FUNGO 750330 Relè di sicurezza

Modello completo: PNOZ s7 C 24VDC 4 n/o 1 n/c Pilz PNOZsigma Series Safety Relay Basic Specifications Order No.: 750330 Fornitura: 24 V DC Safety Contacts: 4 normalmente aperto (n/o) Contatto ausiliario: 1 normalmente chiuso (n/c) Larghezza: 22.5 mm Function: For safety emergency stop, monitoraggio dei cancelli di sicurezza, two-hand control and other safety circuit evaluation Series: ...

  • Dettagli del prodotto

Modello completo: PNOZ s7 C 24VDC 4 n/o 1 n/c

Pilz PNOZsigma Series Relè di sicurezza

Specifiche di base

Ordine n.: 750330

Fornitura: 24 A DC

Contatti di sicurezza: 4 normalmente aperto (n/o)

Contatto ausiliario: 1 normalmente chiuso (n/c)

Larghezza: 22.5 mm

Funzione: For safety emergency stop, monitoraggio dei cancelli di sicurezza, two-hand control and other safety circuit evaluation

Serie: PNOZ s7 C (C = with cascade interface, for connecting extension modules)

Certificazioni: CE, UL, TÜV; Safety Level PL e/SIL 3 (Compliant with ISO 13849-1/IEC 62061)

Applicazioni tipiche

Emergency stop button circuit monitoring

Safety gate switches, safety limit switches

Small automation machines, macchine utensili, packaging machinery safety control

Can be cascaded with PNOZsigma extension modules (s0, s1, s2, s4, s5, s6, s7, s8, s9) for contact expansion

Confusing Model Comparison

750107: PNOZ s7 (without C, no cascade function)

750330: PNOZ s7 C (cascade-capable version)

Note sul cablaggio

  1. S11/S12: Safety Input Channel 1
  2. S21/S22: Safety Input Channel 2 (Dual-channel monitoring)
  3. 13/14, 23/24, 33/34, 43/44: Four safety normally open outputs
  4. 51/52: Auxiliary normally closed feedback contact
  5. UB/0V: 24Alimentazione Vcc

Riferimento sostitutivo

Sostituzione della stessa serie: Original product is preferred for the same specification; domestic safety relays can be used for functional replacement (PL level, contact configuration and wiring logic must be verified)

Aggiornamento: If more contacts are required, cascade with PNOZ s extension modules

Informazioni aggiuntive

Classe di protezione: IP20 (Montaggio su guida DIN, solo per installazione in armadio)

Montaggio: Guida DIN 35mm

Temperatura operativa: -10 ℃ ~ +55 ℃

FUNGO 750330 (PNOZ s7 C) Istruzioni di cablaggio + Elenco di controllo per la risoluzione dei problemi

Important Precaution: PNOZ s7 C is a contact extension module. It cannot be used as a standalone master module. It must be used with PNOZsigma master safety relays (s1/s2/s4/s5/s6 etc.); C = cascade connector, connected to master module via U-link. It is NOT an independent evaluation unit.

  1. Definizione del terminale

A1: 24VDC+

A2: 24VCC-

Uscite di sicurezza (Force-guided normally open, per circuiti di sicurezza)

13-14, 23-24, 33-34, 43-44 (4 sets n/o)

Contatto ausiliario (Not allowed for safety cut-off circuits, only for PLC feedback/indicator lamps)

51-52 (1 set n/c)

Top side: Cascade slot + Terminator plug

  1. Two Wiring Schemes

Schema 1: Cascade with PNOZsigma Master Module (Raccomandato, with pulse detection)

  1. Mount master module and s7 C side by side on DIN rail, remove terminator plugs on both modules
  2. Insert PNOZsigma U-link connector; internal safety signals are transmitted from master module to s7C
  3. Master module is powered at A1/A2; s7C A1/A2 also requires separate 24V DC supply
  4. Route outputs 13-14/23-24/33-34/43-44 into contactor coil circuits; a 6A fuse is recommended to prevent contact welding
  5. 51-52 is wired to PLC digital input for status feedback

Cascade Rule: The terminator plug must be fitted on the LAST module of the cascade chain! Fault will be triggered if missing.

Schema 2: Hardwired extension for non-sigma series (PNOZ X etc., no U-link)

The safety output contact of the master relay is wired into the s7 C supply loop (master safety contact acts as enable for s7C power supply)

Master contact closed → s7C energized, all safety outputs closed

Master contact open → s7C de-energized, all safety outputs open

⚠️ No internal short-circuit pulse diagnosis in this mode. Safety architecture is downgraded, only for low-risk applications.

  1. Safety Wiring Rules
  2. Massimo. load for safety outputs: ≤6A, 240VCA; fuses are mandatory to avoid contact welding
  3. 51-52 auxiliary contact must not be used for safety cut-off, only for status signals
  4. Cavo: Copper wire with ferrule for cabinet wiring, terminale a molla; IP20, no exposed wiring
  5. Emergency stop/safety gate logic is fully configured on the PNOZsigma master module (mode selector, dual-channel detection, auto/manual reset). s7C only follows the output state
  6. Check U-link connection regularly for vibration-prone applications (macchine utensili, trasportatori)
  7. Definizione dell'indicatore LED (PNOZ s7C itself)

ENERGIA: 24V supply present

FUORI: Safety outputs closed (master module permits output)

COLPA: Diagnostic error/fault lockout

IN1, IN2 indicators are located on the master module. The s7C extension module has no input indicators.

  1. Elenco di controllo per la risoluzione dei problemi (in sequenza)

Colpa 1: FAULT LED ON continuously, nessuna uscita (più frequente)

Causa 1: Terminator plug missing or not installed on the last module

Rimedio: Spegnimento, fit terminator plug on the last module’s cascade slot, power on and reset

Causa 2: U-link loose or not fully clipped

Rimedio: Spegnimento, re-seat U-link and confirm locking

Causa 3: No supply/reversed polarity/excessive voltage drop on A1/A2

Rimedio: Measure A1-A2 voltage with multimeter, confirm stable 24VDC; check spring terminal loose connections

Causa 4: Master module FAULT, wrong mode setting, short circuit on master input channels

Rimedio: Troubleshoot master module first; s7C will only work normally once master is recovered

Colpa 2: POWER LED ON, OUT LED OFF, FAULT LED OFF

Causa 1: Master safety relay is in safe-off state (E-stop pressed, safety gate open)

Rimedio: Reset E-stop/close safety gate, confirm master OUT LED lights up

Causa 2: Master module set to manual reset and reset button not pressed

Causa 3: Wrong cascade order; master module is not the first unit in chain

Causa 4 (hardwired mode): Master safety contact damaged/open circuit

Colpa 3: Intermittent FAULT trigger, output flickering

Causa 1: U-link loose due to cabinet vibration (macchine utensili, linee di trasporto)

Causa 2: High ripple/insufficient capacity/frequent dip on 24V power supply

Causa 3: Short circuit on output circuit, fuse blown and safety lockout activated

Causa 4: Cross-wire/earth short circuit on master module input wiring (pulse detection triggers fault)

Colpa 4: FAULT latched, cannot reset after power cycle

Causa: Internal safety contact welding (overload/short circuit without fuse protection)

Rimedio: Module cannot be repaired; sostituire direttamente. Add fuses on output circuits to prevent recurrence.

Colpa 5: Master module normal, s7C output out of sync

Causa: Poor U-link contact; or welded contact on intermediate contactor in hardwired configuration

  1. Standard Commissioning Procedure
  2. Spegnimento, mount on DIN rail, wire power supply, fit U-link and terminator plug
  3. Wire master module and set mode selector (adjust selector only when power OFF; changing under power will lock fault)
  4. Verify fuses on all safety output loops
  5. Accendere. Master IN1/IN2 OK, master OUT ON → s7C POWER + OUT ON
  6. Prova di funzionalità: Trigger E-stop/open gate → master OUT OFF, s7C OUT opens synchronously; reset and confirm synchronous closing
  7. Documentazione: Safety function verification must be performed after every wiring change or module replacement
  8. Quick Comparison: s7 (750107) vs s7 C (750330)

750107: PNOZ s7, estensione, no C, U-link cascade not supported

750330: PNOZ s7 C, estensione, C version, U-link cascade supported (il tuo modello)

Working Principle of PILZ 750330 (PNOZ s7 C)

Riepilogo principale: It has no input channels and no safety logic evaluation function. It is a follower-type extension module equipped with force-guided safety contacts. Safety judgement, dual-channel detection and short-circuit pulse diagnosis are all performed by the upstream PNOZsigma master module. The s7 C only synchronously follows the master safety command and feeds back its actual contact status to the master for verification.

Importante: PL e/SIL3 safety rating is determined by the master module. s7 C alone cannot raise the safety level.

  1. Internal Hardware Structure

Interno: Two independent safety relays with mechanically linked force-guided contacts, 4 safety normally open outputs + 1 auxiliary normally closed feedback contact

Alimentazione elettrica: Independent 24VDC supply on A1/A2 (not powered by master module)

Top U-link port: Dual-channel drive signals + feedback return line, safety link; not ordinary communication bus

Terminator plug: Closing component for the end of cascade chain, used by master module to confirm chain integrity; fault is triggered if removed

  1. Standard Cascade Mode (U-link connection, recommended dual-channel safety architecture)
  2. Master module (s1/s2/s4/s5/s6 etc.) collects E-stop and safety gate signals, performs dual-channel comparison, cross-line short-circuit pulse detection and reset logic
  3. When safety conditions are satisfied, master sends synchronized dual-channel drive signals to s7 C via U-link
  4. s7 C receives valid drive signals → internal two safety relays pull in simultaneously, 13-14, 23-24, 33-34, 43-44 four safety contacts close
  5. Critical safety closed-loop: The actual contact state of s7 C is sent back to master module via cascade lines

Master continuously compares: issued command vs real feedback contact status

Matched: Funzionamento normale

Mismatched (saldatura a contatto, failure to act, rottura del filo, loose U-link): Master cuts drive immediately, whole safety chain locks FAULT, safety contacts force open

  1. Once safety trip condition occurs (E-stop pressed, cancello di sicurezza aperto): Master stops drive signal → s7C relays de-energize, all safety contacts open; status feedback is sent back to master for verification

This bidirectional verification is the core of force-guided contact + feedback monitoring, preventing dangerous failure mode where contacts remain conductive after open command due to welding.

  1. Hardwired Mode (without U-link, downgraded single-channel)

Master safety output contact is wired into s7C supply enable loop:

Master contact closed → s7C energized, outputs closed

Master contact open → s7C de-energized, uscite aperte

⚠️ Defect: No dual-channel feedback. Master cannot diagnose internal faults of s7C. Safety architecture no longer meets PL e, only for low-risk applications.

  1. LED Logic

ENERGIA: A1/A2 24V supply OK

FUORI: Valid drive signal received from master, safety contacts closed

COLPA: Master detects chain anomaly (loose U-link, missing terminator, inconsistent feedback, broken cascade line), safety lockout activated

  1. Diagnosis Principle (Why missing terminator triggers FAULT)

The whole cascade chain forms a serial closed diagnostic loop: Master → s7C1 → s7C2 → … → terminator plug on last module.

Master continuously sends diagnostic pulses scanning the whole chain. The terminator acts as an end termination resistor to close the pulse circuit.

Plug removed → pulse circuit open → master detects broken chain and locks FAULT to prevent uncontrolled extension module behaviour.

  1. Function Division: Master vs s7 C

Master Module:

Connect E-stop/safety gate inputs

Rilevamento a doppio canale, cross-wire short-circuit detection, logica di ripristino

Send drive commands + receive feedback and fault judgement from all extension modules

PNOZ s7 C (750330):

No input terminals, cannot connect E-stop

Azione: Pull in/open safety contacts synchronously

Feed back real contact status continuously to master for verification

Only increases available safety contacts, no safety logic evaluation

  1. Core Safety Design

Internal relays adopt mechanical force-guided structure: If one relay contact welds closed, the mechanical coupling ensures the other contact opens reliably. This anomaly is fed back to master and triggers fault lockout, avoiding dangerous “command open but contact conductive” failure.

Pilz PNOZ Safety Relay Order List

Nota: PNOZsigma (750xxx/751xxx) is current mainstream series; PNOZ X (774xxx /777xxx /787xxx) is legacy classic series; PNOZmulti2 is programmable safety controller. s7 C (750330) is sigma contact extension module and cannot be used standalone.

Abbreviation: n/o=normally open, n/c=normally closed, n/o t=delayed-off normally open, SC=semi-conductor output

  1. PNOZsigma Series (24VCC, preferito, PL e/SIL3)

Standalone Master Modules (can work alone for E-stop/safety gate)

Ordine n.Modello completoSpecifica di contattoLarghezzaOsservazioni
750101PNOZ s1 24VDC 2n/o2NO12.5mmCanale singolo, di base
750102PNOZ s2 24VDC 3n/o 1n/c3NA+1NC17.5mmCanale singolo
750103PNOZ s3 24VDC 2n/o2NO17.5mmDual-channel short-circuit detection
751103PNOZ s3 C 24VDC 2n/o2NO17.5mmCascade C version
750104PNOZ s4 24VDC 3n/o 1n/c3NA+1NC22.5mmDoppio canale, ampiamente utilizzato
750105PNOZ s5 24VDC 2n/o 2n/o t2NO+2 delayed NO22.5mmDelay-off type
750106PNOZ s6 24VDC 3n/o 1n/c3NA+1NC22.5mmTwo-hand control dedicated
750107PNOZ s7 24VDC 4n/o 1n/c4NA+1NC22.5mmEstensione, no U-link cascade
750330PNOZ s7 C 24VDC 4n/o 1n/c4NA+1NC22.5mmCascade C version, U-link compatible (il tuo modello)
750108PNOZ s8 24VDC 2n/o2NO12.5mmSmall contact extension
750109PNOZ s9 24VDC 3n/o3NO17.5mmContact extension
750110PNOZ s10 24VDC 2n/o2NO12.5mmDual-channel light curtain
750111PNOZ s11 24VDC 4n/o4NO22.5mmDoppio canale
750124PNOZ s4.1 24VDC3NA+1NC22.5mmSpecial reset mode
750126PNOZ s6.1 24VDC3NA+1NC22.5mmImproved two-hand control
750150PNOZ s20 24VDCSemi-conductor output12.5mmPure semiconductor
750151PNOZ s22 24VDCSemi-conductor output17.5mmLight curtain dedicated
750130PNOZ s30 24VDC2NO+2 delayed NO22.5mmLungo ritardo
750152PNOZ s50 24VDCSemi-conductor22.5mmSemi-conductor safety output

Sigma Accessories

Ordine n.Descrizione
750008PNOZsigma U-link Cascade Connector
750009Terminator Plug (mandatory at end of chain)
  1. PNOZ X Legacy Series (AC/DC universale, for replacement of existing projects)

Basic E-stop/Safety Gate Models

Ordine n.ModelloContattiFornitura
777303PNOZ X2P2NO24VCA/CC
787059PNOZ X7P C2NO24VCA/CC
774053PNOZ X72NO110VCA
774055PNOZ X72NO120VCA
774057PNOZ X72NO240VCA
787100PNOZ X1P C3NA+1NC24VCC
787310PNOZ X3P C3NA+1NC24VCA/CC
774729PNOZ X63NO24VCA/CC
774080PNOSI 117NA+1NC24VCA/CC
774006PNOSI 106NO+4NC230-240VCA

Delay-off XV Series

Ordine n.ModelloContattiIntervallo di ritardo
777510PNOZ XV3P 303NO+2 delayed NO0.1~30s
774610PNOZ XV3.1 303NO+1NC+2 delayed NO0.1~30s
774618PNOZ XV3.1 3003NO+1NC+2 delayed NO0.3~300s

Two-hand Control P2HZ Series

Ordine n.ModelloContatti
777340P2HZ X1P3NO+1NC+2SC
774350P2HZ X32NA+1NC
774360P1HZ X12NO

Contact Extension PZE Series (for PNOZ X master)

Ordine n.ModelloContatti
774580PZE X44NO
777580PZE X4P4NO
774590PZE X55NO
777600PZE 9P7NO+2NC
  1. PNOZmulti 2 Programmable Safety Controllers (Large machines, multi safety functions)
Ordine n.ModelloDescrizione
772100PNOZ m B0Unità base, espandibile
772104PNOZ IB0.1B0 upgraded version
772105PNOZmC0Compatto, non-expandable
772138PNOZ m ES ETHModulo di comunicazione Ethernet
  1. Guida alla selezione rapida
  2. 750xxx = PNOZsigma new series; 750xxx without C = standalone/hardwired extension; 751xxx /7503xx with C = U-link cascade supported
  3. 774/777/787xxx = PNOZ X legacy series, for spare replacement only, non consigliato per nuovi progetti
  4. 772xxx = PNOZmulti2 programmable safety controller (not simple safety relay)
  5. s7 (750107) and s7C (750330) are both extension modules, cannot connect E-stop independently, must pair with sigma master
  6. Confusing Model Reference

750107: PNOZ s7, estensione, no C, U-link cascade not supported

750330: PNOZ s7 C, estensione, C version, U-link cascade supported