Siemens QPL25.050B Gas Pressure Switch

Siemens QPL25.050B is a high-performance gas pressure switch. Designed for medium and low pressure monitoring ranging from 5-50 mbar, it features IP54 protection grade and a mechanical service life of 100,000 cicli. It is widely used for safety protection of combustion systems. Check model parameters, pressure range and mounting interface during procurement to ensure full ...

  • Dettagli del prodotto

Siemens QPL25.050B is a high-performance gas pressure switch. Designed for medium and low pressure monitoring ranging from 5-50 mbar, it features IP54 protection grade and a mechanical service life of 100,000 cicli. It is widely used for safety protection of combustion systems. Check model parameters, pressure range and mounting interface during procurement to ensure full compatibility with system requirements.

  1. Definizione del codice modello
Segmento di codiceSensoDescrizione
QPLCodice serie prodottoBasic series of Siemens gas pressure switches for gas and air pressure monitoring
25Struttura & parametri nominaliSerie 25, rated current 6A AC, tensione nominale 250 V CA/CC, Protezione IP54
50Pressure adjustment rangeGamma regolabile: 5-50 mbar (0.5-5.0 kPa)
BVersion markTipo standard, automatic reset, SPDT contact configuration
  1. Parametri delle specifiche principali
CategoriaSpecificheOsservazioni
Parametri di base
Tipo di prodottoMechanical gas pressure switchSafety monitoring for combustion systems
Ordine n.1117087Official Siemens part number
Adjustment Range5-50 mbar (0.5-5.0 kPa)Adjustable set point
Max Working Pressure690 mbar (69 kPa)Upper limit of continuous operating pressure
Switch Differentialca. 5-10 mbarPressure difference between switch-on and switch-off
Parametri Elettrici
Tensione nominaleAC 250V / CC 250 VTensione operativa massima
Corrente nominaleAC 6A / DC 1ACarico resistivo
Tipo di contattoSPDT1 normalmente aperto + 1 normalmente chiuso
Collegamento elettricoTerminal box compliant with DIN EN 175 301-803Classe 3 protezione dell'isolamento
Meccanico & Parametri Ambientali
Pressure PortG1/4 internal thread (ISO228)Center position at bottom casing
Measuring PortØ9mm, 10mm length with locking screwFor pressure calibration
Temperatura ambiente-20°C~+60°CIntervallo di temperatura operativa
Temperatura media-40°C~+60°CApplicable gas temperature
Grado di protezioneIP54Antipolvere e impermeabile
Mechanical Lifespan100,000 cicliSwitch actuation times
Applicable MediaClasse 1/2/3 gases & non-corrosive gasNatural gas, liquefied petroleum gas, ecc.
  1. Full QPL25 Series Model List
ModelloIntervallo di pressioneMax Working PressureOsservazioni
QPL25.003B0.3-3 mbar690 mbarLow pressure monitoring
QPL25.010B1-10 mbar690 mbarUltra-low pressure application
QPL25.050B5-50 mbar690 mbarStandard medium-low pressure
QPL25.150B15-150 mbar690 mbarMedium pressure monitoring
QPL25.500B100-500 mbar720 mbarHigh pressure monitoring
  1. Cross-brand Replacement Comparison
MarcaModelloIntervallo di pressionePrincipali differenzeReplacement Suggestion
SiemensQPL25.050B5-50 mbarOriginal authentic product, elevata stabilitàPriority choice
HoneywellC6097A5-50 mbarprezzo più basso, similar response speedSostituzione diretta
DanfossKPI 365-50 mbarDiversa struttura meccanica, high adjustment precisionVerify mounting dimensions
DungsLGW50A25-50 mbarGerman brand, qualità affidabilePienamente compatibile
BalturPAMPA5-50 mbarBurner dedicated, convenienteSuitable for Baltur combustion systems
  1. Risoluzione dei problemi comuni & Manutenzione

5.1 Difetti comuni & Cause

Fenomeno di guastoPossibili causePassaggi per la risoluzione dei problemi
No switch action under normal pressureImproper setpoint; oxidized/damaged contacts; aging/damaged diaphragm; cablaggio allentatoRecalibrate setpoint; test contact continuity; inspect diaphragm; fasten terminals
No switching under abnormal pressureExcessive switch differential; mechanical stuck; spring fatigueAdjust differential; clean moving parts; replace spring assembly
Frequent contact ablationSovraccarico; unstable voltage; mismatched contact materialControllare la corrente di carico; install surge suppressor; replace contact assembly
Inaccurate pressure readingBlocked measuring port; deformed diaphragm; calibration errorClean port; replace diaphragm; recalibrate with standard pressure source

5.2 Linee guida per la manutenzione

  1. Safety Precaution

Cut off gas supply and release pressure

Disconnect power supply

Cool down equipment to room temperature

  1. Calibration Procedure

① Remove protective cover and locate adjusting screw

② Connect standard pressure source and set target value

③ Clockwise rotation increases set pressure, counter-clockwise decreases

④ Test switching action and confirm accurate trigger point

⑤ Reinstall cover and ensure tight sealing

  1. Component Replacement

Diaphragm: Dismount with special tools, pay attention to gasket installation direction

Contatto: Replace whole switch module instead of single contact

Primavera: Use identical specification spare part to guarantee precision

  1. Ambiente applicativo & Casi di settore

6.1 Scenari applicabili

✅ Recommended Applications

Safety monitoring for industrial & civil gas burners

Pressure protection system of gas boilers

Pressure control of natural gas pipelines

Gas supply system of industrial furnaces

Pressure monitoring for biogas power generation equipment

❌ Inadmissible Applications

High-pressure gas system over 690 mbar

Corrosive gas atmosphere

Medium temperature exceeding 60°C or below -20°C

Severe vibration and outdoor exposed installation without protection

6.2 Typical Industry Applications

IndustriaApplicazioneFunzione
HVACCommercial gas boilerMonitor gas pressure to ensure combustion efficiency and safety
Food ProcessingBaking furnace gas systemAvoid incomplete combustion caused by low pressure
Industria energeticaBiogas power stationStabilize biogas pressure and protect generating units
ManufacturingCeramic kilnPrecise temperature control via gas pressure regulation
Commercial KitchenLarge cooking equipmentSafety interlock to prevent gas leakage accidents
  1. Suggerimenti per la selezione & Avoidable Risks

Mnemonico di selezione

QPL series for gas service, 25 stands for 6A rating

Last three digits define pressure range, B means standard auto-reset

050 model fits 5-50 mbar, G1/4 thread for installation

IP54 solid protection, match gas medium properly

Note chiave

  1. Pressure Matching

Keep actual working pressure within 20%-80% of adjustment range to maintain accuracy.

  1. Requisiti di installazione

Mount vertically with diaphragm downward to avoid condensed water accumulation.

Install filter at pressure port to prevent internal impurity damage.

Secure wiring firmly to avoid false triggering.

  1. Safety Regulations

Interlock with gas leakage alarm device.

Conduct regular inspection and calibration every 6 mesi.

Perform pressure and leakage test after maintenance.

  1. Purchase Notice

Choose genuine Siemens products; counterfeit items have unstable quality.

Keep original package and certificate for after-sales service.

Working Principle of QPL25.050B

Core principle: Air pressure deforms diaphragm, mechanical linkage drives contact on-off to realize overpressure interlock protection

  1. Pressure Sensing

Gas flows into inner chamber through G1/4 port and acts on rubber diaphragm, driving axial displacement with pressure variation.

  1. Mechanical Force Balance

Diaphragm thrust counterbalances preset spring tension. Rotate adjusting screw to change spring preload and set trigger pressure threshold.

  1. Linkage Actuation

When pressure rises to set value, diaphragm overcomes spring resistance and pushes rod to drive lever mechanism. Spring rebounds when pressure drops below threshold.

  1. Contact Switching

Lever movement switches SPDT contacts, reverses circuit status and transmits electric signal for burner start-stop and alarm interlock.

  1. Differential Pressure Stabilization

Fixed pressure differential prevents frequent switching and unnecessary equipment startup/shutdown.

  1. Reset Mode

Standard automatic reset; contacts recover initial state once pressure returns to normal range.

Application Scenarios of QPL25.050B

Applicable Sites

  1. Low pressure monitoring and protection for gas boilers and water heaters
  2. Supply pressure interlock control of oil and gas industrial burners
  3. Pressure stabilization detection for commercial kitchen stoves and hot air furnaces
  4. Medium-low pressure monitoring of natural gas and liquefied gas pipelines
  5. Safety protection for furnace and drying equipment gas supply
  6. Start-stop interlock for clean combustible gas such as biogas and coal gas

Forbidden Sites

  1. Gas pipelines with pressure higher than 690mbar
  2. Gas medium containing corrosion, dust and oil contaminants
  3. Ambient temperature below -20℃ or above 60℃
  4. Sites with fierce vibration and uncovered outdoor installation

Prec: