(With Analog Pointer Display) Full Order Code: PG-004-REA01-MFRKG/US/ /P Application: Cibo, beverage and pharmaceutical hygienic processes. Flush diaphragm with no dead volume, suitable for CIP/SIP cleaning. Integrates display, pressure transmission and pressure switch in one unit. ✅ Main Measuring Range (Relative Pressure) Campo di misura: -1 … 4 sbarra (-14.5 ~ 58 psi) Overload pressure: 6.4 ...

  • Dettagli del prodotto

(With Analog Pointer Display)

Full Order Code: PG-004-REA01-MFRKG/US/ /P

Applicazione: Cibo, beverage and pharmaceutical hygienic processes. Flush diaphragm with no dead volume, suitable for CIP/SIP cleaning. Integrates display, pressure transmission and pressure switch in one unit.

✅ Main Measuring Range (Relative Pressure)

Campo di misura: -1 … 4 sbarra (-14.5 ~ 58 psi)

Overload pressure: 6.4 sbarra

Static withstand pressure: 30 sbarra

Pressione di scoppio: 100 sbarra

✅ Process Connection

Filo: G1 external thread with Aseptoflex Vario hygienic connection (IFM exclusive hygienic interface)

Wetted materials: 316l (1.4435) acciaio inossidabile, 99.9% alumina ceramic, FKM, PTFE; Surface roughness Ra<0.4 μm, no stagnant dead zones. Ideal for viscous media, particle-containing liquids, slurries, beer, milk and other fluids.

✅ Electrical & Uscite

Tensione di alimentazione: 18~32 VDC, protezione da inversione di polarità

Uscite: 1 programmable PNP/NPN switching output + 1 configurable 4…20mA analog output (reversible to 20…4mA); IO-Link communication available

Elettrico connector: M12 A-coded, gold-plated contacts

Massimo. load current for switching output: 250 mA

✅ Temperature, Protezione & Precisione

Temperatura media: -25 … 125 ℃; short-term peak up to 145℃ (≤1 hour for SIP sterilization)

Classe di protezione: IP68 / IP69K, resistant to high-pressure jet cleaning

Basic accuracy: 0.2% FS; extended display range: 1.5% FS

Vita utile meccanica: ≥100 million pressure cycles

Display: Rotatable housing, electronic analog pointer + LED bar graph for long-distance visibility. Optical touch keys for parameter setting, switch point adjustment, range scaling and peak value hold/reset.

✅ Model Differentiation (Critical for Procurement)

PG2795: G1 Aseptoflex Vario thread, 1 interruttore + uscita analogica, analog pointer display

PI2795: Same -1~4bar range, 2 switching outputs + 4-digit digital screen (no analog pointer)

PG2895: Stessa gamma, G1 conical seal (non-Aseptoflex) versione

✅ Typical Applications

Dairy, beer, fruit juice, sauce, pharmaceutical preparation tanks, static hydrostatic level measurement in hygienic pipelines (vacuum/positive pressure monitoring), CIP circuit pressure control, pressure measurement for viscous media.

✅ Key Requirements for Domestic Alternative Models (for Tender Replacement)

  1. Hygienic flush diaphragm, G1 Aseptoflex Vario or compatible hygienic fitting, Ra ≤ 0,4 μm
  2. Measuring range -1~4 bar, withstand short-term SIP 145℃, Protezione IP69K
  3. 4-20mA analog + 1 PNP/NPN switch output; IO-Link opzionale
  4. Wetted part 316L stainless steel, FDA / 3A hygienic certification

IFM PG2795 | M12 4-pin A-coded Pin Assignment

PG2795: Pin4 = OUT1 (Interruttore / IO-Link C/Q); Pin2 = OUT2 (4…20mA analog signal)

M12 PinSegnaleDescrizione
Perno1L+ / 24VDC+Potenza positiva, 18~32VDC
Perno2USCITA24-20Uscita analogica mA (configurable reverse 20-4mA)
Perno3l- / 0VPotenza negativa, GND
Perno4USCITA1 / C/QProgrammable PNP/NPN switch; IO‑Link mode: communication line

Operating Mode Notes:

SIO Mode (Operazione standard): Pin4 = switching output; Pin2 = 4-20mA analog signal

IO-Link Mode: Pin4 serves as C/Q communication line. Switch status and analog value are transmitted via IO-Link telegrams; the hardware analog output (Perno2) remains functional

A-coded connector; 1 PNP/NPN programmable switch + 4-20mA analog. No IO-Link function (IO-Link version belongs to PI27 series)

  1. Full PG27 Series Model List (Active Models with Measuring Ranges)

1) Main PG279x Models (G1 Aseptoflex Thread)

ModelloCampo di misura (sbarra)Full Order CodeOsservazioni
PG2793-1 … 25PG-025-REA01-MFRKG/US/ /PWide range (vuoto + alta pressione); phase-out underwayifm
PG2794-1 … 10PG-010-REA01-MFRKG/US/ /PTank pressure standard rangeifm
PG2795 (Il tuo modello)-1 … 4PG-004-REA01-MFRKG/US/ /PMost popular vacuum + low positive pressure rangeifm
PG2796-0.124 … 2.5PG-2,5-REA01-MFRKG/US/ /PLow pressure rangeifm
PG2797-0.05 … 1PG-001-REA01-MFRKG/US/ /PMicro-pressure measurementifm
PG27980 … 0.25PG-000,25-REA01-MFRKG/US/ /PUltra-low micro-pressureifm
PG2799-1 … 1PG-001(-1)-REA01-MFRKG/US/ /PVuoto + slight positive pressureifm
PG27890 … 0.1PG-000,1-REA01-MFRKG/US/ /PUltra-fine micro-pressureifm

2) PG2736 / PG2738 (Same Structure, Low Range)

ModelloCampo di misuraFull Order Code
PG2736-0.124…2.5 barPG-2,5BREA01-MFRKG/US/ /P
PG2738-0.0124…0.25 barPG-,25BREA01-MFRKG/US/ /P

III. PG28 Equivalent Models (Tri-Clamp Version for Direct Replacement)

PG27 = G1 external thread; PG28 = hygienic tri-clamp fitting, ranges fully matched:

PG2793 ↔ PG2893

PG2794 ↔ PG2894

PG2795 ↔ PG2895

PG2796 ↔ PG2896

PG2797 ↔ PG2897

PG2798 ↔ PG2898

PG2799 ↔ PG2899

PG2789 ↔ PG2889

  1. Ripartizione della codifica del modello (PG2795 Decoding)
  2. PG = Pressure transmitter with analog gauge display
  3. 27 = G1 external flush hygienic thread; 28 = tri-clamp connection
  4. 95 = range code: 95 = -1…4 bar
  5. Suffix REA01-MFRKG: Aseptoflex seal, flush diaphragm, Connettore M12 a 4 pin
  6. Distinzione critica (Avoid Wrong Order)

PG27: Only switch + 4-20mA, NO IO-Link; analog pointer + numeric display

PI27: Same outline, with IO-Link + dual switching outputs + uscita analogica, pure digital 4-segment screen (no mechanical pointer)

  1. Phase-out Notice

PG2793 is gradually discontinued; modello sostitutivo: PG1703. All other models (PG2794/95/96/97/98/99) remain in full production.