Schmersal SRB301MC-24V Safety Relay

The Schmersal SRB301MC-24V is a high-performance safety relay module. I suoi principali vantaggi includono 3 safety contacts plus 1 uscita del segnale, STOP 0 stop category, Performance Level e (PL e) and diagnostic coverage ≥99%. It is widely deployed in safety protection systems for various industrial automation equipment. Featuring a dedicated design for magnetic safety switches and ...

  • Dettagli del prodotto

IL Schmersal SRB301MC-24V is a high-performance safety relay module. I suoi principali vantaggi includono 3 safety contacts plus 1 uscita del segnale, STOP 0 stop category, Performance Level e (PL e) and diagnostic coverage ≥99%. It is widely deployed in safety protection systems for various industrial automation equipment. Featuring a dedicated design for magnetic safety switches and cross-wire detection function, it delivers outstanding performance in safety gate monitoring applications. Please check compatibility with safety input devices during model selection, and strictly follow wiring specifications during installation to ensure safe and reliable system operation.

  1. Spiegazione del codice modello

The SRB301MC-24V is a safety relay module of the PROTECT SRB series manufactured by Schmersal, Germania. The breakdown of the model code is as follows:

Segmento di codiceDefinizione
SRBCodice della serie: Safety Relay Block
301Codice funzione: 3 safety contacts and 1 uscita del segnale, compatible with single/dual-channel safety inputs
MCCharacteristic code: Designed for signals from BNS series magnetic safety switches, supports cross-wire detection
24VTensione operativa nominale: 24V CA/CC, compatible with AC and DC power supply

Numeri d'ordine: 101190684 (Versione standard), 161190684 (International Version), 151190684 (China Version)

  1. Principali Specifiche Tecniche
CategoriaDati tecniciOsservazioni
General Specifications
TipoSafety monitoring module, emergency stop safety relaySTOP 0 stop category
Tensione operativa24V e (-15%/+10%) / 24A DC (-15%/+40%)Maximum ripple voltage: 10%
Consumo energetico2WLow power consumption design
Protezione dall'ingressoIP20 (Terminali) / IP40 (Alloggiamento)Suitable for control cabinet installation
Caratteristiche di ingresso
Monitoring ChannelsSwitchable single/dual channelCross-wire detection supported
Tipo di ingressoPassive contacts / Active signals (AOPDs)Compatible with safety light curtains, pulsanti di arresto di emergenza, ecc.
Corrente in ingresso>500mAReset time of monitoring circuit: ca. 1 secondo
Caratteristiche di uscita
Safety Contacts3 contatti (2NC + 1NO)DC13: 24V/6A; AC15: 230V/6A
Signal Output1 contatto ausiliarioFor status indication or alarm
Livello di prestazionePL e (Highest level)Conforme alla norma EN ISO 13849-1
Categoria di sicurezzaCategoria 4Compliant with EN IEC 61508
Diagnostic Coverage≥99%Design ad alta affidabilità
Caratteristiche fisiche
Dimensioni22.5mm × 100mm × 121mmMontaggio su guida DIN, salvaspazio
Montaggio35Guida DIN standard da mmStandard industrial mounting
Temperatura operativa-25°C~60°CWide temperature range for industrial environments
TerminaliMorsetti a viteCable cross-section: 0.25mm² ~ 2.5mm²
CertificazioniBG, UL, CSA, CEConforme agli standard di sicurezza internazionali
  1. Cross-Brand Compatibility List
MarcaModello sostitutivoDescrizione della compatibilità
SchmersalSRB E 301MC-24V (103014374)Enhanced replacement, fully compatible with improved performance
Siemens3SK1111-1AB30Equivalent safety relay, 3 safety contacts, 24A DC
SchneiderXPSAC512124V CA/CC, 3 safety contacts and 1 uscita del segnale
OmronG9SA-321-T07524A DC, 3 safety contacts, STOP 0 stop category
ABBMSR132TP24V CA/CC, 3 safety contacts, single/dual channel

Selection Guideline: Match voltage and contact quantity; do not downgrade safety performance level; keep identical mounting dimensions.

  1. Full Model List of SRB Series
ModelloVoltaggioConfigurazione dei contattiFunzioni specialiNumero d'ordine
SRB301MC-24V24V CA/CC3 Sicurezza (2NC+1NO) + 1 SegnaleFor magnetic switches, cross-wire detection101190684
SRB301MC-24V-STSS24V CA/CC3 Sicurezza (2NC+1NO) + 1 SegnaleProtezione da cortocircuito, for magnetic switches101190685
SRB301-24V24V CA/CC3 Sicurezza (2NC+1NO) + 1 SegnaleGeneral type, no optimization for magnetic switches101190686
SRB302MC-24V24V CA/CC4 Sicurezza (3NC+1NO) + 1 SegnaleDual-gate monitoring, for magnetic switches101190687
SRB301MC-110V110V e3 Sicurezza (2NC+1NO) + 1 SegnaleFor magnetic switches, high voltage version101190688
SRB301MC-230V230V e3 Sicurezza (2NC+1NO) + 1 SegnaleFor magnetic switches, high voltage version101190689
  1. Difetti comuni & Risoluzione dei problemi
Fenomeno di guastoPossibili causeSoluzioni
Power indicator off1. Power disconnected or abnormal voltage1. Check power connection and voltage (20.4V~28.8V)
2. Internal fuse blown2. Replace 2A internal fuse
Safety contacts fail to operate1. Segnale di ingresso anomalo1. Inspect safety input devices (E-stop, light curtains, ecc.)
2. Incorrect cross-wire detection setting2. Adjust QS switch (Superiore: cross-wire protection off; Metter il fondo a: cross-wire protection on)
3. Damaged contacts3. Replace the safety relay module
No signal output1. Safety circuit not reset1. Check reset conditions (manual/automatic reset)
2. Damaged signal output contacts2. Test continuity of signal contacts
Frequenti falsi interventi1. Interferenza elettromagnetica1. Add shielding and keep away from interference sources
2. Poor cable connection2. Recheck cable connections
3. Ambient temperature out of range3. Ensure temperature within -25°C ~ 60°C

Check power first, then inputs; wrong settings are common causes; watch out for interference and reset requirements.

  1. Ambienti applicativi & Casi di settore

6.1 Scenari applicabili

Machinery Safety Protection: Emergency stop systems for injection molding machines, punch presses, press brakes and other stamping equipment

Automation Production Lines: Signal processing for safety light curtains to prevent personnel from entering hazardous areas

Logistica & Magazzinaggio: Safety gate monitoring for stackers and conveyors with BNS magnetic safety switches

Macchine per l'imballaggio: Safety interlock for filling and labeling machines to ensure operational safety

Produzione automobilistica: Safety zone monitoring for welding robots and coating lines

6.2 Not Recommended Scenarios

Harsh outdoor environments: IP20 protection rating is not suitable for outdoor installation

Highly corrosive environments: No anti-corrosion coating, incompatible with acid, alkali and corrosive media

High vibration environments: Vibration over 5g may shorten relay service life

High temperature over 60°C: Will degrade performance and service life

6.3 Application Cases

Caso 1: Stamping Production Line for Automotive Parts

Applicazione: Emergency stop system and signal processing of safety light curtains for 3 punch presses

Configurazione: One SRB301MC-24V installed on each press, connected with emergency stop buttons and safety light curtains

Effetto: Realizes instant STOP 0 shutdown with diagnostic coverage ≥99%, reducing safety risks

Caso 2: Safety System for Food Packaging Machinery

Applicazione: Safety gate monitoring for filling and capping machines with Schmersal BNS magnetic safety switches

Configurazione: SRB301MC-24V monitors 2 safety gates; cross-wire detection prevents cable failures

Effetto: Complies with food industry safety standards and improves equipment reliability

Caso 3: Stackers in Automated Warehouse

Applicazione: Safety gate monitoring and emergency stop system for stacker aisles

Configurazione: SRB301MC-24V connected to magnetic safety switches and E-stop buttons; signal output linked to PLC

Effetto: Stacker is locked when safety gates are open, upgrading warehouse safety level

Detailed Application Cases of Schmersal SRB301MC-24V Safety Relay

This model is optimized for magnetic safety switches, dual-channel monitoring and cross-wire detection, compliant with PL e / Categoria 4. It is widely used for safety gates, emergency stops and safety light curtains. Below are practical industry cases including wiring schemes, operation methods and application values.

  1. Machine Tool Industry (Applicazione principale)

Caso 1: Safety Gate & E-Stop Interlock for CNC Punch Press / Press Brake

  1. Dispositivi corrispondenti: Schmersal BNS magnetic safety switches (machine protective gates) + Mushroom-head emergency stop buttons
  2. Operazione:

Adopt dual-channel input and cross-wire detection to monitor front and rear protective gates;

Safety contacts open immediately when gates are opened or E-stop is triggered, executing STOP 0 instant shutdown;

Auxiliary signal contacts connect to PLC for gate status and fault alarm upload.

  1. Valore: Prevent personnel from accessing stamping hazardous areas; detect cable breakage and short circuit to avoid safety failure.

Caso 2: Rotating Hatch Monitoring for Machining Centers

  1. Dispositivi corrispondenti: BNS magnetic safety switches (rotating protective gates)
  2. Operazione: Switchable single/dual channel; equipment cannot start if gates are not fully closed; power circuit cuts off immediately if gates are opened during operation.
  3. Attrezzatura applicabile: Vertical machining centers, drilling & fresatrici, grinders.
  4. Automation Production Lines & Robotica

Caso 1: Safety Fence Monitoring for Robot Workcells

  1. Dispositivi corrispondenti: Magnetic safety switches (fence access gates) + Safety light curtains
  2. Operazione:

Signals from safety gates and light curtains are wired in series to the relay;

Robot stops and locks when personnel intrude or gates are opened; on-site reset is required for restart.

  1. Scenari tipici: Automotive component handling, welding robots, loading/unloading robot cells.

Caso 2: Centralized Emergency Stop Control for Production Lines

  1. Operazione: Emergency stop buttons at multiple workstations are connected in parallel to the module, cutting off power of motors and conveyors via unified safety circuit.
  2. Vantaggi: Fast response and powerful circuit diagnosis, ideal for full-line safety interlock.
  3. Confezione, Cibo & Pharmaceutical Machinery

Caso 1: Guard Safety Protection for Automatic Filling & Sealing Machines

  1. Dispositivi corrispondenti: BNS non-contact magnetic safety switches (movable machine guards)
  2. Operazione:

Frequent opening/closing of guards in food equipment leads to no mechanical wear for magnetic switches and longer service life;

Enable cross-wire detection to avoid safety hazards caused by aging and short-circuited cables in humid environments.

  1. Attrezzatura applicabile: Beverage fillers, daily chemical packaging machines, pharmaceutical blister packaging machines.

Caso 2: Access Gate Interlock for Carton Packaging & Palletizing Machines

Magnetic switches are installed on equipment access gates. The palletizing mechanism and conveyors lock completely once gates are opened, protecting maintenance personnel.

  1. Logistica & Warehousing Equipment

Caso 1: Aisle Safety Gate Monitoring for Warehouse Stackers

  1. Monitoring Points: Protective gates and access gates of stacker travel aisles
  2. Logica: Stacker is disabled for travelling and lifting when gates are open; immediate shutdown and alarm during operation.
  3. Caratteristica: Cross-wire detection effectively diagnoses faults of long-distance cables in warehousing systems.

Caso 2: Zone Safety Protection for Belt / Roller Conveyors

Access gates on both sides of conveyors and line-mounted E-stop buttons are connected to the module, realizing full-section emergency stop. Widely used in express sorting and material conveying lines.

  1. Rubber, Plastica & Injection Molding Machinery

Caso: Safety Gate & Mold Area Protection for Injection Molding Machines

  1. Dispositivi corrispondenti: Magnetic safety switches (anteriore & rear safety gates of injection machines)
  2. Operazione: Mold opening and part picking areas are high-risk zones. Mold closing action is locked when gates are opened to prevent pinching accidents. Complies with national safety standards for rubber & plastic machinery.
  3. General Auxiliary Applications (Piccole attrezzature & Control Cabinets)

Caso: Small Automated Tooling & Test Equipment

For various custom assembly and test tooling, this relay builds cost-effective high-level safety circuits (Categoria 4 / PL e) with single E-stop and simple protective gates, suitable for small and medium-sized custom equipment.

Supplementary Operation Notes

  1. For optimal performance, use with Schmersal BNS magnetic safety switches (original manufacturer recommended combination).
  2. Enable cross-wire detection for long-distance wiring, humid or dusty sites.
  3. All above applications meet EN ISO 13849 PL e and Category 4, acceptable for equipment exported to the EU.