Parker DSH101NR Threaded Cartridge Valve

DSH101NR DSH101: Series – 2-way poppet type solenoid cartridge valve, standard cavity C10-2 N = Normally Open: Open when de-energized, closed when energized R = Reverse free flow Function: Flow permitted 2→1 when open; closed upon energization; free reverse flow 1→2 (integral check function) Main Technical Specifications Item Parameter Valve Type 2-position 2-way poppet solenoid ...

  • Dettagli del prodotto

DSH101NR

DSH101: Series – 2-way poppet type solenoid cartridge valve, standard cavity C10-2

N = Normally Open: Open when de-energized, closed when energized

R = Reverse free flow

Funzione: Flow permitted 2→1 when open; closed upon energization; free reverse flow 1→2 (integral check function)

  1. Principali Specifiche Tecniche
ArticoloParametro
Valve Type2-position 2-way poppet solenoid cartridge valve
Mounting CavityStandard C10-2 cavity
Pressione operativa massima350 sbarra (5000 psi)
Portata nominale60 l/min (15 GPM)
Closed Leakageca. 0.33 cc/min (5 drops/min, 32cSt hydraulic oil)
Tempo di rispostaChiusura (energizzato): ≈70 ms; Apertura (de-energized): ≈35 ms
Materiale del corpo valvolaAll steel, moving components hardened
Supporti compatibiliMineral oil, synthetic hydraulic fluid; Viscosity range: 6~420 cSt
Filtration RequirementISO 4406 18/16/13 or superior
Sigillo standardPU D-ring; Optional NBR, FKM
Temperatura operativaPU seal: -37℃~+93℃
Installation TorqueCartridge: 69~75 N·m; Solenoid locking nut: 7~10 N·m
Pesoca. 0.2 kg
  1. Logica operativa
  2. Solenoid de-energized (stato normale): Valve open → Port 2 ↔ Port 1 connected
  3. Solenoid energized: Solenoid actuates poppet to close → Flow 2→1 blocked; Free flow 1→2 remains available

Applicazioni tipiche: Single-acting cylinder pressure relief, load holding, lowering cut-off, accumulator unloading circuits

  1. Common Suffix Options (Esempi di modelli completi)

DSH101NR24: 24VDC coil (più comune)

DSH101NR12: 12VDC coil

DSH101NRMS: With manual override button

DSH101NRTN: Deutsch DT04 connector

DSH101NREVS: Deutsch EV series connector

  1. Quick Series Comparison (Guida alla selezione)

DSH101C / CR: Normalmente chiuso (NC)

DSH101N / NR: Normalmente aperto (NO)

Suffix without R: Restricted reverse flow; Suffix R = Free reverse flow (NR/CR)

  1. Domestic Equivalent Reference

Interchangeable C10-2 cavity 2-way solenoid poppet valve with NO + free reverse flow:

HydraForce SV10-21, Vickers, IMMERSIONE, Jialang equivalent cartridge valves.

Su richiesta, Posso fornire:

  1. Text dimension drawing for C10-2 manifold cavity
  2. Typical circuit drawing (single-acting cylinder lowering control)
  3. Excerpts from original manufacturer datasheet

Application Scenarios of Parker DSH101NR

Key function recap for selection reference

DSH101NR: Normalmente aperto + Reverse Free Flow

Diseccitato: Passage 2→1 open; Eccitato: 2→1 blocked; permanent free flow 1→2 (built-in check valve feature)

Poppet construction provides low closed leakage; C10-2 mounting cavity, massimo 350 sbarra, rated flow 60 l/min.

  1. Mobile Hydraulics (Campo di applicazione primario)

1.1 Single-Acting Cylinder Lifting & Load Lowering Circuit (Uso tipico)

Outrigger cylinders & telescopic single-acting cylinders on aerial work platforms

Tipper truck, sanitation equipment lift cylinders

Material clamping & compression single-acting hydraulic cylinders for construction machinery

Circuit Operation Logic:

De-energized state: Cylinder cap side connected to tank, cylinder lowers under load weight

Energized state: Tank path blocked, cylinder locked for load holding

During lifting, pressure oil flows freely 1→2 (Suffix R free reverse flow supplies lifting flow, no separate check valve required)

✅Vantaggio: Single valve realizes lowering on/off control + lifting check function, simplifies manifold circuit layout.

1.2 Accumulator Safety Unloading / Pressure Relief Circuit

Accumulator pressure holding systems:

Machine shutdown / emergency condition: Solenoid de-energized, accumulator pressure relieved via 2→1

Funzionamento normale: Solenoid energized, accumulator circuit sealed to maintain pressure

System charging: Fluid flows freely 1→2 into accumulator

Ampiamente usato: Mobile hydraulic clamps, hydraulic breaker accumulator circuits.

1.3 Brake Drain Control for Unidirectional Hydraulic Motors

Controls motor backpressure line for unidirectional rotary hydraulic motors:

Energized to block backpressure for braking; de-energized to open circuit and allow motor rotation; supply oil passes freely through 1→2.

  1. Industrial Hydraulic Power Units

2.1 Hydraulic Clamps & Press Equipment – Single-Acting Clamp Cylinders

Clamp extension: Pressure oil flows freely 1→2

Clamp retraction: Primavera / load weight retracts cylinder when valve de-energized to open tank line

Standby during production: Solenoid energized to block return line and maintain clamping force; low poppet leakage minimizes pressure decay.

2.2 Pressure Chamber Relief & Safety Dump Valve

Mold hydraulics, hydraulic test benches:

Energized to seal high-pressure chamber during operation; de-energized to automatically depressurize chamber after process completion or safety trigger.

2.3 Circuit Selector & Pump Bypass Unloading Circuit

Pump bypass unloading: Normalmente aperto (de-energized) for direct pump unloading; energized to cut unloading path and build system pressure.

  1. Condizioni di lavoro inadeguate (Insidie ​​della selezione)
  2. Bi-directional locking for double-acting cylinders ❌

Only blocks flow 2→1; path 1→2 is permanently open, cannot seal both directions. For bi-directional pressure holding, select DSH101CR or bi-directional poppet valves.

  1. Application requiring load holding after power loss, relief on energization ❌

DSH101NR: De-energized open, energized closed. If load must remain locked when power fails, select DSH101CR (Normalmente chiuso, free reverse flow).

  1. Continuous steady flow exceeding 60 l/min: Upgrade to DSH161 series.
  2. Function Comparison for Fast Selection

DSH101NR: Normalmente aperto, free reverse flow → De-energized relief, energized load holding (first choice for single-acting cylinder lowering)

DSH101CR: Normalmente chiuso, free reverse flow → De-energized load holding, energized relief (safety critical power-off holding applications)

Installation Guidelines for Parker DSH101NR (C10-2 Cavity)

  1. Ispezione pre-installazione (Critico)

1.1 Verify Model & Funzione della valvola

DSH101NR: Normalmente aperto + Reverse Free Flow

Definizione del porto: 2→1 controlled flow path; permanent free flow 1→2

⚠️ Reversed port connection will completely invalidate circuit function!

Manifold port marking must match valve flow direction.

1.2 Manifold Cavity Inspection

Standard cavity: SAE C10-2. Non-standard machining will cause seal leakage and valve sticking.

Thoroughly clean cavity: Remove metal chips, burrs and seal debris. Flush with high-pressure oil; do not insert cotton yarn into cavity (risk of fiber contamination and valve seizure).

Inspect sealing face for scratches; surface damage will cause external leakage of outer D-ring.

1.3 Seal Verification

Standard fitted PU polyurethane D-ring (no back-up ring required)

Mineral oil, normal temperature: PU (-37~93℃)

Alta temperatura / synthetic fluid: Replace with NBR or FKM fluorocarbon seal

Never reuse removed seals. Lubricate lightly with clean hydraulic oil before installation. Do not use grease (risk of carbonization and valve sticking).

  1. Cartridge Installation Torque (OEM Standard)

Cartridge threaded torque into manifold: 69~75 N·m

✅ Torque wrench is mandatory!

Coppia insufficiente: Outer D-ring incomplete sealing → external leakage

Excessive torque: Thread stripping, manifold cavity deformation, internal valve damage, sluggish operation and increased leakage.

Procedura di installazione:

  1. Ensure seal fully seated in cartridge groove without twist or extrusion
  2. Thread cartridge manually until seal contacts manifold face
  3. Tighten to specified torque with torque wrench
  4. Do NOT rotate cartridge by gripping solenoid housing; only clamp the hexagonal threaded section!
  5. Solenoid Coil Assembly Requirements
  6. Solenoid locking nut torque: 7~10 N·m

Over-tightening risks cracking solenoid housing.

  1. Assembly sequence:

Positioning washer on cartridge top → Slide coil over actuator pin → Secure with locking nut.

Ensure coil base fully seats flat on cartridge top without tilt or gap.

  1. Coil can be rotated 360° to adjust cable outlet orientation for convenient wiring.
  2. Models with manual override (MS suffix): Confirm manual button can be fully depressed without interference after assembly.
  3. Requisiti del cablaggio elettrico
  4. Supply voltage must stay within 85%~110% of nominal rating. For 24VDC coil, avoid voltage below 20.4V. Undervoltage leads to unreliable valve closure and load slipping.
  5. Waterproof connector treatment: Adequate sealing required for mobile / outdoor equipment to prevent water ingress and coil short circuit. Fit O-rings correctly on Deutsch DT/EV connectors.
  6. Dissipazione del calore: Coil temperature rises during frequent continuous cycling. Do not insulate coil; maintain ventilation space.
  7. EMI control: Route wiring away from inverters and high-power motors to avoid unintended valve actuation.
  8. Hydraulic System & Flushing Requirements
  9. System cleanliness level: ISO 4406 18/16/13. Installare il filtro a monte. Contamination will score poppet sealing surface and cause permanent internal leakage.
  10. Flush manifold without cartridge installed!

Install DSH101NR only after flushing is complete, preventing weld slag entering valve internals.

  1. Initial commissioning: Run no-load at low speed and verify:

No external leakage at manifold interface

Acceptable pressure decay rate during load holding

Veloce, consistent valve actuation on energization / de-energization without delay.

  1. Orientamento di montaggio & Limiti operativi
  2. No mandatory installation orientation: Horizontal or vertical mounting permitted.

For vertically downward loaded cylinders, avoid cartridge facing downwards long-term to prevent sediment accumulation.

  1. Fluid viscosity range: 6~420 cSt. Avoid excessive viscosity at low ambient temperature which slows response.
  2. Rated flow ≤60 L/min; limit pressure differential under sustained high flow to prevent excessive heat generation.
  3. Operazioni vietate & Errori comuni di installazione

❌ Do not tighten by experience without torque wrench

❌ Do not rotate cartridge by clamping solenoid housing, causing eccentric actuator pin and seizure

❌ Do not mix different seal materials; no extra back-up rings needed for PU D-ring

❌ Do not apply thread sealant or PTFE tape on cartridge threads (sealant entering valve causes poppet seizure)

❌ Do not swap Port 1 and Port 2 (reversed flow destroys circuit function)

❌ Do not install valve before full system flushing (high risk of internal leakage and load drift)

  1. Commissioning Check List
  2. Static test: De-energized = passage open; Energized = flow 2→1 blocked; permanent free flow 1→2
  3. Pressure holding test: Monitor pressure decay rate under energized lock condition to evaluate poppet internal leakage
  4. Inspect all sealing positions for external leakage
  5. Verify no abnormal overheating of solenoid after continuous energization