Azionamento a frequenza variabile Schneider ATV310HU75N4E

Entry-level economical three-phase VFD, version without built-in EMC filter Model Code Explanation ATV310: Altivar Easy 310 serie (simple general-purpose vector type) H: Frame size code U75: Heavy-duty rating 7.5 kW N4: Three-phase 380~460 V E: Senza filtro EMC integrato (Contrast: ATV310HU75N4A with built-in EMC filter) ⚡ Rated Power & Current Heavy Duty (HD): 7.5 kW ...

  • Dettagli del prodotto

Entry-level economical three-phase VFD, version without built-in EMC filter

Spiegazione del codice modello

ATV310: Altivar Easy 310 serie (simple general-purpose vector type)

H: Codice dimensione telaio

U75: Heavy-duty rating 7.5 kW

N4: Three-phase 380~460 V

E: Senza filtro EMC integrato (Contrast: ATV310HU75N4A with built-in EMC filter)

⚡ Rated Power & Attuale

Servizio pesante (HD): 7.5 kW / 10 HP, continuous output 17 UN; 60 s overload 170~200% (25.5 UN)

Dovere normale (ND): 11 kW / 15 HP, continuous output 22.8 UN; 60 s overload 110% (25.1 UN)

Ingresso: Three-phase 380–460 V, 50/60 Hz

Peso netto: 3.7 kg; fan cooling standard, rumore 50 dB(UN)

🧠 Control Modes

Controllo V/F (lineare, quadratic energy-saving curve)

Controllo vettoriale senza sensore (SVC, vettore ad anello aperto)

Frequenza di uscita: 0.5 ~ 400 Hz

Frequenza di commutazione: 2 ~ 12 kHz regolabile, impostazione di fabbrica 4 kHz

Speed regulation range: 1:20 for asynchronous motors

Frenata: ca. 70% braking torque without braking resistor; fino a 150% braking torque with external braking resistor

Slip compensation adjustable

📶 Communication & I/O

Standard Modbus RTU, 2-wire RS485, front RJ45 port

Velocità di trasmissione: 4800/9600/19200/38400 bps, address 1–247

Terminali: 4 digital inputs LI, 1 analog input AI, uscita relè; supports potentiometer, avvio/arresto del terminale, multivelocità, PID (fan & pompa)

🌡️Ambiente & Certificazioni

Pesante: -10 ~ 55 °C senza declassamento; a breve termine max 60 °C

Rivestimento: 3C3/3S2, adatto per armadi elettrici standard e ambienti con poca polvere

Certificazioni: CE, EAC, RoHS, RAEE

Protezione: IP20 (solo per montaggio in armadio)

📌 Applicazioni tipiche

Trasportatori, tifosi, pompe, macchine utensili generali, movimentazione dei materiali, regolazione della velocità per motori asincroni ordinari, adatto per un semplice controllo della velocità e un'alimentazione idrica a pressione costante.

Schneider Elenco dei codici di errore VFD ATV310 (Compatibile con ATV310HU75N4E)

Nota: Codici che iniziano con F = guasto, viaggio bloccato; codici che iniziano con -= richiesta di stato, NON difetti. Ripristino guasto: ciclo di alimentazione / ripristino della tastiera / ripristino della comunicazione

Codice erroreDescrizione del guastoCause comuniAzioni correttive
F001Guasto di precaricaPrecarica del bus CC non riuscita all'accensione, circuito di carica o condensatore del bus difettosoControllare la potenza in ingresso, ponte raddrizzatore, resistenza di carica; il guasto hardware interno richiede una riparazione
F002Errore di identificazione della scheda di potenzaScheda di controllo non corrispondente & scheda di potenza, firmware incompatibileVerifica modello, ricaricare il firmware, sostituire le schede corrispondenti
F003Incompatibilità della scheda di potenzaModello di scheda di potenza errato, pezzi di ricambio mistiSostituirlo con la scheda di alimentazione originale corrispondente
F004Errore di comunicazione seriale internaPerdita di comunicazione tra la scheda di controllo e la scheda di potenza, loose ribbon cableRiposizionare il cavo a nastro; replace board if damaged
F005Errore del codice regionaleVersione regionale del firmware non corrispondenteFlashare il firmware regionale corretto
F006Guasto al circuito di rilevamento della correnteGuasto del circuito di campionamento, sensore Hall danneggiatoInternal hardware fault, inviare per la riparazione
F007Guasto al sensore della temperatura internaSensore di temperatura IGBT rotto o difettosoSe l'allarme si verifica immediatamente all'accensione a freddo, il sensore è quasi sicuramente danneggiato
F008Guasto della CPUAnomalia del controller principale, program runawayCiclo di alimentazione; if ineffective, sostituire la scheda di controllo
F009Over-braking (braking overspeed)Tempo di decelerazione troppo breve, inerzia di carico elevata, circuito frenante difettosoEstendere il tempo di decelerazione; install braking resistor / unità di frenatura; check bus voltage
F010SovracorrenteMotore dell'orologio, cortocircuito del motore, incorrect auto-tune, load surgeCheck mechanical jamming; testare l'isolamento del motore con megger; ridurre la frequenza di commutazione; re-run motor auto-tune
F011Surriscaldamento del VFDCondotto dell'aria ostruito, faulty fan, temperatura ambiente elevata, continuous heavy loadPulire il percorso dell'aria di raffreddamento; ispezionare la ventola; ridurre la temperatura ambiente; operazione di declassamento
F012Sovraccarico del processoPID / soglia di protezione del processo attivata, sovraccarico prolungatoVerificare i parametri di sovraccarico del processo, verificare lo stato del carico
F013Sovraccarico del motoreSovracorrente del motore a lungo termine, soglia della protezione termica impostata troppo bassaControllare se il motore è in stallo; verificare i dati di targa del motore; prolungare il tempo di protezione termica
F014Perdita monofase in uscitaCavo motore rotto, contatto del contattore di uscita bruciato, terminale allentatoControllare il cablaggio di uscita U/V/W, terminali e contattore di uscita
F015Tutte le fasi di uscita sono perseMotore scollegato, tutti i contattori di uscita si aprono, allarme di rilevamento assenza di carico per piccoli motoriControllare il cablaggio del motore; disabilitare il rilevamento della perdita di fase per il test senza carico (parametro 605=00)
F016Sovratensione del bus CCAlta tensione di rete, energia rigenerativa durante la decelerazione, circuito frenante guastoControllare la tensione in ingresso; prolungare il tempo di decelerazione; montare la resistenza di frenatura
F017Perdita di fase in ingressoManca una fase in arrivo, cattivo contatto dell'interruttore, fusibile bruciatoControllare l'alimentazione a monte, interruttore automatico e terminali di ingresso
F018Cortocircuito del motoreCortocircuito tra fasi sull'avvolgimento del motore o sul cavo di alimentazioneScollegare il motore e testare il VFD separatamente; isolamento del motore megger
F019Guasto di terraGuasto a terra del cavo di uscita, rottura dell'isolamento del motore, grandi perdite con più motori paralleliIsolamento del motore e del cavo Megger; installare il reattore di uscita
F020Cortocircuito IGBTRottura del modulo di potenzaNON accendere ripetutamente; inviare per la riparazione e sostituire direttamente il modulo di alimentazione
F021Cortocircuito in uscitaCortocircuito diretto sul lato uscita VFDSpegnere e ispezionare il cavo di alimentazione per eliminare il punto corto
F027Sovratemperatura dell'IGBTTemperatura eccessiva della giunzione IGBT, scarsa dissipazione del caloreDare priorità all'ispezione della ventola di raffreddamento e dei condotti dell'aria, ridurre il carico
F030Sottotensione del bus CCCaduta di tensione di rete, momentanea perdita di potenza, capacità in entrata insufficienteControllare la tensione in ingresso; ispezionare l'interruttore automatico e le connessioni dei terminali; confermare la capacità della rete

Codici di richiesta di stato (Non difetti, Solo indicazione di stato)

CodiceSenso
1Arresto rapido attivato
6Arresto della ruota libera (sosta costiera) attivato
0Freewheel stop complete, stand-by

Supplementary Practical Information

  1. Fault history: Parameters 910~921 to view historical faults and current/voltage readings at fault occurrence
  2. Phase loss detection parameter: 605 output phase loss detection (00=disabled, 01=enabled). Disable temporarily for no-load commissioning, keep enabled for formal operation
  3. Motor auto-tune: Parametro 318. Auto-tune is recommended after motor replacement to reduce F010 and F013 alarms
  4. Ripristina metodi: Keypad reset, digital terminal assigned fault reset, Modbus communication reset, power cycle reset

Complete Model List for Schneider Altivar Easy ATV310 VFD

Nota: Altivar Easy main product is ATV310. Voltaggio: three-phase 380–460 V. Suffix E = without built-in EMC filter, A = with built-in EMC filter. HD = heavy-duty power rating, ND = normal-duty power rating

Spiegazione della codifica del modello

ATV310: Altivar Easy 310 economical general-purpose vector VFD

H: Frame code

Codici di potenza: 037=0.37 kW, 075=0.75 kW, U15=1.5 kW, U22=2,2kW, U30=3kW, U40=4kW, U55=5,5kW, U75=7,5kW, D11=11 kW, D15=15kW, D18=18,5kW, D22=22kW

N4: Three-phase 380~460 V

E: Senza filtro EMC integrato|A: Con filtro EMC integrato

Elenco delle versioni E (Nessun filtro EMC integrato, il tuo ATV310HU75N4E è in questo elenco)

ModelloHD resistenteND Servizio normale
ATV310H037N4E0.37 kW / 0.5 HP0.55 kW / 0.75 HP
ATV310H075N4E0.75 kW / 1 HP1.1 kW / 1.5 HP
ATV310HU15N4E1.5 kW / 2 HP2.2 kW / 3 HP
ATV310HU22N4E2.2 kW / 3 HP3 kW / 4 HP
ATV310HU30N4E3 kW / 4 HP4 kW / 5 HP
ATV310HU40N4E4 kW / 5 HP5.5 kW / 7.5 HP
ATV310HU55N4E5.5 kW / 7.5 HP7.5 kW / 10 HP
ATV310HU75N4E7.5 kW / 10 HP11 kW / 15 HP
ATV310HD11N4E11 kW / 15 HP15 kW / 20 HP
ATV310HD15N4E15 kW / 20 HP18.5 kW / 25 HP
ATV310HD18N4E18.5 kW / 25 HP22 kW / 30 HP
ATV310HD22N4E22 kW / 30 HP30 kW / 40 HP

Elenco delle versioni A (Stesso potere, Filtro EMC integrato, ampiamente utilizzato nei progetti domestici)

Cambia il suffisso E → A, per esempio.

ATV310H037N4A, ATV310H075N4A, ATV310HU15N4A…ATV310HD22N4A

Supplemento: Un altro ATV610 della serie Altivar Easy Family (Gamma Easy ad alta potenza)

Anche l'ATV610 appartiene alla serie Easy, gamma di potenza più ampia, 380–460 V trifase, principalmente per i tifosi & applicazioni di pompe

ATV610D11N4, ATV610D15N4, ATV610D18N4, ATV610D22N4, ATV610D30N4, ATV610D37N4, ATV610D45N4, ATV610D55N4, ATV610D75N4, ATV610D90N4, ATV610C11N4, ATV610C13N4, ATV610C16N4

Parametri generali comuni per l'intera gamma ATV310

Controllare: V/F + SVC vettoriale senza sensore

Comunicazione: Standard Modbus RTU (RJ45)

I/O: 4DI, 1AI, 1 uscita relè

Protezione: IP20, montaggio in armadio

Applicazione: Trasportatori, tifosi, pompe, macchinari OEM generali

Note sulla selezione

  1. Applicazioni pesanti (sollevamento, estrusione, carico d'urto) select according to HD rating; tifosi & pumps with smooth light load can use ND rating
  2. For export CE EMC compliance, select A (EMC integrata); E version requires external EMC filter
  3. Alternativa all'aggiornamento: ATV320 (prestazioni più elevate, encoder support, more expansion cards)

Schneider ATV310 (Altivar Easy) Guida alla selezione delle applicazioni

Precondizione: ATV310 is an economical open-loop vector VFD, no encoder interface, closed-loop vector not supported. Two capacity ratings: HD (Servizio pesante) / ND (Dovere normale). Suffix A=built-in EMC filter, E=no built-in EMC filter, three-phase 380~460 V.

Selection rule: Shock load, frequenti start-stop, stall risk → select HD; tifosi & pumps with smooth light load → ND is acceptable

  1. Rated Current Quick Reference Table (Base Data)
ModelloHD PowerHD Continuous CurrentND PowerND Continuous Current
ATV310H037N40.37 kW2.1 UN0.55 kW2.7 UN
ATV310H075N40.75 kW3.0 UN1.1 kW4.2 UN
ATV310HU15N41.5 kW4.1 UN2.2 kW5.5 UN
ATV310HU22N42.2 kW5.5 UN3.0 kW7.2 UN
ATV310HU30N43.0 kW7.2 UN4.0 kW9.4 UN
ATV310HU40N44.0 kW9.4 UN5.5 kW11.7 UN
ATV310HU55N45.5 kW11.7 UN7.5 kW16.5 UN
ATV310HU75N47.5 kW17.0 UN11 kW22.8 UN
ATV310HD11N411 kW24.0 UN15 kW30.0 UN
ATV310HD15N415 kW30.0 UN18.5 kW37.0 UN
ATV310HD18N418.5 kW37.0 UN22 kW43.0 UN
ATV310HD22N422 kW43.0 UN30 kW57.0 UN
  1. Classificazione delle applicazioni + Selection Scheme + Raccomandazione sugli accessori

Categoria 1: Ventilatori centrifughi & Centrifugal Pumps (Smooth Load, Quadratic Torque, ND Preferred)

Load characteristics: Low starting torque, funzionamento stabile, nessuno shock; adatto per pressione costante PID / flusso d'aria costante, funzionamento continuo e lungo

Selection rule: Selezionare in base alla potenza nominale ND

Suffisso consigliato: A per progetti CE di esportazione (EMC integrata); E per armadi domestici standard con soluzione EMC indipendente

Accessori:

La resistenza di frenatura normalmente non è necessaria (sosta costiera accettabile)

Parametri: Curva quadratica V/F, Abilitazione PID

Limitazione: Aspiratori fumi ad inerzia di grandi dimensioni, ventilatori a tiraggio indotto ad alta temperatura, suggerire una taglia in più, selezionaHD

Esempio: 11 pompa centrifuga kW → ATV310HU75N4A (ND=11 kW)

Categoria 2: Trasportatori generali, Linee di cintura, Tavoli a rulli (Coppia costante, Avvio-arresto intermittente, Preferibile HD)

Load characteristics: Coppia costante, moderata resistenza all'avviamento, frequenti start-stop, shock occasionale da inceppamento del materiale

Selection rule: Seleziona rigorosamente in base alla classificazione HD, corrente nominale del motore ≤ corrente VFD HD

Accessori:

Decelerazione lunga, cinghia ad alta inerzia: aggiungere resistenza di frenatura

Il controllo multivelocità utilizza direttamente i terminali DI integrati, nessuna scheda di espansione richiesta

Limitazione: Posizionamento ad alta velocità, high-precision synchronization not suitable for ATV310, use ATV320 instead

Esempio: 7.5 kW belt conveyor → ATV310HU75N4A (HD=7.5 kW)

Categoria 3: Mixing Tanks, Miscelatori (High Starting Torque, Carico pesante)

Load characteristics: High starting torque, high resistance from tank media, high stall risk, coppia costante

Selection rule: HD selection, reserve 1.1~1.2 safety margin; motor rated current ≤ 90% of VFD HD current

Accessori: Braking resistor for emergency stop; motor auto-tune recommended

High viscosity mixing: select one power size up

Esempio: 5.5 kW mixing motor → Prefer ATV310HU75N4 (HD 7.5 kW) for margin

Categoria 4: Screw Pumps, Gear Pumps, Positive Displacement Pumps (Coppia costante)

Load characteristics: Medium starting torque, pressure fluctuation, dry running prohibited

Selection rule: HD for normal operation; upsizing for heavy pressure fluctuation & frequenti start-stop

Accessori: PID constant pressure, add pressure feedback AI

Esempio: 4 kW screw pump → ATV310HU40N4 (HD 4 kW)

Categoria 5: Macchine per la lavorazione del legno, Smerigliatrici, General Machine Tool Spindles (Continuous Constant Torque)

Load characteristics: Continuous cutting, fluttuazione del carico, stable torque requirement

Selection rule: HD selection; upsizing for heavy cutting shock

❌ Non applicabile: Spindle positioning, rigid tapping, closed-loop control → ATV310 has no encoder support, use ATV320

Categoria 6: Sollevamento, Hoist, Winch, Hydraulic Main Pump ( ATV310 NOT Recommended)

Avviso importante: ATV310 is economical open-loop vector VFD, no brake logic, no torque verification, no safety functions. NOT allowed for lifting applications. Hoisting duty requires ATV320 + safety relay or dedicated hoist VFD.

Categoria 7: Cooling Tower Fans, Roof Fans, Exhaust Fans (Light Load Quadratic Torque)

Selezione: ND rating, best cost performance

Nota: Ambient temperature below -10 °C requires cabinet heater, VFD derating applies

Cabinet for outdoor installation prefers A version built-in EMC to avoid interference

Categoria 8: Multi-motor Parallel Drive (Synchronous drag, multiple small motors)

Selezione: Sum of all motor rated currents matched against HD current; motor auto-tune must be disabled, run in V/F mode

Accessori: Fit thermal relay for each motor for individual overload protection; output reactor recommended

  1. Suffix A / E Selection Judgment (EMC)
  2. ATV310…N4A (Filtro EMC integrato)

Adatto: EU CE export, control cabinet close to sensors, strumenti, PLC communication cables, high EMC requirement

  1. ATV310…N4E (Nessun filtro EMC integrato)

Adatto: Standard domestic factory, power cables separated from signal wires, project procures separate external EMC filter; prezzo più basso

Rischio: Direct operation may interfere with sensors, weighing instruments, Comunicazione RS485

  1. Ambient Derating Rules

Ambient temperature 45~55 °C: HD rating no derating; >55 °C derating mandatory

Altitudine >1000 M: declassare 4% per ulteriore 1000 M; ATV310 not recommended above 2000 M

Polvere, gas corrosivo: Enclosed cabinet + air conditioning required; standard ATV310 is 3C3 coated

  1. When to Upgrade from ATV310 to ATV320

Select ATV320 if any condition below applies:

  1. Encoder closed-loop control, high precision speed / posizionamento / synchronization required
  2. Safe torque off STO safety function required
  3. Multiple expansion cards needed (encoder card, Profinet/EtherNet/IP Ethernet card)
  4. Sollevamento, ascensore, hoist loads
  5. Severe dynamic shock, fast torque response required
  6. Quick Selection Summary Table
Tipo di applicazioneTorque CharacteristicRecommended RatingRecommended SuffixBraking Resistor Suggested
Ventilatore centrifugo / PompaQuadratic TorqueNDUN (Esportare) / E (Domestico)NO
Belt Conveyor, Roller TableCoppia costanteHDUN / EYes for high inertia
Mixing, High Viscosity BlendingCoppia costante, High Starting TorqueHD + Upsize One StepUNYes for emergency stop
Positive Displacement Pump (Screw Pump)Coppia costanteHDUN / EOpzionale
General Machine Tool SpindleConstant Torque with FluctuationHDUNNO
Multi-motor Parallel V/F DriveCombinatoTotal Current Match HDUNOpzionale