The Omron G3PA series single-phase solid state relay (RSS) with integrated heat sink, zero-crossing turn-on, Montaggio su guida DIN, directly driven by PLC DC signals. Widely used for non-contact switching control of heating elements, fans and lamp loads. Nota importante: Questo modello è fuori produzione. Only stock units are available or alternative models should be selected. Modello ...

  • Dettagli del prodotto

IL Omron G3PA series single-phase solid state relay (RSS) with integrated heat sink, zero-crossing turn-on, Montaggio su guida DIN, directly driven by PLC DC signals. Widely used for non-contact switching control of heating elements, fans and lamp loads.

Nota importante: Questo modello è fuori produzione. Only stock units are available or alternative models should be selected.

  1. Definizione del codice modello

G3PA: Nome della serie, solid state relay with integrated heat sink

2: Monofase, AC24~240V output specification

40: Rated load current 40A

B: Built-in heat sink

VD: DC5~24V DC input control, opto-triac isolation, zero-crossing turn-on

  1. Specifiche elettriche principali

✅ Input Side (Control Terminals +A1, -A2)

Tensione di controllo: DC5~24V, operating range DC4~30V

Maximum input current: 7mA (directly drivable by PLC output point)

Operating voltage ≤DC4V; Reset voltage ≥DC1V

Isolamento: Opto-triac isolation

✅ Output Side (Terminali di carico 1, 2)

Rated load voltage: AC24~240V, operating range AC19~264V (50/60Hz)

Rated load current: 40A @40℃; derate to 36A for dense side-by-side mounting

Surge withstand current: 440UN (60Hz, 1 ciclo)

I²t: 1260 A²s

On-state voltage drop: ≤1.6V RMS

Switching characteristic: Zero-cross turn-on, reduces switching surge

Operare / tempo di rilascio: Within half cycle of load power supply +1ms

✅ Environmental & Meccanico

Temperatura operativa: -30℃ ~ +80 ℃ (nessuna condensa)

Montaggio: DIN rail or screw mounting; screw type terminals

Dimensioni: W47 × H100 × D100 mm

Dielectric strength between input and output: AC4000V

  1. Scenari applicativi tipici

Controllo della temperatura: Heating tubes, ceramic heaters, infrared heating (più comune)

Illuminazione: High power lamp banks, halogen lamps

Motori: Small single-phase fans (resistivo / weakly inductive load preferred)

Nota: Inductive loads and loads with large starting inrush current require additional varistor and RC snubber protection.

  1. Linee guida per il cablaggio
  2. +A1, -A2: DC control signal, good polarity tolerance. It is recommended to connect PLC positive output to A1.
  3. Terminali 1, 2: Connected in series to AC load circuit, L/N non-polarity.
  4. Circuito soppressore RC + varistor connected in parallel at output terminals for inductive loads.
  5. Derate current and reserve heat dissipation clearance when multiple SSRs are installed side by side on DIN rail.
  6. Replacement Models for Discontinued Product
  7. Upward replacement within same series: G3PA-260B-VD (60UN, DC5~24V input). Same pin layout with higher capacity.
  8. New generation alternative: G3PE series G3PE-245B, 45A DC control, Montaggio su guida DIN, sostituzione diretta.
  9. Domestic compatible SSR: 40A solid state relay, DC5-24V input, AC240V, zero-cross type with integrated heat sink.
  10. Risoluzione dei problemi comuni
  11. Input LED does not light: Check PLC output voltage and broken wiring; insufficient input current to drive SSR.
  12. LED lights but load does not turn on: Loose output terminals, carico rotto; internal triac damage.
  13. Load remains energized after control signal removed: SSR short-circuit failure (common for heating loads), usually caused by overheating or surge breakdown.
  14. Frequent false triggering: Control cable runs in parallel with power cable causing interference; connect 1000pF anti-interference capacitor at input side.
  15. Note sulla selezione
  16. Carichi resistivi: Derate to 0.7 times rated current for selection.
  17. Heating loads have low cold resistance with large starting inrush current, sufficient current margin is required.
  18. Further derate when ambient temperature >40℃ or densely mounted.
  19. Solid state relay has no mechanical contacts, cannot serve as safety disconnect switch. Circuit breaker must be fitted on main circuit.

OMRON G3PA-240B-VD (40A DC to AC Zero-cross SSR) Casi applicativi tipici

Product Recap: Integrated heat sink, Montaggio su guida DIN, DC5~24V input, AC24~240V 40A, zero-cross turn-on. Directly driven by PLC, mainly suitable for resistive loads. RC+MOV snubber required for inductive loads.

Caso 1: Temperature Control System – Industrial Heating Tube Control (Il più popolare)

Applicazione

Forni, hot presses, plastic dryers, mold temperature machines, food baking lines, single-phase 220V heating tubes, max power ~8kW (220V×40A), PID power regulation by PLC + regolatore di temperatura.

Configurazione del sistema

  1. Controllare: Transistor output DC24V from temperature controller / PLC connected to A1/A2 of G3PA; zero-cross switching reduces grid harmonic distortion.
  2. Circuito principale: AC220L → SSR terminal 1; terminale 2 → heating tube → N.
  3. Protezione: 3P circuit breaker + fast fuse at upstream; thermocouple over-temperature protection is recommended for heating tubes.
  4. Snubber: RC optional for resistive loads; 470V varistor is recommended for high power applications to absorb grid surge.

Derating Recommendation

Continuous long-term operation: Load current controlled within 28A (0.7×rating); reduce to 24A for side-by-side multi-unit installation.

Vantaggi

Contactless operation, no contact erosion even under frequent switching (several times per second), higher PID temperature control accuracy.

Insidia comune

Heating tubes have large cold-state inrush current. Continuous full-current operation tends to break down SSR; do not treat rated 40A as continuous operating current.

Caso 2: High Power Halogen / Infrared Lamp Bank Control

Applicazione

UV curing lamps, infrared heating lamps, industrial inspection light sources, infrared radiation panels for drying lines, 220V AC lamp banks.

Configurazione del sistema

PLC DC24V output drives SSR; lamp load connected in parallel to SSR output terminals.

Halogen lamp has extremely low cold resistance, inrush current at switch-on can reach 8~10 times rated current.

Precauzioni

  1. Zero-cross G3PA is well suited for lamp loads, turn-on at voltage zero point to reduce inrush.
  2. Heavy derating is mandatory: lamp load at 0.4~0.5 times SSR rating; load ≤20A for this 40A SSR.
  3. NTC surge limiting thermistor in series is recommended.

Vantaggi

Commutazione silenziosa, nessun arco elettrico in caso di accensioni/spegnimenti frequenti, adatto per sorgenti luminose di linee di produzione automatizzate.

Caso 3: Tifosi / Piccoli motori monofase (Carico induttivo)

Applicazione

Ventilatori abbinati al riscaldamento del condotto dell'aria, ventole di raffreddamento ad alta potenza dell'armadio, piccoli ventilatori di trasporto monofase per il controllo continuo dell'avvio-arresto.

Questo è un carico induttivo, Ammortizzatore RC + È necessario installare il varistore MOV (100Varistore Ω/2W +0,1μF/400VAC +470V).

Sistema

Il PLC controlla l'SSR per avviare/arrestare la ventola; interruttore montato a monte del SSR.

Limitazione

Non adatto per frequenti rotazioni avanti/indietro del motore; non applicabile per motori ad alta potenza con notevole picco di avviamento.

La forza elettromotrice generata allo spegnimento del motore può facilmente danneggiare l'SSR, Lo smorzatore RC è essenziale.

Caso 4: Gruppo di elettrovalvole, Azionamento bobina contattore CA (Piccolo carico induttivo)

Applicazione

Attrezzature per l'imballaggio, linee di produzione pneumatiche, più bobine parallele AC220V controllate centralmente da PLC.

Configurazione del sistema

L'uscita SSR aziona più bobine solenoidi AC220V parallele; RC+MOV collegati in parallelo ai terminali SSR.

Note

La bobina del solenoide è un'induttanza, genera picchi di alta tensione allo spegnimento; la corrente di carico totale non può superare i 40 A.

Potrebbero verificarsi lievi vibrazioni del solenoide dopo lo spegnimento dell'SSR a causa della corrente di dispersione dell'RC. Soluzione: collegare una resistenza di dispersione da 10 kΩ/5 W ai ​​terminali di carico.

Caso 5: 220Rulli motorizzati V AC per linee di trasporto / Piccole attrezzature di trasporto

Applicazione

Linee di smistamento logistico, linee di trasporto per il confezionamento, comando start-stop dei rulli motorizzati monofase 220V.

Punti chiave

Soppressore RC+MOV obbligatorio per carico induttivo del motore; non adatto per jogging frequente con forti impatti, applicabile per il funzionamento a lungo termine con intervallo di avvio-arresto a lungo.

Caso 6: Circuito di riscaldamento della camera di prova ambientale

Applicazione

Temperatura costante & camera umida, camera di prova di invecchiamento, resistive heating circuit with continuous PID power regulation.

Configurazione del sistema

PID DC24V output from temperature controller drives G3PA; multi-section heating zone control with multiple G3PA mounted side by side on DIN rail.

Note chiave

Derate current and reserve heat dissipation clearance for side-by-side installation; ambient temperature around SSR must not exceed 60℃.

Load Selection Summary Table

Tipo di caricoRecommended DeratingRC+MOVOsservazioni
Resistive heating tube0.7×ratingOpzionale (MOV recommended)Most compatible, ampiamente utilizzato
Halogen / Infrared lamp0.4~0.5×ratingRaccomandatoExtreme cold inrush current
Single-phase fan, small motor (induttivo)0.6×ratingObbligatorioHigh risk of back EMF breakdown at turn-off
AC220V solenoid coil0.6×ratingObbligatorioLeakage current may cause minor false actuation

General Usage Prohibitions for G3PA-240B-VD

  1. ❌ Not for large air compressors, high-power single-phase motors (excessive starting surge)
  2. ❌ Cannot act as safety disconnect switch, interruttore indipendente richiesto per il circuito principale
  3. ❌ Non adatto a carichi induttivi ad alta tensione e ad alta frequenza; Rischio di guasto da cortocircuito del triac (SSR bloccato, carico alimentato continuamente, rischio di incendio da temperatura eccessiva nei sistemi di controllo della temperatura)
  4. ❌ Ulteriore declassamento della corrente richiesto quando la temperatura ambiente>60℃

Elenco guasti G3PA-240B-VD per scenario applicativo

Modello: Omron G3PA-240B-VD, 40Un SSR a passaggio zero con ingresso CC; principali modalità di guasto: cortocircuito permanente in uscita (più pericoloso), mancata accensione, falsi inneschi intermittenti.

Precauzione: Se l'SSR fallisce, cortocircuitato, il carico rimane energizzato continuamente. Il rischio di incendio da temperatura eccessiva è elevato per gli impianti di riscaldamento. Sul circuito principale deve essere installata una protezione indipendente da sovratemperatura.

Caso 1: Tubo di riscaldamento / Forno, Macchina per la temperatura dello stampo (Carico resistivo, Più comune)

Colpa1: L'SSR va in cortocircuito dopo un periodo di funzionamento, il riscaldamento non si ferma mai

Sintomo: PLC control signal removed, no input at A1/A2, heating tube remains heated; SSR housing very hot.

Causa ultima:

1) Long-time full current operation without 0.7 declassamento; insufficient heat dissipation with side-by-side mounting.

2) Aging heating tube with partial short circuit, surge current breaks triac.

3) Grid voltage spike without varistor protection.

Rimedio: Control load current ≤28A; install 470V varistor; periodically test insulation of heating tube; add independent over-temperature thermostat for hard cut-off.

Fault2: Large temperature fluctuation under PID control, intermittent heating

Sintomo: Temperature controller output normal, heating cuts in and out randomly.

Causa ultima:

1) Insufficient output current from PLC, voltage drop on cable.

2) Loose SSR terminals, contact resistance generates heat.

3) Oxidized wiring of heating tube, scarso contatto.

Rimedio: Stringere i terminali (torque 0.8~1.0N·m); check driving capacity of PLC transistor output; replace aged heating tube.

Colpa3: SSR indicator LED on, but no heating

Causa ultima: Broken output circuit, burnt heating tube; open-circuit damage of internal triac.

Rimedio: Measure resistance of heating tube after power-off; measure AC voltage across SSR output terminals.

Caso 2: Halogen / Infrared Lamp Bank

Colpa1: SSR damaged immediately upon lamp switch-on

Sintomo: SSR burns out right after lamp activation even if average current is low.

Causa ultima: Extremely low cold resistance of halogen lamp, inrush current reaches 8~10 times rated; zero-cross turn-on still cannot eliminate huge surge without derating.

Rimedio: Limit load current to 0.4~0.5×SSR rating; fit NTC surge suppression thermistor in lamp circuit; prefer lamp-specific SSR.

Fault2: Lamp flickering

Causa ultima: Fluctuating supply voltage; lamp aging; internal component aging of SSR.

Rimedio: Replace aged lamps; verify power supply stability.

Caso 3: Single-phase Fan, Small Motor (Carico induttivo)

Colpa1: SSR breaks down every time fan stops

Sintomo: Fan runs normally, L'SSR fallisce quando il segnale di controllo si spegne.

Causa ultima: L'induttanza dell'avvolgimento del motore genera un'elevata forza elettromotrice allo spegnimento; RC+MOV non montato.

Rimedio: Installare lo smorzatore RC (100Ω/2W +0,1μF/400VAC in serie) +470Varistore V, collegare direttamente vicino ai terminali SSR.

Fault2: La ventola ruota lentamente dopo lo spegnimento dell'SSR

Sintomo: La ventola non si ferma completamente dopo la rimozione del segnale PLC, rotazione a bassa velocità.

Causa ultima: Corrente di dispersione introdotta dallo snubber RC, debole tensione indotta sugli avvolgimenti del motore.

Rimedio: Montare una resistenza di dispersione da 10 kΩ/5 W sui terminali del motore; oppure utilizzare un contattore meccanico per l'interruzione completa.

Caso 4: Banco di bobine solenoidi AC220V (Carico induttivo)

Colpa1: Il solenoide si inserisce in modo casuale (falso innesco)

Sintomo: Il solenoide occasionalmente vibra o si attiva senza segnale di uscita del PLC.

Causa ultima: Corrente di dispersione RC; interferenze elettromagnetiche quando il cavo di controllo corre parallelo al cavo di alimentazione; cavo di controllo eccessivamente lungo.

Rimedio: Montare un resistore di dispersione da 10 kΩ/5 W sui terminali di carico; instradamento separato per i cavi di controllo e di alimentazione; montare un condensatore anti-interferenza da 1000pF sul lato ingresso.

Fault2: SSR danneggiato dopo più cicli di commutazione

Causa ultima: Picco di alta tensione derivante dallo spegnimento della bobina senza protezione RC+MOV.

Rimedio: Installa RC+MOV; non collegare in parallelo un numero eccessivo di solenoidi, declassare la corrente totale a 0,6×nominale.

Caso 5: Rullo motorizzato del trasportatore

Colpa1: Avvio-arresto instabile del rullo, occasionale errore di avvio

Sintomo: Il rullo a volte non riesce ad avviarsi anche quando il segnale di controllo viene inviato all'SSR.

Causa ultima: Grande aumento di avviamento del motore; margine SSR insufficiente; voltage drop on cable.

Rimedio: Ridurre la capacità di carico; verificare la sezione del cavo di alimentazione; RC+MOV obbligatorio per carico induttivo.

Fault2: Grave surriscaldamento dell'SSR

Causa ultima: Funzionamento a corrente pesante per lungo tempo; scarsa dissipazione del calore per più SSR montati fianco a fianco su guida DIN.

Rimedio: Aumentare lo spazio di montaggio tra le unità SSR; ridurre la corrente di carico; aggiungere una ventola di raffreddamento ausiliaria, se necessario.

Difetti comuni generali (Applicabile a tutti gli scenari)

  1. Il LED indicatore di ingresso su A1/A2 non si accende

Sequenza di risoluzione dei problemi:

1) Controllare l'uscita del PLC, confermare la presenza di 24 V CC.

2) Cavo di controllo rotto, polarità invertita (tollerato in una certa misura, L'inversione di polarità a lungo termine danneggia il LED di ingresso).

3) Circuito di ingresso SSR bruciato.

  1. LED di ingresso normale, nessuna azione in uscita

Risoluzione dei problemi: Alimentazione principale disponibile; terminali di uscita allentati; open-circuit damage of internal triac.

  1. Guasto casuale dell'SSR a temperatura ambiente elevata

Causa ultima: Temperatura ambiente>60 ℃, la dissipazione del calore peggiora, deriva caratteristica del dispositivo.

Rimedio: Migliorare la ventilazione dell'armadio; declassare ulteriormente la corrente; montare l'SSR lontano da componenti che generano calore.

  1. Falsa attivazione casuale dell'SSR causata da interferenze

Sintomo: L'SSR si accende/spegne in modo irregolare durante il funzionamento dell'apparecchiatura.

Contromisure:

1) Canalina portacavi separata per segnale di controllo e cavo di alimentazione, evitare lunghi percorsi paralleli.

2) Montare il relè di isolamento sul lato di uscita del PLC.

3) Collegare il condensatore ceramico ad alta tensione da 1000pF sul lato ingresso.

Procedura rapida di diagnosi dei guasti (Per la messa in servizio in loco)

  1. Scollegare l'alimentazione principale CA, mantenere accesa l'alimentazione di controllo DC24V, verificare se il LED di ingresso SSR segue il segnale del PLC.
  2. Spegnimento, misurare la resistenza sui terminali di uscita SSR:

Stato normale (nessun segnale in ingresso): Alta resistenza, Livello megaohm.

Resistenza prossima allo stato di conduzione senza ingresso: SSR in cortocircuito, NON energizzare!

  1. Accensione con carico, measure AC voltage across SSR output terminals:

Con segnale ON: Caduta di tensione sui SSR ≤1,6 V.

Con segnale OFF: Tensione attraverso SSR vicina a AC220V.

  1. Controllare la temperatura dell'alloggiamento dell'SSR; migliorare il declassamento o la dissipazione del calore se la temperatura supera i 70 ℃.

Norme di sicurezza

  1. Il guasto da cortocircuito è la tipica modalità di guasto di questo SSR. Per le applicazioni di riscaldamento è necessario montare una protezione meccanica indipendente da sovratemperatura; non fare affidamento solo su PLC e SSR.
  2. Non eseguire test a lungo termine senza RC+MOV per alcun carico induttivo.
  3. Gli SSR non devono essere utilizzati come interruttori di isolamento di sicurezza; l'interruttore principale deve essere aperto per la manutenzione dell'apparecchiatura.