Schneider A9L16634 Surge Protective Device

Schneider ACTI-9 IPRF1-12.5R-3P+N-A9L16634 Surge Protective Device (SPD) Model Code Definition Full Model Breakdown: ACTI-9-IPRF1-12.5R-3P+N-A9L16634 Code Segment Definition Detailed Description ACTI-9 Product Series Code for Schneider Electric ACTI-9 modular low-voltage distribution series IPRF1 Product Type Plug-in Type T1+T2 combined SPD with voltage-limiting structure 12.5R Core Parameter 12.5: Maximum impulse current Imax=12.5kA; R: Equipped with remote indication ...

  • Dettagli del prodotto

Schneider ACTI-9 IPRF1-12.5R-3P+N-A9L16634 Dispositivo di protezione contro le sovratensioni (SPD)

  1. Definizione del codice modello

Analisi completa del modello: ACTI-9-IPRF1-12.5R-3P+N-A9L16634

Segmento di codiceDefinizioneDescrizione dettagliata
ACTI-9Serie di prodottiCode for Schneider Electric ACTI-9 modular low-voltage distribution series
IPRF1Tipo di prodottoPlug-in Type T1+T2 combined SPD with voltage-limiting structure
12.5RParametro fondamentale12.5: Maximum impulse current Imax=12.5kA; R: Equipped with remote indication contact
3P+NConfigurazione del palo3-fase + neutral pole protection, applicable to 230/400V three-phase four-wire power system
A9L16634Codice ordineUnique official Schneider part number for procurement and inventory management

Full Product Description: Acti9 iPRF1 12.5r 3P+N 350V Plug-in T1+T2 Surge Protector with Remote Indication

iPRF1: Pluggable design for easy maintenance & replacement without power cut-off

T1+T2: Comply with both Class I (10/350μs) e Classe II (8/20μs) surge protection criteria

350V: Maximum continuous operating voltage Uc, matched for standard 230/400V AC power grid

Remote indication: Fault dry contact output for BMS/monitoring system integration

  1. Specifiche tecniche principali

Parametri elettrici di base

ArticoloValoreUnitàOsservazioni
Tipo di prodottoT1+T2 combined SPDVoltage-limiting design against direct & induced lightning surge
Pole3P+NFull protection for three-phase four-wire including neutral line
Max Continuous Operating Voltage (Uc)350V eSuitable for 50/60Hz 230/400V low voltage grid
Rated System Voltage (E)230/400V eStandard LV distribution nominal voltage
Max Impulse Current Imax (10/350μs)12.5ILClass I rating for direct lightning diversion
Corrente di scarica nominale In (8/20μs)50ILClass II rating for induced overvoltage suppression
Livello di protezione della tensione (Su)≤1.5kVClamp surge voltage to safeguard equipment insulation
Tempo di risposta≤25nsFast response to discharge transient surge energy
Short-circuit withstand capacity10ILCoordinate with upstream backup protection device

Meccanico & Parametri Ambientali

ArticoloValoreUnitàOsservazioni
MontaggioMontaggio su guida DINStandard 35mm DIN rail complying with EN 50022
Overall Width72mmOccupies 4 modular pitches (18mm per module)
Materiale dell'alloggiamentoThermoplasticUL94 V0 flame retardant per IEC 60695-11-10
Protezione dall'ingressoIP20Finger-touch safe, solo per installazione in armadio interno
Temperatura operativa-40 ~ +80°CWide ambient temperature for harsh working condition
Segnale remotoDry contact (NA/NC)Contact status change upon SPD failure for remote monitoring
TerminazioneMorsetti a viteAccept 1.5~35mm² copper conductor for reliable wiring

III. Full IPRF1 Series Model List

ModelloPoleMax Impulse CurrentRemote IndicationCodice ordineSistema applicabile
iPRF1 12.5r 1P+N1P+N12.5ILA9L16632Single-phase 230V system
iPRF1 12.5r 3P3P12.5ILA9L16633Three-phase three-wire system
iPRF1 12.5r 3P+N3P+N12.5ILA9L16634Three-phase four-wire 230/400V system
iPRF1 12.5 1P+N1P+N12.5ILNOA9L612501Single-phase without remote monitoring
iPRF1 12.5 3P+N3P+N12.5ILNOA9L612601Three-phase four-wire without remote monitoring
  1. Cross & Legacy Replacement Options
  2. Stesse alternative di serie
Modello originaleModello sostitutivoDescrizione della differenzaApplication Adjustment
iPRF1 12.5r 3P+N(A9L16634)iPRF1 12.5 3P+N(A9L612601)Remote indication removedSmall distribution without remote monitoring
iPRF1 12.5r 3P+N(A9L16634)iPRD1 12.5r 3P+N(A9L16482)Upgraded to iPRD1 series with enhanced reliabilityCommercial buildings requiring superior surge protection
iPRF1 12.5r 3P+N(A9L16634)iPRF1 Master 35r 3P+NImax upgraded to 35kALightning-prone zones & critical industrial facilities
  1. Equivalenti cross-brand
Schneider PartEquivalente ABBEquivalente SiemensPhoenix Contact Equivalent
iPRF1 12.5r 3P+N(A9L16634)OVR T1+2 3N-40-3505SD7440-8VAL-MS 350/3+1-FM
Classe di protezioneT1+T2T1+T2T1+T2
Max Impulse Current12.5IL12.5IL12.5IL
Su≤1,5 kV≤1,5 kV≤1,5 kV
Remote Contact
  1. Recommended Upgrade Models
Vecchio modelloModello di aggiornamentoVantaggi dell'aggiornamentoAmbito di applicazione
iPRF1 12.5r 3P+N(A9L16634)iPRD1 25r 3P+N(A9L16483)Imax raised to 25kA for Class I/II building protectionLarge commercial complex & manufacturing plant
iPRF1 12.5r 3P+N(A9L16634)iPRF1 Master 35r 3P+NImax=35kA with superior surge withstandLightning intensive area, centro dati, Ospedale & key infrastructures
  1. Ambiente applicativo & Project Cases

Recommended Applications ✅

Edifici commerciali: Grade III/IV construction such as office towers, centri commerciali, hotels against indirect lightning & switching overvoltage

Impianti Industriali: Medium/small factory production line control cabinet, protection for PLC, inverter and precision automation equipment

Strutture pubbliche: Scuole, ospedali, libraries to secure stable power supply for public equipment

Piccolo & Medium Data Room: Protect server & network devices from mains transient surge

Locali residenziali: High-rise & villa community to safeguard home appliances & smart home control system

Non-Recommended Applications ❌

Grade I/II key construction (aeroporto, railway hub, large-scale IDC): Requires iPRD1 series with ≥25kA Imax

Open-air exposed installation: IP20 not suitable for outdoor use without extra waterproof enclosure

Grid voltage exceeding 350V AC: Over Uc rating leads to premature SPD breakdown

Installation without qualified earthing: Required earth resistance ≤10Ω for effective surge dissipation

Practical Application Cases

  1. Grade A Office Building: iPRF1 12.5r 3P+N(A9L16634) fitted in floor distribution panels for main power protection. Post-installation before thunderstorm season, IT equipment failure rate dropped by 85%, eliminating office shutdown & data loss caused by lightning strike. Remote contact links with building automation system for instant fault alert and 60% maintenance efficiency improvement.
  2. Auto Component Factory: SPD installed for robot & PLC control power supply. Original frequent unexpected production shutdown from grid fluctuation incurred monthly loss around CNY50,000; after SPD commissioning, downtime reduced by 90% with annual cost saving approx. CNY500,000. ≤25ns quick response prevents servo drive damage from voltage spike and improves machining precision.
  3. High-End Smart Residential Compound: SPD equipped at main distribution room and household panel to protect smart lighting, security & home control devices. Remote signal connects property monitoring platform for 24/7 real-time status check, timely faulty module replacement, improving community power safety & resident satisfaction.
  4. Difetti comuni & Risoluzione dei problemi
Sintomo di guastoRoot CauseRemedial ActionMisure preventive
Remote alarm triggeredSPD module burnout or internal thermal disconnection1. Replace plug-in module after power offAnnual pre-thunderstorm routine inspection; replace SPD after 5 effective surge operations
2. Inspect upstream breaker tripping status
3. Test earth continuity
Module fails to clip onto DIN railImproper DIN rail or broken module latch1. Verify DIN rail complianceHandle module gently during installation, avoid brute force
2. Confirm correct insertion direction
3. Replace damaged SPD unit
Surriscaldamento del terminaleUndersized wire or loose screw1. Replace cable within 1.5~35mm² rangePeriodic thermal check on high-current wiring terminals
2. Retighten screw with 2.5Nm torque
Plug-in module stuckLock unreleased or over-clamped1. Press top release latchDo not over-press module during mounting
2. Wiggle slightly for extraction
Upstream MCCB tripsExcessive surge current or short-circuited SPD1. Check SPD integritySelect matched backup fuse/circuit breaker; regular earthing resistance test
2. Verify matching rating of upstream protection
3. Confirm earth resistance ≤10Ω

VII. Linee guida per la selezione & Regole di riferimento rapido

Quick Selection Mnemonic

12.5kA T1+T2 grade, 3P+N for three-phase grid,

350V rated with remote monitoring ready,

Plug-in structure easy to service, IP20 for indoor cabinet,

Ideal for commercial & factory, Grade III/IV lightning safeguard.

Regole veloci

  1. IPRF1 coding: suffix 12.5r =12.5kA + remote contact; plain 12.5 = no remote indication
  2. Selezione del palo: 1P+N for single phase, 3P for 3P3W, 3P+N for standard 3P4W 400V grid
  3. Order code mapping: A9L16632(1P+N) / A9L16633(3P) / A9L16634(3P+N)
  4. Grade matching: iPRF1 12.5r for III/IV buildings; iPRD1 25r for I/II critical constructions
  5. Installation requirement: Must be paired with upstream backup protection, earthing resistance ≤10Ω