Danfoss VZH117AGANA Variable Speed Scroll Compressor - Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari

Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Di Contatto |

 Danfoss VZH117AGANA Variable Speed Scroll Compressor - Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari

elettrico/

Danfoss VZH117AGANA Variable Speed Scroll Compressor

Danfoss VZH117AGANA is a 2nd-generation variable speed scroll compressor with a displacement of 116.9 cm³. It adopts IPM Interior Permanent Magnet synchronous motor, designed for R410A refrigerant systems. Rated voltage range: 380-480V/3PH/50-60Hz, cooling capacity: ca. 8~11 tons of refrigeration. Its core advantages include high efficiency across full speed range (≥92%), wide frequency adjustment (25-100Hz), precise ...

  • Dettagli del prodotto

Danfoss VZH117AGANA is a 2nd-generation variable speed scroll compressor with a displacement of 116.9 cm³. It adopts IPM Interior Permanent Magnet synchronous motor, designed for R410A refrigerant systems. Rated voltage range: 380-480V/3PH/50-60Hz, cooling capacity: ca. 8~11 tons of refrigeration. Its core advantages include high efficiency across full speed range (≥92%), wide frequency adjustment (25-100Hz), precise temperature control (±0.5°C) and low vibration & basso rumore. It is ideally applied to commercial air conditioners, precision air conditioners, heat pump systems and combined parallel systems, which can effectively boost system energy efficiency (energy saving over 30%) and reduce operating costs.

  1. Definizione del codice modello
SezioneCodiceSenso
Codice serieVZHDanfoss 2nd-gen Variable Speed High-efficiency Scroll Compressor
Displacement117Nominal displacement 116.9 cm³
Codice tensioneG380-480V 3-phase 50/60Hz; Code J: 200-240V
ConfigurazioneUNSingle unit; B: Parallel connection, brazed joint with oil sight glass
Motor TypeNBuilt-in IPM motor, no internal motor protection (protected by inverter)
RefrigerantUNExclusive for R410A, matched with POE 160SZ refrigeration oil

Ordine n.: 120G0014 (single package)

  1. Main Technical Specifications
CategoriaArticoloValoreRemark
Informazioni di baseRefrigerantR410ANot applicable for other refrigerants
Motor TypeBuilt-in IPM motorEfficiency ≥92% full speed range
Capacity ControlInverter-drivenMatched with Danfoss CDS303 dedicated inverter
Gamma di frequenza25-100Hz (1500-6000giri/min)Base speed 3000rpm@50Hz, 3600rpm@60Hz
PrestazioneDisplacement116.9 cm³Standard working condition
Cooling Capacity@50Hz27.9kW (8.0TR)ARI standard condition
Cooling Capacity@60Hz37.9kW (10.8TR)ARI standard condition
Rated Load Ampere (RLA)44UN380V 50Hz
Max Trip Current (MMT)55UNInverter protection setting
ElettricoAlimentazione elettrica380-480V 3PH 50/60HzWorking voltage: 342-528V
Resistenza della bobina0.08Ω @25℃Phase-to-phase resistance
Classe di protezioneIP54 (with cable gland)Terminal box protection standard
MeccanicoSuction Pipe Size1 3/8 in ODFBrazed connection
Discharge Pipe Size7/8 in ODFBrazed connection
Overall Height542mmIncluding valves
Outer Diameter243mmShell outer size
Peso netto64.922kgExcluding package
Oil Charge Volume3.6lPOE 160SZ refrigeration oil
PressioneMax High Side Working Pressure48.7sbarraOperating pressure
Max Low Side Working Pressure33.3sbarraOperating pressure
High Side Test Pressure45sbarraHydraulic test pressure
Low Side Test Pressure33.3sbarraHydraulic test pressure
TemperaturaMax Discharge Temperature150℃Discharge temperature limit
Max Suction Temperature55℃Suction temperature limit
Min Ambient Temperature-35℃Common limit for high & low side
CertificazioneCE CertificateComply with EU standards
UL CertificateComply with US standards
UKCA CertificateComply with UK standards
RoHS ComplianceSÌ (partial exemption)Meet EU & China RoHS requirements
  1. Full VZH Series Model List (R410A)
DisplacementCodice tensioneTipoModelloNumero d'ordine
88Cm³GSingleVZH088AGANA120G0078
GParallelVZH088BGANA120G0079
JSingleVZH088AJANA120G0080
JParallelVZH088BJANA120G0081
117Cm³GSingleVZH117AGANA120G0014
GParallelVZH117BGANA120G0083
JSingleVZH117AJANA120G0084
JParallelVZH117BJANA120G0085
170Cm³GSingleVZH170AGANA120G0086
GParallelVZH170BGANA120G0087
JSingleVZH170AJANA120G0088
JParallelVZH170BJANA120G0089

Modelli speciali:

VZH117CGANA (industrial package, 120G0226)

VZH117CJDMA (compatible with R452B/R454B, 120G0327)

  1. Sostituzione & Equivalent Models

4.1 Internal Danfoss Replacement

Old ModelNew ModelReplacement Description
VSH117AGANA (fixed speed)VZH117AGANAVariable speed upgrade, efficiency improved over 30%, temp control accuracy ±0.5℃
1st-gen VZH117AGANA2nd-gen VZH117AGANAOptimized motor design, wider operating range, higher IPM efficiency

4.2 Cross-brand Equivalent

Old ModelNew ModelReplacement Description
VSH117AGANA (fixed speed)VZH117AGANAVariable speed upgrade, efficiency improved over 30%, temp control accuracy ±0.5℃
1st-gen VZH117AGANA2nd-gen VZH117AGANAOptimized motor design, wider operating range, higher IPM efficiency
  1. Scenari applicativi & Industry Cases

5.1 Applicazioni consigliate

ApplicazioneTypical Working ConditionVantaggi fondamentali
Commercial Air ConditionerRooftop unit, modular chiller, water chillerWide frequency range, high part-load efficiency
Precision Air ConditionerCentro dati, laboratory, attrezzature medicheHigh temperature control accuracy, bassa vibrazione & rumore
Heat Pump SystemCommercial heat pump, hot water unitHigh pressure ratio design, excellent low-temperature heating performance
Process CoolingIndustrial equipment cooling, lavorazione degli alimentiStable output, adapt to harsh working conditions
Combined Parallel SystemVZH117 + SH161/SH184Energy saving over 30%, adapt to large load fluctuation
MarcaModello equivalenteVantaggi
CopelandZPV114KCE-TFD-420Higher IPM motor efficiency, superior oil management system
EmersonCopeland Scroll Variable SpeedHigher integration of Danfoss CDS303 inverter, more complete protection functions
Mitsubishi ElectricEHV117Stronger parallel connection capability, support mixed parallel of VZH & SH series

5.2 Not Recommended Applications

Household air conditioners (excessive power for residential use)

Systems using chlorine-containing refrigerants (only R410A applicable)

Oil-free lubrication systems (POE oil lubrication required)

Ultra-high pressure working conditions (exceeding 48.7bar high-side limit)

5.3 Practical Cases

Caso 1: Precision Air Conditioner Renovation for Data Center

Original system: Fixed-speed compressor, high power consumption, large temperature fluctuation

Soluzione: VZH117AGANA + CDS303 dedicated inverter

Effect: Energy consumption reduced by 35%, temperature fluctuation controlled within ±0.3℃, annual electricity cost saved about 120,000 RMB

Caso 2: Rooftop Unit Project for Commercial Complex

Richiesta: 24-hour continuous operation with wide load fluctuation (10%-100%)

Soluzione: Parallel system composed of 4 sets VZH117AGANA compressors

Effect: Part-load efficiency increased by 40%, starting current reduced by 70%, longer service life

  1. Air Shipment Compliance & Certification Guide

6.1 Air Transport Confirmation

ArticoloStatoSpiegazione
Built-in Lithium BatteryNOEquipped with permanent magnet motor only
Dangerous Goods ClassificationNon-dangerous goodsComply with IATA DGR Class 9 regulation
Transport RestrictionNo special restrictionShipped as general cargo
Packaging StandardSingle / Industrial packageFollow standard Danfoss packaging specification

6.2 Documenti di certificazione

CE Certificate: Available on Danfoss official product page

UL Certificate: Apply via Danfoss global product store

Manufacturer Declaration: Including RoHS, REACH compliance statement

  1. Regole di selezione
  2. Capacity matching: VZH117AGANA equals 8-11TR, suitable for 1000-2000㎡ commercial space
  3. Voltage selection: G code for 380-480V, J code for 200-240V
  4. System matching: Must use original Danfoss CDS303 inverter
  5. Lubrication rule: Only original POE 160SZ refrigeration oil is allowed
  6. Installation standard: Suction pipe 1 3/8 pollice, discharge pipe 7/8 pollice, brazed connection
  7. Accessori coordinati
AccessorioModelloFunzione
InvertitoreCDS303 18.5kWDedicated drive with full protection
Installation Kit120Z0066Rubber pad, bolts and gaskets
Oil SeparatorSpecial modelNecessary for long pipeline system (>10M)
Discharge Temperature Protector7750009Prevent over-high discharge temperature
Oil Sight Glass8156019Real-time oil level observation

Difetti comuni & Troubleshooting for Danfoss VZH117AGANA Variable Speed Scroll Compressor

  1. Failure to Start & Inverter Alarm

Sintomo: No operation after power on, inverter alarms overcurrent, perdita di fase, overload or undervoltage

Cause

  1. 3-phase power phase loss, unstable low voltage
  2. Wrong inverter parameter setting
  3. Internal scroll seizure or bearing stuck
  4. Loose main circuit wiring, poor contactor performance
  5. Damaged inverter power module

Soluzioni

  1. Measure actual 3-phase voltage, keep stable voltage at 360~420V
  2. Reset standard parameters: 4-motore a poli, rated current 44A
  3. Manually rotate fan wheel, disassemble and repair if stuck
  4. Fasten all wiring terminals, replace aging contactors
  5. Repair or replace original Danfoss CDS302/CDS303 inverter
  6. Excessive Operating Current & Frequent Overload Protection

Sintomo: Running current far exceeds 44A, easy to trip under high frequency

Cause

  1. Overcharged refrigerant leads to excessive system load
  2. Dirty condenser causes poor heat dissipation and high high-side pressure
  3. Temperatura ambiente eccessivamente elevata
  4. Long-term full-load high-frequency operation
  5. Liquid slugging increases operating resistance

Soluzioni

  1. Recycle redundant R410A refrigerant to standard filling quantity
  2. Clean condenser fins thoroughly
  3. Install unit away from heat source
  4. Set maximum speed limit on inverter
  5. Install gas-liquid separator to avoid liquid refrigerant return
  6. Excessively High Discharge Temperature (Over 135℃)

Sintomo: High temperature shutdown, sharp cooling capacity drop

Cause

  1. Insufficient refrigerant leads to superheated suction gas
  2. Abnormal expansion valve opening
  3. Insufficient outdoor fan speed and air volume
  4. System partial blockage
  5. Long-term low-frequency light-load operation

Soluzioni

  1. Supplement R410A refrigerant and check leakage points
  2. Adjust expansion valve opening matching actual load
  3. Repair outdoor fan to reach rated speed
  4. Flush pipeline to remove dirt blockage
  5. Adjust operating frequency range reasonably
  6. Abnormal Noise & Severe Vibration

Sintomo: Loud operating noise, unit shaking and pipeline resonance

Cause

  1. Aging shock absorption pad, uneven installation base
  2. No flexible vibration-absorbing pipe on suction/discharge pipeline
  3. Insufficient refrigeration oil causes internal wear
  4. Liquid slugging impact scroll components
  5. Loose compressor fixing bolts

Soluzioni

  1. Replace thickened shock pad and level installation base
  2. Install refrigeration vibration-absorbing hose on high/low pressure pipelines
  3. Check and replenish POE refrigeration oil regularly
  4. Add gas-liquid separator to avoid liquid slugging
  5. Fasten all fixing bolts and arrange pipelines properly
  6. Insufficient Cooling Capacity & Weak Frequency Rising

Sintomo: Slow cooling speed, no capacity improvement after frequency rise

Cause

  1. Abnormal pressure sensor signal
  2. Low inverter output torque parameter
  3. Air remaining inside system, incomplete vacuum pumping
  4. Internal scroll wear leads to low volumetric efficiency
  5. Blocked filter causes insufficient circulation flow

Soluzioni

  1. Calibrate pressure transmitter zero point and range
  2. Increase inverter torque gain parameter
  3. Re-pump deep vacuum to exhaust internal air
  4. Replace compressor if serious wear occurs
  5. Replace filter drier and dredge pipelines
  6. Frequent Start-Stop Cycle

Sintomo: Excessive start-stop times exceeding 12 volte all'ora

Cause

  1. Too narrow temperature & pressure control differential value
  2. Severe system pressure fluctuation
  3. Unstable grid voltage
  4. Over-low protection threshold causes false shutdown

Soluzioni

  1. Widen temperature and pressure start-stop differential range
  2. Stabilize system refrigerant pressure and optimize throttling control
  3. Install voltage stabilizer for 3-phase power supply
  4. Properly raise protection threshold to eliminate false protection
  5. Lubrication System Fault

Sintomo: Fast internal wear, short service life and frequent abnormal noise

Cause

  1. Failure of first oil change after 500 working hours
  2. Mixed use of non-specified refrigeration oil, oil deterioration
  3. Unbalanced oil distribution in parallel units
  4. Poor oil fluidity under long-term low-temperature operation

Soluzioni

  1. Strict maintenance rule: first oil change at 500h, regular change every 2000h / 1 year
  2. Only use designated Danfoss POE 160SZ refrigeration oil, prohibit mineral oil mixing
  3. Check oil balance pipeline smoothness
  4. Preheat unit before loading under low ambient temperature
  5. Refrigerant Leakage Fault

Sintomo: Gradual system pressure drop, worse cooling effect

Cause

  1. Vibration crack on ODF brazed welding seam
  2. Loose sealing of oil balance connector
  3. Pinhole leakage on compressor shell
  4. Pipeline joint desoldering caused by thermal expansion and contraction

Soluzioni

  1. Pressurize for leakage detection and re-weld cracked joints
  2. Fasten oil balance connector and replace sealing gasket
  3. Use special leak repair agent for slight shell leakage, replace compressor for severe leakage
  4. Reserve expansion margin for pipelines to reduce thermal stress
  5. Out-of-control Variable Speed Regulation

Sintomo: Unstable rotating speed, no response to speed command

Cause

  1. Signal interference between inverter and main control board
  2. Abnormal built-in motor Hall sensor
  3. Inverter control board program disorder
  4. Grid frequency fluctuation affects variable speed output

Soluzioni

  1. Shield and ground communication wire, keep away from high-power power lines
  2. Inspect Hall signal of permanent magnet motor
  3. Restore inverter factory settings and re-match compressor parameters
  4. Stabilize grid power frequency
  5. Daily Maintenance Precautions
  6. Do not use non-original universal inverter, easy to burn out motor without built-in protection
  7. Only adopt R410A refrigerant, no alternative refrigerant allowed
  8. Control start-stop times ≤12 times per hour to extend service life
  9. POE oil has strong water absorption, complete vacuum pumping and sealing required after maintenance
  10. Ensure sufficient condenser heat dissipation under high temperature summer working condition

Prec:

Prossimo:

Lascia una risposta

Lasciate un messaggio