NXC-65 from the Kunlun Series by CHINT Electric is a 3-pole AC contactor, valutato a 65 A nella serie NXC. Il modello completo è tipicamente espresso come NXC-65 [Tensione della bobina] [Frequenza] (per esempio., NXC-65 220 V 50 Hz). It is mainly used for frequent starting and control of AC motors, as well as remote making and breaking of circuits.
Parametri elettrici principali
| Articolo | Specifica | Descrizione |
| Corrente operativa nominale (Cioè) | 65UN | Rated current of the main circuit |
| Corrente termica convenzionale (Ith) | 80UN | Maximum continuous operating current |
| Tensione operativa nominale (Ue) | 220V~690V | Voltage range of the main circuit |
| Numero di poli | 3P | Three-phase main contact design |
| Configurazione del contatto principale | 3NO (3 Normalmente aperto) | Standard for connecting three-phase power |
| Contatti ausiliari | 1NO + 1NC | Integrato 1 NO and 1 NC, espandibile |
| Tensione della bobina | AC24V/127V/220V/380V, ecc. | Multiple voltages available for various control systems |
| Vita meccanica | 1,200,000 operazioni | Mechanical operating cycles |
| Vita elettrica | 100,000 operazioni | Electrical cycles under rated load |
| Standard applicabili | GB/T 14048.1/IEC 60947-1, GB/T 14048.4/IEC 60947-4-1 | National and international standards |
Caratteristiche del prodotto
- Struttura compatta: Kunlun series design, piccola dimensione, low installation space requirement
- Alta affidabilità: Made of high-quality materials with precision manufacturing, adatto per ambienti industriali difficili
- Basso consumo energetico: Low coil power loss, obvious energy-saving effect
- Installazione semplice & manutenzione: Montaggio su guida DIN standard da 35 mm, clear terminals for easy operation
- Strong expandability: Optional auxiliary contacts, air delay modules and other accessories available
- Good safety performance: Excellent arc extinguishing performance and high breaking capacity
Applicazioni
AC motor control: Frequent start, stop and reversing control for three-phase asynchronous motors up to approx. 30kW
Sistemi di automazione industriale: Control of production lines, trasportatori, tifosi, pompe, ecc.
Electrical control systems: Combined with thermal overload relays to form magnetic starters for motor overload protection
Edificio elettrico: Air conditioning systems, attrezzature antincendio, water pump control systems
New energy equipment: Auxiliary control circuits for charging piles, inverter fotovoltaici, ecc.
Partial List of CHINT NXC Series Models
| Modello | Corrente nominale | Corrente termica convenzionale | Typical Motor Power | Note |
| NXC-06 | 6UN | 10UN | Up to 2.2kW | Minimum rating |
| NXC-12 | 12UN | 16UN | Up to 5.5kW | |
| NXC-18 | 18UN | 25UN | Up to 7.5kW | |
| NXC-25 | 25UN | 32UN | Up to 11kW | |
| NXC-32 | 32UN | 40UN | Up to 15kW | |
| NXC-40 | 40UN | 50UN | Up to 18.5kW | |
| NXC-50 | 50UN | 63UN | Up to 22kW | |
| NXC-65 | 65UN | 80UN | Up to 30kW | |
| NXC-80 | 80UN | 100UN | Up to 37kW | |
| NXC-95 | 95UN | 125UN | Up to 45kW | |
| NXC-115 | 115UN | 140UN | Up to 55kW | |
| NXC-150 | 150UN | 175UN | Up to 75kW |
Confronto tra marchi (Equivalent AC Contactors)
Below is a comparison between CHINT NXC-65 and equivalent contactors from major brands, all functionally compatible:
| CINT | Schneider | Siemens | ABB | Delizioso | Compatibilità |
| NXC-65 | LC1D65M7C | 3RT2036-1AP00 | A63-30-10 | CJX2-6511 | Functionally compatible, slight dimensional differences, mounting may need adjustment |
Brand Feature Comparison
| Marca | Punti di forza fondamentali | Applicazioni tipiche |
| CINT | Conveniente, extensive after-sales network | Controllo industriale generale, civile & edificio elettrico |
| Schneider | Marchio internazionale, tecnologia matura, alta affidabilità | High-end industrial automation, critical equipment |
| Siemens | High intelligence, strong communication functions | Industria 4.0, intelligent manufacturing |
| ABB | Alte prestazioni, robust in harsh environments | Industria pesante, nuova energia, transito ferroviario |
| Delizioso | Affordable, high domestic market share | SMEs, civil electrical systems |
Note importanti
- Ensure the coil voltage matches the control system to avoid malfunction.
- Use the contactor with protective devices such as thermal overload relays for motor overload protection.
- Per funzionamento ad alta frequenza, select models with longer electrical life or increase maintenance frequency.
- Ensure firm wiring of main and control circuits to prevent failures caused by poor contact.
CHINT Contactor Full Series Coding System & Riferimento incrociato del marchio
- CHINT Contactor Series Overview & Regole di denominazione
1.1 Main Series Classification
| Serie | Posizionamento | Intervallo corrente | Applicazioni tipiche |
| Serie NXC | Kunlun, new flagship | 6A~630A | Controllo industriale generale, motor starting, distribuzione del potere |
| Serie NC1 | Economic basic series | 9A~95A | Piccola attrezzatura, controllo dell'illuminazione |
| Serie NC2 | Standard industrial series | 9A~630A | Industriale generale & controllo motorio |
| Serie NC8 | High-performance series | 6A~100A | Operazione frequente, controllo di precisione |
| Serie CJX2 | Classic predecessor of NXC | 9A~95A | Traditional industrial equipment, piccoli motori |
| Serie CJ20 | High-current series | 10A~630A | High-power motors, attrezzature pesanti |
| CJ19 Series | Capacitor switching dedicated | 16A~100A | Compensazione della potenza reattiva, capacitor cabinets |
| NCH8 Series | Domestico / civil use | 16A~63A | Smart home, small appliances |
| NXJ Series | Mini electromagnetic relay | 5A~10A | Circuiti di controllo, signal switching |
| CKJ Series | Vacuum contactor | 63A~630A | High-voltage applications, avviamenti frequenti |
1.2 CHINT Contactor Model Naming Rules
NXC Series Format
NXC □□□ [M] [Tensione della bobina] [Frequenza]
│ │ │ │ │
│ │ │ │ └─ Coil frequency (50Hz/60 Hz, default 50Hz)
│ │ │ └─ Coil voltage (AC24V/110V/220V/380V or DC24V/110V/220V)
│ │ └─ M = reversing contactor; blank = non-reversing
│ └─ Rated operational current (UN)
└─ Brand code + product type (CINT + Contattore CA)
Auxiliary Contact Marking
Modello basso: default 1NO + 1NC (11)
Extended format: NXC-□□□-[XX], where XX = contact combination (01=0NO1NC, 22=2NO2NC)
Special Function Codes
Z: DC-operated contactor
N: Reversing contactor (NS = horizontal, NC = vertical)
-12: Newer version with improved performance
- Complete CHINT Contactor Model List
2.1 Full NXC Series (Kunlun)
| Modello | Corrente nominale | Corrente termica | Typical Motor Power (AC-3, 380V) | Base Aux. Contatti |
| NXC-06 | 6UN | 10UN | Up to 2.2kW | 1NA+1NC |
| NXC-09 | 9UN | 12.5UN | Up to 3kW | 1NA+1NC |
| NXC-12 | 12UN | 16UN | Up to 5.5kW | 1NA+1NC |
| NXC-18 | 18UN | 25UN | Up to 7.5kW | 1NA+1NC |
| NXC-25 | 25UN | 32UN | Up to 11kW | 1NA+1NC |
| NXC-32 | 32UN | 40UN | Up to 15kW | 1NA+1NC |
| NXC-40 | 40UN | 50UN | Up to 18.5kW | 1NA+1NC |
| NXC-50 | 50UN | 63UN | Up to 22kW | 1NA+1NC |
| NXC-65 | 65UN | 80UN | Up to 30kW | 1NA+1NC |
| NXC-80 | 80UN | 100UN | Up to 37kW | 1NA+1NC |
| NXC-95 | 95UN | 125UN | Up to 45kW | 1NA+1NC |
| NXC-115 | 115UN | 140UN | Up to 55kW | 1NA+1NC |
| NXC-150 | 150UN | 175UN | Up to 75kW | 1NA+1NC |
| NXC-185 | 185UN | 210UN | Up to 90kW | 1NA+1NC |
| NXC-225 | 225UN | 250UN | Up to 110kW | 1NA+1NC |
| NXC-265 | 265UN | 300UN | Up to 132kW | 1NA+1NC |
| NXC-300 | 300UN | 350UN | Up to 160kW | 1NA+1NC |
| NXC-370 | 370UN | 400UN | Up to 200kW | 1NA+1NC |
| NXC-400 | 400UN | 450UN | Up to 220kW | 1NA+1NC |
| NXC-500 | 500UN | 560UN | Up to 250kW | 1NA+1NC |
| NXC-630 | 630UN | 700UN | Up to 315kW | 1NA+1NC |
2.2 Core Models of Other Series
| Serie | Modelli fondamentali | Intervallo corrente | Caratteristiche principali |
| NC1 | NC1-09/12/18/25/32/40 /50/65/80/95 | 9A~95A | Compatto, economico |
| NC2 | NC2-09~150 | 9A~150A | Standard design, versatile |
| NC8 | NC8-06~100 | 6A~100A | Bassa potenza, long mechanical life |
| CJX2 | CJX2-09~95 | 9A~95A | Mounting compatible with Schneider LC1-D |
| CJ20 | CJ20-10~630 | 10A~630A | High current carrying capacity |
| CJ19 | CJ19-16~100 | 16A~100A | Special arc quenching for capacitor switching |
- Cross-Brand Reference for CHINT Contactors
3.1 General Contactor Cross Reference (AC-3, 380V)
| CINT | Schneider | Siemens | ABB | Delizioso | Functional Compatibility |
| NXC-06 | LC1D0610M5C | 3RT2015-1AP00 | A6-30-10 | CJX2-0610 | Pienamente compatibile, minor dimensional differences |
| NXC-09 | LC1D0910M5C | 3RT2016-1AP00 | A9-30-10 | CJX2-0910 | Pienamente compatibile, minor dimensional differences |
| NXC-12 | LC1D1210M5C | 3RT2017-1AP00 | A12-30-10 | CJX2-1210 | Pienamente compatibile, minor dimensional differences |
| NXC-18 | LC1D1810M5C | 3RT2026-1AP00 | A18-30-10 | CJX2-1810 | Pienamente compatibile, minor dimensional differences |
| NXC-25 | LC1D2510M5C | 3RT2027-1AP00 | A26-30-10 | CJX2-2510 | Pienamente compatibile, minor dimensional differences |
| NXC-32 | LC1D3210M5C | 3RT2036-1AP00 | A30-30-10 | CJX2-3210 | Pienamente compatibile, minor dimensional differences |
| NXC-40 | LC1D4010M5C | 3RT2037-1AP00 | A40-30-10 | CJX2-4010 | Pienamente compatibile, minor dimensional differences |
| NXC-50 | LC1D5010M5C | 3RT2040-1AP00 | A50-30-10 | CJX2-5010 | Pienamente compatibile, minor dimensional differences |
| NXC-65 | LC1D6510M5C | 3RT2046-1AP00 | A63-30-10 | CJX2-6510 | Pienamente compatibile, minor dimensional differences |
| NXC-80 | LC1D8010M5C | 3RT2056-1AP00 | A75-30-10 | CJX2-8010 | Pienamente compatibile, minor dimensional differences |
| NXC-95 | LC1D9510M5C | 3RT2066-1AP00 | A95-30-10 | CJX2-9510 | Pienamente compatibile, minor dimensional differences |
| NXC-115 | LC1D11510M5C | 3RT2076-1AP00 | A110-30-10 | CJX2-11510 | Generally compatible, mounting may need adjustment |
| NXC-150 | LC1D15010M5C | 3RT2086-1AP00 | A145-30-10 | CJX2-15010 | Generally compatible, mounting may need adjustment |
3.2 Brand Technical Comparison
| Marca | Caratteristiche Tecniche | Strengths | Price Position |
| CINT | Modular Kunlun design, low-power coil, long-life contacts | Industria generale, building electrics | Mid-low, conveniente |
| Schneider | TeSys series, intelligent control, rich communication | Automazione di fascia alta, critical loads | Mid-high, leading tech |
| Siemens | 3RT series, alta affidabilità, protezione integrata | Industria 4.0, smart manufacturing | Alto, stabile |
| ABB | Modulare, elevata immunità al rumore, eco-friendly materials | Industria pesante, nuova energia, transit | Alto, premium performance |
| Delizioso | CJX2 compatible with CHINT | SMEs, civil installations | Basso, conveniente |
- Selezione & Linee guida per la sostituzione
4.1 Parametri di selezione chiave
- Corrente nominale (Cioè): Select according to load; for motors, Ie ≥ 1.2 × motor rated current.
- Tensione della bobina: Must match control system (AC/DC not interchangeable).
- Frequenza operativa: Per >1200 operazioni/ora, use long-life models.
- Contatti ausiliari: Choose based on control logic (default 1NO+1NC).
- Montaggio: Guida DIN standard da 35 mm; high-current models may use bolt mounting.
4.2 Cross-Brand Replacement Notes
- Mechanical compatibility
NXC mostly compatible with Schneider LC1-D mounting, but hole positions differ slightly.
Models above 100A vary greatly; brackets may need modification.
- Electrical compatibility
Coil voltage and frequency must match exactly.
Auxiliary contact ratings differ (CHINT ~5A, some Schneider ~10A).
Short-circuit coordination with fuses/circuit breakers should be rechecked.
- Performance differences
NXC: vita meccanica 1.2 milioni, vita elettrica 100,000 (AC-3).
Premium Schneider/Siemens models reach 200,000 electrical cycles for ultra-frequent use.
4.3 NXC vs CJX2 Replacement
| CHINT CJX2 | Equivalent NXC | Upgrade Benefits |
| CJX2-09 | NXC-09 | Smaller, potenza inferiore, vita più lunga |
| CJX2-12 | NXC-12 | Smaller, potenza inferiore, vita più lunga |
| CJX2-18 | NXC-18 | Smaller, potenza inferiore, vita più lunga |
| CJX2-25 | NXC-25 | Smaller, potenza inferiore, vita più lunga |
| CJX2-32 | NXC-32 | Smaller, potenza inferiore, vita più lunga |
| CJX2-40 | NXC-40 | Smaller, potenza inferiore, vita più lunga |
| CJX2-50 | NXC-50 | Smaller, potenza inferiore, vita più lunga |
| CJX2-65 | NXC-65 | Smaller, potenza inferiore, vita più lunga |
| CJX2-80 | NXC-80 | Smaller, potenza inferiore, vita più lunga |
| CJX2-95 | NXC-95 | Smaller, potenza inferiore, vita più lunga |
- Quick Motor Selection Table
| Potenza del motore (kW) | Corrente nominale (UN) | Recommended CHINT | Schneider | Siemens | ABB |
| 2.2 | 5 | NXC-06 | LC1D0610 | 3RT2015 | A6-30-10 |
| 3 | 6.5 | NXC-09 | LC1D0910 | 3RT2016 | A9-30-10 |
| 5.5 | 12 | NXC-12 | LC1D1210 | 3RT2017 | A12-30-10 |
| 7.5 | 16 | NXC-18 | LC1D1810 | 3RT2026 | A18-30-10 |
| 11 | 23 | NXC-25 | LC1D2510 | 3RT2027 | A26-30-10 |
| 15 | 32 | NXC-32 | LC1D3210 | 3RT2036 | A30-30-10 |
| 18.5 | 39 | NXC-40 | LC1D4010 | 3RT2037 | A40-30-10 |
| 22 | 47 | NXC-50 | LC1D5010 | 3RT2040 | A50-30-10 |
| 30 | 63 | NXC-65 | LC1D6510 | 3RT2046 | A63-30-10 |
| 37 | 78 | NXC-80 | LC1D8010 | 3RT2056 | A75-30-10 |
| 45 | 94 | NXC-95 | LC1D9510 | 3RT2066 | A95-30-10 |
CHINT contactors cover a full range from 6A to 630A. The NXC (Kunlun) series offers greatly improved performance, reliability and compatibility, and can directly replace the CJX2 series and equivalent products from other brands. Per la sostituzione tra marchi diversi, verify rated current, tensione della bobina, mounting dimensions and auxiliary contact configuration to ensure stable system operation.
Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari


















NH42-63-318x560.png)