Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Di Contatto |

Schneider Electric NSX250N‑3P‑160A - Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari

interruttore automatico/

Schneider Electric NSX250N‑3P‑160A

This is a Schneider Electric ComPacT NSX series molded case circuit breaker (MCCB) for power distribution protection. New standard order number: C25N3TM160 Obsolete old order number: LV431832 Compliant with IEC 60947‑2 and GB/T 14048.2 standard. Basic Rated Core Parameters Item Value Type Low‑voltage MCCB for power distribution protection Frame rating 250A Poles 3P (3 poli, ...

  • Dettagli del prodotto

This is a Schneider Electric ComPacT NSX series interruttore automatico scatolato (MCCB) for power distribution protection.

New standard order number: C25N3TM160

Obsolete old order number: LV431832

Compliant with IEC 60947‑2 and GB/T 14048.2 standard.

  1. Basic Rated Core Parameters
ItemValore
TipoLow‑voltage MCCB for power distribution protection
Frame rating250UN
Poles3P (3 poli, all protected)
Rated current In160UN (continuous at 40℃)
Rated operational voltage Ue690V CA 50/60 Hz, suitable for 380V/400V/415V systems
Rated insulation voltage Ui800V e
Rated impulse withstand voltage Uimp8kV
Frequenza50/60Hz
Utilization categoryType A (no short‑time delay, general distribution)
Isolation functionCertified isolating function per IEC 60947‑2
  1. Short‑Circuit Breaking Capacity
System VoltageRated ultimate shortircuit breaking capacity IcuRated service shortircuit breaking capacity Ics
415V e50IL50IL (100% Icu, reusable after breaking)
500V e36IL36IL
690V e10IL10IL

Rated short‑time withstand current Icw (1s): 12kA at 415V AC

  1. TMD Thermal‑Magnetic Release Characteristics

Standard TMD thermal‑magnetic release, LI protection (long‑time overload + instantaneous short‑circuit).

  1. Long‑time overload thermal protection

Ir setting range: 0.7–1×In (112A–160A)

Characteristic: 120–400s at 1.5×Ir; ≤15s at 6×Ir (standard inverse time)

  1. Short‑circuit instantaneous magnetic protection

Instantaneous current Ii: fixed at 1250A

Operating time: ≤20ms

  1. Mechanical & Installation Parameters
ItemValore
Dimensioni (W×H×D)105mm × 161mm × 86mm
Standard mounting centersVertical 125mm × Horizontal 35mm
MountingFixed, front connected; orizzontale/verticale, no derating
Wiring capacityUp to 70mm² copper cable / busbar
Mechanical endurance20,000 operazioni
Electrical endurance10,000 operations at 440V AC, In
Ingress protectionIP40 (body), IP54 (panel‑mounted)
Impact resistanceIK07
Net weightApprox. 2.4kg
  1. Environmental & Compliance Parameters

Ambient temperature: -25℃ ~ +70 ℃; no derating below 40℃

Altitudine: 0–2000m without derating

Grado di inquinamento: 3

Overvoltage category: II

Certifications: CCC, CE, EAC, Marine, ecc.

Accessory slots: 5 standard slots for auxiliary, alarm, shunt, undervoltage release, ecc.

  1. Expansion & Compatibility

Can be fitted with Vigi earth‑leakage modules

Compatible with motor operators for remote control

Can add interlock, position indicator, padlock devices

Top/bottom feed both allowed without performance derating

Replacement & Note sulla selezione

  1. Old type LV431832 is discontinued; use C25N3TM160 instead.
  2. For electronic release (adjustable short delay / earth fault), upgrade to NSX250N with MicroLogic (2.2/5.0).
  3. Breaking ratings: H (70IL), S (100IL), based on short‑circuit calculation.
  4. Competitors: ABB Tmax T2, Siemens 3VT250, suitable for cross‑brand replacement.

NSX250N‑3P‑160A Direct Replacement Solutions

Core Matching Rules (100% match required)

Frame rating: 250UN (do NOT downgrade to 160A frame)

Poles: 3P

Corrente nominale: 160UN

Potere di interruzione: ≥50kA at 415V AC

Release type: thermal‑magnetic (LI characteristic)

Mounting: fixed front connection, matching panel holes

  1. Recommended Replacements

Scenario 1: Import Brand Direct Replacement

ABB Tmax XT3N250 TMD160/1600 FF 3P

Order No.: 1SDA068266R1

Match: 100%

Frame 250A, 3P, 160UN, TMG thermal‑magnetic

Icu=50kA, Ics=50kA at 415V AC

Identical dimensions and mounting holes

Full accessory compatibility

Application: foreign‑funded plants, export equipment, on‑site repair

Siemens 3VC250N TMA160 3P

Order No.: 3VC2316‑2DA33‑0AA0

Match: 98%

Frame 250A, 3P, 160UN, TMA thermal‑magnetic

50kA at 415V AC

Highly compatible dimensions

Application: Siemens low‑voltage systems

Scenario 2: Domestic High‑Cost‑Performance Replacement

Changshu Switch CM3‑250H/3300 160A

Match: 99%

Frame 250A, 3P, 160UN, distribution type thermal‑magnetic

Icu=50kA at 415V AC

Compliant with IEC 60947‑2 / GB 14048.2

Application: industriale, building distribution, domestic projects

Chint NM8‑250N/3P 160A

Match: 95%

Frame 250A, 3P, 160UN, thermal‑magnetic

50kA at 415V AC

Application: civil construction, general distribution

  1. Dimensioni & Parameters Comparison
ModelloDimensioni (W×H×D)Mounting CentersIcu (415V)ReleaseFrame
NSX250N‑3P‑160A105×161×86mm125mm×35mm50ILTMD250UN
ABB XT3N250 3P 160A105×161×86mm125mm×35mm50ILTMG250UN
Siemens 3VC250N 3P 160A105×160×85mm125mm×35mm50ILTMA250UN
CM3‑250H 3P 160A108×162×86mm125mm×35mm50ILThermal‑magnetic250UN

> Nota: ABB XT3N250 matches dimensions and holes 100% – best direct replacement.

  1. Safety Rules for Replacement
  2. No frame downgrade: Do NOT use 160A frame breakers (per esempio., ABB T2N, NSX160).
  3. Breaking capacity ≥50kA: Do NOT use 36kA / 25kA models.
  4. Release matching: Use distribution‑type thermal‑magnetic only.
  5. Accessory compatibility: Match auxiliary, shunt, sottotensione, earth‑leakage modules.
  6. Final Selection Guide

Direct replacement, import, no cabinet modification: ABB XT3N250 TMD160/1600 FF 3P

New project, domestic approval, cost‑effective: Changshu CM3‑250H/3300 160A

Siemens system replacement: Siemens 3VC250N TMA160 3P

Prec:

Lascia una risposta

Lasciate un messaggio