Shinkawa VM-5Z1 Power Supply Unit for Turbine TSI System - Contattore,interruttore automatico,sensore,Codificatore,PLC,Convertitore

Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Di Contatto |

Shinkawa VM-5Z1 Power Supply Unit for Turbine TSI System - Contattore,interruttore automatico,sensore,Codificatore,PLC,Convertitore

PLC/

Shinkawa VM-5Z1 Power Supply Unit for Turbine TSI System

Modello: VM-5Z1 Power Supply Unit Application: Central power supply for all VM-5 monitor cards (vibrazione, shaft displacement, velocità, eccentricity etc.) in the same rack, designed per API 670 standard, widely used in thermal power & petrochemical turbine units. Model Definition VM-5: Shinkawa VM-5 TSI monitoring series Z: Unità di alimentazione 1: Versione (wide AC/DC input, ...

  • Dettagli del prodotto

Modello: VM-5Z1 Power Supply Unit

Applicazione: Central Alimentazione elettrica for all VM-5 monitor cards (vibrazione, shaft displacement, velocità, eccentricity etc.) in the same rack, designed per API 670 standard, widely used in thermal power & petrochemical turbine units.

  1. Definizione del modello

VM-5: Shinkawa VM-5 TSI monitoring series

Z: Unità di alimentazione

1: Versione (wide AC/DC input, different from VM-5Z2 / VM-5Z3)

Suffix `/TRP`: Tropical anti-humidity treatment option

  1. Specifiche elettriche principali

Potenza in ingresso (CE compliant): 85~264VAC / 88~144VDC

Multi-way DC output: +5V, +17V, +24V, -15V, -30V (green Power OK LED on front panel)

Consumo energetico massimo: ≤265VA

Alarm relay: C-form dry contact, normally energized; valutazione dei contatti: 250VAC 5A / 30VDC 5A

Contatta la vita: ≥100,000 operations at rated load

Resistere alla tensione: 2000VCA, 1min between power and ground

Resistenza di isolamento: ≥100MΩ at 500VDC

Temperatura operativa: 0 ~ 65℃; temperatura di conservazione: -30 ~ +85℃

Umidità: 20~95%UR, senza condensa

Peso: Massimo 2.2 kg

Costruzione: Sealed plastic housing with aluminum front panel (Munsell N-1.0 grey)

  1. Montaggio & Compatibilità

Compatible racks: VM-5H4 (10-fessura), VM-5W2 (8-fessura); occupa 2 slot dei moduli

Funzione: OK indicator turns off + relay contact trips upon power failure, sending fault signal to DCS/PLC

Comparison with other power modules

VM-5Z1: Wide AC/DC input, 0~65℃, with Power OK alarm contact

VM-5Z2: Max power ≤135W

VM-5Z3: Single 24VDC input, 0~50℃, no Power OK alarm contact

  1. Applicazione tipica

Turbines, compressori, fans and other rotating machinery TSI protection systems, paired with VM-5T shaft displacement, VM-5C eccentricity, VM-5V vibration, VM-5Q speed monitor cards. Widely used for legacy TSI retrofits in thermal & petrochemical plants.

  1. Pezzi di ricambio & Sostituzione

Stato del prodotto: VM-5 series is mature legacy model, gradually replaced by VM-7 series; available stock mostly includes used, refurbished and surplus new spares.

Sostituzione preferita: Direct same model VM-5Z1; Z2/Z3 cannot be directly swapped due to different input rating, temperature range and alarm logic.

Difetti comuni: No multi-way DC output; Power OK lamp off; failed alarm contact; fusibile di ingresso bruciato.

Operating Principle of Shinkawa VM-5Z1

It is an isolated multi-output switching power supply, dedicated to powering VM-5 rack TSI monitor cards (vibrazione, spostamento, speed etc.). It is a critical component of API 670 rotating machinery protection systems with normally energized alarm relay logic (core requirement for TSI systems).

Flusso del segnale

Input → EMI Rectifier & Filter → High-frequency PWM Inverter → Isolation Transformer → Multi-secondary Rectifier & Stabilization → DC Outputs + Monitoraggio della tensione + Power OK Alarm Relay

  1. Input Stage (Wide AC/DC Compatibility)

Intervallo di ingresso: 85~264VAC (47–63Hz) or 88~144VDC, shared input circuit for AC & DC power.

First stage: EMI filter, surge suppression and input fuse.

Ingresso CA: Converted to high-voltage DC via rectifier bridge.

Ingresso CC: Bypass rectifier directly to post stage.

Core difference between VM-5Z1 and Z2/Z3: universal wide AC/DC input.

  1. High-frequency Inversion & Isolamento (Switching Power Core)

High-voltage DC feeds PWM switching tubes to generate high-frequency square waves driving the isolation transformer.

The transformer provides galvanic isolation between primary power side and secondary sensor/card power side (2000VAC withstand voltage).

The primary PWM chip automatically adjusts duty cycle to stabilize all secondary outputs, adopting a multi-output common voltage regulation architecture.

  1. Independent Secondary Rectification, Filtraggio & Stabilization

Multiple independent secondary windings generate 5 DC power rails for rack logic and sensor circuits:

+5V: Digital circuits, CPU and logic chips (Power OK indicator is powered by this rail, main judgment reference)

+17V: Signal conditioning circuits on monitor boards

+24V: Partial sensor excitation & loop power supply

-15V, -30V: Eddy current probe preamplifiers & analog op-amp negative power

Each rail has independent LC filtering and current limiting to keep low ripple for weak eddy current signal acquisition.

  1. Monitoraggio della tensione & Power OK Alarm Circuit (Caratteristica fondamentale)

Built-in comparator circuit continuously monitors all 5 tensioni di uscita:

All outputs within tolerance window: Green OK lamp ON, relay remains energized (Normally Energized).

Any rail under/over voltage, power loss or internal failure: OK lamp OFF, relay de-energizes and trips, C-form dry contact sends fault signal to DCS.

✅ Critical point: Normally Energized. Relay stays energized under normal operation; releases upon power loss or fault. This is the industry standard fail-safe alarm logic required by TSI systems to avoid missing power failure alarms caused by broken wiring.

  1. Funzioni di protezione integrate

Sovracorrente in uscita & protezione da cortocircuito: Current limiting hiccup mode, auto recovery after fault cleared.

Protezione da sovratensione: Latch shutdown, requires power cycle reset.

Overheat protection: Shuts down output when overtemperature occurs.

The whole unit is fully potted and sealed for anti-vibration and anti-humidity, suitable for power plant and petrochemical field environments; the `/TRP` suffix stands for tropical anti-humidity version.

  1. Coordination with VM-5 Rack

VM-5Z1 occupies 2 slots on VM-5W2 (10-fessura) / VM-5H4 (8-fessura) cremagliera. Multi-way DC power is distributed to all VM-5 cards via backplane copper busbars, eliminating separate power supplies for each monitor card.

Redundant dual power configuration (two VM-5Z1 units) is supported with backplane current sharing; single power failure will not interrupt TSI monitoring & protection output, complying with API 670 requisiti.

  1. Fault Troubleshooting Based on Operating Principle
  2. OK lamp off with no alarm: Main +5V rail undervoltage, monitoring circuit triggers fault directly.
  3. Lamp ON but DCS reports power fault: Burnt relay coil or oxidized contacts (high failure point for long-term energized relays).
  4. One rail low voltage while others normal: Failed rectifier diode or aging filter capacitor on that secondary winding.
  5. Hiccup protection immediately after power-on: Short circuit on backplane caused by faulty monitor card pulling down the power supply.

Full VM-5 TSI Rack Configuration List (Matching VM-5Z1 Power Supply)

Cremagliera: VM-5W2 (10-fessura, supports dual redundant power) / VM-5H4 (8-fessura, single power common)

Core layout constraint: One VM-5Z1 occupies 2 slot

  1. All VM-5 Monitor Card Models & Funzioni
ModelloDescrizioneCanaliMeasurement ApplicationTipo di sensore
VM‑5VShaft Vibration MonitorDual ChannelRadial relative shaft vibrationVK / FK Eddy Current Probe
VM‑5TThrust / Shaft Position MonitorDual ChannelThrust bearing axial displacementVK / FK Eddy Current Probe
VM‑5CRotor Eccentricity MonitorDual ChannelRotor eccentricity (barring & startup)Eddy current + speed pulse
VM‑5DDifferential Expansion MonitorDual ChannelRotor‑casing differential expansionEddy Current Probe
VM‑5ECasing Expansion MonitorDual ChannelAbsolute casing thermal growthEddy current / LVDT
VM‑5QVelocità / Zero Speed MonitorDual ChannelVelocità di rotazione, direzione, zero speed, overspeed protectionMagnetic pickup, gear tooth probe
VM‑5MComposite Vibration MonitorDual ChannelRelative + absolute vibration (lancia + bearing housing vibration)Eddy current + velocity transducer
VM‑5XValve Position MonitorDual ChannelControl valve opening, actuator travelLVDT

Backplane Accessories (No front panel slot occupation)

VM-5Y1 / VM-5Y2 / VM-5Y3: Relay Output Unit, aggregates Alert/Danger dry contacts from all cards and sends unified alarm signals to DCS/ETS; C-form contacts with normally energized logic.

VM-5COM: Modulo di comunicazione (RS485ModbusRTU), uploads 4-20mA measured values and alarm status to RV-200 diagnostic host.

VM-5Z0: Power failure hold-up unit (0.2s buffer for momentary power loss, optional for critical units).

Schema A: VM-5W2 (10-fessura)|Single Power Configuration (1×VM-5Z1)

VM-5Z1 occupies 2 slot; rimanente 8 slots for monitor cards

Standard Turbine TSI Layout (10 slot)

  1. Slot 1~2: VM-5Z1 (Unità di alimentazione)
  2. Scanalatura 3: VM-5T Thrust Shaft Displacement
  3. Scanalatura 4: VM-5C Rotor Eccentricity
  4. Scanalatura 5: VM-5Q Speed / Velocità eccessiva
  5. Scanalatura 6: VM-5D Differential Expansion
  6. Scanalatura 7: VM-5E Casing Expansion
  7. Scanalatura 8: VM-5V Shaft Vibration 1
  8. Scanalatura 9: VM-5V Shaft Vibration 2
  9. Scanalatura 10: VM-5M Composite Vibration (Bearing Vibration spare)

Backplane accessories: VM-5Y Relay Unit + VM-5COM Communication Module (backplane mounted, no slot occupied)

Schema B: VM-5W2 (10-fessura)|Dual Redundant Power (API670 Standard, Most Popular for Power Plants)

Two VM-5Z1 units (2 slots each) → total 4 slots occupied; 6 slots left for monitor cards

  1. Scanalatura 1-2: VM-5Z1 1 (Main Power)
  2. Scanalatura 3-4: VM-5Z1 2 (Standby Power, hot redundant with backplane current sharing)
  3. Scanalatura 5: VM-5T Thrust Displacement
  4. Scanalatura 6: VM-5C Rotor Eccentricity
  5. Scanalatura 7: VM-5Q Rotational Speed
  6. Scanalatura 8: VM-5D Differential Expansion
  7. Scanalatura 9: VM-5V Shaft Vibration A
  8. Scanalatura 10: VM-5V Shaft Vibration B

✅ Redundancy Logic: Two independent power inputs with diode current sharing on backplane. Failure of one VM-5Z1 triggers Power OK alarm without interrupting TSI monitoring & protection output, fully complying with API670 rotating machinery protection standard.

Schema C: VM-5H4 (8-fessura)|Single VM-5Z1 (Small Turbines, Compressori & Tifosi)

VM-5Z1 occupies 2 slot; rimanente 6 slots available

Compact Compressor/Fan TSI Configuration

  1. Scanalatura 1-2: VM-5Z1
  2. Scanalatura 3: VM-5V Shaft Vibration 1
  3. Scanalatura 4: VM-5V Shaft Vibration 2
  4. Scanalatura 5: VM-5T Shaft Displacement
  5. Scanalatura 6: VM-5Q Rotational Speed
  6. Scanalatura 7: VM-5M Composite Vibration
  7. Scanalatura 8: Spare monitor card slot

Front-end Sensor Matching List

VK-202A / VK-302P / VK-602P: Eddy current displacement probes (shaft vibration, posizione, eccentricity, differential expansion)

FK series: High-temperature eddy current probes (high-temperature casing area)

RV Magnetic Pickup: Speed input for VM-5Q monitor

Velocity Transducer: Bearing vibration input for VM-5M

LVDT: VM-5E casing expansion & VM-5X valve position measurement

Selezione & Layout Pitfall Avoidance

  1. VM-5Z1 always occupies 2 slot; cannot be treated as single-slot module. Z2/Z3 also take 2 slots and cannot be mixed due to different input rating and alarm contact logic.
  2. All monitor cards have two fully independent channels, each with separate Alert (Pre-alarm) and Danger (Viaggio) C-form normally energized relay contacts; supports latching or auto reset.
  3. 4-20Uscita analogica mA: Each card has built-in recorder output; alternatively all values can be uploaded centrally via Modbus through VM-5COM.
  4. Tropical version: Add `/TRP` suffix to all card models for coastal & high-humidity power plants (anti-corrosion & anti-moisture treatment).
  5. Expansion limit: Dual power 10-slot rack can only accommodate max 6 monitor cards; additional VM-5 racks are required for more measurement points.

Recommended Spare Parts Kit for One Rack

VM-5Z1 Power Supply Unit (full spare)

Common monitor cards: VM-5V, VM-5T, VM-5Q

Eddy current probes, extension cables and preamplifiers

VM-5Y relay unit & VM-5COM communication card

Full VM-5 TSI I/O List (VM-5W2 10-slot Rack, Dual Redundant VM-5Z1 Power Supply)

Rack Layout Recap: Slot1-2 VM-5Z11; Slot3-4 VM-5Z12; Slot5 VM-5T; Slot6 VM-5C; Slot7 VM-5Q; Slot8 VM-5D; Slot9 VM-5V(UN); Slot10 VM-5V(B)

Backplane Modules: VM-5Y (Alarm Aggregation Relay), VM-5COM (Modbus RTU Communication)

Rules:

  1. Every monitor card has two independent channels CH1 / CH2. Each channel has separate Alert (Pre-alarm) & Danger (Viaggio) C-form normally energized dry contacts plus one isolated 4-20mA analog output.
  2. ModBus: VM-5COM acts as Modbus slave; register addresses shown below are reference offsets (final addresses follow Shinkawa manual 6H14).
  3. Dry contacts are divided into two groups: Local card alarm contacts and VM-5Y aggregated alarm contacts (to ETS/DCS).
  4. Power failure signals: Independent Power OK contacts from each VM-5Z1; only digital alarm, nessuna uscita analogica.

Parte 1: Dry Contact List (C-form, Normally Energized)

Card ModelCanaleNome del segnaleTipo di contatto
VM‑5Z1 #1—Alimentazione elettrica #1 Colpa (Power Fail)C‑form, Normally Energized
VM‑5Z1 #2—Alimentazione elettrica #2 Colpa (Power Fail)C‑form, Normally Energized
VM‑5T Thrust DisplacementCH1Thrust Displacement A Alert (Pre‑alarm)C‑form, Normally Energized
VM‑5T Thrust DisplacementCH1Thrust Displacement A Danger (Viaggio)C‑form, Normally Energized
VM‑5T Thrust DisplacementCH2Thrust Displacement B Alert (Pre‑alarm)C‑form, Normally Energized
VM‑5T Thrust DisplacementCH2Thrust Displacement B Danger (Viaggio)C‑form, Normally Energized
VM‑5C EccentricityCH1Rotor Eccentricity A AlertC‑form, Normally Energized
VM‑5C EccentricityCH1Rotor Eccentricity A DangerC‑form, Normally Energized
VM‑5C EccentricityCH2Rotor Eccentricity B AlertC‑form, Normally Energized
VM‑5C EccentricityCH2Rotor Eccentricity B DangerC‑form, Normally Energized
VM‑5Q Speed / Zero SpeedCH1Speed A AlertC‑form, Normally Energized
VM‑5Q Speed / Zero SpeedCH1Speed A Danger (Overspeed Trip)C‑form, Normally Energized
VM‑5Q Speed / Zero SpeedCH2Speed B AlertC‑form, Normally Energized
VM‑5Q Speed / Zero SpeedCH2Speed B Danger (Overspeed Trip)C‑form, Normally Energized
VM‑5D Differential ExpansionCH1Differential Expansion A AlertC‑form, Normally Energized
VM‑5D Differential ExpansionCH1Differential Expansion A DangerC‑form, Normally Energized
VM‑5D Differential ExpansionCH2Differential Expansion B AlertC‑form, Normally Energized
VM‑5D Differential ExpansionCH2Differential Expansion B DangerC‑form, Normally Energized
VM‑5V Shaft Vibration ACH1Shaft Vibration A‑X AlertC‑form, Normally Energized
VM‑5V Shaft Vibration ACH1Shaft Vibration A‑X DangerC‑form, Normally Energized
VM‑5V Shaft Vibration ACH2Shaft Vibration A‑Y AlertC‑form, Normally Energized
VM‑5V Shaft Vibration ACH2Shaft Vibration A‑Y DangerC‑form, Normally Energized
VM‑5V Shaft Vibration BCH1Shaft Vibration B‑X AlertC‑form, Normally Energized
VM‑5V Shaft Vibration BCH1Shaft Vibration B‑X DangerC‑form, Normally Energized
VM‑5V Shaft Vibration BCH2Shaft Vibration B‑Y AlertC‑form, Normally Energized
VM‑5V Shaft Vibration BCH2Shaft Vibration B‑Y DangerC‑form, Normally Energized
Alarm Aggregation Unit—TSI System General Danger AlarmC‑form
Alarm Aggregation Unit—TSI System General Pre‑alarmC‑form

Valutazione dei contatti: 250VAC 5A / 30VDC 5A. Normally Energized = Closed under normal operation, open upon fault / perdita di potenza, fully complying with API670 fail-safe alarm requirement.

Parte 2: 4-20mA Analog Output List (Isolated AO on each card)

ScanalaturaCard ModelCanaleNome del segnaleGamma tipica (Configurable on card)Produzione
5VM‑5TCH1Thrust Displacement A-1.0 ~ +1.0 mm4‑20mA
5VM‑5TCH2Thrust Displacement B-1.0 ~ +1.0 mm4‑20mA
6VM‑5CCH1Rotor Eccentricity A0 ~ 0.2 mm4‑20mA
6VM‑5CCH2Rotor Eccentricity B0 ~ 0.2 mm4‑20mA
7VM‑5QCH1Rotational Speed A0 ~ 6000 giri/min4‑20mA
7VM‑5QCH2Rotational Speed B0 ~ 6000 giri/min4‑20mA
8VM‑5DCH1Differential Expansion A-5 ~ +25 mm4‑20mA
8VM‑5DCH2Differential Expansion B-5 ~ +25 mm4‑20mA
9VM‑5VCH1Shaft Vibration A X‑axis0 ~ 200 µm4‑20mA
9VM‑5VCH2Shaft Vibration A Y‑axis0 ~ 200 µm4‑20mA
10VM‑5VCH1Shaft Vibration B X‑axis0 ~ 200 µm4‑20mA
10VM‑5VCH2Shaft Vibration B Y‑axis0 ~ 200 µm4‑20mA

Nota: 4mA = lower range limit; 20mA = upper range limit. Two independent AO channels per card. This analog signal is physically separated from Modbus communication for redundant data acquisition.

Parte 3: Modbus RTU Point List (VM-5COM, 16-bit Holding Registers)

Default communication parameters: 9600, 8, N, 1; slave address set via DIP switch; register addresses are reference values (final mapping follows Shinkawa manual 6H14).

Data type: Measured values (INT16 with scaling factor); alarm status (Bit mapped UINT16).

Register AddressTag NameDescrizioneTipo di dati
40001Thrust_Displacement_A_CH1Axial displacement measurementINT16
40002Thrust_Displacement_B_CH2Axial displacement measurementINT16
40003Eccentricity_A_CH1Rotor eccentricity measurementINT16
40004Eccentricity_B_CH2Rotor eccentricity measurementINT16
40005Speed_A_CH1Rotational speed measurementINT16
40006Speed_B_CH2Rotational speed measurementINT16
40007Diff_Expansion_A_CH1Differential expansion measurementINT16
40008Diff_Expansion_B_CH2Differential expansion measurementINT16
40009Shaft_Vib_A_X_CH1Shaft vibration peak‑peak valueINT16
40010Shaft_Vib_A_Y_CH2Shaft vibration peak‑peak valueINT16
40011Shaft_Vib_B_X_CH1Shaft vibration peak‑peak valueINT16
40012Shaft_Vib_B_Y_CH2Shaft vibration peak‑peak valueINT16
40100Channel_Alarm_Word_1Bit0~Bit11: Channel Alert/Danger + sensor breakUINT16
40101Power_Status_WordBit0: VM‑5Z1#1 Fault; Bit1: VM‑5Z1#2 FaultUINT16
40102Rack_System_StatusComunicazione, card self‑test & backplane fault flagsUINT16

Bit Definition for Register 40100 (Channel Alarm Word)

Bit0: VM-5T CH1 Alert

Bit1: VM-5T CH1 Danger

Bit2: VM-5T CH2 Alert

Bit3: VM-5T CH2 Danger

Bit4: VM-5C CH1 Alert

Bit5: VM-5C CH1 Danger

Bit6: VM-5C CH2 Alert

Bit7: VM-5C CH2 Danger

Subsequent bits follow in sequence and can be extended according to actual measurement points.

Parte 4: Design Notes & Signal Redundancy

  1. ETS Trip Logic: All Danger trip contacts shall adopt 1-out-of-2 or 2-out-of-2 voting logic per turbine protection standards. Power fault contacts shall only generate alarm, not initiate ETS trip.
  2. Triple Redundant Signal Path: Hard relay contacts (safety trip) + 4-20mA analog (DCS trend) + ModBus RTU (host diagnostic data) are fully independent physical links.
  3. Rilevamento rottura sensore: Every monitor card has built-in probe break detection; open circuit will trigger Alert/Danger alarm and set corresponding bit in Modbus status word.
  4. If you need a simplified I/O list for single-power VM-5W2 / VM-5H4 rack, I can provide a trimmed version immediately.

Parte 5: I/O Quantity Summary (Dual Power Scheme)

Power digital contacts: 2 punti

Channel Alert pre-alarm contacts: 12 punti

Channel Danger trip contacts: 12 punti

VM-5Y aggregated alarm contacts: 2 punti

4-20mA analog output channels: 12 canali

Modbus measurement registers: 12 pz; status registers: 3 pz

Prec:

Lascia una risposta

Lasciate un messaggio