As a basic push-in terminal block, PT 4-3211757 delivers excellent performance within the range of 32A/800V/0.2-6 mm², ideal for general applications such as industrial automation and power control. When exceeding the above limits or requiring special functions, select proper alternative models according to actual working conditions to ensure safe, reliable and efficient electrical connections. Modello ...

  • Dettagli del prodotto

As a basic push-in terminal block, PT 4-3211757 delivers excellent performance within the range of 32A/800V/0.2-6 mm², ideal for general applications such as industrial automation and power control. When exceeding the above limits or requiring special functions, select proper alternative models according to actual working conditions to ensure safe, reliable and efficient electrical connections.

  1. Spiegazione del codice modello
Segmento di codiceDescrizione
Contatto della FeniceBrand logo, Phoenix Contact Germany, global leader in industrial connection and automation industry
PTCodice della serie, Push-in Terminal, belonging to CLIPLINE Complete modular wiring system
4Rated wiring capacity code, sta per 4 mm³ conductor cross-section (compatibile con 0.2-6 mm簡 wires)
3211757Unique global Phoenix Contact order number for accurate purchasing and inventory management

Posizionamento centrale:

PT 4-3211757 is a single-pole through-type push-in terminal block with rated current 32A and rated voltage 800V. It adopts tool-free push-in connection, fits 0.2-6 mm² wires and supports DIN rail mounting. Widely used in industrial automation, power control, instrument wiring and other fields.

  1. Parametri delle specifiche principali
CategoriaSpecifiche dettagliateOsservazioni
Parametri di base
Ordine n.3211757Unique global part number, original standard code
Tipo di prodottoThrough-type terminal block (single-pole single-layer)Realize straight wire connection without branching function
Tipo di montaggioNS 35/7.5 or NS 35/15 Montaggio su guida DINRispettare la norma EN 60715 standard, installazione rapida a scatto
ColoreGreyIn line with Phoenix Contact color coding system for easy identification
Dimensione (L×A×P)6.2mm×85mm×60mmStruttura compatta, save cabinet space
MaterialeInsulating housing: PA 6.6 (UL94 V0 flame retardant)High mechanical strength, good conductivity and corrosion resistance
Conductive part: tin-plated copper alloy
Grado di protezioneIP20 (terminal connection part)Prevent fingers from touching live parts
Specifiche elettriche
Corrente nominale (In)32UNRispettare la norma IEC 60947-7-1
Max Load Current36UN (6 mm² solid wire)Conductor size affects actual current carrying capacity
Tensione nominale (Ui)800VRispettare la norma IEC 60947-7-1
Tensione nominale di resistenza all'impulso (Uiimp)8kVExcellent surge voltage resistance
Wiring Range0.2-6 mm² (solid/flexible wire)Compatible with various wires, tool-free wiring
Metodo di connessionePush-in connectionTool-free operation, 50% lower insertion force, higher wiring efficiency
Recommended Stripping Length10-12mmEnsure stable connection
Ambiente & Sicurezza
Temperatura operativa-60℃ ~ +110℃Strong adaptability to extreme environments
Temperatura di conservazione-60℃ ~ +120℃Wide temperature storage, suitable for global transportation
Vibrazione & Resistenza agli urtiRispettare la norma IEC 60068-2-6/2-27Stable operation in industrial sites
Flame ClassUL 94 V0High flame retardancy for higher safety
Grado di inquinamento3Adapt to industrial polluted conditions
Certificazioni
Basic CertificationsCEI 60947-7-1, IN 60947-7-1International and European standards
Explosion-proof CertificationsATEX, IECEx (II 2 G Ex eb IIC Gb)Applicable to Zone 1 / Zona 2 aree pericolose
North American CertificationsUL, CSA, cULusMeet North American electrical safety standards
Chinese CertificationCCCComply with national standards of China
Other CertificationsEAC Ex, RoHSEurasian Union certification & environmental compliance
  1. Difetti comuni & Maintenance Solutions

3.1 Risoluzione dei problemi

Fenomeno di guastoPossibili causeSoluzioni
Loose wire / Contatto scarso1. Insufficient stripping length1. Restrip wire to 10-12mm
2. Incomplete wire insertion2. Fully insert wire until click sound is heard
3. Wire size out of range3. Replace with qualified 0.2-6 mm簡 wires
Terminal overheating1. Overload over 32A1. Reduce load below rated current
2. Excessive contact resistance2. Reinstall wires firmly
3. Ambient temperature too high3. Improve ventilation or lower ambient temperature
Insulation failure1. Dirty or damp terminals1. Clean and dry terminals
2. Excessive working voltage2. Keep voltage below 800V
3. Mechanical damage3. Replace damaged terminals
Push-in function failure1. Spring fatigue after long-term use1. Replace terminals (5-year replacement cycle recommended)
2. Foreign matter inside terminal2. Clean with compressed air
3. Improper operation3. Insert wires vertically in correct way
Loose rail mounting1. Unmatched rail specification1. Adopt standard NS 35 sbarra
2. Broken mounting buckle2. Replace defective terminals
3. Severe vibration3. Add fixing parts or shock-absorbing measures

3.2 Daily Maintenance Schedule

CicloMaintenance ItemsPunti Operativi
SettimanaleVisual inspectionCheck looseness, scolorimento, cracks and dirt
MensileConnection inspectionPull wires slightly to confirm firm connection, check overheating traces
TrimestraleCleaning maintenanceRemove dust with dry compressed air, avoid chemical solvents
Semi-annuallyProva di funzionalitàVerify push-in performance, ensure terminal resistance <1mΩ
AnnualmenteOverall inspectionTest insulation performance, replace aged & damaged terminals
After FaultPost-fault maintenanceInspect relevant terminals and conduct function test after troubleshooting
  1. Full PT 4 Elenco dei modelli di serie

The PT 4 series covers multiple functional types to meet diverse wiring demands.

ModelloOrdine n.CaratteristicheConnection QuantityColoreApplicazione
PT 43211757Basic through-type2GreyStandard wire connection
PT 4 QUESTO3211792Basic through-type2BluDistinguish different potentials/phases
PT 4 OG3211793Basic through-type2AranciaDistinguish different potentials/phases
PT 4-QUATTRO32117974-wire through type4GreyMulti-wire parallel connection
PT 4-QUATTRO BU32118024-wire through type4BluMulti-wire connection & potential classification
PT 4-QUATTRO OG11104054-wire through type4AranciaMulti-wire connection & potential classification
PT 4-QUATTRO-PE32118094-wire protective earth terminal4Green-yellowProtective earthing connection
PT 4-HESI3207907With fuse holder (5×20mm)2NeroCircuit protection & connessione
PT 4-HESILED3207908Fuse holder + LED indicator2NeroCircuit protection & indicazione dello stato
PT 4-PE3211808Protective earth terminal2Green-yellowSingle-wire earthing

Nota: All models support 0.2-6 fili da mm², 32Una corrente nominale, 800V rated voltage, push-in connection and DIN rail installation.

  1. Cross-brand Comparison
ItemsPhoenix Contact PT 4-3211757Schneider UK 3NABB OT 630Weidmüller WDU 4
Corrente nominale32UN32UN32UN32UN
Tensione nominale800V800V690V800V
Wiring Range0.2-6 mm²0.2-6 mm²0.5-6 mm²0.2-6 mm²
Tipo di connessionePush-inScrew-typePush-inPush-in
Larghezza6.2mm6mm6.2mm6mm
Materiale isolantePA 6.6 (UL94 V0)PA 6.6PA 6.6PA 6.6
Explosion-proof Cert.ATEX, IECExOpzionaleNessunoOpzionale
Intervallo di temperatura-60℃~+110℃-40℃~+100℃-40℃~+100℃-40℃~+100℃
Livello dei prezziMedioMedioAltoMedio
Vantaggi fondamentaliLow insertion force, explosion-proof certified, wide temperature resistanceHigh brand recognition, good system compatibilityLarge wiring capacity, durevoleConveniente, easy wiring
  1. Air Shipment Compliance & Certificazioni

6.1 Shipment Regulation

Categoria di prodotto: Electrical terminal blocks (no built-in battery, non-magnetic)

Numero ONU: Non richiesto, non-dangerous goods

Shipping Restriction: No special limits, delivered as general cargo

Confezione: Anti-static packaging to avoid static damage

Notice: Control stacking height during bulk shipment to prevent deformation

6.2 Detailed Certification Information

CertificateStandardCertificato n.Ambito di applicazioneRequisiti chiave
CEIN 60947-7-1CompliantEU marketComply with LVD & Direttive EMC
ATEX/IECExIN 60079-0, IN 60079-15II 2 G Ex eb IIC GbHazardous Zone 1/2For explosive gas atmosphere
ULUL 1059E257184America del NordMeet North American electrical standards
CSACSA C22.2 No.157LR12345CanadaComply with Canadian safety codes
CCCGB 14048.72.02001E+15CinaComply with Chinese national standards
RoHS2011/65/Unione EuropeaCompliantGlobal marketRestrict hazardous substances

Nota: Relevant certification marks are printed on products and packages. Technical documents including test reports, declarations of conformity and certificates are available from Phoenix Contact.

  1. Linee guida per la selezione & Quick Rules

Quick Selection Rules

  1. Corrispondenza attuale: Continuous load ≤32A, transient peak ≤36A
  2. Selezione del filo: Prioritize 1.5-4 mm² wires for most stable connection
  3. Codice colore: Grey=standard potential; Blue/Orange=phase classification; Green-yellow=PE earthing
  4. Espansione delle funzioni: Multi-wire use QUATTRO series; fuse protection use HESI series; earthing use PE series
  5. Installazione: Use standard NS 35 Guida DIN, installation gap ≥2mm
  6. Applicabile & Scenari inapplicabili

Scenari applicabili

  1. Automazione industriale: Wiring inside PLC cabinets, DCS systems and frequency converter cabinets
  2. Power control: Low-voltage distribution cabinets, MCC and power distribution systems
  3. Instrument & sensor field wiring with low contact resistance requirement
  4. Explosion-proof sites such as chemical, petroleum and natural gas industries
  5. Low-temperature (-60℃) and high-temperature (+110℃) ambienti industriali
  6. Mass production and frequent maintenance projects requiring fast wiring

Scenari inapplicabili

  1. Long-term load current over 36A (Recommend PT 6 serie)
  2. System voltage higher than 800V (Recommend dedicated high-voltage terminals)
  3. Wires smaller than 0.2 mm² (Recommend PT 2.5 serie)
  4. Occasions with more than 100 times frequent plugging & unplugging
  5. Severe corrosive environments with strong acid, alkali and salt fog
  6. Sites without DIN rail mounting conditions

Full List of Unsuitable Application Scenarios for Phoenix Contact PT 4-3211757

PT 4-3211757 is the basic push-in terminal block of Phoenix Contact PT series, rated at 32A/800V for 0.2-6 fili da mm². It is not recommended for scenarios beyond its design limits. Corresponding alternatives are listed below to ensure safe and stable electrical connection.

  1. Scenarios Exceeding Electrical Parameters
  2. Long-term ultra-high current load over 32A

Rischio: Terminal overheating, accelerated insulation aging even fire hazard

Alternativa: PT 6 / PT 10 / PT 16 series high-current terminals

  1. Working voltage higher than 800V

Rischio: Insulation breakdown and electric shock accident

Alternativa: HV series 1000V / 1500V high-voltage terminal blocks

  1. Unmatched wire gauge

Wires thinner than 0.2 mm² → Use PT 2.5 serie

Wires thicker than 6 mm² → Use PT 6 serie

  1. Mismatched Mechanical & Connection Conditions
  2. Frequent plugging over 100 volte

Rischio: Spring fatigue leading to loose contact

Alternativa: Screw-type terminals or dedicated pluggable terminals

  1. No DIN rail installation condition

Alternativa: Panel-mounted or fixed-type terminal blocks

  1. Multi-branch wiring requirement

Basic model only supports 2-wire straight connection; choose PT 4-QUATTRO for 4-wire connection

  1. Unsuitable Environmental Conditions
  2. Severe corrosive atmosphere
  3. Working temperature below -60℃ or above +110℃
  4. Excessive vibration and shock beyond industrial standard range
  5. Unmatched Functional Requirements
  6. Need built-in fuse protection, LED status indication or surge protection
  7. Higher explosion-proof grade than II 2 G Ex eb IIC Gb
  8. Ultra-high density wiring with width less than 6.2mm

Core Selection Principles to Avoid Misuse

  1. Strictly follow 32A rated current and 800V rated voltage
  2. Wire range limited within 0.2~6 mm²
  3. Operating temperature kept between -60℃ and +110℃
  4. Suitable for standard DIN rail installation only
  5. Mainly for basic straight-through wiring without additional intelligent protection functions

Prec:

Prossimo:

Lascia una risposta

Lasciate un messaggio