Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Di Contatto |

Interruttore automatico Schneider NSX250A - Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari

interruttore automatico/

Interruttore automatico Schneider NSX250A

Parameter ItemParameter ValueDescription
Frame Current250UNMaximum current-carrying capacity
Corrente nominale40/100/160/250UNOptional specifications, must match the load
Capacità di interruzione36IL (Type F)Maximum breaking current in case of short circuit
50IL (Type N)
70-100IL (Type H/S)
Tensione nominale690V eMaximum operating voltage
1000V e (special models)
Numero di poli3P/4PThree-phase / three-phase four-wire system
Trip Unit TypeTMD (Thermomagnetic)Selection of protection mechanism
Micrologic 2.2/4.2/6.2/7.2 (Elettronico)
Metodo di installazioneFixed typeFlexible installation options
Plug-in type
Draw-out type

  • Dettagli del prodotto

Product Overview

The Schneider NSX250A is a 250A frame current rating product under the ComPacT NSX series of molded case circuit breakers. Specifically designed for medium and low-voltage power distribution systems, it features high reliability, modular design, and digital characteristics, and is a key component of Schneider’s EcoStruxure power distribution solutions.

Core Parameters

Parameter ItemParameter ValueDescription
Frame Current250UNMaximum current-carrying capacity
Corrente nominale40/100/160/250UNOptional specifications, must match the load
Capacità di interruzione36IL (Type F)Maximum breaking current in case of short circuit
50IL (Type N)
70-100IL (Type H/S)
Tensione nominale690V eMaximum operating voltage
1000V e (special models)
Numero di poli3P/4PThree-phase / three-phase four-wire system
Trip Unit TypeTMD (Thermomagnetic)Selection of protection mechanism
Micrologic 2.2/4.2/6.2/7.2 (Elettronico)
Metodo di installazioneFixed typeFlexible installation options
Plug-in type
Draw-out type

Trip Unit Comparison

1️⃣ TMD (Thermomagnetic Trip Unit)

Working Principle: Thermal elements (bimetallic strips) detect overloads, and electromagnetic elements detect short circuits.

Features: Simple structure, basso costo, narrow setting range (0.7~1In).

Application: General power distribution protection scenarios that do not require precise parameter adjustment.

2️⃣ Micrologic (Electronic Trip Unit)

Working Principle: Digital circuits perform monitoring and protection, providing multiple protection functions.

Features:

Wide setting range (0.4~1In) and high accuracy (±15%).

Provides maintenance information such as contact wear and operation count.

Supports multiple protection functions: sovraccarico, short-circuit short delay, earth fault, ecc.

Application: Industrial and commercial power distribution that requires high protection accuracy and intelligent monitoring.

Scenari applicativi

Industrial Power Distribution Systems: Protection for mechanical equipment and production lines.

Commercial Buildings: Main circuits in shopping malls and office buildings.

Data Centers: Power systems requiring high-reliability protection.

Residential Power Distribution: Main switches providing comprehensive protection.

Generator Protection: Supported by special models (TM-G).

Key Advantages

  1. High Reliability: Adopts a double-rotating contact structure with a breaking capacity of up to 150kA to ensure system safety.
  2. Modular Design:

Multiple trip units optional to adapt to different load characteristics.

Rich accessories: auxiliary contacts, alarm contacts, shunt trip devices, ecc.

Electric operating mechanism (≥160A) supports remote control.

  1. Digital Characteristics:

Electronic trip units provide precise protection and fault diagnosis.

Supports integration with the Schneider EcoStruxure system to realize smart grid management.

Selection Points

  1. Rated Current Selection: ≥ Calculated load current and ≤ 250A.
  2. Breaking Capacity Selection:

General civil/commercial use: 36IL (Type F) is sufficient.

Industrial environments: 50IL (Type N) or higher.

Special occasions (per esempio., power plants): Consider 70-100kA (Type H/S).

  1. Trip Unit Selection:

Simple power distribution: TMD (cost-effective).

Critical loads: Micrologic (intelligent protection).

  1. Pole Number Selection:

Three-phase equipment: 3P.

Three-phase four-wire system: 4P.

Prezzo di riferimento

TMD Type (36kA/50kA): Approximately 1,600-2,500 RMB

Micrologic Type: Approximately 2,500-5,000 RMB (depending on function complexity)

Riepilogo

The Schneider NSX250A circuit breaker is a high-performance and high-reliability medium-voltage power distribution protection device. It is suitable for various industrial and commercial scenarios and offers multiple options ranging from basic thermomagnetic protection to intelligent electronic protection. When selecting, the appropriate model and configuration should be determined based on actual load characteristics, short-circuit current levels, and protection requirements

Do you need me to further optimize the translation of certain professional terms in this document, or generate a PDF version of the English translation for easier sharing and storage?

Prec:

Prossimo:

Lascia una risposta