Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Di Contatto |

Schneider MCCB CVS160F-3P-125A - Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari

interruttore automatico/

Schneider MCCB CVS160F-3P-125A

Schneider CVS Series MCCB (Molded Case Circuit Breaker) Model Explanation: MCCB‑CVS160F‑3P‑125A MCCB: Molded Case Circuit Breaker CVS: Schneider CVS Series MCCB 160: Frame rating current 160A F: Breaking capacity class, Type F: 36kA@400VAC 3P: 3 poli (three‑phase three‑wire) 125UN: Rated operational current 125A Basic Parameters Type: Molded Case Circuit Breaker Series: CVS Frame current: 160UN ...

  • Dettagli del prodotto

Schneider CVS Series MCCB (Molded Case Circuit Breaker)

Model Explanation: MCCB‑CVS160F‑3P‑125A

MCCB: Molded Case Circuit Breaker

CVS: Schneider CVS Series MCCB

160: Frame rating current 160A

F: Breaking capacity class, Type F: 36kA@400VAC

3P: 3 poli (three‑phase three‑wire)

125UN: Rated operational current 125A

Parametri di base

Tipo: Molded Case Circuit Breaker

Series: CVS

Frame current: 160UN

Corrente nominale: 125UN

Poles: 3P

Potere di interruzione: 36IL

Application: Three‑phase power distribution protection

Below are the key engineering data for Schneider MCCB‑CVS160F‑3P‑125A (Order No. LV516332) for direct selection, panel layout and replacement.

  1. Dimensioni (Fixed Mounted Type)
DimensionValoreNote
Width (W)90mmStandard 3P width
Height (H)185mmIncluding handle
Depth (D)105mmExcl. terminals; approx. 120mm incl. terminals
Mounting hole spacing75mm*150mm4*M6 mounting holes
Degree of protectionIP40Complies with IEC 60529
  1. Connection Method
  2. Standard: Front connection, predefinito, no extra accessories required
  3. Optional:

Rear connection: requires dedicated rear connection base

Plug‑in connection: requires plug‑in base for quick replacement

  1. Connection Specifications:

Copper bar: max. 120mm² (raccomandato)

Cable: max. 150mm² (copper), cable lugs recommended

Rated torque: M10 bolt, 25N·m

  1. Recommended Replacement Models

3.1 Schneider Direct Replacements

SeriesModelloFeaturesCompatibility
CVS OriginalCVS160F TM125D 3P3D (LV516332)Identical, direct replacementFully compatible
NSX (Premio)NSX160F TM125D 3P3D (LV430632)Higher breaking capacity (70kA@400V), optional electronic tripStesse dimensioni, enhanced functions
EZD (Economic)EZD160E TMD125 3PLower cost, 25kA@400VStesse dimensioni, lower breaking capacity

3.2 Other Brands

MarcaModelloMatching Parameters
ABBTmax T2N160 TMD125 3PFrame 160A, In 125A, 36IL
Siemens3VL1716‑1DD33‑0AA0Frame 160A, In 125A, 36IL
CintoNXM‑160S/3300 125AFrame 160A, In 125A, 36IL
  1. Additional Notes
  2. Trip unit: TM‑D thermal‑magnetic, adjustable overload (87.5–125A), fixed short‑circuit (≈10In)
  3. Potere di interruzione: 36kA@400VAC, complies with IEC 60947‑2
  4. Mounting: Fixed (standard), plug‑in (optional), withdrawable (optional)

Complete List of Equivalent Replacements for Schneider MCCB‑CVS160F‑3P‑125A

All below match key parameters: frame 160A, In 125A, 3P, 36kA@400V, thermal‑magnetic trip, suitable for direct engineering replacement.

  1. Schneider Direct Replacements (Seamless Compatibility)
SeriesModelloOrder No.FeaturesCompatibility
CVS OriginalCVS160F TM125D 3P3DLV516332Identical, direct replacement100% compatible
NSX PremiumNSX160F TM125D 3P3DLV43063270kA@400V, optional electronic tripStesse dimensioni
EZD EconomicEZD160E TMD125 3PLV510332Cost‑effective, 25kA@400VStesse dimensioni
  1. International Brand Equivalents

ABB

SeriesModelloKey ParametersFeatures
3VL3VL1716‑1DD33‑0AA0160A frame, 125UN, 36ILModular design
3VT3VT8116‑1AA03‑0AA0Thermal‑magnetic, 36IL, 3PEconomic, reliable

Siemens

SeriesModelloKey ParametersFeatures
3VL3VL1716‑1DD33‑0AA0160A frame, 125UN, 36ILModular design
3VT3VT8116‑1AA03‑0AA0Thermal‑magnetic, 36IL, 3PEconomic, reliable

Eaton Moeller

SeriesModelloKey ParametersFeatures
NZMNZM2‑160 TM125 3P160A frame, 125UN, 36ILHigh reliability for industry
  1. Chinese Domestic Brands (Cost‑Effective)

Cinto

SeriesModelloKey ParametersFeatures
NXMNXM‑160S/3300 125A160UN, 125UN, 36ILHigh cost‑performance
CDM6iCDM6i‑160M/3300B 125AThermal‑magnetic, 36IL, fixedSmart options available

Delizioso

SeriesModelloKey ParametersFeatures
CDM3CDM3‑160S/3300 125A160UN, 125UN, 36ILStable performance
CDM1CDM1‑160L/3300 125AThermal‑magnetic, 36IL, 3PProven classic

TENGEN

SeriesModelloKey ParametersFeatures
TGM1TGM1‑160L/3300 125A160UN, 125UN, 36ILReliable domestic choice
  1. Key Selection Criteria

4.1 Core Parameter Matching Table

ItemOriginal RequirementReplacement Must Meet
Frame current160UN160UN
Corrente nominale125UN125UN
Poles3P3P
Potere di interruzione36kA@400V≥ 36kA@400V
Trip typeThermal‑magnetic (TM‑D)Thermal‑magnetic (TMD/TMF)
MountingFixedFixed (or with adapter)
ConnectionFrontFront (or with adapter)

4.2 Replacement Notes

  1. Dimensioni: Most replacements: W90mm × H185mm × D105mm, direct fit
  2. Trip characteristics: Overload 87.5–125A, short‑circuit ≈10In must match
  3. Accessories: Check compatibility for auxiliary contacts, undervoltage release, ecc.
  4. Certificazione: CEI / GB certified
  5. Recommended Solutions
ApplicationRecommended ModelReason
Original replacementSchneider CVS160F TM125D 3P3DIdentical, zero risk
Performance upgradeABB T2N160 TMD125 3P or Siemens 3VL1716‑1DD33‑0AA0International brand, reliable
Cost controlChint NXM‑160S/3300 125A or Delixi CDM3‑160S/3300 125ACost‑effective, good local support

Prec:

Lascia una risposta

Lasciate un messaggio