Siemens QPL25.050B is a high-performance gas pressure switch. Designed for medium and low pressure monitoring ranging from 5-50 mbar, it features IP54 protection grade and a mechanical service life of 100,000 cicli. It is widely used for safety protection of combustion systems. Check model parameters, pressure range and mounting interface during procurement to ensure full compatibility with system requirements.
- Definizione del codice modello
| Segmento di codice | Senso | Descrizione |
| QPL | Codice serie prodotto | Basic series of Siemens gas pressure switches for gas and air pressure monitoring |
| 25 | Struttura & parametri nominali | Serie 25, rated current 6A AC, tensione nominale 250 V CA/CC, Protezione IP54 |
| 50 | Pressure adjustment range | Gamma regolabile: 5-50 mbar (0.5-5.0 kPa) |
| B | Version mark | Tipo standard, automatic reset, SPDT contact configuration |
- Parametri delle specifiche principali
| Categoria | Specifiche | Osservazioni |
| Parametri di base | ||
| Tipo di prodotto | Mechanical gas pressure switch | Safety monitoring for combustion systems |
| Ordine n. | 1117087 | Official Siemens part number |
| Adjustment Range | 5-50 mbar (0.5-5.0 kPa) | Adjustable set point |
| Max Working Pressure | 690 mbar (69 kPa) | Upper limit of continuous operating pressure |
| Switch Differential | ca. 5-10 mbar | Pressure difference between switch-on and switch-off |
| Parametri Elettrici | ||
| Tensione nominale | AC 250V / CC 250 V | Tensione operativa massima |
| Corrente nominale | AC 6A / DC 1A | Carico resistivo |
| Tipo di contatto | SPDT | 1 normalmente aperto + 1 normalmente chiuso |
| Collegamento elettrico | Terminal box compliant with DIN EN 175 301-803 | Classe 3 protezione dell'isolamento |
| Meccanico & Parametri Ambientali | ||
| Pressure Port | G1/4 internal thread (ISO228) | Center position at bottom casing |
| Measuring Port | Ø9mm, 10mm length with locking screw | For pressure calibration |
| Temperatura ambiente | -20°C~+60°C | Intervallo di temperatura operativa |
| Temperatura media | -40°C~+60°C | Applicable gas temperature |
| Grado di protezione | IP54 | Antipolvere e impermeabile |
| Mechanical Lifespan | 100,000 cicli | Switch actuation times |
| Applicable Media | Classe 1/2/3 gases & non-corrosive gas | Natural gas, liquefied petroleum gas, ecc. |
- Full QPL25 Series Model List
| Modello | Intervallo di pressione | Max Working Pressure | Osservazioni |
| QPL25.003B | 0.3-3 mbar | 690 mbar | Low pressure monitoring |
| QPL25.010B | 1-10 mbar | 690 mbar | Ultra-low pressure application |
| QPL25.050B | 5-50 mbar | 690 mbar | Standard medium-low pressure |
| QPL25.150B | 15-150 mbar | 690 mbar | Medium pressure monitoring |
| QPL25.500B | 100-500 mbar | 720 mbar | High pressure monitoring |
- Cross-brand Replacement Comparison
| Marca | Modello | Intervallo di pressione | Principali differenze | Replacement Suggestion |
| Siemens | QPL25.050B | 5-50 mbar | Original authentic product, elevata stabilità | Priority choice |
| Honeywell | C6097A | 5-50 mbar | prezzo più basso, similar response speed | Sostituzione diretta |
| Danfoss | KPI 36 | 5-50 mbar | Diversa struttura meccanica, high adjustment precision | Verify mounting dimensions |
| Dungs | LGW50A2 | 5-50 mbar | German brand, qualità affidabile | Pienamente compatibile |
| Baltur | PAMPA | 5-50 mbar | Burner dedicated, conveniente | Suitable for Baltur combustion systems |
- Risoluzione dei problemi comuni & Manutenzione
5.1 Difetti comuni & Cause
| Fenomeno di guasto | Possibili cause | Passaggi per la risoluzione dei problemi |
| No switch action under normal pressure | Improper setpoint; oxidized/damaged contacts; aging/damaged diaphragm; cablaggio allentato | Recalibrate setpoint; test contact continuity; inspect diaphragm; fasten terminals |
| No switching under abnormal pressure | Excessive switch differential; mechanical stuck; spring fatigue | Adjust differential; clean moving parts; replace spring assembly |
| Frequent contact ablation | Sovraccarico; unstable voltage; mismatched contact material | Controllare la corrente di carico; install surge suppressor; replace contact assembly |
| Inaccurate pressure reading | Blocked measuring port; deformed diaphragm; calibration error | Clean port; replace diaphragm; recalibrate with standard pressure source |
5.2 Linee guida per la manutenzione
- Safety Precaution
Cut off gas supply and release pressure
Disconnect power supply
Cool down equipment to room temperature
- Calibration Procedure
① Remove protective cover and locate adjusting screw
② Connect standard pressure source and set target value
③ Clockwise rotation increases set pressure, counter-clockwise decreases
④ Test switching action and confirm accurate trigger point
⑤ Reinstall cover and ensure tight sealing
- Component Replacement
Diaphragm: Dismount with special tools, pay attention to gasket installation direction
Contatto: Replace whole switch module instead of single contact
Primavera: Use identical specification spare part to guarantee precision
- Ambiente applicativo & Casi di settore
6.1 Scenari applicabili
✅ Recommended Applications
Safety monitoring for industrial & civil gas burners
Pressure protection system of gas boilers
Pressure control of natural gas pipelines
Gas supply system of industrial furnaces
Pressure monitoring for biogas power generation equipment
❌ Inadmissible Applications
High-pressure gas system over 690 mbar
Corrosive gas atmosphere
Medium temperature exceeding 60°C or below -20°C
Severe vibration and outdoor exposed installation without protection
6.2 Typical Industry Applications
| Industria | Applicazione | Funzione |
| HVAC | Commercial gas boiler | Monitor gas pressure to ensure combustion efficiency and safety |
| Food Processing | Baking furnace gas system | Avoid incomplete combustion caused by low pressure |
| Industria energetica | Biogas power station | Stabilize biogas pressure and protect generating units |
| Manufacturing | Ceramic kiln | Precise temperature control via gas pressure regulation |
| Commercial Kitchen | Large cooking equipment | Safety interlock to prevent gas leakage accidents |
- Suggerimenti per la selezione & Avoidable Risks
Mnemonico di selezione
QPL series for gas service, 25 stands for 6A rating
Last three digits define pressure range, B means standard auto-reset
050 model fits 5-50 mbar, G1/4 thread for installation
IP54 solid protection, match gas medium properly
Note chiave
- Pressure Matching
Keep actual working pressure within 20%-80% of adjustment range to maintain accuracy.
- Requisiti di installazione
Mount vertically with diaphragm downward to avoid condensed water accumulation.
Install filter at pressure port to prevent internal impurity damage.
Secure wiring firmly to avoid false triggering.
- Safety Regulations
Interlock with gas leakage alarm device.
Conduct regular inspection and calibration every 6 mesi.
Perform pressure and leakage test after maintenance.
- Purchase Notice
Choose genuine Siemens products; counterfeit items have unstable quality.
Keep original package and certificate for after-sales service.
Working Principle of QPL25.050B
Core principle: Air pressure deforms diaphragm, mechanical linkage drives contact on-off to realize overpressure interlock protection
- Pressure Sensing
Gas flows into inner chamber through G1/4 port and acts on rubber diaphragm, driving axial displacement with pressure variation.
- Mechanical Force Balance
Diaphragm thrust counterbalances preset spring tension. Rotate adjusting screw to change spring preload and set trigger pressure threshold.
- Linkage Actuation
When pressure rises to set value, diaphragm overcomes spring resistance and pushes rod to drive lever mechanism. Spring rebounds when pressure drops below threshold.
- Contact Switching
Lever movement switches SPDT contacts, reverses circuit status and transmits electric signal for burner start-stop and alarm interlock.
- Differential Pressure Stabilization
Fixed pressure differential prevents frequent switching and unnecessary equipment startup/shutdown.
- Reset Mode
Standard automatic reset; contacts recover initial state once pressure returns to normal range.
Application Scenarios of QPL25.050B
Applicable Sites
- Low pressure monitoring and protection for gas boilers and water heaters
- Supply pressure interlock control of oil and gas industrial burners
- Pressure stabilization detection for commercial kitchen stoves and hot air furnaces
- Medium-low pressure monitoring of natural gas and liquefied gas pipelines
- Safety protection for furnace and drying equipment gas supply
- Start-stop interlock for clean combustible gas such as biogas and coal gas
Forbidden Sites
- Gas pipelines with pressure higher than 690mbar
- Gas medium containing corrosion, dust and oil contaminants
- Ambient temperature below -20℃ or above 60℃
- Sites with fierce vibration and uncovered outdoor installation