Serie: TeSys Deca (formerly TeSys D) 3-contattore CA a polo
✅ Model Code Explanation
LC1D: TeSys Deca contactor series
150: AC-3, 440V rated current 150 UN
F: Coil AC110 V
7: 50/60 Hz universale
✅ Specifiche principali
Contatti principali: 3P 3NO (three normally open)
Categoria di utilizzo: AC-3 (motore), AC-1 (carico resistivo), AC-4 (inching)
Motor power at 400 V: 75 kW
Bobina: AC110 V, 50/60 Hz
Terminali: Morsetti con morsetto a vite
Contatti ausiliari incorporati: Standard 1NO + 1NC
Protezione: Front face IP20
Temperatura ambiente: -40 ~ +60 °C (declassamento richiesto sopra 60 °C)
Montaggio: Guida DIN / base plate screw mounting
Standard: IEC60947-4-1, CCC, CE, UL, CSA, EAC, UKCA
✅ Lifecycle & Sostituzione
Stato: Fine vita (EOL), end of production: 31 Dec 2026
Official recommended upgrade replacement: LC1D150AEHE
LC1D150AEHE: TeSys Deca Advanced, 3P 150 UN, wide-voltage coil 48–130 V AC/DC, plug-in wiring, dimensionalmente compatibile, control circuit programming unchanged
If strict AC110 V identical specification replacement is required, check stock availability of LC1D150F7, or select domestic equivalent 150 A contactors.
✅ Compatible Accessories (Common for this series)
Blocchi di contatti ausiliari: LADN (LADN11, LADN22, ecc.)
Timer modules: LADT
Interblocco meccanico: LAD9R1
Soppressore di picchi della bobina: LADRC (for AC coil absorption)
Relè di sovraccarico termico abbinato: LRD485 (adatto per 150 UN)
✅ Dimensions (L × A × P)
132 × 196 × 130 mm
Domestic Equivalent List for LC1D150 (AC-3 @400V, 150 UN, 75 kW, 3P)
Nota sulla selezione: CJX2-150 has the closest outline, mounting dimension and accessory system to LC1D150; coil voltage available in AC110 V to perfectly match your original F7 (AC110 V) circuito; all with CCC certification, GB/T14048.4 / IEC60947-4-1
Livello 1 Marche (Widely used in engineering, prestazioni affidabili)
- CHINT NC2-150 / CJX2-150
NC2: CHINT main heavy-current series; CJX2-150 adopts TeSys D imitation structure, mounting hole spacing close to LC1D150
AC-3 @400 V: 150 UN, 75 kW; coil voltages AC110 V, 220 V, 380 V opzionale
Ausiliario: Nessun contatto ausiliario integrato; F4 auxiliary blocks and pneumatic timers can be added, same operation as Schneider Serie LAD
Matching thermal relay: NR2-200 (covers 150 UN)
- DELIXI CJX2-150
Largest market inventory, convenient for replacement; same structure as TeSys D
AC-3 150 UN / 75 kW; terminali a vite; compatible with F4 auxiliary blocks, pneumatic timers and mechanical interlocks
- TENGEN CJX2-150
Stessa specifica, consistent accessory system; widely adopted by panel builders for LC1D replacement
Old model CJT1-150: outdated structure, large size, not recommended for new project replacement
- People Electric CJX2-150
Consistent rating, AC-3 150 UN, 75 kW; complete coil voltage options, also used for export projects
Livello 2 / Direct Replacement Specialized Models
BOWO BWDC1-150F: Specially designed to match LC1D series, nearly identical dimensions, AC-3 150 UN, AC110 V coil optional, clearly marked silver contact configuration, suitable for bulk replacement
Other Wenzhou manufacturers: CJX2-150 (Jubang, Nader NDC2-150, ecc.). Nader is high-end domestic brand with longer electrical life and better surge resistance, priced higher than CHINT and DELIXI
⚠️ Critical Selection Notes
- CJX2-150 (115~170 A frame) has NO built-in auxiliary contacts!
LC1D150 comes with factory 1NO+1NC; domestic CJX2-150 has no onboard auxiliary contacts. F4-11 (1NA+1NC) deve essere ordinato separatamente, otherwise control circuit feedback signal will be missing — this is the most common pitfall during replacement.
- Dimensions are NOT 100% identical
CJX2-150 shares similar overall outline, with minor deviations on mounting pitch and busbar width. For direct in-cabinet drop-in replacement, BWDC1-150F is preferred, or verify cutout dimensions in advance.
- CJT1-150 is not recommended for direct replacement
Old-style design, bulky, incompatible with F4 auxiliary blocks. Only for maintenance of legacy equipment of the same model, not for LC1D substitution.
- Coil designation example: CJX2-150 AC110 V corresponds to LC1D150F7 (AC110 V 50/60 Hz)
✅ Quick Recommendation
Standard panel build, sensibile ai costi: DELIXI CJX2-150 + F4-11 auxiliary block
Prioritize form-fit interchange with Schneider: BOWO BWDC1-150F AC110 V
High-end domestic, lunga durata: Nader NDC2-150
✅ Advantages of Schneider TeSys D (LC1D)
- Convenient wiring and assembly
Auxiliary contacts mounted on top; LADN auxiliary blocks, timers and surge modules are easy to fit. Many frame sizes come with built-in 1NO+1NC (including LC1D150), no extra auxiliary block required. Reversing and star-delta assemblies are simple, widely adopted by panel shops.
- Strong supply chain, stock availability and mature replacement ecosystem
Large domestic stock volume; mature CJX2 domestic substitute system for maintenance and spare parts. Dominant in HVAC, pompa, general motor control cabinets and building distribution.
- Tolerant coil voltage margin
Better tolerance for fluctuating grid voltage and voltage drop on site; wide-voltage coil options abundant.
- Intuitive model naming: LC1Dxx easy to identify, rich Chinese datasheets and selection tools.
Limitazioni:
No native integration advantage with Siemens PLC / TIA Portal ecosystem;
Higher cost for high-current frames; legacy TeSys D models gradually phased out (per esempio. your LC1D150F7).
✅ Advantages of Siemens SIRIUS 3RT
- Robust German design for harsh operating conditions
Solid construction, proven performance in heavy industry, minerario, rail and frequent AC-4 inching applications; conservative overcurrent and short-time withstand design for impact loads.
- Best compatibility with Siemens PLC / TIA full system
3RT2 paired with 3RU thermal relays and 3RV motor protectors under unified SIRIUS platform. Native EPLAN macros and TIA device library support, simplified BOM and documentation for standardized machines and panels.
- Flexible modular expansion
Side-mounted auxiliary contacts allowing stacking of multiple feedback and diagnostic modules, ideal for systems requiring numerous feedback signals and safety circuits.
Limitazioni:
Side-mounted auxiliary contacts are awkward for wiring when cabinet space is tight; most frames have no built-in auxiliary contacts and require separate ordering;
Domestic substitute compatibility is less mature than Schneider CJX2 ecosystem;
Same rating usually at higher price; longer lead time occasionally for spare parts.
📌 Quick Selection Guide (150 Una cornice)
Choose Schneider LC1D: Fan / pompa / HVAC, municipal fire pump, replacement of existing LC1D, unstable grid voltage, easy future domestic substitution
Choose Siemens 3RT: Full Siemens automation system, servizio pesante / frequent AC-4 inching, minerario / metallurgia / crane, customer-specified German brand standard, multiple auxiliary feedback and diagnostic points
Quality baseline: Both comply with IEC60947-4-1 and CCC. Under normal fan/pump AC-3 non-frequent duty cycle, failure rate difference is minimal. Most on-site issues come from mismatched accessories rather than the contactor itself: Schneider LRD and Siemens 3RU thermal relays cannot be intermixed, different latching structure and trip curves.
📌 Suggestion for Your Current Project
Your reference: LC1D150F7 (AC110 V, 150 UN, 75 motore da kW)
If PLC inside cabinet is Siemens and full system standardization is required: select 3RT2055-1AF00 (AC110 V) with matching 3RU2 thermal relay
If only direct replacement and maintainability with budget control: prefer new Schneider TeSys Deca variant or domestic CJX2-150
Direct drop-in interchange between the two brands is NOT feasible: different mounting holes, thermal relay latch geometry and auxiliary contact layout.
- Application Scenarios for Schneider TeSys (LC1D/Deca) Contattori
Posizionamento centrale: Scopo generale, costruzione HVAC, municipal, standard panel, maintenance-friendly
- HVAC air conditioning, chiller units, air-cooled heat pumps
Tifosi, pompe dell'acqua, riscaldatori elettrici, torri di raffreddamento; industry standard in domestic HVAC. Good coil voltage tolerance for unstable supply voltage; built-in auxiliary contacts simplify latching, star-delta and reversing circuits.
- Municipal water supply & liquami, pompe antincendio, sprinkler pumps
Extensive deployment in pump control panels; huge installed base, easy spare parts sourcing and mature CJX2 domestic replacement, low long-term maintenance cost.
- Building distribution, commercial lighting, riscaldamento, heat pump resistive loads (AC-1)
4-pole contactors and CT building contactors suitable for lighting and heating circuits; widely specified by building designers.
- Macchinari generali, standard conveyor lines, macchine per l'imballaggio, woodworking machines
Normal AC-3 on/off duty (low inching frequency); high BOM and wiring efficiency for mass standard panel production.
- Retrofit and legacy equipment replacement
Direct replacement of failed original LC1D contactors; renovation projects without full automation platform migration and moderate budget.
- New energy auxiliary systems, cooling fans for energy storage systems
❌ Not preferred: Heavy impact loads, high-frequency AC-4 inching, full Siemens TIA automation solution, transito ferroviario, mining and metallurgy.
- Application Scenarios for Siemens SIRIUS 3RT Contactors
Posizionamento centrale: Industria pesante, alta affidabilità, funzionamento frequente, Siemens automation platform, ambienti difficili
- Metallurgia, minerario, aggregate, cemento, chemical heavy-duty machinery
High inrush current, dusty and vibrating environment; AC-4 inching and frequent reversing (roller tables, winches, frantoi) with conservative contact withstand margin.
- Macchine utensili, automotive assembly lines, robotic workcells
Full stack of PLC, VFD and safety relays from Siemens (Portale TIA). Standardized EPLAN drawings and device diagnostics for OEM and export machines.
- Transito ferroviario, ascensori, gru portuali, trasportatori per la movimentazione dei materiali
Strict consistency and certification requirements; side-mounted modular auxiliary contacts support multi-channel feedback and safety signal expansion.
- Power auxiliary systems, generator control panels
Widely specified by power industry designers for low-voltage auxiliary assemblies.
- High-end custom machinery, European export equipment
German-standard projects with customer mandatory Siemens brand requirement.
❌ Not preferred: Direct replacement of legacy Schneider contactors, budget ristretto, expectation of easy domestic substitute, limited cabinet space for auxiliary wiring.
- One-sentence Selection Rule (150 UN /75 kW frame)
Schneider: Fan/pump/HVAC, municipal fire pump, legacy LC1D replacement, easy domestic spare support, unstable grid voltage
Siemens: Full Siemens PLC solution, frequent AC-4 inching, mining/metallurgy/crane, customer-specified German system
- Additional Pitfall Reminders
- Thermal relays cannot cross brands: Schneider LRD and Siemens 3RU have incompatible clip mounting and different trip characteristic curves.
- Cross-brand substitution is not impossible, but accessories and mounting layout differ. New projects are recommended to maintain single-brand consistency.
- Both meet CCC and IEC60947-4-1. Failure rate difference is negligible for standard fan/pump AC-3 non-frequent operation.
Schneider TeSys Deca (LC1D) 3-Pole AC Contactor Model & Order Code List
Note: LC1D = 3-pole contactor, standard 1NO+1NC built-in auxiliary contacts; AC-3 @400 V; suffix coding rule:
F7: AC110 V 50/60 Hz (your LC1D150F7)
M7: AC220 V 50/60 Hz
D7: AC380 V 50/60 Hz
B7: AC24 V; E7: AC48 V; D7: AC42 V; N7: AC415 V; V7: AC400 V
B.D: DC24V; FD: DC110 V; MD: DC220 V
Newer domestic versions carry suffix C (LC1D09M7C); legacy versions without C are being phased out
LC1D150 and larger high-current frames: LC1D150F7 (legacy EOL), replacement LC1D150AEHE
- Standard Ratings (AC-3 @400 V, Energia + Common Order Codes)
| Modello | AC-3 400V Current | Potenza del motore | AC110 V Order No. | AC220 V Order No. | AC380 V Order No. | DC24 V Order No. |
| LC1D09 | 9 UN | 4 kW | LC1D09F7C | LC1D09M7C | LC1D09Q7C | LC1D09BDC |
| LC1D12 | 12 UN | 5.5 kW | LC1D12F7C | LC1D12M7C | LC1D12Q7C | LC1D12BDC |
| LC1D18 | 18 UN | 7.5 kW | LC1D18F7C | LC1D18M7C | LC1D18Q7C | LC1D18BDC |
| LC1D25 | 25 UN | 11 kW | LC1D25F7C | LC1D25M7C | LC1D25Q7C | LC1D25BDC |
| LC1D32 | 32 UN | 15 kW | LC1D32F7C | LC1D32M7C | LC1D32Q7C | LC1D32BDC |
| LC1D38 | 38 UN | 18.5 kW | LC1D38F7C | LC1D38M7C | LC1D38Q7C | LC1D38BDC |
| LC1D40 | 40 UN | 18.5 kW | LC1D40F7C | LC1D40M7C | LC1D40Q7C | LC1D40BDC |
| LC1D50 | 50 UN | 22 kW | LC1D50F7C | LC1D50M7C | LC1D50Q7C | LC1D50BDC |
| LC1D65 | 65 UN | 30 kW | LC1D65F7C | LC1D65M7C | LC1D65Q7C | LC1D65BDC |
| LC1D80 | 80 UN | 37 kW | LC1D80F7C | LC1D80M7C | LC1D80Q7C | LC1D80BDC |
| LC1D95 | 95 UN | 45 kW | LC1D95F7C | LC1D95M7C | LC1D95Q7C | LC1D95BDC |
| LC1D115 | 115 UN | 55 kW | LC1D115F7C | LC1D115M7C | LC1D115Q7C | LC1D115BDC |
| LC1D150 | 150 UN | 75 kW | LC1D150F7 (Legacy EOL) | LC1D150M7 | LC1D150Q7 | LC1D150BD |
| LC1D170 | 170 UN | 90 kW | LC1D170F7 | LC1D170M7 | LC1D170Q7 | LC1D170BD |
| LC1D205 | 205 UN | 110 kW | LC1D205F7 | LC1D205M7 | LC1D205Q7 | LC1D205BD |
| LC1D245 | 245 UN | 132 kW | LC1D245F7 | LC1D245M7 | LC1D245Q7 | LC1D245BD |
| LC1D300 | 300 UN | 160 kW | LC1D300F7 | LC1D300M7 | LC1D300Q7 | LC1D300BD |
| LC1D410 | 410 UN | 220 kW | LC1D410F7 | LC1D410M7 | LC1D410Q7 | LC1D410BD |
| LC1D475 | 475 UN | 250 kW | LC1D475F7 | LC1D475M7 | LC1D475Q7 | LC1D475BD |
| LC1D620 | 620 UN | 335 kW | LC1D620F7 | LC1D620M7 | LC1D620Q7 | LC1D620BD |
✅ Key note: LC1D150F7 (legacy end-of-life), upgrade replacement LC1D150AEHE (wide-voltage coil 48–130 V AC/DC)
- Coil Suffix Reference (AC suffix 7 = 50/60 Hz universale; 5=50 Hz; 6=60 Hz)
| Codice | Tensione CA | Codice | DC Voltage |
| B7 | 24 V e | B.D | 24 A DC |
| D7 | 42 V e | CD | 36 A DC |
| E7 | 48 V e | ED | 48 A DC |
| F7 | 110 V e | FD | 110 A DC |
| G7 | 120 V e | GD | 125 A DC |
| M7 | 220 V e | MD | 220 A DC |
| D7 | 380 V e | RD | 440 A DC |
| V7 | 400 V e | — | — |
| N7 | 415 V e | — | — |
- Common Compatible Accessory Order Codes (TeSys serie D)
| Accessorio | Codice ordine | Descrizione |
| Blocco contatti ausiliari | LADN11 | 1NO + 1NC |
| Blocco contatti ausiliari | LADN22 | 2NO + 2NC |
| On-delay timer | LADT2 | 0.1–30 s |
| Off-delay timer | LADR2 | 0.1–30 s |
| Interblocco meccanico | LAD9R1 | For reversing contactor |
| Soppressore di picchi della bobina | LADRC | AC coil transient absorption |
| Relè termico | Serie LRD | LRD485 for 150 UN |
| Reversing contactor assembly | LC2D | Pre-assembled forward/reverse |
| Star-delta starter assembly | LC3D | Star-delta contactor set |
- Additional Series
- LC1DT: 4-contattori polari (Carichi resistivi AC-1, riscaldamento, illuminazione)
- LC2D: Reversing contactors (integrated mechanical interlock)
- LC3D: Star-delta contactor assemblies
- TeSys Deca Advanced (wide coil): LC1DxxAEHE series, 48–130 V AC/DC, replaces legacy F7/G7 narrow-coil variants
⚠️ Important Remarks
- Small frames LC1D09~LC1D95 use current domestic order codes with suffix C (LC1D09F7C); 115 A and above high-current frames are commonly stocked without C, cross-compatible.
- LC1D150F7 EOL date: 31 Dec 2026. Use LC1D150AEHE for new projects.
- Specify terminal type at ordering: Terminale a vite / EverLink spring terminal / Busbar terminal. Busbar versions available for 150 A and larger frames.
- This is the commonly used BOM list, excluding special voltages (12 V, 277 V, 575 V and other export ratings).
Contattore,interruttore automatico,sensore,Codificatore,PLC,Convertitore

















NH42-63-318x560.png)