Schneider EOCRSSD-30S Digital Motor Protector - Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari

Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Di Contatto |

Schneider EOCRSSD-30S Digital Motor Protector - Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari

elettrico/

Schneider EOCRSSD-30S Digital Motor Protector

Model Code Interpretation Code Segment Description EOCR Series logo, motor protection relay series under Schneider (Former SAMWHA Korea) SS Basic series code, economical electronic overcurrent relay platform D Function upgrade code, Digital display version, different from LED indicator type of traditional SS series 30 Current specification code, rated protection current range: 3-30UN, built-in through-type CT for ...

  • Dettagli del prodotto

Interpretazione del codice modello

Segmento di codiceDescrizione
EOCRSeries logo, motor protection relay series under Schneider (Former SAMWHA Korea)
SSBasic series code, economical electronic overcurrent relay platform
DFunction upgrade code, Digital display version, different from LED indicator type of traditional SS series
30Current specification code, rated protection current range: 3-30UN, built-in through-type CT for direct wiring
SControl power supply code: universal wide voltage 24-240V AC/DC; Type W is dedicated for 380-440V AC

Posizionamento centrale:

EOCRSSD-30S is a compact digital comprehensive motor protection relay, featuring three core protections: sovraccarico, phase loss and stall. It is applicable for motors with current 3-30A and compatible with 24-240V wide-voltage control power supply.

  1. Parametri delle specifiche principali
CategoriaSpecifiche dettagliateOsservazioni
Parametri di base
Numero d'ordineEOCRSSD-30S (Schneider SKU: 0015874)Standard universal model worldwide
Tipo di protezioneElectronic overcurrent relay / Motor protectorReplace combination of traditional thermal relay and ammeter
Installazione35Montaggio su guida DIN da mm / Panel mountingStruttura compatta, salvaspazio
Dimensione (L×A×P)56mm×78mm×120mmFully compatible with installation size of EOCR-SS series
Temperatura operativa-20℃ ~ 60℃Adapt to temperature difference changes in industrial environment
Specifiche elettriche
Current Protection Range3-30UN (direct wiring)External CT is required for current over 60A
Controllare l'alimentazione24-240V CA/CC (50/60Hz)Wide voltage design, fit for various control systems
Working Frequency50/60HzUniversal power frequency for global use
Output Contacts1NO + 1NC passive contacts95-96 (NC), 97-98 (NO)
Capacità di contattoCA 250 V/5 A, DC 30V/5AMeet demands of conventional control circuits
Funzioni di protezione
Protezione da sovraccaricoRegolabile (0.1~100s), support I²t inverse time characteristicSet via O-TIME parameter
Protezione dalla perdita di faseQuick action within 4 secondiTrigger when three-phase unbalance degree>20%
Stall ProtectionAdjustable startup delay (D-TIME), minimum 0.2s quick trippingSuitable for instantaneous protection during motor startup
Funzione di visualizzazione7-segment LED digital tubeReal-time display of operating current and fault code
Reset ModeRipristino manuale (RESET button) / Electric resetEasy recovery after troubleshooting
Precisione & Affidabilità
Measuring Accuracy±1%Higher than traditional thermal relay (±10%)
Tempo di rispostaminimo. 0.2S (protezione dallo stallo)Effectively prevent motor damage
Fault RecordCheck the latest 3 fault recordsConvenient for quick fault location
Classe di isolamentoClasse IIHigh safety protection level
  1. Difetti comuni & Maintenance Solutions

3.1 Fault Codes & Risoluzione dei problemi

Codice erroreFault TypePossibili causeSoluzioni
O-COverload Tripping1. Excessive motor load1. Check load and eliminate mechanical jamming
2. Too small O-TIME setting2. Appropriately increase O-TIME value
3. Abnormal power supply voltage3. Measure three-phase voltage to ensure balance
P-PPhase Loss / Open Phase1. Broken or loose power wire1. Check circuit connection and fasten terminals
2. Burned contactor contacts2. Replace faulty contactor contacts
3. Motor winding failure3. Measure insulation resistance of motor winding
S-CStall / Blockage1. Instant stall during motor startup1. Inspect mechanical transmission system
2. Too short D-TIME setting2. Appropriately extend D-TIME value
3. Stuck mechanical load3. Remove load jamming failure
Nessuna visualizzazionePower Failure1. Control power disconnected1. Check power wiring
2. Power voltage out of range2. Measure input voltage (24-240V)
3. Blown internal fuse3. Replace internal fuse
Abnormal DisplayElectromagnetic Interference1. Close to high-power inverter / electric welder1. Keep away from interference sources or add shielding measures
2. Cablaggio allentato2. Inspect and fasten all wiring
3. Firmware error3. Restore device to factory settings

3.2 Daily Maintenance Schedule

Ciclo di manutenzioneMaintenance ItemsPunti Operativi
QuotidianoIspezione visivaClean panel and heat dissipation holes, check normal LED display
SettimanaleIspezione del cablaggioCheck loose terminals and oxidation phenomenon
MensileParameter VerificationConfirm O-TIME and D-TIME conform to motor rated values
TrimestraleProva di funzionalitàSimulate overload and phase loss faults to verify protection accuracy
YearlyComprehensive InspectionCheck aging of internal components, update firmware if necessary
  1. Full EOCRSSD Series Model List

The EOCRSSD series has 3 basic models covering current range 0.5-60A to meet protection demands of motors with different power.

ModelloCurrent Protection RangeControllare l'alimentazioneCaratteristiche principaliPotenza motore applicabile (380V)
EOCRSSD-05S0.5-6UN24-240V CA/CCSpecial for low current, direct wiring0.18-3kW
EOCRSSD-30S3-30UN24-240V CA/CCGeneral medium current type, direct wiring1.5-15kW
EOCRSSD-60S5-60UN24-240V CA/CCGeneral high current type, direct wiring (External CT required above 60A)3-30kW

Nota: The whole series supports overload, phase loss and stall protection; independent adjustable startup delay (D-Time) and overload action time (O-Time); LED digital display for operating current and fault causes.

  1. Cross-brand Product Comparison
Comparison ItemsSchneider EOCRSSD-30SSiemens 3RB2026-1KB0ABB CM-MSS.61SOmron K8DS-PH1
Intervallo corrente3-30UN2.5-32UN0.1-40UN3-30UN
Controllare l'alimentazione24-240V CA/CC24-240V CA/CC24-240V CA/CC24-240V CA/CC
Funzioni di protezioneSovraccarico, Phase Loss, StallSovraccarico, Phase Loss, StallSovraccarico, Phase Loss, Stall, Phase UnbalanceSovraccarico, Phase Loss, Stall
Modalità di visualizzazione7-segment LED digital tubeLED indicator lightDisplay digitaleLED indicator light
Output Contacts1NA+1NC1NA+1NC1NA+1NC1NA+1NC
Grado di precisione±1%±2%±1%±2%
Dimensioni di installazione56×78×120mm55×78×118mm56×78×120mm55×78×118mm
Fascia di prezzoMedio (Di 370 RMB)Alto (Di 500 RMB)Alto (Di 480 RMB)Medio (Di 350 RMB)
Vantaggi fondamentaliIntuitive digital display, fault record, 1:1 replacement for SS seriesBrand premium, excellent system integrationPhase unbalance protection, alta precisioneConveniente, velocità di risposta rapida
  1. Air Shipment Compliance & Informazioni sulla certificazione

6.1 Air Shipment Compliance Judgment

Categoria di prodotto: Electrical and electronic equipment (No built-in lithium battery / super capacitor)

Numero ONU: Non richiesto (Non-dangerous goods)

Shipping Restrictions: No special restrictions, deliver as general cargo

Packaging Requirement: Adopt anti-static packaging to avoid static damage to internal components during transportation

6.2 Informazioni sulla certificazione

Certification TypeNorma di certificazioneApplicable ScopeRequisiti chiave
Certificazione CEIN 60947-4-1 (Sicurezza elettrica)EU MarketComply with Low Voltage Directive (LVD) and EMC Directive
IN 61000-6-2 (EMC Immunity)
Certificazione ULUL 508 (Industrial Control Equipment)North America MarketMeet North American electrical safety standards
CSA CertificationCSA C22.2 No.14 (Control Equipment)Canada MarketConform to Canadian safety standards
IEC CertificationCEI 60947-4-1Global MarketComply with standards of International Electrotechnical Commission

Nota: CE marks and certification numbers are marked on product body and outer package. Technical documents shall include test reports, risk assessment reports and Declaration of Conformity (DoC), which shall be kept for at least 10 anni.

  1. Formula di selezione & Quick Memorization Rules

7.1 Formula di selezione

Calculate motor current first, match EOCRSSD properly;

05 stands for 0.5-6A, 30 covers 3-30A;

60 reaches 60A, match external CT for higher current;

Select S/W according to control power, S means 24-240 ampia tensione;

Three core protections: sovraccarico, phase loss and stall;

Easy fault checking via digital display, convenient DIN rail installation.

7.2 Quick Memorization Rules

Corrispondenza attuale: Rated motor current shall be within 30%-80% of protector range, avoid boundary value affecting accuracy

Voltage Selection: Prioritize Type S (24-240V CA/CC) control power for stronger compatibility

Impostazione dei parametri:

O-TIME: Impostato 10-20 seconds when current is 1.2 times motor rated current

D-TIME: Set as motor startup time plus 2 secondi

Replacement Rule: Realize 1:1 direct replacement for traditional EOCR-SS series and thermal relays without changing installation size and wiring

  1. Applicabile & Scenari inapplicabili

Scenari applicabili

  1. General Industrial Motors: Protection for water pumps, tifosi, compressors and other common equipment
  2. Piccole linee di produzione: Single motor control loop requiring visualized fault display
  3. Renovation Projects: Replace traditional thermal relays to improve protection precision and convenience
  4. Harsh Working Environment: Temperature range -20℃~60℃, suitable for most industrial sites
  5. Multi-voltage System: 24-240V wide voltage adaptation, fit for transnational equipment and complex power supply environment

Scenari inapplicabili

  1. High-precision Control: Intelligent control system needing 4-20mA analog output or communication function (Recommend EOCR-E series)
  2. Extra-high Current Motor: Current over 60A without space for external CT installation (Recommend EOCR-3DM2 series)
  3. Special Protection Demand: Occasions requiring earth protection, leakage protection or phase sequence protection (Recommend EOCR-DS1 series)
  4. Explosion-proof Environment: Hazardous areas needing explosion-proof certification (Choose dedicated explosion-proof protectors)

Full Series Model List of Schneider EOCR Digital Motor Protectors

  1. Series Classification Overview

Schneider EOCR digital motor protectors are divided into three categories by function positioning: Tipo economico, Multifunctional Digital Type and Intelligent Type, covering current range 0.5-800A to meet various industrial demands.

  1. Economical Digital Protectors (EOCR-SS/SSD Series)

2.1 EOCR-SS Series (LED Indication)

ModelloIntervallo correnteControllare il potereOrdine n.Caratteristiche principaliApplicable Power (380V)
EOCR-SS05S0.5-6UN24-240V CA/CC15872Overload/Phase Loss/Stall protection, Indicazione LED0.18-3kW
EOCR-SS30S3-30UN24-240V CA/CC15873Same protection functions1.5-15kW
EOCR-SS60S5-60UN24-240V CA/CC15874Same protection functions3-30kW
EOCR-SS05W0.5-6UN380-440V e15875Dedicated 380V control power0.18-3kW
EOCR-SS30W3-30UN380-440V e15876Dedicated 380V control power1.5-15kW
EOCR-SS60W5-60UN380-440V e15877Dedicated 380V control power3-30kW

2.2 EOCR-SSD Series (Digital Display Upgraded Version)

ModelloIntervallo correnteControllare il potereOrdine n.Caratteristiche principaliApplicable Power (380V)
EOCRSSD-05S0.5-6UN24-240V CA/CC15878Dual digital & LED display, fault record, inverter optimized0.18-3kW
EOCRSSD-30S3-30UN24-240V CA/CC15879Same functions1.5-15kW
EOCRSSD-60S5-60UN24-240V CA/CC15880Same functions3-30kW
EOCRSSD-05W0.5-6UN380-440V e15881380V dedicated, dual display0.18-3kW
EOCRSSD-30W3-30UN380-440V e15882380V dedicated, dual display1.5-15kW
EOCRSSD-60W5-60UN380-440V e15883380V dedicated, dual display3-30kW
  1. Multifunctional Digital Protectors (EOCR-E Series)

3.1 EOCR-3DE/FDE Series (Basic Digital Type)

ModelloIntervallo correnteControllare il potereTipo di cablaggioCaratteristiche principaliScenari applicabili
EOCR-3DE-050.5-6UN24-240V CA/CCWindow typeOverload/Phase Loss/Stall/Reverse Phase/Unbalance protection, pre-alarmMotori industriali generali
EOCR-3DE-303-30UN24-240V CA/CCWindow typeSame functionsMotori industriali generali
EOCR-3DE-605-60UN24-240V CA/CCWindow typeSame functionsMotori industriali generali
EOCR-FDE-050.5-6UN24-240V CA/CCFeed-through typeSame as 3DE series with different wiringSpace-limited installation
EOCR-FDE-303-30UN24-240V CA/CCFeed-through typeSame as 3DE series with different wiringSpace-limited installation
EOCR-FDE-605-60UN24-240V CA/CCFeed-through typeSame as 3DE series with different wiringSpace-limited installation

3.2 EOCR-3EZ/FEZ Series (With Earth Fault Protection)

ModelloIntervallo correnteControllare il potereTipo di cablaggioCaratteristiche principaliScenari applicabili
EOCR-3EZ-050.5-6UN24-240V CA/CCWindow type3DE full functions + adjustable earth fault protection (30mA-1A)Equipment requiring earth protection
EOCR-3EZ-303-30UN24-240V CA/CCWindow typeSame functionsEquipment requiring earth protection
EOCR-3EZ-805-80UN24-240V CA/CCWindow typeSame functionsEquipment requiring earth protection
EOCR-FEZ-050.5-6UN24-240V CA/CCFeed-through typeSame as 3EZ seriesSpace-limited installation + earth protection
EOCR-FEZ-303-30UN24-240V CA/CCFeed-through typeSame as 3EZ seriesSpace-limited installation + earth protection
EOCR-FEZ-805-80UN24-240V CA/CCFeed-through typeSame as 3EZ seriesSpace-limited installation + earth protection

3.3 EOCR-3E420/FE420 Series (With 4-20mA Output)

ModelloIntervallo correnteControllare il potereTipo di cablaggioCaratteristiche principaliScenari applicabili
EOCR-3E420-050.5-6UN24-240V CA/CCWindow type3DE functions + 4-20mA analog outputRemote monitoring system
EOCR-3E420-303-30UN24-240V CA/CCWindow typeSame functionsRemote monitoring system
EOCR-3E420-605-60UN24-240V CA/CCWindow typeSame functionsRemote monitoring system
EOCR-FE420-050.5-6UN24-240V CA/CCFeed-through typeSame as 3E420 seriesSpace-limited + monitoraggio remoto
EOCR-FE420-303-30UN24-240V CA/CCFeed-through typeSame as 3E420 seriesSpace-limited + monitoraggio remoto
EOCR-FE420-605-60UN24-240V CA/CCFeed-through typeSame as 3E420 seriesSpace-limited + monitoraggio remoto
  1. Intelligent Protectors (EOCR-3DM2/FDM2/3MZ2 Series)

4.1 EOCR-3DM2 Series (Window Type)

ModelloIntervallo correnteControllare il potereCaratteristiche principaliFunzione di comunicazioneScenari applicabili
EOCR-3DM2-WRDB0.5-80UN24A DCProtezione completa + digital display + fault record + load selectionRS-485 ModbusDC control system
EOCR-3DM2-WRDU0.5-80UN100-240V CA/CCProtezione completa + digital display + fault record + load selectionRS-485 ModbusAC & DC universal system
EOCR-3DM2-WRDBHZ0.5-80UN24A DCWith harmonic suppression functionRS-485 ModbusFrequency conversion drive system
EOCR-3DM2-WRDUHZ0.5-80UN100-240V CA/CCWith harmonic suppression functionRS-485 ModbusFrequency conversion drive system

4.2 EOCR-FDM2 Series (Feed-through Type)

ModelloIntervallo correnteControllare il potereCaratteristiche principaliFunzione di comunicazioneScenari applicabili
EOCR-FDM2-FRDB0.5-80UN24A DCProtezione completa + digital display + fault record + load selectionRS-485 ModbusDC control system
EOCR-FDM2-FRDU0.5-80UN100-240V CA/CCProtezione completa + digital display + fault record + load selectionRS-485 ModbusAC & DC universal system
EOCR-FDM2-FRDBHZ0.5-80UN24A DCWith harmonic suppression functionRS-485 ModbusFrequency conversion drive system
EOCR-FDM2-FRDUHZ0.5-80UN100-240V CA/CCWith harmonic suppression functionRS-485 ModbusFrequency conversion drive system

4.3 EOCR-3MZ2 Series (Tipo di terminale, External CT Required)

ModelloIntervallo correnteControllare il potereCaratteristiche principaliFunzione di comunicazioneScenari applicabili
EOCR-3MZ2-TRDB0.5-800UN (External CT)24A DCProtezione completa + digital display + fault record + load selectionRS-485 ModbusHigh current motor
EOCR-3MZ2-TRDU0.5-800UN (External CT)100-240V CA/CCProtezione completa + digital display + fault record + load selectionRS-485 ModbusHigh current motor
EOCR-3MZ2-TRDBHZ0.5-800UN (External CT)24A DCWith harmonic suppression functionRS-485 ModbusHigh current frequency conversion motor
EOCR-3MZ2-TRDUHZ0.5-800UN (External CT)100-240V CA/CCWith harmonic suppression functionRS-485 ModbusHigh current frequency conversion motor
  1. Special Function Protectors

5.1 EOCR-DS/DS3 Series (Economical Digital Display Type)

ModelloIntervallo correnteControllare il potereCaratteristiche principaliScenari applicabili
EOCRDS-05S0.5-6UN24-240V CA/CCOverload/Phase Loss/Stall protection, digital displayBasic digital display demand
EOCRDS-30S3-30UN24-240V CA/CCOverload/Phase Loss/Stall protection, digital displayBasic digital display demand
EOCRDS-60S5-60UN24-240V CA/CCOverload/Phase Loss/Stall protection, digital displayBasic digital display demand
EOCRDS3-05S0.5-6UN24-240V CA/CCUpgraded version with additional phase unbalance protectionBasic display + protezione dagli squilibri
EOCRDS3-30S3-30UN24-240V CA/CCUpgraded version with additional phase unbalance protectionBasic display + protezione dagli squilibri
EOCRDS3-60S5-60UN24-240V CA/CCUpgraded version with additional phase unbalance protectionBasic display + protezione dagli squilibri

5.2 EOCR-PMZ/PFZ Series (Power Monitoring Type)

ModelloIntervallo correnteControllare il potereCaratteristiche principaliFunzione di comunicazioneScenari applicabili
EOCR-PMZ-050.5-6UN24-240V CA/CCProtezione completa + power monitoring + energy meteringRS-485 ModbusEnergy consumption monitoring system
EOCR-PMZ-303-30UN24-240V CA/CCProtezione completa + power monitoring + energy meteringRS-485 ModbusEnergy consumption monitoring system
EOCR-PMZ-805-80UN24-240V CA/CCProtezione completa + power monitoring + energy meteringRS-485 ModbusEnergy consumption monitoring system
EOCR-PFZ-050.5-6UN24-240V CA/CCFeed-through type, same functions as PMZ seriesRS-485 ModbusEnergy monitoring + limited space
EOCR-PFZ-303-30UN24-240V CA/CCFeed-through type, same functions as PMZ seriesRS-485 ModbusEnergy monitoring + limited space
EOCR-PFZ-805-80UN24-240V CA/CCFeed-through type, same functions as PMZ seriesRS-485 ModbusEnergy monitoring + limited space

5.3 EOCR-DGT Series (Tipo di protezione dalle perdite)

ModelloIntervallo correnteLeakage Protection RangeControllare il potereCaratteristiche principaliScenari applicabili
EOCR-DGT-050.5-6UN30mA-1A24-240V CA/CCPerdita + Sovraccarico + Phase Loss + Reverse Phase + Unbalance protectionEquipment in humid environment
EOCR-DGT-303-30UN30mA-1A24-240V CA/CCFull combined protectionEquipment in humid environment
EOCR-DGT-605-60UN30mA-1A24-240V CA/CCFull combined protectionEquipment in humid environment
EOCR-DGT-805-80UN30mA-1A24-240V CA/CCFull combined protectionEquipment in humid environment
  1. Quick Memorization of Model Naming Rules
  2. Prefisso: EOCR= Schneider motor protection relay series mark
  3. Codice serie:

SS/SSD: Economical type (SSD with digital display)

3DE/FDE/3EZ/FEZ/3E420/FE420: Multifunctional digital type

3DM2/FDM2/3MZ2: Tipo intelligente (3MZ2 needs external CT)

DS/DS3: Simple digital display type

PMZ/PFZ: Power monitoring type

DGT: Leakage protection type

  1. Codice attuale: 05(0.5-6UN), 30(3-30UN), 60(5-60UN), 80(5-80UN)
  2. Power Supply Code: S(24-240V CA/CC), W(380V e), B(24VCC), U(100-240V CA/CC)
  3. Modalità di cablaggio: W(Window), F(Feed-through), T(Terminal type)
  4. Funzione speciale: HZ(Harmonic suppression), 420(4-20mA output)
  5. Quick Selection Table by Functional Demand
Functional DemandSerie consigliataVantaggi fondamentaliMax Current
Protezione di base & basso costoEOCR-SS/SSDConveniente, facile installazione60UN
Protezione di base + digital displayEOCRSSD/DSVisualized fault checking60UN
Protezione completa + earth fault protectionEOCR-3EZ/FEZAnti-leakage, high safety level80UN
Monitoraggio remoto + analog signalEOCR-3E420/FE4204-20mA signal output, easy system integration60UN
Intelligent control + comunicazioneEOCR-3DM2/FDM2Modbus remote control80UN
High current motor protectionEOCR-3MZ2Match external CT, cover 0.5-800A800UN
Energy consumption monitoring + protezioneEOCR-PMZ/PFZPower statistics and energy-saving analysis80UN
Protezione dalle perdite + full combined protectionEOCR-DGTProtezione contro le perdite integrata80UN

Prec:

Lascia una risposta

Lasciate un messaggio