Schneider LC1D115F7 Contactor

Main contactor for 3-phase motor control, AC-3 115A, coil AC110V 50/60Hz, with built-in 1NO +1NC auxiliary contacts ✅ Model Breakdown LC1: Standard 3-pole contactor (non invertibile) D: TeSys D (TeSys Deca) serie 115: AC-3 rated operational current 115A (@440V) F: Coil voltage code = AC110V 7: 50/60Hz universal AC coil 📌 Core Electrical Parameters Item Parameter ...

  • Dettagli del prodotto

Main contactor for 3-phase motor control, AC-3 115A, coil AC110V 50/60Hz, with built-in 1NO +1NC auxiliary contacts

✅ Model Breakdown

LC1: Standard 3-pole contactor (non invertibile)

D: TeSys D (TeSys Deca) serie

115: AC-3 rated operational current 115A (@440V)

F: Coil voltage code = AC110V

7: 50/60Hz universal AC coil

📌 Core Electrical Parameters

ArticoloParametro
Contatti principali3P Normally Open (3NO)
AC-3 Operational Current Ie115UN (≤440 V)
AC-1 Resistive Load Ith200UN (40℃ free air)
Coil UcAC110V, 50/60Hz
Built-in Auxiliary Contacts1NO + 1NC (Standard)
Tensione di isolamento nominale Ui1000V
Tensione nominale di tenuta ad impulso Uimp8kV
Utilisation CategoryAC-1 / AC-3 / AC-3e / AC-4

Potenza nominale del motore (AC-3)

380/400V: 55kW

220/230V: 30kW

415/440V: 59kW

660/690V: 80kW

📐 Mechanical & Installazione

Montaggio: Guida DIN + base plate screw mounting

Terminali: Screw terminals for copper bars / cavi

Temperatura ambiente operativa: -40℃ ~ +60 ℃

Certificazioni: CCC, UL, CSA, CEI, RoHS

🧩 Extension Accessories (Common for TeSys D)

  1. Blocco contatti ausiliari: LA1DN (add extra NO/NC contacts)
  2. Timing unit: LA2DT on-delay / LA2DR off-delay
  3. Surge suppressor module: LA4DA (RC snubber for coil, suppress induced overvoltage)
  4. Relè termico: LRD485 (motor protection matched for 115A)
  5. Interblocco meccanico: LA9D1150 (for forward/reversing circuit)

⚠️ Selection & Informazioni sulla sostituzione

  1. Other coil variants of the same series:

LC1D115M7: AC220V; LC1D115Q7: AC380V

  1. End-of-life notice: Old model LC1D1156F7 discontinued, LC1D115F7 is current TeSys Deca version; New generation upgrade replacement model: LC1D115A6KUE (wide voltage coil 100–250V AC/DC)
  2. Distinzione: LC1D (TeSys Deca) ≠ LC1F (TeSys F large frame contactor, different outline dimension)

🛠 Typical Application Scenarios

Start/stop control for 3-phase motors: compressori d'aria, pompe dell'acqua, tifosi, trasportatori a nastro

Chilled water units & HVAC control cabinets

Low-voltage complete sets, PLC driven high-power motor circuits

Resistance furnaces and high-power resistive loads (200A rating under AC-1)

❗ Common Troubleshooting

  1. Bobina eccitata, no pull-in: Measure coil voltage for 110V; check coil open circuit and loose wiring
  2. Loud buzzing noise after pull-in: Bassa tensione di alimentazione, accumulated dust on iron core, broken short-circuit ring
  3. Frequent contact erosion: AC-4 heavy duty jogging application, upgrade current rating; check motor stall condition
  4. Segnale contatto ausiliario anomalo: Aged auxiliary contacts or loose wiring, add LA1DN auxiliary block

Supporting Documents for LC1D115F7

  1. Dimensioni del contorno (mm)

Larghezza: 120

Altezza: 158

Profondità: 136

Montaggio: 35Guida DIN da mm / M6 screw base mounting

Fori di montaggio: Vertical pitch 130mm; horizontal pitch 96~110mm (slotted hole)

Cablaggio del circuito principale: Max 120mm² solid cable; 50mm² flexible cable

Auxiliary control circuit: Max 2.5mm²

  1. Basic Wiring Schematic

Circuito principale

L1/L2/L3 → Contactor top terminals 1/L1, 3/L2, 5/L3; bottom terminals 2/T1, 4/T2, 6/T3 → Motor

Circuito di controllo (AC110V Coil)

A1, A2: Terminali della bobina, powered by AC110V

Standard auxiliary contacts: NO(Normalmente aperto) 13-14; NC(Normalmente chiuso) 21-22

Typical start-stop circuit: Start button parallel with 13-14 self-latching contact, series with stop button, connected to coil A1/A2.

For forward/reversing: Use LC1D115 + LA9D1150 mechanical interlock, electrical interlock is mandatory to prevent phase-to-phase short circuit.

  1. LRD Thermal Overload Relay Matching List (Direct plug-in for LC1D115)

LRD43xx series, direct bottom plug-in without adapter; Class10A, sovraccarico del motore + protezione dalla perdita di fase

ArticoloParametro
Contatti principali3P Normally Open (3NO)
AC-3 Operational Current Ie115UN (≤440 V)
AC-1 Resistive Load Ith200UN (40℃ free air)
Coil UcAC110V, 50/60Hz
Built-in Auxiliary Contacts1NO + 1NC (Standard)
Tensione di isolamento nominale Ui1000V
Tensione nominale di tenuta ad impulso Uimp8kV
Utilisation CategoryAC-1 / AC-3 / AC-3e / AC-4

Alternative standalone mounting: LRD33 series, requires adapter LA7D3058 for separate base installation.

  1. Elenco dei modelli sostitutivi

✅ Original Schneider Sostituzione dell'aggiornamento (LC1D115F7 planned phase-out)

  1. LC1D115AEHE: 3P 115A, coil 48~130V AC/DC (perfect replacement for original AC110V coil, raccomandato)
  2. LC1D115AKUE: 3P 115A, wide voltage coil 100~250V AC/DC, best versatility

✅ Domestic equivalent replacement (compatible outline & terminal position for direct swap)

  1. Shanghai People: CJX2-D115 (coil AC110V), silver contacts, fully matching dimension
  2. CINT: NC2-115
  3. Delizioso: CJX2-115

Nota: Domestic models differ slightly in auxiliary contact configuration and accessory base, verify mounting hole and auxiliary contacts before bulk replacement.

  1. Selezione & Note di sostituzione
  2. Tensione della bobina: LC1D115F7 = AC110V; verify coil rating during replacement, do not directly use AC220V version.
  3. Compatibilità accessori: LA4DA coil surge suppressor, LA1DN auxiliary contact, LA9D1150 mechanical interlock are fully compatible.
  4. Load classification: AC-4 frequent jogging operation, avoid full-load operation, upgrade current rating.

Application Scenarios of LC1D115F7 (Bobina AC110V, AC-3 115A, 55kW motor @400V)

Core positioning: Mainly for start/stop control of 3-phase AC motors, also switching high-power resistive loads; AC110V control circuit widely used in panel build, imported equipment retrofitting, HVAC & air compressor control cabinets

🏭 Industrial Equipment

  1. Compressori d'aria: Start/stop of main motor for 55kW screw air compressors, protected by LRD thermal relay against overload and phase loss; PLC digital output drives contactor coil.
  2. Pompa dell'acqua & Water Supply System: Pompe di circolazione, booster pumps, sewage pumps as main circuit of constant pressure water supply cabinet; can be configured for 1-duty-1-standby pump interlock.
  3. Fan System: Dust removal fans, induced draft fans, large air handling unit supply fans; HVAC plant room and waste gas treatment cabinet.
  4. Macchinari di trasporto: Trasportatori a nastro, elevatori a tazze, linee a rulli; heavy starting duty under standard AC-3 load.
  5. Machine & Gomma & Plastic Equipment: Estrusori, large lathe main motors, injection molding machine hydraulic pump motors; retrofitting of old imported cabinets (many units adopt AC110V control circuit).
  6. Agitatori: Chemical and water treatment mixing motors, add cabinet protection for corrosive environment.

🏢 Building HVAC & Infrastrutture

  1. Central Chiller Plant: Pompe dell'acqua di raffreddamento, pompe per acqua refrigerata, ventilatori delle torri di raffreddamento, linked with building BA system; AC110V control circuit commonly adopted in foreign HVAC cabinets.
  2. Acqua & Sewage Pumping Station: Underground pump house, municipal sewage lifting pump control cabinet.
  3. Heat Exchange Station: Circulation pumps for heating systems.

🔥 Resistive Load Switching (AC-1, 200UN)

For non-motor pure resistive load, maximum current rating increases to 200A

High-power electric heating tubes, forni a resistenza, drying oven heating circuits

Large 3-phase lighting loads

⚙️ Electrical Panel Industry

  1. PLC Control Cabinet: PLC digital output drives coil, motor status feedback signal from built-in 1NO+1NC auxiliary contacts of contactor.
  2. Soft Starter Bypass Contactor: Engage bypass after soft start completion for continuous operation.
  3. Forward/Reversing Reversing Circuit: Equipped with LA9D1150 mechanical interlock + electrical interlock for cranes and lifting equipment.

⚠️ AC-4 frequent jogging (frequent forward/reverse, frequent start-stop) accelerates contact wear, current rating shall be increased.

⚡ New Energy & Stoccaggio dell'energia

Cooling water pumps and fan control cabinets for PV & sistemi di accumulo dell’energia

Fire exhaust fans for energy storage systems

📌 Selection & Note operative

  1. Tensione della bobina: AC110V, widely used for imported equipment, foreign HVAC cabinets and legacy retrofit; AC220V version cannot be directly used for replacement.
  2. Load category: AC-3 preferred for normal motor start-stop; use caution for AC-4 frequent jogging.
  3. Protection matching: Must be fitted with LRD43 series thermal overload relay or upstream circuit breaker for short-circuit protection.
  4. End-of-life notice: LC1D115F7 scheduled for phase-out by end of 2026; new projects prefer wide voltage upgrade model LC1D115AKUE.

Schneider TeSys Deca (Original TeSys D) LC1D 3-Pole Contactor Full Model List

LC1D: 3-pole normally open main contacts, contatti ausiliari standard 1NO+1NC; suffix code: F7=AC110V 50/60Hz; M7=AC220V; Q7=AC380V; B7=AC24V; E7=AC48V; 7=AC 50/60Hz

Esempio: LC1D09F7 = 9A, Bobina AC110V; LC1D115F7 is your target model

  1. LC1D Base Models (AC-3 @440V)
Modello baseCorrente nominale AC-3(UN)Potenza motore abbinata a 400 V(kW)
LC1D0994
LC1D12125.5
LC1D18187.5
LC1D252511
LC1D323215
LC1D383818.5
LC1D404018.5
LC1D505022
LC1D656530
LC1D808037
LC1D959545
LC1D11511555
LC1D15015075
LC1D17017090
LC1D205205110
LC1D245245132
LC1D300300160
LC1D410410220
LC1D475475250
LC1D620620315

Full Model = Base Model + Coil Suffix, per esempio. LC1D09F7, LC1D115M7, LC1D150Q7

  1. Common AC Coil Suffix Reference Table (50/60Hz)
CodiceTensione della bobina
B7AC24V
E7AC48V
F7AC110V (Il tuo modello)
M7AC220V
P7AC230V
D7AC380V
V7AC400V
R7AC440V

Bobina CC: BD=24 V CC, FD=DC110V, MD=DC220V; New wide voltage: KUE=100~250V AC/DC, EHE=48~130V AC/DC

  1. Derivative Series (Same TeSys D Platform)
  2. LC2D: Teleinvertitore (integrated forward/reversing with built-in mechanical & electrical interlock)

LC2D09F7, LC2D12F7 … LC2D115F7

  1. LC1DT: 4-contattore di polo (DT20/DT25/DT32/DT40 etc., per monofase / dual-circuit resistive load)
  2. LC1DxxxS22: Safety mirror contact version, for safety circuit and emergency stop control
  3. LC1DxxA6KUE: New generation wide voltage coil upgrade model (replaces legacy F7/M7/Q7)
  4. Common Full Models of LC1D115

LC1D115F7: AC110V (your referenced model)

LC1D115M7: AC220V

LC1D115Q7: AC380V

LC1D115B7: AC24V

LC1D115E7: AC48V

LC1D115A6KUE: Wide voltage 100~250V AC/DC upgrade replacement

  1. Matched LRD Thermal Relay Series (Direct Plug-in for LC1D)

LRD01~LRD38 (matches 09~38A); LRD43 series (matches 40~170A, LRD4365, LRD4367, LRD4369 for LC1D115)

  1. Selection Remarks
  2. Suffix with C (per esempio. LC1D115F7C) = China local version, non-C = import version, identical electrical performance
  3. Coil can be replaced separately for large frame LC1D115 and above; coils of small size 09~95A are non-replaceable
  4. Old model LC1Dxxx6F7 being phased out; new projects prefer A6KUE wide voltage version