Convertitore inverter Schneider Electric ATV71HD15N4Z - Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari

Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Di Contatto |

Convertitore inverter Schneider Electric ATV71HD15N4Z - Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari

inverter solare/contatore elettrico/elettrico/

Convertitore inverter Schneider Electric ATV71HD15N4Z

This is a 15 kW, 380–480 V three-phase high-performance general-purpose inverter drive from Schneider Electric’s Altivar 71 serie. It features a built-in Category A EMC filter, no graphical terminal, and integrated CANopen & Comunicazione Modbus. The rated output current is 39 A at 480 V / 48 A at 380 V. It uses flux vector ...

  • Dettagli del prodotto

This is a 15 kW, 380–480 V three-phase high-performance general-purpose inverter drive from Schneider Electric’s Altivar 71 serie. It features a built-in Category A EMC filter, no graphical terminal, and integrated CANopen & Comunicazione Modbus. The rated output current is 39 A at 480 V / 48 A at 380 V. It uses flux vector control technology, suitable for precise speed and torque control of fans, pompe, compressori, and complex industrial machinery. Classe di protezione: IP20. Montaggio standard: 35 Guida DIN da mm.

  1. Spiegazione del modello
Parte del modelloDescrizione
ATVSerie di prodotti: Schneider Altivar inverter drives
71Series ID: Altivar 71 high-performance general-purpose drive (contro. ATV61 dedicated to fans & pompe)
HDValutazione & application: HD = Heavy Duty (15 kW and above), for heavy-duty loads
15Potenza nominale: 15 kW (20 HP)
N4Voltage class: three-phase 380–480 V (-15% A +10%), 50/60 Hz
ZOption code: no graphical terminal, built-in Category A EMC filter, integrated CANopen & ModBus
  1. Specifiche principali

Dati elettrici

ArticoloValoreNote
Potenza nominale15 kW (20 HP)For three-phase asynchronous motors
Tensione in ingressoThree-phase 380–480 VRange: -15% A +10%
Input frequency50/60 HzRange: ±5%
Corrente di uscita nominale39 UN (480 V) / 48 UN (380 V)Continuous operational current
Tensione di uscita0 to input voltagePWM, three-phase AC
Frequenza di uscita0.1–599 HzAdjustable range
Switching frequency1–16 kHzNominal 4 kHz, adjustable for cooling/noise
Metodo di controlloFlux vector control (with/without sensor)Open loop 1:100, closed loop 1:1000
Capacità di sovraccarico150% rated current for 60 SFor starting and shock loads
Efficienzaca. 97%High efficiency, progettazione a risparmio energetico

Meccanico & Dati ambientali

ArticoloValoreNote
Grado di protezioneIP20A prova di dita, suitable for cabinet mounting
Montaggio35 Montaggio su guida DIN da mm o con vitiStandard industrial mounting
Dimensioni (L×A×P)ca. 150×380×210 mmCompatto, space‑saving
Pesoca. 22 kgEasy handling and installation
Temperatura operativa-10 °C ~ +40 °CDerate above 40 °C
Temperatura di conservazione-25 °C ~ +70 °CDesign ad alta affidabilità
Umidità relativa5%–95%Non‑condensing
Altitudine≤ 1000 MDerate above 1000 M

Comunicazione & Interface Data

ArticoloConfigurazioneNote
Standard communicationCANopen, ModBus RTUIntegrato
Optional communicationProfibus DP, DeviceNet, Ethernet/IPVia communication cards
Ingressi digitali6 configurable24 A DC, PNP/NPN selectable
Ingressi analogici2 configurable0–10 V or 4–20 mA
Digital outputs2 relè + 2 transistorRelay rating: 250 V e / 5 UN
Analog outputs10–10 V or 4–20 mA
  1. Caratteristiche
  2. High-performance control: flux vector control provides precise speed and torque control. Speed accuracy: ±0.5% open loop, ±0.01% closed loop.
  3. Risparmio energetico: Built-in ENA (Energy Adaptation) system automatically optimizes V/F pattern and adjusts output according to load; energy savings up to 30%.
  4. Filtro EMC integrato: Category A filter as standard, riduce le interferenze elettromagnetiche, complies with EN 55011.
  5. Protezione completa:

Protezione del motore: sovracorrente, sovraccarico, overheat, perdita di fase, rotore bloccato, guasto a terra

Drive protection: sovratensione, sottotensione, overheat, cortocircuito, parameter fault

Mains protection: surge suppression, voltage fluctuation tolerance

  1. Flexible control functions:

Multi-speed setting (fino a 16 speeds)

PID closed-loop regulation (constant pressure water supply, constant tension control)

Flying Start: smooth start while motor is rotating

Brake unit management: built-in brake unit for fast stopping

  1. Communication integration: CANopen & Modbus RTU as standard, seamless connection to PLC, HMI, and automation devices.
  2. Guida alla selezione

Applicazioni tipiche

Industrial machinery: compressori, trasportatori, miscelatori, centrifughe

Building services: large fans, pompe, HVAC systems

Movimentazione dei materiali: gru, ascensori, trasportatori

Applications requiring precise speed control and high dynamic response

Environments with strict EMC requirements

Selection Principles

  1. Load matching:

Continuous loads (tifosi, pompe): select 1:1 rated power

Intermittent loads (compressori, gru): 1.1–1.2 times power margin

Shock loads (frantoi, presses): select HD series for 150% sovraccarico

  1. Voltage and power:

Supply: three-phase 380–480 V

Motor power ≤ 15 kW, current ≤ 39 UN (480 V) / 48 UN (380 V)

For higher power: ATV71HD 22 kW, 30 kW, ecc.

  1. Controllare & comunicazione:

Standard configuration for general use

Advanced communication (Profinet, EtherCAT) via option cards

Graphical terminal: models ending in N4 (per esempio., ATV71HD15N4)

  1. Ambiente:

Derate 1% per °C above 40 °C

Derate 1% per 100 m sopra 1000 M

Additional protection for humid or corrosive environments

  1. Note di installazione
  2. Pre-installation:

Verify model and inspect physical condition

Confirm input voltage matches mains supply

Prepare 35 mm DIN rail or mounting plate

Ensure sufficient cooling space in cabinet

  1. Installation procedure:

Mount vertically on 35 Guida DIN da mm

Keep at least 100 mm clearance for cooling

Circuito principale: L1/L2/L3 = input, U/V/W = motor

Circuito di controllo: wire DI/DO/AIO and communication per diagram

Main terminal torque: M6 approx. 8 N·m, cable 16–35 mm²

  1. Sicurezza:

Isolate and verify voltage-free before work

Separate power and control wiring

Use shielded motor cable (massimo. 50 m shielded, 100 m unshielded)

Resistenza di terra ≤ 4 OH

Check motor and protection parameters before power-up

  1. Messa in servizio & manutenzione:

Perform motor auto-tuning at first power-up

Test start/stop, speed adjustment, and protection

Inspect fan and capacitors annually

Keep unit clean and dust‑free

  1. Modelli alternativi

Same‑series Alternatives

ModelloDifferenzaApplicazione
ATV71HD15N4With graphical terminalLocal setting and monitoring
ATV71HU15N4ZStandard duty (sotto 15 kW)Light loads, no heavy‑duty performance
ATV71HD22N4Z22 kWHigher power requirements
ATV71HD15Y4Z525–690 VHigh‑voltage mains

Upgrade Alternatives

ModelloAggiornamentoApplicazione
ATV930D15N4ATV900 series, prestazioni più elevateComplex motion control, alta precisione
ATV630D15N4Fan/pump dedicatedHVAC optimized for energy saving
ATV71HD15N4FEnhanced filterStricter EMC requirements

Budget Alternatives

ModelloDifferenzaApplicazione
ATV71HU15N4ZStandard duty, no HD performanceStable loads, low dynamic response
ATV61HD15N4ZFan/pump seriesBasic fan/pump control, conveniente

The Schneider Electric ATV71HD15N4Z is a high-performance, high-reliability general-purpose inverter drive. With flux vector control, built-in EMC filter, complete protection, and flexible communication, it is an ideal choice for 15 kW applications in industrial automation. Selezione corretta, installazione, and maintenance ensure long‑term reliable operation and deliver precise, efficient, energy‑saving speed control for various machinery.

Standard Selection Procedure for Schneider Inverter Drives

(Industrial general‑purpose, per le vendite / preventivo / progetto)

  1. Definire l'applicazione & Serie

General industrial machinery: compressori, trasportatori, mixers → ATV71 series (alte prestazioni, high dynamics)

Tifosi / Pumps / HVAC: aria condizionata, water supply, ventilation → ATV61 series (dedicated algorithm, risparmio energetico)

Complex motion control: gru, ascensori, precision machinery → ATV900 series (high‑end, multi‑axis synchronization)

  1. Determinare la categoria di carico

Continuous load (AC‑1): riscaldatori, lighting → 1:1 power selection

Carico del motore (AC‑3): squirrel‑cage motor DOL → motor current ≤ drive rated current

Shock load (AC-4): frantoi, presses → select HD series for 150% sovraccarico

  1. Calculate Current & Valutazione
  2. Read motor nameplate: energia / voltage → rated current
  3. Apply 1.1–1.25 safety margin (spunto, servizio continuo)
  4. Select rated power / current from Schneider catalog

Esempio: 380 V three‑phase 15 kW motor ≈ 30 A → ATV71HD15N4Z (48 UN) is suitable.

  1. Select Voltage Class

200–240 V single/three‑phase: small equipment

380–480 V three‑phase: industrial standard

525–690 V three‑phase: high‑voltage systems

  1. Define Control & Comunicazione
  2. Metodo di controllo:

General: standard flux vector control

Alta precisione: closed‑loop vector with encoder

  1. Comunicazione:

Standard: ModBus RTU

Opzionale: CANopen, Profibus DP, Ethernet/IP

  1. HMI:

No terminal: model ends with Z

Graphical terminal: model ends with N4

  1. Special Functios

Filtro EMC: Category A (built‑in) or B (opzionale)

Brake unit: built‑in (standard) or external (alta potenza)

Sicurezza: STO (Safe Torque Off) available

Extended I/O via option cards

  1. Ambiente & Montaggio

Temperatura > 40 °C, altitude > 1000 m → derate or upsize

Protezione: IP20 for cabinet, IP54+ for outdoor

Montaggio: 35 mm DIN rail or screws, vertical for cooling

  1. Final Check: Modello + Certificates
  2. Conferma il modello completo: series–power–voltage–option

Esempio: ATV71HD15N4Z

  1. Verify certificates: CE, UL, CCC, RoHS
  2. Confirm options: communication card, braking resistor, filter, ecc.

Complete Guide to International Brand Alternatives

for Schneider ATV71HD15N4Z

Executive Summary: Per 15 kW 380–480 V three‑phase high‑performance applications, the following international brand alternatives offer flux vector control, built‑in EMC filter, ≥150% overload, and standard communication. They can directly replace the ATV71HD15N4Z in industrial machinery, tifosi, pompe, and material handling.

  1. Alternativa ABB

Modello consigliato: ACS580-01-033A-4

Specifiche principali

ArticoloValoreComparison to ATV71HD15N4Z
Potenza nominale15 kW (20 HP)Stesso
Tensione in ingressoThree‑phase 380–480 V (-15% A +10%)Stesso
Corrente di uscita nominale33 UN (HD)Slightly lower than 39 A/48 A
Sovraccarico150% per 60 SStesso
ControllareDTC Direct Torque ControlBetter dynamics than flux vector
ComunicazioneModbus RTU standard; Profibus DP, EtherNet/IP optionalStesso
Filtro EMCBuilt‑in Category AStesso
ProtezioneIP20Stesso
MontaggioWall / cabinetStesso

Key advantages: ABB patented DTC; open loop speed range 1:1000, torque response < 10 SM.

Applicazioni: Compressori, trasportatori, mixers requiring high dynamics and precise torque control.

Backup Model: ACS550-01-033A-4

Cost‑effective alternative, funzioni semplificate, suitable for stable loads like fans and pumps.

  1. Siemens Alternative

Modello consigliato: SINAMICS G120C 6SL3210-1KE23-2UF1 (Compatto)

Specifiche principali

ArticoloValoreComparison to ATV71HD15N4Z
Potenza nominale15 kW (HD) / 18.5 kW (LO)Stesso / higher
Tensione in ingressoThree‑phase 380–480 V (+10% A -20%)Wider range
Corrente di uscita nominale38 UN (HD)Almost identical to 39 UN
Sovraccarico200% per 3 S + 150% per 57 SBetter
ControllareSensorless vector controlStesso
ComunicazioneProfibus DP standard; PROFINET, EtherNet/IP optionalStesso
Filtro EMCBuilt‑in C3 filterBetter than Category A
ProtezioneIP20Stesso
Montaggio35 Guida DIN da mm / vitiStesso

Key advantages: Siemens SINAMICS platform, seamless TIA Portal integration, STO built‑in.

Applicazioni: Lines, material handling integrated with Siemens PLC.

Backup Model: SINAMICS G120 6SL3224-0BE31-1UA0 (Modulare)

Progettazione modulare, expandable I/O, comunicazione, and safety for complex systems.

  1. Danfoss Alternative

Modello consigliato: VLT AutomationDrive FC302P15KT5E20H2BGXXXXSXXXXAXBXCXXXXDX (131F9966)

Specifiche principali

ArticoloValoreComparison to ATV71HD15N4Z
Potenza nominale15 kW (HD) / 18.5 kW (LO)Stesso / higher
Tensione in ingressoThree‑phase 380–500 VWider range
Corrente di uscita nominale32 UN (HD) / 37.5 UN (LO)Slightly lower
Sovraccarico160% per 60 S (ogni 10 min)Better
ControllareSensorless vector controlStesso
ComunicazioneModBus RTU / CANopen standard; Profibus DP, EtherNet/IP optionalStesso
Filtro EMCBuilt‑in C3 filterBetter than Category A
ProtezioneIP20Stesso
MontaggioWall mounting, back‑channel cooling30% space saving

Key advantages: Patented back‑channel cooling, compatto, low noise ≤ 65 dB.

Applicazioni: HVAC fans, pompe, and noise‑sensitive industrial machines.

  1. Rockwell Automazione (Allen‑Bradley) Alternative

Modello consigliato: PowerFlex 755 20G1ANC302JA0NNNNN

Specifiche principali

ArticoloValoreComparison to ATV71HD15N4Z
Potenza nominale15 kW (20 HP)Stesso
Tensione in ingressoThree‑phase 380–480 V (±10%)Stesso
Corrente di uscita nominale32 UN (HD)Slightly lower
Sovraccarico150% per 60 SStesso
ControllareTotalForce sensorless vectorStesso
ComunicazioneEtherNet/IP standard; Profibus DP, DeviceNet optionalAdvanced Ethernet
Filtro EMCBuilt‑inStesso
ProtezioneIP20Stesso
MontaggioWall / cabinetStesso

Key advantages: TotalForce platform, seamless Logix integration, advanced diagnostics.

Applicazioni: North American equipment, automotive lines, macchine per l'imballaggio.

Backup Model: PowerFlex 525 25B-D030N114

Compatto, cost‑effective for space‑limited general applications.

  1. Other International Brands

Eaton: SVX9000-4T0032

Specs: 15 kW, 380–480 V, 32 UN, 150%/60 S, built‑in EMC, IP20, Modbus/CANopen.

Utilizzo: High‑reliability applications: gru, compressori.

Vacon: NXC0320T4H0SSSA1A2

Specs: 15 kW, 380–480 V, 32 UN, 150%/60 S, sensorless vector, built‑in EMC, IP20.

Utilizzo: General industrial machinery, multi‑PLC systems.

  1. Replacement Selection Guide
RequisitoModello consigliatoMotivo
High dynamics / precise torqueABB ACS580-01-033A-4DTC, risposta rapida
Siemens system integrationSiemens G120C / G120TIA Portal, STO built‑in
Basso rumore / space savingDanfoss FC302Back‑channel cooling, compatto
Rockwell system integrationPowerFlex 755TotalForce, Logix compatible
Cost‑effective general useABB ACS550 / PowerFlex 525Semplificato, economico
Wide voltage fluctuationSiemens G120C+10% A -20% tolleranza

All international alternatives meet the performance requirements for 15 kW three‑phase applications. Each brand offers strengths in control, integration, cooling, and features. Selection should prioritize system compatibility, tipo di carico, environment, and budget to ensure plug‑and‑play replacement.

All recommended models include a built‑in EMC filter, standard communication, and full protection, allowing direct replacement of the ATV71HD15N4Z without extra basic components.

Prec:

Prossimo:

Lascia una risposta