Schneider XY2CH13250 Latching Emergency-Stop Rope-Pull Switch - Contattore,interruttore automatico,sensore,Codificatore,PLC,Convertitore

Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Di Contatto |

 Schneider XY2CH13250 Latching Emergency-Stop Rope-Pull Switch - Contattore,interruttore automatico,sensore,Codificatore,PLC,Convertitore

elettrico/

Schneider XY2CH13250 Latching Emergency-Stop Rope-Pull Switch

Spiegazione del modello: XY2CH series, booted push-button reset, 1NC+1NO, without indicator lamp; XY2CH13250H29 = cable entry thread changed to M20; standard version is Pg13.5. Comparison with XY2CH13290: 13250 features only one safety NC contact; 13290 adopts dual-channel safety with two NC contacts — this is the core difference. Basic Specifications Item Parameter Contact Configuration 1NC (sicurezza) ...

  • Dettagli del prodotto

Spiegazione del modello: XY2CH series, booted push-button reset, 1NC+1NO, without indicator lamp; XY2CH13250H29 = cable entry thread changed to M20; standard version is Pg13.5.

Comparison with XY2CH13290: 13250 features only one safety NC contact; 13290 adopts dual-channel safety with two NC contacts — this is the core difference.

Specifiche di base

ArticoloParametro
Configurazione dei contatti1NC (sicurezza) +1NO (segnale), slow‑break positive‑opening contacts
Modalità di ripristinoDust‑protected manual booted push‑button reset; latches after actuation, no auto‑reset
Massimo. Rope Length30 M
Classe di protezioneIP65
Materiale dell'alloggiamentoZamak die‑cast zinc‑alloy body, stainless‑steel cover
Ingressi cavi3 × Pg13.5; H29 suffix variant: 3 × M20
Terminal Tightening Torque0.8‑1.2 N·m, conductor size 0.5‑1.5 mm²
Resistenza meccanica800 000 operazioni; B10d = 4 000 000
Temperatura operativa‑25 ℃ ~ +70 ℃
Safety Note (single‑channel hardware)To achieve PL e / Cat.4 / SIL3, safety‑relay contact‑short‑circuit monitoring is mandatory. Direct single‑contact wiring max. achieves PL c only.

Terminal Assignment

Terminale n.ContattoStato (non‑actuated)After rope‑pull actuation
21‑22NC Safety Normally‑ClosedChiusoAprire (positive opening)
13-14NO Signal Normally‑OpenAprireChiuso

⚠️ Critico: Only one safety NC contact; no second hardware safety channel.

Normal state: 21-22 Chiuso, 13-14 aprire. Pulling the rope triggers mechanical latching: 21-22 si apre, 13-14 chiude. Restore by pressing the blue reset push-button.

Wiring Schemes

Schema1: High-Safety Level (PL e requires safety-relay monitoring)

  1. Filo 21-22 (NC) to one input channel of safety relay.
  2. Filo 13-14 (NO) to PLC DI for alarm feedback signal.

Since the hardware provides only one NC channel, Category 4 / PL e can only be achieved when the safety relay implements contact short-circuit monitoring. Without monitoring, max achievable safety level is PL c.

❗Do NOT externally parallel contacts; hardware only supplies one safety contact.

Schema2: Low-risk general-purpose equipment (PL e not satisfied)

Filo 21-22 in series into equipment emergency-stop circuit; 13-14 for alarm feedback.

Suitable for light-duty general-purpose conveyors. Strictly prohibited for high-risk conveyor systems.

Precauzioni per il cablaggio

  1. Use only one cable entry; fit sealing plugs on the remaining two unused entries, otherwise IP65 protection is lost.
  2. Connect metal housing reliably to PE protective earth.
  3. Tighten terminals strictly to 0.8-1.2 N·m to avoid loose connections.

Installazione meccanica

Mechanical installation requirements are identical to XY2CH13290. Refer to the full installation manual below:

  1. Max rope span 30 m; use φ3-5 mm plastic-coated steel wire rope.
  2. End-position tension spring is mandatory. Rope breakage shall also trigger emergency stop.
  3. First deflection pulley shall be mounted 100 mm away from switch body. Install rope clamps/support points every 5 m.
  4. Mount onto rigid metal brackets only; allow slight rope sag — do not over-tension nor allow excessive slack.

Pre-power-on Commissioning (de-energised, multimeter test)

  1. Reset completed: 21-22 Chiuso, 13-14 aprire.
  2. Pull rope to trigger latching: 21-22 aprire, 13-14 Chiuso.
  3. Press reset push-button to restore contact states.
  4. Test actuation at multiple positions all along the rope path to confirm reliable triggering even at far-end positions.

Confronto dei modelli: XY2CH13250 vs XY2CH13290

ModelloConfigurazione dei contattiSafety ChannelApplicazione tipica
XY2CH132501NC+1NOSingle‑channelLow‑risk equipment, cost‑optimised; safety‑relay monitoring required for high‑level safety
XY2CH132902NC+1NODual‑channel on‑boardTrasportatori a nastro, high‑risk material‑handling lines; industry‑preferred variant for direct dual‑channel safety‑relay input

Selection Reminder: Prefer 13290 for belt conveyors and heavy-duty lines; 13250 is acceptable for light-duty general-purpose machines.

Equivalent Replacement Models

  1. Originale Schneider variant: XY2CH13250H29 (M20 thread version)
  2. Alternative domestiche:

ELCO SR1-SN (1NC+1NO)

Schmersal ZQ700-11

Risoluzione dei problemi comuni

  1. Unintended nuisance tripping: Excessive rope tension, bracket vibration. Reduce tension via turnbuckle; reinforce mounting structure.
  2. No actuation from far-end pull: Insufficient rope tension, seized deflection pulleys. Adjust tension; service pulleys.
  3. Cannot reset after tripping: Persistent tensile load remains on rope. Release rope residual tension before pressing reset button.

Tipo di prodotto: Latching emergency-stop rope-pull safety switch. Pulling the steel wire rope triggers emergency stop with mechanical latching; manual reset is mandatory. Applied to long-run conveyors, linee di assemblaggio, macchine confezionatrici, belt conveyors and other machinery safety protection.

General Core Specifications

ArticoloParametro
Classe di protezioneIP65
Massimo. Rope Length30 M
Resistenza meccanica800 000 operazioni
Materiale del corpoZamak die‑cast zinc alloy, stainless‑steel cover
Ingressi cavi3 × Pg13.5 (M20 for certain variants), terminali a vite
Coppia terminale0.8‑1.2 N·m
Valutazione di sicurezzaPL e / Cat.4 / SIL3 (requires compatible safety relay and correct wiring)
Caratteristiche del contattoSlow‑break, positive‑opening safety contacts
Housing ColourRed RAL 3000

Model Naming & Main XY2CH Variants

XY2CH + numeric suffix. Suffix defines contact configuration, reset type, pilot-lamp option and thread specification.

  1. Reset Types

131xx: Flat push-button reset

132xx: Booted dust-protected push-button reset (most common industrial type)

134xx: Key-operated reset

  1. Configurazioni dei contatti

XY2CH13250: 1NC+1NO, booted push-button reset

XY2CH13270: 2NC, dual safety normally-closed contacts

XY2CH13290: 2NC+1NO (più popolare; 2 safety NC + 1 signal NO)

XY2CH13450: 1NC+1NO, key-reset

XY2CH13293: 2NC+1NO, with 24 V pilot lamp

Suffix H29 = cable-entry thread changed to M20; default = Pg13.5.

Principio di funzionamento

  1. Pull steel wire rope → internal mechanism latches mechanically; safety NC contacts positive-open.
  2. Machine shuts down; no automatic reset.
  3. After fault clearance, reset via push-button / chiave; contacts restore for machine restart permission.

⚠️ Nota: Rope-run ends must be fitted with tension springs, rope clamps and deflection pulleys. Avoid over-tightening or excessive slack. Rope-clamp spacing ≤ 5 m recommended.

Applicazioni tipiche

Trasportatori a nastro, linee di produzione, linee di confezionamento, sistemi di smistamento, long workstations, mining conveying equipment. Operators can trigger emergency stop by pulling the rope anywhere along the protected span.

XY2C Family Series Differentiation

XY2CH: Zamak zinc-alloy body, stainless-steel cover, max 30  m rope length, IP65, high mechanical endurance.

XY2CE: Custodia in plastica, economy-grade, max 2 × 50  m bidirectional rope pull.

XY2CJ: Higher-grade IP66/IP67 protection for heavy-dust and wash-down environments.

Domestic-brand Reference Replacements

ELCO: SR-series rope-pull E-stop switches

Omron: D4A-N rope-pull switches

Contrinex / Schmersal: ZQ-series rope-pull safety switches

General Fault-Finding

  1. Frequent nuisance tripping: Excessive rope tension, seized pulleys, deformed mounting brackets.
  2. Ripristino non riuscito: Mechanism jammed; residual rope tension not released.
  3. Open-circuit safety loop: Terminali allentati; verify tightening torque 0.8-1.2 N·m.

Schneider XY2CH13290 (Telemecanique Rope-Pull Emergency-Stop Switch)

Contatti: 2NC+1NO, booted push-button reset, no pilot lamp; max rope length 30  m; IP65; Pg13.5 cable entries. Suffix H29 = M20 thread.

  1. Terminal Assignment
Terminale n.Contact PropertyScopo
21‑22NC#1 (Safety Normally‑Closed 1)Safety‑loop channel 1, positive‑opening
31‑32NC#2 (Safety Normally‑Closed 2)Safety‑loop channel 2, positive‑opening
13-14NO (Normalmente aperto)PLC alarm / status feedback signal

Non-actuated state: 21-22 Chiuso, 31-32 Chiuso, 13-14 aprire.

Rope-pull latching: 21-22 E 31-32 open simultaneously; 13-14 chiude. Reset only via blue local push-button.

  1. Wiring Schemes

Scheme A: Safety-relay connection (achieve PL e / Cat.4 / SIL3 — Recommended)

  1. Feed independent dual NC channels 21-22 E 31-32 separately into dual-channel safety-relay inputs. Never externally short-circuit the two NC contacts — this invalidates safety rating.
  2. Filo 13-14 NO contact to PLC digital input for rope-pull-triggered alarm.
  3. Coppia di serraggio del terminale: 0.8-1.2 N·m. Conduttore: 0.34-1 mm² single-wire / max 0.75 mm² for two-wire parallel.
  4. Cable glands: 3 × Pg13.5; use one only; seal remaining two with blanking plugs to preserve IP65.

Scheme B: Simplified stand-alone wiring (PL e not satisfied, for basic stop-function only)

Wire both NC contacts in series into emergency-stop circuit; NO for alarm output. Cannot reach Category 4; only for low-hazard machinery.

⚠️ Importante: This is a mechanically latched device. It will NOT auto-reset after rope-pull actuation; manual push-button reset is required.

  1. Mechanical Installation Key-Points
  2. Steel wire rope: φ3-5 mm plastic-coated; max total length 30  m; fit tension springs at both ends.
  3. Rope clamps: install every ≤ 5  m; add deflection pulleys to prevent rope-to-housing friction.
  4. Tensione della corda: avoid over-tightening (nuisance tripping) and excessive slack; permit minor sag.
  5. Staffa di montaggio: rigid metal construction; no flexible supports. Switch can accept rope entry from left or right side.
  6. Temperatura ambiente: −25 ℃ ~ +70 ℃.
  7. Dimensioni complessive (mm)

Corpo: W 68 × H 95 × D 201 (including reset button and rope-pull lever mechanism)

Fori di montaggio: two M8 mounting holes on both sides.

  1. Original Schneider Equivalent-variant Selection Table
ModelloContattiResetCable‑entry ThreadOsservazioni
XY2CH132702NCBooted push‑buttonPg13.5Pure dual‑safety‑channel, no NO signal contact
XY2CH132501NC+1NOBooted push‑buttonPg13.5Single safety channel
XY2CH132932NC+1NOBooted push‑buttonPg13.5With 24 V pilot lamp
XY2CH134902NC+1NOKey‑resetPg13.5Key‑unlock required for reset
XY2CH13290H292NC+1NOBooted push‑buttonM20Thread changed to M20
  1. Pin-to-pin Compatible Domestic Replacements
  2. Schmersal ZQ 900-22 (2NC+1NO, ripristino tramite pulsante)
  3. ELCO SR2-SN (2NC+1NO)
  4. Contrinex SN21-RPL-30M

Promemoria di sostituzione: Verifica la configurazione dei contatti, reset type, max rope length and protection rating.

  1. Risoluzione dei problemi
  2. Frequent nuisance tripping: Excessive rope tension, seized pulleys, deformed brackets, heavy machine vibration. Reduce rope tension; inspect deflection pulleys.
  3. Cannot reset after tripping: Residual rope tension keeps mechanism locked. Release rope tension before pressing reset button.
  4. Intermittent open safety circuit: Under-torqued terminals. Retighten terminals to 0.8-1.2 N·m; re-crimp conductors.
  5. Water ingress damage: Unused cable entries not sealed with blanking plugs.

Complete Installation Operating Guide for Schneider XY2CH-Series Rope-Pull Emergency-Stop Switches

Modelli applicabili: XY2CH13290, XY2CH13270, XY2CH13250 etc. Complies with EN/ISO 13850, IEC 60947-5-5, Machinery-Safety Directives.

⚠️ Safety Precondition: Perform all installation, wiring and commissioning with equipment de-energised under Lock-Out-Tag-Out (CUORE). This is a tension-type rope-pull switch; proper pre-tension is required. Rope breakage shall also trigger emergency-stop protection.

  1. Preparazione pre-installazione

1.1 Utensili & Accessories List

CategoriaContenuto
UtensiliM8/M6 spanner, cross‑head screwdriver, cacciavite dinamometrico, multimetro, wire cutters
Accessori Obbligatoriφ3‑5 mm plastic‑coated steel wire rope, rope clamps, deflection pulleys, end‑position tension spring (obbligatorio), turnbuckle, rigid metal mounting brackets, sealing blanking plugs
Electrical Cables0.34‑1 mm² control cables; terminal torque 0.8‑1.2 N·m; PE protective‑earth conductor for metal housing

1.2 Environmental Verification

  1. Temperatura operativa: −25 ℃ ~ +70 ℃; IP65 rating. Avoid heavily corrosive and high-impact locations.
  2. Max effective rope-protected length 30  m. Install an additional rope-pull switch if span exceeds this limit.
  3. Operating rope height above ground: 0.6-1.1 M, easily reachable by personnel; no obstacles obstructing the rope path.
  4. All mounting brackets must be rigid metal. Thin-sheet / flexible supports are forbidden; vibration will cause false triggering.
  5. Mechanical-body Mounting Procedure
  6. Secure the switch body

Fasten with M8 bolts through the two side mounting holes onto rigid machine frame; tightening torque 4 N·m. Align switch rope-exit direction with rope routing; do not twist the rope-pull lever mechanism.

Maintain 100 mm distance between switch body and first deflection-support point. Larger distance causes insufficient actuation stroke.

  1. Fit deflection pulleys

Fit deflection pulleys wherever the rope changes direction. Total deflection-angle sum ≤ 180°. Sharp bends and hard kinks are prohibited.

Install support / rope-clamp assemblies every 5 m along straight runs to limit rope sag.

Pulleys shall rotate freely without binding. Rope must not rub against machine frames or enclosures.

  1. Steel-wire-rope & end-spring assembly (passaggio critico)

1) Attach one rope end to the XY2CH rope-pull eyelet.

2) Thread rope through all deflection pulleys.

3) Fit end-position tension spring at the far rope end. Anchor the spring’s opposite end to rigid machine frame. Omission of this spring is a major safety hazard — pulling towards the switch will fail to trigger E-stop.

4) Secure rope with at least two rope clamps. Do not clamp over the sheath-stripping transition zone.

5) Adjust total rope tension via turnbuckle: keep rope moderately taut with minor sag. Do not over-tighten; do not allow excessive slack.

Over-tension: vibration-induced nuisance tripping. Under-tension: no reliable actuation from far-end positions.

  1. Mechanical acceptance check

Rope free of twist, kinks and abrasion. Avoid large-area sheath stripping to prevent corrosion.

Full-rope-travel movement is smooth without binding.

Verificare: rope breakage will cause spring retraction and trigger emergency-stop.

  1. Electrical Wiring Procedure

XY2CH13290 terminals: 21-22 NC1; 31-32 NC2; 13-14 NO. Metal housing includes PE earth terminal. Housing must be reliably connected to PE protective earth.

  1. Remove four cover screws and open housing.
  2. Cable-entry handling:

Standard units: 3 × Pg13.5 threaded entries; H29 variants: M20.

Use only one entry for control-cable feed-through. Tighten original sealing blanking plugs on the other two unused entries (torque 1 N·m). Failure destroys IP65 protection and causes water ingress.

  1. Cablaggio dei terminali (for PL e / Cat.4 / SIL3 safety-loop):

Feed dual safety NC contacts 21-22 E 31-32 into separate safety-relay dual-channel inputs. Never externally short-circuit the two NC contacts — safety rating will be lost.

Filo 13-14 NO contact to PLC input for rope-pull-trigger-alarm signal.

Sezione del conduttore: single-wire 0.34-1 mm²; max 0.75 mm² for two-wire parallel. Terminal tightening torque 0.8-1.2 N·m.

  1. Connect PE protective-earth wire to housing earth terminal for EMC and shock-hazard protection.
  2. Refit cover and evenly tighten four cover screws.

❗Simplified wiring (not for high-hazard machinery): Series-connect both NC contacts into general-purpose emergency-stop circuit. This provides only basic stop-function and does not achieve Category 4 safety rating. For low-risk equipment only.

  1. Pre-power-on Static Commissioning (de-energised, multimeter measurements)
  2. Normal reset-completed state

Multimeter readings: 21-22 Chiuso, 31-32 Chiuso; 13-14 aprire.

  1. Manually pull rope to trigger mechanical latching

Multimeter readings: 21-22 aprire, 31-32 aprire; 13-14 Chiuso.

Latching is maintained; contacts will not auto-recover.

  1. Press blue booted reset push-button; contacts return to initial status.
  2. Simulate actuation at multiple positions along rope path: near switch, mid-span and far-end. Reliable latching actuation must occur at every position.

Poor far-end actuation: reduce rope tension or check for seized pulleys.

  1. Simulate rope breakage: spring retraction must trigger emergency-stop latching.
  2. Live-machine Functional Test
  3. Energise machine and safety-relay system.
  4. Test 1: Pull rope near switch → controlled machine shutdown; safety-relay fault indication. Manual reset at switch body AND safety-relay reset are required before machine restart. No automatic-power-on after supply restoration permitted.
  5. Test 2: Pull rope at mid-span and far-end positions. Confirm controlled emergency-stop at all points.
  6. Test 3: Verify PLC alarm signal (13-14 NO) correctly reports rope-pull-trigger events.
  7. Installation Acceptance Criteria
  8. Meccanico: Rigid mounting brackets, free-running pulleys, intact tension springs, correct rope tension, no mechanical interference or friction.
  9. Protezione: All unused cable entries sealed with blanking plugs; cover screws tightened; PE-earth connection intact.
  10. Elettrico: Dual-channel NC contacts fed independently to safety-relay inputs (no external short-circuit). Multimeter test sequences fully compliant.
  11. Funzionale: Reliable latching E-stop from any rope-span position; manual-only reset; rope-break triggers emergency-stop.
  12. Installation-related Fault-Finding Table
Fenomeno di guastoCausa ultimaAzione correttiva
Random uncommanded trippingExcessive rope tension; vibrating pulleys / brackets; insufficient bracket rigidityReduce tension via turnbuckle; reinforce supports; service seized pulleys
No actuation from far‑end rope positionsInsufficient rope tension; excessive distance to first support point; seized pulleysAdjust rope tension; set first support at 100  mm; repair pulleys
Cannot reset after trippingPersistent tensile load remains on ropeRelease residual rope tension before pressing reset button
Intermittent safety‑loop continuityUnder‑torqued terminals, loose conductorsRetighten terminals to 0.8‑1.2 N·m; re‑terminate conductors
Water‑induced device damageUnused cable entries without blanking plugsFit original sealing plugs on all unused threaded entries
  1. Periodic-maintenance Requirements (to be documented in machine-maintenance manual)
  2. Weekly visual inspection: rope abrasion, loose rope clamps, deformed springs, loose mounting brackets.
  3. Monthly full-functional test: trigger emergency-stop at multiple rope-span positions.
  4. Ispezione trimestrale: re-verify terminal torque and PE-earth integrity; inspect rope-sheath wear.
  5. Immediately replace steel-wire rope if wire-strand breakage or sheath damage is observed.

Nota integrativa: XY2CH shall not be treated as a general-purpose limit switch. Permanent rope anchoring without end-position tension spring constitutes a serious safety violation.