Ordine n.: 2903154
Contatto della Fenice TRIO POWER 2nd-generation three-phase DIN rail switching Alimentazione elettrica with Push-in spring terminals. Designed for powering PLCs, sensors and actuators inside electrical control cabinets. Widely used in machine manufacturing, linee di produzione automatizzate, HVAC and hoisting equipment.
Il codice 2901354 often appears in industry documents as shorthand; the complete official part number is 2903154.
✅ Definizione del modello
TRIO: TRIO POWER series industrial power supply
PS: Alimentazione elettrica
2G: 2Seconda Generazione
3AC: 3-ingresso CA di fase
24DC: 24Uscita V CC
10: Rated output current 10A
📌 Key Technical Specifications
Ingresso
Valutato: 3×400~500V AC; capable of emergency operation with 2×400~500V AC two-phase supply
Raggio d'azione: 3×320~575V AC
Frequenza: 50/60Hz
Corrente in ingresso: 3×0.6A @400VAC
Produzione
Valutato: 24V DC /10A (240W)
Uscita regolabile: 24~28V DC
Potenziamento dinamico: 15A per 5 secondi (to handle inrush loads of motors and capacitors)
Ondulazione & rumore: ≤50mVpp
Protezione da sovratensione OVP: Output clamped ≤30V DC
Meccanico & Ambientale
Montaggio: Guida DIN 35mm
Dimensioni (L × A × P): 42 ×130 ×160 mm
Cablaggio: Push-in screwless spring terminals
Temperatura operativa: -25℃ ~ +70 ℃; derating 2.5%/K above 60℃
Efficienza: >92%
Funzionamento parallelo: Supports parallel connection for capacity expansion and redundancy; series connection for voltage boosting
Protezioni: Sovracorrente, cortocircuito, sovratemperatura, output overvoltage
Segnale: Relay alarm contact (DC-OK signal)
📋 Certificazioni & Applicazioni
Standard: EN61010, UL, CE, PELV protective extra-low voltage
Applicazioni tipiche: Linee di produzione automatizzate, macchine per l'imballaggio, sistemi di trasporto, 24V power supply for control cabinets feeding PLC, Moduli DI/DO, sensors and solenoid valves
High MTBF, adatto per 24/7 continuous industrial operation
⚠️Selezione & Note di sostituzione
- Distinzione del modello: 2903154 is 3-phase 3AC; single-phase 1AC version is 2903149, non mescolarli
- Alternativa domestica: Significa bene SDR-240-24, Delta DRP-240-24 (nota: no dynamic boost capability for inrush current)
- Redundancy solution: When paralleling two 2903154 unità, utilizzare un modulo di ridondanza come QUINT-DIODE
- Installazione: Mantenere uno spazio verticale ≥ 50 mm nella parte superiore e inferiore per la dissipazione del calore; le unità possono essere montate fianco a fianco senza spazio orizzontale
🛠️ Guida alla risoluzione dei problemi
LED ALIMENTAZIONE spento: Controllare l'alimentazione di rete trifase L1/L2/L3; la perdita di qualsiasi fase potrebbe impedire l'avvio; verificare il collegamento a terra PE
Caduta di tensione in uscita / capacità di carico insufficiente: Dai la priorità al controllo dei terminali allentati, bassa tensione di ingresso e declassamento per alte temperature
OK contatto aperto: Sovracorrente in uscita / protezione da cortocircuito o sovratemperatura interna. Scollegare il carico e ripetere il test
Intervento all'accensione a causa dello spunto: Utilizzare la funzione boost e valutare la corrente di picco di commutazione
📦 Codice HS per l'esportazione
8504401400 (Convertitori statici, alimentatore switching industriale, solo per riferimento doganale, soggetto a determinazione doganale locale)
TRIO-PS-2G/3AC/24DC/10 (Ordine n. 2903154)
Efficienza: >92%
Condizione di prova: 400Ingresso VCA, pieno carico nominale
Additional Power Consumption Parameters
Consumo energetico a vuoto: <1.1 W
Power loss at rated load: <22 W
Nota: This value is the nominal figure from Phoenix Contact official datasheet. Actual efficiency under light load (20%~50% load) will be slightly lower than the 92% full-load rating.
TRIO-PS-2G/3AC/24DC/10 (Ordine n. 2903154)
Dimensioni complessive (L × A × P): 42 mm× 130 mm× 160 mm
📌 Installation Clearance (Critical for cabinet layout)
Horizontal sides: Zero gap side-by-side mounting allowed at ambient ≤40℃; reserve 10mm side clearance when temperature approaches 70℃
Verticale: ≥50mm clearance at top and bottom (obbligatorio)
Binario di montaggio: Standard NS35 DIN rail (EN60715)
Peso
ca. 1.1kg
Phoenix Contact TRIO-PS-2G Series Full Model List (TRIO POWER 2nd Generation, Morsetti push-in)
Caratteristiche comuni della serie: Montaggio su guida DIN35, dynamic Boost (1.5×rated current for 5s), DC-OK relay alarm, parallel redundancy support, -25~+70℃, derating 2.5%/K above 60℃
1-phase Input 1AC (100~240 VCA)|24VDC Output
| Modello | Ordine n. | Valutazione dell'uscita | Dimension W×H×D(mm) |
| TRIO-PS-2G/1AC/24DC/3/C2LPS | 2903147 | 24V 3A /72W | 30 ×130 ×115 |
| TRIO-PS-2G/1AC/24DC/5 | 2903148 | 24V 5A /120W | 36 ×130 ×115 |
| TRIO-PS-2G/1AC/24DC/10 | 2903149 | 24V 10A /240W | 42 ×130 ×160 |
| TRIO-PS-2G/1AC/24DC/20 | 2903151 | 24V 20A /480W | 65 ×130 ×160 |
3-phase Input 3AC (3×320~575VAC, rated at 3×400VAC)|24VDC Output (Il tuo gruppo di modelli target)
| Modello | Ordine n. | Valutazione dell'uscita | Dimension W×H×D(mm) |
| TRIO-PS-2G/3AC/24DC/5 | 2903153 | 24V 5A /120W | 36 ×130 ×115 |
| TRIO-PS-2G/3AC/24DC/10 | 2903154 | 24V 10A /240W | 42 ×130 ×160 |
| TRIO-PS-2G/3AC/24DC/20 | 2903155 | 24V 20A /480W | 65 ×130 ×160 |
| TRIO-PS-2G/3AC/24DC/40 | 2903156 | 24V40A/960W | 120 ×130 ×160 |
1-ingresso fase 1 AC|48VDC Uscita
| Modello | Ordine n. | Valutazione dell'uscita | Dimension W×H×D(mm) |
| TRIO-PS-2G/1AC/48DC/5 | 2903159 | 48V5A/240W | 42 ×130 ×160 |
| TRIO-PS-2G/1AC/48DC/10 | 2903160 | 48V10A/480W | 65 ×130 ×160 |
- Accessori coordinati comuni (Per l'integrazione nell'armadio)
- QUINT-DIODE/12-24DC/20 Modulo diodo di ridondanza per ridondanza di doppia alimentazione
- Interruttore automatico CBM E4 24DC/0.5-10A NO-R 4 canali 24V (2905743)
- Interruttore elettronico CBM E8 24DC/0,5-10A NO-R a 8 canali (2905744)
✅ Linee guida per la selezione delle chiavi
- Suffisso C2LPS: Disponibile solo per la variante monofase 3A con funzionalità SIL; non richiesto per progetti di automazione standard
- 3I modelli trifase AC possono funzionare su due fasi (Solo L1/L2)
- Riferimento alla larghezza: 3A=30mm; 5LA=36mm; 10LA=42mm; 20A=65 mm; 40A=120mm, la disposizione dell'armadio dipende principalmente dalla larghezza
Elenco delle certificazioni della serie Phoenix Contact TRIO-PS-2G (Compreso TRIO-PS-2G/3AC/24DC/10, Ordine n.2903154)
Tutti i modelli di questa serie condividono lo stesso pacchetto di certificazione. Solo il modello con suffisso C2LPS ha funzionalità SIL0 extra; i modelli standard sono SIL=0
✅ Certificazioni Globali
- CE (Unione Europea)
Direttiva Bassa Tensione LVD 2014/35/UE
Direttiva EMC 2014/30/UE
- UL / cULus (Elencato UL)
UL508 (Apparecchiature di controllo industriale)
UL60950-1 (Sicurezza informatica)
ANSI/ISA-12.12.01, Classe I Divisione II Gruppi A/B/C/D (adatto per aree pericolose del Nord America)
- Certificato CB IECEE (Schema CB, base per la conversione della certificazione multinazionale)
- Certificazione dell'Unione Doganale EAC (Russia, Bielorussia, Kazakistan e altri mercati EAEU)
- Certificato marino DNV GL (Adatto per armadi di controllo navali e offshore)
- BRI (Licenza BIS per il mercato indiano)
✅ Conformità ambientale
RoHS (Unione Europea)
PORTATA
RAEE conforme alla direttiva sui rifiuti di apparecchiature elettriche ed elettroniche
✅ Sicurezza & Standard funzionali (Standard ≠ Certificati; specifiche di conformità del prodotto)
CEI 60950-1: SELV Sicurezza a bassissima tensione
IN 50178: Protezione a bassissima tensione PELV
IN 60204-1: Sicurezza delle apparecchiature elettriche delle macchine (ampiamente utilizzato per i macchinari)
IN 50121-4: Norma EMC ferroviaria
CEI 61508: SIL 0 (Modelli standard di questa serie; TRIO-PS-2G/1AC/24DC/3/C2LPS è specificamente contrassegnato come sicurezza funzionale SIL0)
Infiammabilità dell'alloggiamento: UL94V0
✅ Standard di compatibilità elettromagnetica EMC
IN 61000-6-1 / 6-2: Immunità (Residenziale / ambienti industriali)
IN 61000-6-3 / 6-4: Radiato & emissioni condotte
IN 61000-3-2: Limiti di corrente armonica
📌 Osservazioni sulla selezione
- Progetti domestici: Nessun certificato CCC, non rientra nell'ambito obbligatorio 3C. CE per l'esportazione nell'UE, UL per il Nord America, EAC per Russia/Asia centrale, DNV per progetti marittimi.
- Livello SIL: Il TRIO-PS-2G standard non può essere utilizzato per i loop di sicurezza SIL1 e superiori. Se è richiesto un livello SIL più elevato, selezionare gli alimentatori con classificazione SIL della serie QUINT.
Contattore,interruttore automatico,sensore,Codificatore,PLC,Convertitore
















NH42-63-318x560.png)