Model A9I48191V120H1P-100A
Model A9I48191V120H1P-100A is the complete order number of a low-voltage electrical product under the Acti9 Series of Schneider Electric. The meaning of each segment of the code and the corresponding product attributes can be explained as follows:
- Model Segment Analysis
- A9: Represents the major product series, namely Schneider’s Acti9 Series. This series is a standardized low-voltage component series launched by Schneider for terminal power distribution, covering miniature circuit breakers, residual current devices, disconnectors, and other products.
- I48: Represents the product type sub-code. In combination with the naming rules of the Acti9 Series, this code usually refers to disconnectors or fuse-disconnectors, which are mainly designed for no-load switching of circuits and power isolation.
- 191: Represents the structural characteristics and accessory configuration code. Different number combinations correspond to different installation methods (per esempio., DIN rail mounting), operation methods (per esempio., handle operation), or auxiliary contact configurations.
- V120: Represents the rated working voltage parameter of the product. Here, `V120` indicates that the rated working voltage of the product is suitable for 120V AC circuits. It should be noted that this voltage class is common in the North American market and is incompatible with the mainstream 220V/380V voltage system in China.
- H1P: Represents the pole number and installation specification of the product. `H1P` means a 1-pole product, suitable for the isolation requirements of single-phase circuits.
- 100UN: Represents the rated working current of the product, i.e., the maximum current that the component can carry stably for a long time is 100A.
- Summary of Core Product Attributes
| Item | Specification Parameter |
| Brand and Series | Schneider Acti9 Series |
| Product Type | 1-pole Disconnector (speculative) |
| Tensione di funzionamento nominale | 120V e (North American voltage class) |
| Corrente di lavoro nominale | 100UN |
| Numero di poli | 1-pole |
| Funzione fondamentale | Circuit isolation, no-load switching |
| Scenario applicativo | Power isolation and maintenance power-off in single-phase 120V power distribution systems in North America |
- Key Precautions
- Voltage Compatibility: The rated voltage of this product is 120V AC. It is strictly prohibited to use it directly in domestic 220V AC circuits, otherwise, it may cause safety accidents such as component burnout and insulation breakdown.
- Functional Positioning: Disconnectors do not have short-circuit protection or overload protection functions and are only used for circuit isolation. They must be used in conjunction with protective components such as circuit breakers.
- Model Verification: To confirm accurate product drawings, installation dimensions, and technical manuals, you can enter the complete order number through Schneider’s official product selection tool or technical support hotline for inquiry.
Domestic Voltage-Adaptable Model Comparison Table for Schneider Acti9 Series 100A Disconnectors
The following is a complete comparison table of domestic adaptable models corresponding to the North American model A9I48191V120H1P-100A and models with different pole numbers of the same specification. These models are suitable for the mainstream 230/400V AC voltage system in China and meet the isolation requirements of single-phase/three-phase power distribution systems.
- Core Model Correspondence
| North American Original Model | Domestic Adaptable Model | Product Series | Numero di poli | Tensione nominale | Corrente nominale | Product Type |
| A9I48191V120H1P-100A | A9S70690 (iSW Series) / A9S66191 | Acti9 | 1P | 230/400V e | 100UN | Miniature Disconnector |
| A9I48191V120H1P-100A | A9S71690 (iSW Series) | Acti9 | 1P | 230/400V e | 100UN | Disconnector with Auxiliary Contacts |
| A9I48191V120H1P-100A | iINT125 1P 100A | Acti9 | 1P | 230/400V e | 100UN | Terminal Disconnector |
- Complete Table of Domestic Adaptable Models with Different Pole Numbers of the Same Specification
| Numero di poli | Domestic Standard Model | Product Series | Tensione nominale | Corrente nominale | Module Width | Caratteristiche principali | Scenari applicativi tipici |
| 1P | A9S70690 (iSW) | Acti9 | 230/400V e | 100UN | 2 moduli (18mm) | Basic disconnector without auxiliary contacts | Isolation of single-phase circuits, such as residential incoming lines and power isolation of small equipment |
| 1P | A9S66191 (iSW) | Acti9 | 230/400V e | 100UN | 2 moduli (18mm) | Standard disconnector with red operating handle | Single-phase power distribution in commercial buildings, maintenance isolation |
| 1P | iINT125 1P 100A | Acti9 | 230/400V e | 100UN | 2 moduli (18mm) | Terminal-specific with optimized operating mechanism | DC-side isolation of photovoltaic systems, front-end of small UPS |
| 2P | A9S70790 (iSW) | Acti9 | 230/400V e | 100UN | 4 moduli (36mm) | 2-pole interlock, simultaneous isolation of live wire and neutral wire | Single-phase 2-pole circuits, such as high-power household appliances like air conditioners and water heaters |
| 2P | A9S66291 (iSW) | Acti9 | 230/400V e | 100UN | 4 moduli (36mm) | Standard 2-pole with red handle | Power isolation of commercial kitchen equipment and small air compressors |
| 3P | A9S70890 (iSW) | Acti9 | 400V e | 100UN | 6 moduli (54mm) | 3-pole interlock, three-phase isolation | Front-end of three-phase equipment such as motors, pompe dell'acqua, and fans |
| 3P | A9S66391 (iSW) | Acti9 | 400V e | 100UN | 6 moduli (54mm) | Standard 3-pole with high short-circuit withstand capacity | Industrial automation equipment, main switch of small power distribution cabinets |
| 4P | A9S70990 (iSW) | Acti9 | 400V e | 100UN | 8 moduli (72mm) | 4-pole interlock, three-phase + neutral wire isolation | UPS input/output in data centers, isolation of medical equipment |
| 4P | A9S66491 (iSW) | Acti9 | 400V e | 100UN | 8 moduli (72mm) | Standard 4-pole with locking device | Three-phase power distribution in special industries such as chemical and metallurgical industries |
- Key Adaptation Instructions
- Voltage Compatibility: All domestic models are suitable for 230/400V AC (50/60Hz), fully compatible with the domestic power grid. It is strictly prohibited to directly use North American 120V models in domestic 220V/380V systems.
- Functional Consistency: All domestic models retain the core functions of disconnectors—no-load circuit switching and power isolation. They do not have short-circuit or overload protection capabilities and must be used in conjunction with circuit breakers.
- Installation Compatibility: All models adopt 35mm DIN standard rail mounting, consistent with the installation method of the original North American model, enabling direct replacement and installation.
- Raccomandazioni per la selezione:
For single-phase circuits, prioritize 1P/2P models.
For three-phase power circuits, prioritize 3P models.
For critical loads requiring simultaneous neutral wire isolation (such as medical equipment and data centers), select 4P models.
For applications requiring remote status monitoring, select models with auxiliary contacts such as A9S71690.
- Supplementary Information
| Item | Detailed Description |
| Certification Standard | Complies with IEC 60947-3 e GB 14048.3 standard, holding domestic CCC certification |
| Operating Life | Mechanical life ≥ 10,000 volte; Electrical life ≥ 1,000 volte (no-load operation) |
| Terminal | Suitable for 16~25mm² copper conductors, recommended torque: 8~10N·m |
| Protection Class | IP20, suitable for installation inside power distribution cabinets |
Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari





















NH42-63-318x560.png)