(Telemecanique OsiSense XS4) Tipo di prodotto: M30 Non-Flush Analogue 4–20mA Inductive Proximity Sensor ✅ Model Code Definition XS4: XS4 series inductive proximity sensor P: Custodia in plastica PBT 30: M30 thread A: Analogue output B: Cable connection 1: Alimentazione CC 20: 4–20mA current output 📌 Core Technical Specifications Item Parameter Outline Cylindrical M30×1.5, overall length 53 ...

  • Dettagli del prodotto

(Telemeccanica OsiSense XS4)

Tipo di prodotto: M30 Non-Flush Analogue 4–20mA Sensore di prossimità induttivo

✅ Definizione del codice modello

XS4: XS4 series inductive proximity sensor

P: Custodia in plastica PBT

30: M30 thread

UN: Uscita analogica

B: Cable connection

1: Alimentazione CC

20: 4–20mA current output

📌 Core Technical Specifications

ArticoloParametro
ContornoCylindrical M30×1.5, overall length 53 mm
MontaggioMontaggio non a incasso (flush installation not allowed)
Distanza di rilevamento nominale Sn15 mm (effective linear range: 1.5 ~ 15 mm)
Tensione di alimentazione12…24 VDC, limit range 10~38 VDC
Output signal4~20mA analogue current (3-filo)
Cavo2 m di cavo in PVC, 3×0.34 mm²
Classe di protezioneIP67
Materiale dell'alloggiamentoCorpo: PBT; Volto sensibile: PPS
Precisione di ripetizione≤3% of Sr
Errore di linearità±2 mA
Frequenza di commutazione≤300 Hz
Consumo energetico a vuoto4 mA
Temperatura operativa-25℃ ~ +70 ℃
CertificazioniCE, UL, CSA

🔌 Wiring Definition (3-cavo centrale)

Marrone: CC+ (Potere positivo)

Blu: DC(Potere negativo)

Nero: 4~20mA signal output → connect to PLC analogue AI current input channel

Principio di funzionamento: The closer the metal target is to the sensor, the higher the output current (rising from 4mA to 20mA).

15 mm distance = 4 mA; 1.5 mm distance = 20 mA.

Used for continuous displacement feedback and closed-loop control, not just discrete on/off switching.

📎 Typical Applications

  1. Continuous position closed-loop feedback for hydraulic cylinders / pneumatic actuators (hydraulic presses, tooling clamps, cilindri di sollevamento)
  2. Workpiece thickness & gap measurement, material level monitoring
  3. Continuous position feedback for manipulator soft limit & deceleration control
  4. Metal workpiece distance detection on conveyor lines
  5. Foot pedal position feedback (XS4P18ABxx of the same series is widely used for XPE foot pedals)

⚠️ Installation Notes & Riferimento a modelli incrociati

  1. Strictly use non-flush mounting. No metal close to the sensor body, otherwise the sensing range will shrink.
  2. Set the PLC AI module to 4–20mA current mode, not voltage input.
  3. Same analogue sub-series comparison:

XS4P30AB110: 0~10V voltage output

XS4P30AB120: 4~20mA current output (questo modello, mainstream type)

  1. Domestic alternative requirement: M30 non-flush, 4–20mA analogue inductive proximity sensor, Sn=15 mm, 12–24 VDC supply.

📄 Supporting Documents

Original datasheet, schemi elettrici, and PLC AI calibration examples are available on request.

XS4P30AB120 (M30, Sn15mm, 4–20mA Analogue Inductive Sensor) Field Application Cases

Core feature: Non-flush installation, metal target only, continuous distance output (1.5mm=20mA; 15mm=4mA). It is not a simple limit switch; ideal for continuous position feedback, PID closed-loop control, gap & thickness monitoring. IP67 rated for dusty, oily workshop environments.

Caso 1: Closed-loop position feedback for hydraulic / pneumatic cylinders (stazioni idrauliche, machine tool presses, construction machinery)

Working condition: Presse, clamping jigs, cilindri di sollevamento. Real-time rod position acquisition for PLC PID speed regulation, soft stop and buffer deceleration to avoid mechanical impact.

Installazione: Fix XS4P30AB120 at the cylinder tail; mount a square steel target (45×45mm standard target) on the piston rod end. Keep the sensor axially aligned with the target, and keep the working stroke within 1.5~15 mm.

Logica di controllo: 4mA = 15 mm (fully retracted); 20mA = 1.5 mm (fully extended). The PLC converts current value to displacement and triggers speed reduction when reaching preset positions.

Vantaggi: Lower cost than pull-wire displacement sensors, olio & dust resistant, simple installation for short-stroke cylinder buffering control.

  1. DC 3-wire Discrete Output (P Series, PNP / NPN for PLC Digital Input)

1) PNP Output (Positive switching)

XS4P30PB340: NO normalmente aperto, 12~24 VCC, 2cavo da m

XS4P30PB370: NC normalmente chiuso, 12~48VDC, 2cavo da m

XS4P30PC410: NA+NC (1NA+1NC), 12~24 VCC, 4-wire cable

XS4P30PB340D: NO normalmente aperto, Connettore M12

XS4P30PB370D: NC normalmente chiuso, Connettore M12

2) NPN Output (Negative switching)

XS4P30NB340: NPN NO normally open

XS4P30NB370: NPN NC normally closed

III. 2-wire AC/DC Universal (Serie M, suitable for relay circuits)

XS4P30MA230: NO normalmente aperto, 24~240 V CA/CC, 2cavo da m, IP68

XS4P30MB230: NC normalmente chiuso, 24~240 V CA/CC

Cable extension suffix: L1=5m, L2=10m (per esempio. XS4P30MA230L1)

  1. XS4P30AB Analogue Sub-series (Soltanto 2 models available)
ModelloSegnale di uscitaTensione di alimentazioneApplicazione
XS4P30AB1100~10V voltage24~48VDCPLC analogue voltage AI channel
XS4P30AB1204~20mA di corrente12~24 VCCPLC analogue current AI channel (modello tradizionale)
  1. Suffix Options for Ordering

L1: Cable extended to 5 M

L2: Cable extended to 10 M

D: Replace cable with M12 4-pin connector

K: Extended body (overall length 70 mm)

  1. Quick Selection Guide for XS4P30 Series
  2. Displacement closed-loop, livello materiale & gap measurement → XS4P30AB120 (4–20mA)
  3. Position limit with digital switching signal → PB340 / MA230
  4. Voltage analogue signal acquisition → XS4P30AB110

✅ Original Accuracy Specifications for XS4P30AB120 (Standard steel target 45×45×1 mm, 25℃)

  1. Errore di linearità: ±2 mA

Full span 4~20mA (16mA total range), effective travel 1.5~15 mm (13.5 corsa mm).

±2mA corresponds to ±1.69 mm linear deviation.

  1. Precisione di ripetizione: ≤3% Sr

Sr=15 mm → maximum repeat error ≤0.45 mm.

Senso: Readout fluctuation will not exceed 0.45 mm when repeatedly positioning at the same spot.

  1. Deriva della temperatura (output current drift): Massimo 10% FS (full scale) across -25~+70℃

Range note: Linear performance and accuracy are only guaranteed within the effective working range of 1.5 mm (20mA) ~ 15 mm (4mA).

📌 Plain Summary

Excellent repeatability: ca. 0.45 mm, suitable for repeated positioning control.

Moderate linear deviation: ±1.7 mm, not for micron-level precision measurement; it is an industrial coarse-range analogue proximity sensor.

Additional A/D conversion error will be introduced by the PLC AI module, further reducing overall system accuracy.

⚠️ Key Factors Affecting Measurement Accuracy

Target material must be mild steel; stainless steel or aluminium will change sensitivity and increase error.

Strict non-flush mounting; no surrounding metal interference.

Strong welding electromagnetic interference, vibration and wide temperature swings will aggravate drift.