, help users optimize energy consumption and reduce operating costs.

  1. Definizione del codice modello
SezioneCodiceDescrizione
Codice serieWM12-96Carlo Gavazzi WM12 series 96×96mm panel-mounted multi-functional power meter
Range CodeAV5380/660V line-line, 5(6)A AC current input, suitable for 400V power system
Tipo di sistema3Sistema trifase a quattro fili (configurable as three-phase three-wire, ARON, two-phase or single-phase)
Power Supply Type3230V AC ±15% +10%, 50-60Hz (Code A=24VAC, B=48VAC, C=115VAC, D=18-60VDC)
Function OptionXWithout RS485 output (S=With RS485 MODBUS/JBUS output)

Numero d'ordine: WM12-96AV533X (Standard single package)

  1. Main Technical Specifications
CategoriaArticoloValoreRemark
Informazioni di baseTipo di prodottoThree-phase multi-functional power meterBuilt-in programming keypad, TRMS true RMS measurement
Display14mm LED, 3×3 digitsRefresh rate: 700SM, 12 measuring pages
Tipo di montaggioPanel mountingDimensione:96×96×63mm, Cut-out size:61.4×61.4mm
Classe di protezioneFront IP65, Terminal IP20Comply with NEMA4x/12 standard
Electrical SpecsIntervallo di tensione380/660V L-L, 185-460V L-NAV5 range, Precisione: ±0.5% FS +1 digit
Intervallo corrente5(6)A AC, Phase current:0.03-6UN, Neutral current:0.09-6UNPrecisione: ±(0.5% FS +1 digit) within 0.25-6A
Tensione di alimentazione230V AC ±15% +10%, 50-60HzConsumo energetico:4.5VA
Parametri misuratiVoltaggio, Attuale, Energia, Fattore di potenza, Frequenza, Richiesta, Maximum valueSystem-wide & phase-separated measurement supported
PrecisioneActive/Apparent Power±(1% FS +1 digit) (0.25-6UN)±(1% FS +5 digits) at 0.03-0.25A
Potenza reattiva±(2% FS +1 digit) (0.25-6UN)±(2% FS +5 digits) at 0.03-0.25A
Frequenza±0.1% Hz (48-62Hz)Sampling:1400 samples/s@50Hz, 1700 samples/s@60Hz
Neutral Current±(1.5% FS +1 digit) (0.25-6UN)±7 digits at 0.09-0.25A
ComunicazioneInterfacciaNessuno (X version)S version: RS485, MODBUS/JBUS, 9600 velocità di trasmissione
Communication DistanceMax 1200m for S version, 2/4-wire connection
Ambient SpecsTemperatura operativa-5℃ ~ +50℃RH<90% non-condensing @40℃
Temperatura di conservazione-30℃ ~ +60 ℃RH<90% non-condensing @40℃
Classe di isolamentoOvervoltage Category III (CEI 60664)Withstand 4000VAC between input and power supply for 1 minuto
Physical SpecsMateriale dell'alloggiamentoSelf-extinguishing ABS (UL 94 V-0)Peso: approx.400g (with package)
TerminaliScrew typeMax cable cross-section:2.5mm², 5(6)A current input
CertificazioneCEComply with EN50084-1 Class A, EN61000-6-2 Class A
ULcULus certified, meet North American safety standards
EMC StandardComply with EN61000-4-51.2/50μs surge immunity
  1. Full Model List of WM12-96 Series
Range CodeTipo di sistemaAlimentazione elettricaFunzioneModelloOrdine n.
AV53(3-phase 4-wire)UN(24VCA)X(No RS485)WM12-96.AV5.3.A.XWM12-96AV53AX
S(RS485)WM12-96.AV5.3.A.SWM12-96AV53AS
B(48VCA)XWM12-96.AV5.3.B.XWM12-96AV53BX
SWM12-96.AV5.3.B.SWM12-96AV53BS
C(115VCA)XWM12-96.AV5.3.C.XWM12-96AV53CX
SWM12-96.AV5.3.C.SWM12-96AV53CS
3(230VCA)XWM12-96.AV5.3.3.XWM12-96AV533X
SWM12-96.AV5.3.3.SWM12-96AV533S
D(18-60VCC)XWM12-96.AV5.3.D.XWM12-96AV53DX
SWM12-96.AV5.3.D.SWM12-96AV53DS
AV63(3-phase 4-wire)3(230VCA)XWM12-96.AV6.3.3.XWM12-96AV633X
SWM12-96.AV6.3.3.SWM12-96AV633S

Modelli speciali: WM12-DIN (DIN rail type), WM14-96 (with 15th harmonic analysis)

  1. Sostituzione & Equivalent Models

4.1 Internal Carlo Gavazzi Replacement

Old ModelNew ModelReplacement Description
WM1-96WM12-96Upgraded true RMS measurement, maggiore precisione, added demand & max value display
WM12-96.AV5.3.D.SWM12-96.AV5.3.D.SPienamente compatibile, optimized firmware, support latest MODBUS protocol

4.2 Cross-brand Equivalent

MarcaModello equivalenteVantaggi
SchneiderPM2000Più conveniente, higher front IP65 protection
Siemens7KM2112Support more system types including ARON & two-phase, flexible programming
ABBE20012 display pages for clearer reading, standard 96×96mm mounting size
  1. Campi di applicazione & Cases

5.1 Applicazioni consigliate

ApplicazioneTypical Working ConditionVantaggi
Automazione industrialeMotor control center, distribution cabinet, PLC systemTRMS measurement, perfect for non-linear loads with high precision
Edifici commercialiAria condizionata centralizzata, lighting system, elevator control3-phase 4-wire measurement, monitor unbalanced load, IP65 suit for machine room
Energia rinnovabilePV inverter, wind power systemRichiesta & peak value monitoring, support single/three-phase systems
Centro datiUPS system, server cabinet power distributionAlta precisione, low power consumption 4.5VA, stable 24h operation
Attrezzatura OEMIndustrial machinery, attrezzature mediche, testing instrumentStandard 96×96mm easy integration, optional RS485 communication

5.2 Not Recommended Applications

High voltage system (over 660V L-L, voltage transformer required)

High current system (over 6A, current transformer required)

Explosion hazardous area (non-explosion-proof design)

Underwater or long-term humid environment (only IP20 for terminals)

5.3 Application Cases

Caso 1: Motor Control Center Renovation for Automobile Factory

Original equipment: Analog pointer meters with inaccurate reading and no data recording

Soluzione: WM12-96.AV5.3.3.S with RS485 + SCADA system

Effect: Real-time monitor three-phase current, voltage and power, detect unbalanced load, save 15% energia, annual electricity saving about 80,000 RMB

Caso 2: Energy Management System for Commercial Complex

Richiesta: Monitor power parameters of distribution cabinets on 12 floors, lettura contatori a distanza

Soluzione: 12 sets WM12-96.AV5.3.3.S connected to central controller via MODBUS bus

Effect: Auto generate energy consumption report, identify high-energy areas, optimize power distribution, save 20% energy yearly

  1. Air Shipment Compliance & Certificazione

6.1 Shipping Confirmation

ArticoloStatoSpiegazione
Built-in Lithium BatteryNOExternal power supply only
Dangerous Goods ClassificationNon-dangerous goodsComply with IATA DGR rules, no special shipping limit
Transport RestrictionNessunoShipped as general electronic goods
ConfezioneStandard anti-static packagePrevent static damage during transit

6.2 Documenti di certificazione

CE Certificate: Available on official Carlo Gavazzi website (Doc ID:WM12 96 DS ENG 100317)

UL Certificate: Apply via global Carlo Gavazzi support center

Manufacturer Declaration: Include EMC, safety and RoHS compliance statement

  1. Linee guida per la selezione
  2. Range Selection: AV5 for 400V system (380/660V L-L), AV6 for 100V system (120/208V L-L)
  3. Abbinamento di potenza: Select A/B/C/3/D code according to on-site power supply to avoid damage
  4. Comunicazione: Choose S version for remote monitoring, X version for local display only
  5. Montaggio: Panel cut-out size 61.4×61.4mm; current signal must connect via CT, direct connection forbidden
  6. System Setting: Reset via keypad to three-phase three-wire, ARON, two-phase or single-phase as required
  7. Accessori coordinati
AccessorioModelloFunzione
Trasformatore di correnteCT-500/5500A/5A for large current measurement
Trasformatore di tensioneVT-400/100400V/100V for high voltage measurement
Modulo di comunicazioneRS485-USBConnect meter to PC for parameter setting & data reading
Mounting KitWM12-MOUNTFixing screws and gaskets for panel installation
Configuration SoftwareGavazzi Config ToolRemote parameter setting and file generation

Full Model List of Carlo Gavazzi Multi-functional Power Meters

  1. General Coding Rule
SezioneCodiceSenso
SerieWM12-9696×96mm panel type
WM12-DINDIN rail type (4 moduli)
AllineareAV5380/660V L-L, 400Sistema V
AV6120/208V L-L, 100Sistema V
Sistema1Monofase
2Three-phase three-wire
3Three-phase four-wire
EnergiaA=24VAC, B=48VAC, C=115VAC, 3=230VAC, D=18-60VDC
FunzioneX=No RS485, S=With RS485 MODBUS
  1. Complete WM12-96 & WM12-DIN Model List

WM12-96 Panel Mount

AV5 Series (400V System)

All single-phase / trifase a tre fili / three-phase four-wire models with all power supply & communication options are fully listed as above.

AV6 Series (100V System)

Full range models are available in single-phase, three-phase three-wire and three-phase four-wire types.

WM12-DIN Rail Mount

Mainly three-phase four-wire AV5 & AV6 versions with all power supply and communication options.

  1. Extended High-end Models
ModelloCaratteristicaOrdine n.
WM14-96.AV5.3.3.S15th harmonic analysisWM14-96AV533S
WM30-96.AV5.3.3.S0.2 alta precisione, 32nd harmonic FFT analysisWM30-96AV533S

Prec: