Siemens 3VA9267-0HA20 Molded Case Circuit Breaker - Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari

Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Di Contatto |

 Siemens 3VA9267-0HA20 Molded Case Circuit Breaker - Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari

interruttore automatico/

Siemens 3VA9267-0HA20 Molded Case Circuit Breaker

Model Code Interpretation Segment 3VA 9 267 -0HA 20 Meaning Product series: SENTRON 3VA molded case circuit breaker system Accessory category: 3VA9 series accessories Accessory type: MO320 Front-mounted Motor Operator Control voltage code: 110-230V e / 110-250V DC Applicable breaker rating: 3VA2 100/160/250A Description Flagship low-voltage power distribution series of Siemens, covering MCCBs from 16A ...

  • Dettagli del prodotto

Interpretazione del codice modello

Segmento3VA9267-0HA20
SensoSerie di prodotti: SENTRON 3VA molded case circuit breaker systemAccessory category: 3VA9 series accessoriesTipo di accessorio: MO320 Front-mounted Motor OperatorControl voltage code: 110-230V e / 110-250A DCApplicable breaker rating: 3VA2 100/160/250A
DescrizioneFlagship low-voltage power distribution series of Siemens, covering MCCBs from 16A to 1600AAccessory system specially designed for 3VA series circuit breakersMO320 motor operator, supporting remote closing and trippingWide voltage design, compatible with various power supply systemsSuitable for 3VA2 circuit breakers rated at 100A, 160A and 250A
  1. Principali Specifiche Tecniche
Categoria dei parametriDati tecniciOsservazioni
Informazioni generali
Nome del prodottoMO320 Front-mounted Motor OperatorFor 3VA2 series molded case circuit breakers
Ordine n.3VA9267-0HA20Standard commercial model
Stato del prodottoAttivo (PM300)Defined by Siemens Product Lifecycle Management System
Parametri Elettrici
Tensione di controllo110-230V e (50/60Hz) / 110-250A DCWide voltage compatibility
Rated Apparent Power250VAPower consumption of the operator
Tempo di funzionamento (Chiusura & Inciampo)Typical 1 secondoMechanical response time
Parametri meccanici
Dimensioni (L×A×P)105mm×75mm×132mmCompact design to save cabinet space
Pesoca. 846GEasy for installation and maintenance
Terminal CapacityFor 1.5-2.5mm² conductorsSolid, stranded and fine-stranded conductors applicable
Wire Stripping Length7mmCompliant with IEC standards
Coppia di serraggio0.36-0.44N·mEnsure reliable connection
Parametri Ambientali
Temperatura operativa-25°C fino a +70°CSuitable for industrial environments
Temperatura di conservazione-40°C fino a +80°CWide temperature range for storage
Protezione dall'ingressoIP30Conforme alla norma CEI 60529
  1. Full Range of MO320 Motor Operators
ModelloTensione di controlloApplicable Breaker SeriesOsservazioni
3VA9267-0HA1024-60A DC3VA2 100/160/250Low voltage DC type
3VA9267-0HA20110-230V e / 110-250A DC3VA2 100/160/250Universal wide voltage type (Current Model)
3VA9157-0HA1024-60A DC3VA1 100/160For 3VA1 series
3VA9157-0HA20110-230V e / 110-250A DC3VA1 100/160For 3VA1 series
3VA9467-0HA1024-60A DC3VA2 400/630For high-current 3VA2 breakers
3VA9467-0HA20110-230V e / 110-250A DC3VA2 400/630For high-current 3VA2 breakers
3VA9257-0HA1024-60A DC3VA2 100/160Side-mounted type
3VA9257-0HA20110-230V e / 110-250A DC3VA2 100/160Side-mounted type
  1. Concorrente & Equivalent Model List
MarcaModelloApplicable BreakerTensione di controlloDescrizione della sostituzione
Siemens3VA9267-0HA103VA2 100/160/25024-60A DCLow-voltage alternative within the same series
Schneider ElectricLV432642NSX 400-630380-415V eFunctional cross-brand replacement
ABBCD2-400T1-T6 Series220V CA/CCFunctional cross-brand replacement
ABBOTM-D250Tmax Series24-250V CA/CCFunctional cross-brand replacement
EatonNZM-E200NZM Series24-230V CA/CCFunctional cross-brand replacement
  1. Ambienti applicativi & Casi di settore

5.1 Recommended Application Scenarios

Sistemi di Automazione Industriale: Remote closing and tripping of motor circuits for production line automatic control

Centri dati: Remote operation of breakers for UPS systems to improve power supply reliability

Edifici commerciali: Remote control of breakers for emergency lighting and fire protection systems, complying with safety regulations

Infrastrutture energetiche: Remote monitoring of breakers for photovoltaic inverters and energy storage systems to boost operation efficiency

Water Treatment Facilities: Automatic switching of pump circuits to realize unattended operation

5.2 Scenari non consigliati

Explosive Hazardous Areas: Additional explosion-proof certification is required; not suitable for direct use in IIC explosive zones

High Electromagnetic Interference Environments: Extra electromagnetic shielding is needed; not recommended near unshielded high-frequency equipment

Severe Vibration Environments: Not applicable where vibration acceleration exceeds 5g, which may impair mechanical reliability

5.3 Casi applicativi tipici

Caso 1: Automobile Manufacturing Plant

Applicazione: Remote control of power circuits for welding robots

Configurazione: 3VA2 250A MCCB + 3VA9267-0HA20 Motor Operator + PLC Control System

Vantaggi: Realize automatic power-off protection for production lines, reduce manual operation and increase productivity by 15%

Caso 2: Large-scale Data Center

Applicazione: Remote management of Power Distribution Units (PDU) in server cabinets

Configurazione: 3VA2 160A MCCB + 3VA9267-0HA20 + Building Management System (BMS)

Vantaggi: Remote monitoring and circuit switching, quick fault isolation; Mean Time To Repair (MTTR) reduced to less than 5 minuti

Caso 3: Hospital Operating Room

Applicazione: Emergency control of dedicated power circuits for medical equipment

Configurazione: 3VA2 100A MCCB + 3VA9267-0HA20 + Emergency Control System

Vantaggi: Fast power switching for operating rooms, ensure safe operation of medical devices; conforme alla CEI 60601 medical standards

  1. Suggerimenti per la selezione & Quick Reference Rules

Selection Rhythm (For Reference)

Model 3VA9267-0HA20,

Covers 110 to 230V AC/DC,

Matches 3VA2 100/160/250A breakers,

Front-mounted MO320 design,

One second for remote switch action,

Rated power at 250VA,

Dimension 105×75×132mm,

Ideal for industrial and building applications.

Quick Reference Rules

  1. Corrispondenza della tensione: HA20 = Wide voltage (110-230V e / 110-250A DC); HA10 = Low voltage (24-60A DC)
  2. Serie applicabile: 9267 = 3VA2 100/160/250A; 9157 = 3VA1 100/160A; 9467 = 3VA2 400/630A
  3. Tipo di montaggio: 9267 = Front-mounted; 9257 = Side-mounted
  4. Parametri fondamentali: 1-second operating time, 250VA power rating, compatible with 1.5-2.5mm² conductors
  5. Risoluzione dei problemi & Soluzioni
Fenomeno di guastoPossibili causeSoluzioni
Failure to close or tripTensione di controllo anomalaVerify the voltage is within 110-230V AC / 110-250A DC
Loose wiring terminalsRetighten terminals with torque of 0.36-0.44N·m
Inceppamento meccanicoCheck connection between operator and breaker, rimuovere oggetti estranei
Slow closing/trippingInsufficient power supply capacityEnsure control circuit power ≥ 250VA
Excessively low ambient temperatureApply heating measures when temperature is below -25°C
Rumore di funzionamento eccessivoMechanical wearInspect transmission parts and replace grease if necessary
Unstable installationRe-fix the operator and ensure flat mounting surface
  1. Key Features Summary
  2. Ampia compatibilità di tensione: 110-230V e / 110-250A DC, reducing spare parts stock and procurement costs
  3. Risposta rapida: Typical 1-second operating time, meeting emergency control requirements
  4. Struttura compatta: Dimension 105×75×132mm, saving space inside switchgear cabinets
  5. Alta affidabilità: Operating temperature range from -25°C to +70°C, adaptable to harsh industrial conditions
  6. Installazione semplice & Manutenzione: Standard interface for perfect matching with 3VA2 series breakers

Typical Application Cases of Siemens 3VA9267-0HA20 (MO320 Motor Operator)

This accessory is designed for 3VA2 100/160/250A molded case circuit breakers to realize remote motorized closing and tripping. With control voltage of 110–230V AC / 110–250V DC, it is widely applied in industrial, centro dati, building and energy sectors.

  1. Automobile Welding Workshop (Automazione industriale)

Configurazione: 3VA2 250A + 3VA9267-0HA20 + PLC / Fieldbus System

Applicazione: Remote switching and automatic fault isolation for power circuits of welding robots and welders

Vantaggi: Minimize manual work, improve workshop safety; cut downtime via remote power-off during faults

  1. Large-scale Data Center (Infrastrutture)

Configurazione: 3VA2 160A + 3VA9267-0HA20 + BMS / SME

Applicazione: Centralized remote control for cabinet PDUs, UPS outputs and precision air conditioners

Vantaggi: Remote inspection and circuit operation, rapid fault location and isolation; wide voltage design compatible with global mains power

  1. Commercial Complex & Grattacieli (Smart Power Distribution)

Configurazione: 3VA2 100–250A + 3VA9267-0HA20 + Fire Alarm / BAS System

Applicazione: Interlocked control for emergency lighting, fire pumps and exhaust fans; remote power cut for energy saving during off-hours

Vantaggi: Comply with mandatory fire power cut regulations; lower operation costs and improve energy efficiency

  1. Photovoltaic & Energy Storage Power Stations (New Energy)

Configurazione: 3VA2 250A + 3VA9267-0HA20 + Power Station Monitoring System

Applicazione: Remote grid connection/disconnection and fault protection for AC sides of inverters and energy storage cabinets

Vantaggi: Adapt to wide outdoor temperature (-25°C fino a +70°C); realize remote operation and reduce on-site inspection work

  1. Hospital Operating Room & terapia intensiva (Medical Power Supply)

Configurazione: 3VA2 100A + 3VA9267-0HA20 + Medical Isolated Power System

Applicazione: Emergency switching and protection for surgical equipment and life support systems

Vantaggi: Fast switching (ca. 1 secondo), high operational reliability and compliance with medical power supply standards

  1. Trattamento delle acque & Pumping Stations (Municipal Engineering)

Configurazione: 3VA2 160–250A + 3VA9267-0HA20 + Pump Station PLC

Applicazione: Remote start/stop and overload protection for submersible pumps, blowers and chemical dosing equipment

Vantaggi: Suitable for humid and dusty environments; unattended remote control to reduce operation costs

Punti di corrispondenza principali

Applicable Breakers: 3VA2 100/160/250A (3-palo / 4-palo)

Tensione di controllo: 110–230V AC / 110–250V DC (Universal wide voltage)

Tipo di montaggio: Front-mounted (MO320), Dimensione: 105×75×132mm

Funzioni chiave: Remote closing & tripping, fault isolation; adatto per industriale, building and new energy applications

Prec:

Prossimo:

Lascia una risposta