Caratterizzato da struttura compatta, high-efficiency control and reliable performance, Danfoss FC-051P18KT4E20H3BXCXXXSXXX inverter delivers outstanding performance in fields including fans & pompe dell'acqua, movimentazione dei materiali, cibo & textile industry, trattamento dell'acqua, achieving an average energy-saving rate of 30-50%. It also extends service life of equipment, improves product quality and cuts maintenance costs. Reasonable configuration shall be conducted according to load characteristics, ambient conditions and control requirements during model selection to maximize its technical advantages.
- Definizione del codice modello
| Codice | Senso | Descrizione dettagliata |
| FC-051 | Codice serie | VLT® Micro Drive FC-51 Compact General-purpose Inverter Series |
| P18K | Potenza nominale | Matched motor power: 18.5kW / 25HP |
| T4 | Power Supply Spec. | T=Three-phase input; 4=380-480VAC voltage class |
| E20 | Classe di protezione | Protezione IP20, chassis mounting type |
| H3 | RFI Filter | Equipped with RFI Class A1/B (C1) filter |
| B | Unità freno | Built-in brake chopper |
| X | Local Control Panel | Without local control panel (LCP to be ordered separately) |
| C | PCB Coating | Coated printed circuit board for higher reliability in harsh environments |
| X | Power Option | Standard power configuration without special options |
| X | Adapter A | Standard cable entry |
| X | Adapter B | No extra adapters |
| SXXX | Versione del software | Latest standard software version |
| M5 | Dimensioni del telaio | M5 frame (corresponding to 18.5kW power grade) |
| Ordine n. | 132F0060 | Codice identificativo univoco ufficiale |
- Specifiche tecniche principali
| Categoria | Specifica | Osservazioni |
| Parametri di base | ||
| Potenza nominale | 18.5kW / 25HP | Matched motor power |
| Corrente di uscita nominale | 37UN (Pesante) / 34UN (Light-duty) | Current values for different load types |
| Tensione in ingresso | 3-phase 380-480VAC | Allowable fluctuation: ±10% |
| Frequenza di ingresso | 50/60Hz | Auto-adaptive |
| Tensione di uscita | 0~100% of input voltage | Varies with frequency |
| Frequenza di uscita | 0-200Hz (VVC+ Mode) / 0-400Hz (U/f Mode) | Controllo vettoriale / V/f ratio control |
| Control Features | ||
| Modalità di controllo | VVC+ (Voltage Vector Control), U/f Control | Closed-loop vector control available (encoder optional) |
| Capacità di sovraccarico | 150% corrente nominale per 60 secondi | Standard overload protection |
| Acc/Dec Time | 0.1~3600s | Acceleration and deceleration time set independently |
| Ingresso digitale | 5 ingressi programmabili | Support PNP/NPN logic, 0-24VCC |
| Ingresso analogico | 1 channel 0-10V/4-20mA | Programmable functions |
| Uscita relè | 2 canali (1 NO + 1 NC) | Max switching capacity: 250VAC/2A |
| Physical Properties | ||
| Grado di protezione | IP20 | Chassis mounting |
| Metodo di raffreddamento | Raffreddamento naturale + forced air cooling | M5 frame with built-in fan |
| Temperatura ambiente | -20°C ~ +50°C | Derating operation required above 40°C |
| Umidità relativa | 5%~95%, senza condensa | Standard industrial environment requirement |
| Peso | ca. 9.98kg (net weight) | ca. 10.27kg with package |
| Certificazione & Conformità | ||
| Certificazioni di sicurezza | CE, UL, cUL, RoHS | Compliant with EU Low Voltage Directive 2014/35/EU |
| EMC Standard | IN 55011 Class A | EMC requirement for industrial environment |
| ECCN Code | Unione Europea: Y901, US: 3A999.a | Export control classification code |
- Elenco completo dei modelli della serie (380-480V Three-phase)
| Energia | Modello | Numero d'ordine | Corrente nominale | Dimensioni del telaio |
| 0.37kW | FC-051PK37T4E20H3BXCXXXSXXX | 132F0001 | 1.1UN | M1 |
| 0.75kW | FC-051PK75T4E20H3BXCXXXSXXX | 132F0002 | 2.1UN | M1 |
| 1.5kW | FC-051P1K5T4E20H3BXCXXXSXXX | 132F0003 | 3.7UN | M1 |
| 2.2kW | FC-051P2K2T4E20H3BXCXXXSXXX | 132F0004 | 5.2UN | M1 |
| 3.0kW | FC-051P3K0T4E20H3BXCXXXSXXX | 132F0024 | 7.0UN | M2 |
| 4.0kW | FC-051P4K0T4E20H3BXCXXXSXXX | 132F0025 | 9.3UN | M2 |
| 5.5kW | FC-051P5K5T4E20H3BXCXXXSXXX | 132F0026 | 12.5UN | M3 |
| 7.5kW | FC-051P7K5T4E20H3BXCXXXSXXX | 132F0027 | 17.0UN | M3 |
| 11kW | FC-051P11KT4E20H3BXCXXXSXXX | 132F0059 | 25.0UN | M4 |
| 15kW | FC-051P15KT4E20H3BXCXXXSXXX | 132F0060 | 32.0UN | M5 |
| 18.5kW | FC-051P18KT4E20H3BXCXXXSXXX | 132F0060 | 37.0UN | M5 |
| 22kW | FC-051P22KT4E20H3BXCXXXSXXX | 132F0061 | 45.0UN | M5 |
- Cross-brand Equivalent Model Comparison
| Danfoss FC-051P18KT4E20H3BXCXXXSXXX | Siemens | Schneider | ABB | Replacement Suggestion |
| 18.5kW/37A/380-480V | SINAMICS G120C 6SL3210-1KE22-6UF1 | Altivar 320 ATV320U40N4 | ACS150-03E-04A1-4 | Funzioni simili, communication protocols need matching |
| Modalità di controllo: VVC+/U/f | Controllo vettoriale | Controllo vettoriale | DTC Direct Torque Control | ABB features fastest dynamic response; Schneider offers higher cost performance |
| Built-in brake chopper | External accessory required | Integrato | External accessory required | Danfoss features more flexible configuration |
| RFI Class A1/B | Optional Class A/B | Built-in Class A | Optional Class A/B | Meet industrial EMC standards |
| Without LCP (purchased separately) | Standard BOP-2 | Standard keypad | Standard assistant control panel | Siemens owns friendliest operation interface |
Obsolete Replacement: FC-051 is still mainstream without direct discontinued substitutes. For function upgrade, choose Danfoss FC-301 series with richer functions and support for PROFINET and other advanced communication protocols.
- Ambiente applicativo & Industry Cases
Scenari applicabili
Tifosi & Water Pumps: Sistemi HVAC, water treatment plants, cooling towers, realize 30%-50% energy saving via variable frequency speed regulation
Material Conveying: Trasportatori, montacarichi, macchine per l'imballaggio, achieve smooth start/stop and precise speed control
Cibo & Industria delle bevande: Filling lines, macchine etichettatrici, sterilization equipment, adapt to humid environment with PCB coating protection
Macchinari tessili: Macchine per la filatura, weaving machines, satisfy low-speed high-torque demands
Small Machine Tools: Drilling machines, fresatrici, grinders, realize accurate speed adjustment
Non-recommended Scenarios
Heavy-duty impact loads: Such as crushers and punch presses (FC-302 series is recommended)
Explosion-proof occasions: Special explosion-proof models required (FC-051 has no explosion-proof certification)
Altitude above 1000m: Derating operation needed (1% power reduction per 100m rise)
Ambient temperature over 50°C: Additional cooling measures or derating operation required
Casi applicativi tipici
- Constant Pressure Water Supply System
Adopt FC-051P18KT4 to control 18.5kW water pump with closed-loop control via pressure sensor, realizing 40% risparmio energetico, stabilizing pipeline pressure and extending equipment service life.
- Packaging Production Line
Four sets of FC-051 series inverters including 18.5kW model are applied to control conveyor speed for synchronous operation, lowering product damage rate and greatly reducing downtime frequency.
- Central Air-conditioner Fan System
Applied in shopping mall air conditioner fans to adjust rotating speed automatically by ambient temperature, risparmiando circa 28,000 RMB electricity fee annually per unit and reducing operating noise.
- Conformità del trasporto aereo & Certificazione
Air Freight Regulations
Built-in Capacitor: Equipped with DC bus electrolytic capacitors without lithium batteries, UN38.3 test report is not required
Transport Classification: Non-dangerous goods, deliverable as common electronic products by air
Packaging Requirements
Power off completely with capacitors discharged for more than 5 minuti
Fixed in anti-static package to avoid collision damage
Mark with labels of “Fragile Electronic Equipment” E “This Side Up”
Principali certificazioni
| Codice errore | Fault Description | Possibili cause | Passaggi per la risoluzione dei problemi |
| AL16 | Output Short Circuit | 1. Motor winding short circuit | 1. Cut off power and disconnect UVW motor wiring |
| 2. Damaged motor cable | 2. Test three-phase motor winding resistance balance | ||
| 3. Power module failure | 3. Check cable insulation condition | ||
| 4. Reset and test inverter output under no-load state | |||
| AL10 | Surriscaldamento del motore | 1. Overloaded operation | 1. Confirm actual load within rated range |
| 2. Poor motor heat dissipation | 2. Clean motor heat sink | ||
| 3. Temperature sensor failure | 3. Inspect PT100 and thermistor connection | ||
| AL51 | DC Bus Undervoltage | 1. Low input voltage | 1. Measure input voltage (intervallo normale: 342-528V) |
| 2. Phase loss of power supply | 2. Check three-phase power balance | ||
| 3. Rectifier bridge failure | 3. Detect rectifier module output | ||
| AL71 | Inverter Overheating | 1. Temperatura ambiente eccessivamente elevata | 1. Ensure ambient temperature ≤40°C |
| 2. Cooling fan malfunction | 2. Check fan running status | ||
| 3. Radiator blockage | 3. Remove dust and sundries on radiator | ||
| AL52 | Perdita di fase in ingresso | 1. Power supply phase missing | 1. Measure three-phase input voltage |
| 2. Loose wiring terminals | 2. Fasten terminal wiring | ||
| 3. Faulty input contactor | 3. Test contactor switching performance |
- Difetti comuni & Guida alla risoluzione dei problemi
| Nome dell'accessorio | Modello | Funzione | Necessity |
| Local Control Panel | LCP 12 | On-site parameter setting and monitoring | Raccomandato (not standard equipped) |
| Resistenza freno | MCE 101-0300 | Dissipate regenerative energy and prevent overvoltage | Mandatory for models with code B |
| Modulo di comunicazione | FC CAN/Profibus | Realize industrial network connection | Optional on demand |
| Input Filter | H3 Upgrade Kit | Upgrade EMC performance to Class B | Recommended for electromagnetic sensitive occasions |
| Copertura protettiva | FC-051-IP40 | Upgrade protection class to IP40 | Recommended for dusty working sites |
- Regole di selezione & Quick Tips
- Abbinamento di potenza: Inverter rated current ≥ 1.1 times motor rated current to cope with starting impact
- Voltage Confirmation: Input voltage shall stay within 380-480V with fluctuation ≤±10%
- Brake Configuration: Models with code B have built-in brake choppers, external brake resistors required (power ≥ 30% of motor power)
- Dissipazione del calore: Keep ventilation space over 10cm for M5 frame; declassare 10% power per 5°C rise above 40°C
- Communication Expansion: Additional Modbus/Profibus modules need separate purchase for network communication
- Recommended Key Accessories
| Nome dell'accessorio | Modello | Funzione | Necessity |
| Local Control Panel | LCP 12 | On-site parameter setting and monitoring | Raccomandato (not standard equipped) |
| Resistenza freno | MCE 101-0300 | Dissipate regenerative energy and prevent overvoltage | Mandatory for models with code B |
| Modulo di comunicazione | FC CAN/Profibus | Realize industrial network connection | Optional on demand |
| Input Filter | H3 Upgrade Kit | Upgrade EMC performance to Class B | Recommended for electromagnetic sensitive occasions |
| Copertura protettiva | FC-051-IP40 | Upgrade protection class to IP40 | Recommended for dusty working sites |
Full Analysis on Application Cases of Danfoss FC-051P18KT4E20H3BXCXXXSXXX (18.5kW) Invertitore
- Overview of Core Application Fields
This 18.5kW/37A/380-480V inverter with built-in brake chopper and coated PCB board is widely applied relying on VVC+ vector control, IP20 protection and high cost performance:
HVAC industry: Central air conditioner fans, cooling towers, pompe dell'acqua
Trattamento dell'acqua: Constant pressure water supply, aeration tanks, sludge return pumps
Movimentazione dei materiali: Heavy-duty conveyors, ascensori, logistics sorting lines
Food industry: Filling machines, sterilization equipment, macchine confezionatrici
Textile industry: Macchine per la filatura, weaving machines, macchine per l'impostazione
Building material machinery: Miscelatori, light-duty crushers
- Detailed Introduction of Five Typical Application Cases
Caso 1: Constant Pressure Water Supply for Residential Communities
Original power frequency water supply system suffered from severe pressure fluctuation, high power consumption and frequent pump startup-stop. After adopting FC-051 constant pressure frequency conversion control system with pressure sensor feedback, it realizes sleep & wake-up automatic operation, cutting daily power consumption greatly, stabilizing water supply pressure and prolonging pump service life obviously.
Caso 2: Central Air-conditioner Fan System in Shopping Malls
Replace fixed-speed fan operation with variable frequency temperature closed-loop control, set minimum frequency to avoid fan surging, realize intelligent speed regulation according to indoor temperature, save massive electricity cost annually and lower operating noise effectively.
Caso 3: Food Packaging Production Line Multi-machine Linkage
Adopt multi-speed regulation and synchronous follow-up control to match operating speed of different conveying equipment. Built-in brake chopper achieves rapid stop, reduces material stacking and product damage rate, and improves overall production efficiency. Coated PCB adapts to humid and dusty food workshop environment.
Caso 4: Spinning Machine Control System in Textile Mill
Replace traditional slip speed regulating motor with VVC+ vector control inverter, realize high torque output at low speed, broaden speed regulation range, promote motor operating efficiency, reduce yarn breakage rate and cut daily maintenance frequency.
Caso 5: Aeration System for Sewage Treatment Plant
Match dissolved oxygen sensor to build PID closed-loop control system, automatically adjust fan air volume to keep dissolved oxygen content in optimal range, stabilize sewage treatment effect, reduce invalid energy consumption and lower equipment abrasion.
- Application Scene Matching Table
| Application Scene | Matching Level | Vantaggi fondamentali | Note |
| Constant pressure water supply / circulating pump | ★★★★★ | PI regulation + intelligent logic, prominent energy-saving effect | Equipped with pressure sensor and brake resistor suggested |
| Central air conditioner / cooling tower fan | ★★★★★ | Temperature closed-loop control, low noise and energy saving | Surge prevention setting required, derate at high altitude |
| Heavy conveyor / hoist | ★★★★☆ | Stable start-stop, strong overload resistance | Confirm actual load type in advance |
| Cibo & beverage production line | ★★★★☆ | Multi-speed control, high synchronization precision | Coated PCB for humid environment adaptation |
| Textile printing & dyeing machinery | ★★★★☆ | Low-speed high torque, wide speed range | Add anti-interference measures |
| Sewage treatment aeration system | ★★★★☆ | Precise PID control, energy consumption optimization | Regular radiator cleaning required |
| Heavy impact load equipment | ★☆☆☆☆ | – | Choose FC-302 series instead |
| Explosion-proof working environment | ★☆☆☆☆ | – | Special explosion-proof inverters required |
| Altitude over 2000m | ★☆☆☆☆ | – | Not recommended due to large power derating amplitude |
- Key Selection Points for Practical Application
- Match inverter current reasonably according to actual motor load
- Select models with built-in brake units for frequent start-stop and fast stop working conditions
- Choose U/f control mode for fan & pump loads, VVC+ vector control for transmission and processing equipment
- Prioritize coated PCB models for humid, dusty and corrosive sites
- Select matched external accessories and control panels according to on-site debugging and remote control demands