Segmento modelloDescrizione
RTFilled cartridge tubular fuse (national standard code)
28Design serial number
NNew base, differentiated from old-type RT28 base
32Base rated current 32A (fuse link applicable range: 2-32UN)
/20UNMatched fuse link rated current 20A
  1. Main Specification Parameters

2.1 Base (RT28N-32) Parametri

ParametroValore
Tensione nominaleAC 500V
Corrente nominale32UN
Applicable Fuse Link Size10×38mm (cylindrical ceramic fuse link)
Tipo di montaggioMontaggio su guida DIN
Numero di poli1P/2P/3P optional
Indicator DeviceOptional indicator type (codice “X”, neon lamp + resistor assembly)
Classe di protezioneIP20
Applicable StandardCEI 60269-2

2.2 Fuse Link (RT28-32/20A) Parametri

ParametroValore
Corrente nominale20UN
Categoria di utilizzogG (full-range breaking capacity, for power distribution protection)
Tensione nominaleAC 500V
Capacità di interruzione100IL (AC 500V)
Dimensione10×38mm (ceramic material)
Equivalent Industry ModelRO15-20A
  1. Applicazione & Principio di funzionamento

Ambito di applicazione: Used in distribution circuits with AC 45Hz~62Hz, rated voltage up to 500V and rated current up to 32A, serving as overload and short-circuit protection device.

Principio di funzionamento: When circuit overload or short circuit occurs, the melt inside the fuse link heats up and melts, cutting off the circuit to protect electrical equipment from damage.

Note: Not recommended for capacitor cabinets; replace with RT36 series if used for capacitor cabinets.

  1. Elenco degli accessori
Tipo di accessorioDescrizione
Fuse LinkRT28-32/20A (10×38mm ceramic fuse link)
Indicator AssemblyOptional neon lamp + resistor kit (indicator model: RT28N-32X)
Mounting FittingsRail buckle (fits 35mm standard DIN rail)
Fixing ScrewsFor base installation and fastening
  1. Concorrente & Cross-Brand Equivalent
MarcaModello equivalenteDifferenza principale
SchneiderNH00 gG 20A + matching baseBreaking capacity up to 120kA, prezzo più alto
ABBOT 20 gG 10×38 + baseSame dimension, 100potere di interruzione kA, conveniente
DeliziosoRT28N-32/20ASame parameters as Chint, slightly lower price, fully interchangeable
Siemens3NE1 820-0 + base100potere di interruzione kA, con indicatore, prezzo più alto
  1. Punti chiave della selezione & Soluzioni alternative

Punti chiave della selezione

  1. Corrispondenza attuale: Fuse link rated current shall be 1.1~1.5 times the rated current of protected equipment.
  2. Capacità di interruzione: Ensure fuse breaking capacity ≥ circuit prospective short-circuit current.
  3. Dimension Matching: RT28N-32 base only fits 10×38mm fuse links; mixed use of other sizes is prohibited.
  4. Selezione del palo: Select 1P (monofase), 2P (single-phase double-pole) o 3P (trifase) according to circuit phase.
  5. Indicator Requirement: Choose indicator type (RT28N-32X) if blown fuse indication is needed.

Soluzioni alternative

  1. Upgraded Same Series: RT28N-63X (applicable for fuse links below 63A, CA 690 V)
  2. Fast Fuse: RT36 series (for special occasions such as capacitor cabinets)
  3. Circuit Breaker Replacement: DZ47 series miniature circuit breaker (reusable, with overload and short-circuit protection)
  4. Installazione & Linee guida per la manutenzione
  5. Verify matching model of base and fuse link before installation; check fuse link for damage.
  6. Fasten the rail buckle during DIN rail mounting to avoid poor contact caused by looseness.
  7. Tighten terminals during wiring; conductor cross-section shall meet current requirement (2.5-4mm² copper wire recommended for 20A).
  8. Inspect fuse status regularly; lit indicator on indicator-type model means the fuse link is blown and shall be replaced timely.
  9. Cut off power supply and use insulated tools when replacing fuse link to avoid electric shock risk.

Chint Cylindrical Fuse Base + Fuse Link Complete Model List

  1. Model Naming Rule

Base Model: RT28N-□(X) □P

RT: Filled cartridge tubular fuse

28: Design serial number

N: New type base

: Base rated current (32/63)

X: With blown fuse indicator (opzionale)

□P: Numero del polo (1P/2P/3P)

Fuse Link Model: RT28-□/△A (industry equivalent: RO15 series)

: Matched base rated current (32/63)

: Fuse link rated current (2-32A/2-63A)

gG: Full-range breaking capacity, general purpose

  1. Complete Base Model List
Base ModelCorrente nominaleNumero di poliWith IndicatorApplicable Fuse LinkTipo di montaggioClasse di protezione
RT28N-32 1P32UN1PNOSerie RT28-32 (10×38mm)Guida DINIP20
RT28N-32 2P32UN2PNOSerie RT28-32 (10×38mm)Guida DINIP20
RT28N-32 3P32UN3PNOSerie RT28-32 (10×38mm)Guida DINIP20
RT28N-32X 1P32UN1PSÌ (neon lamp+resistor)Serie RT28-32 (10×38mm)Guida DINIP20
RT28N-32X 2P32UN2PSÌ (neon lamp+resistor)Serie RT28-32 (10×38mm)Guida DINIP20
RT28N-32X 3P32UN3PSÌ (neon lamp+resistor)Serie RT28-32 (10×38mm)Guida DINIP20
RT28N-63 1P63UN1PNORT28-63 series (14×51mm)Guida DINIP20
RT28N-63 2P63UN2PNORT28-63 series (14×51mm)Guida DINIP20
RT28N-63 3P63UN3PNORT28-63 series (14×51mm)Guida DINIP20
RT28N-63X 1P63UN1PSÌ (neon lamp+resistor)RT28-63 series (14×51mm)Guida DINIP20
RT28N-63X 2P63UN2PSÌ (neon lamp+resistor)RT28-63 series (14×51mm)Guida DINIP20
RT28N-63X 3P63UN3PSÌ (neon lamp+resistor)RT28-63 series (14×51mm)Guida DINIP20
  1. Complete Fuse Link Model List (for RT28N Base)

3.1 RT28-32 Series Fuse Link (for 32A Base, 10×38mm Ceramic)

Fuse Link ModelCorrente nominaleModello equivalenteCapacità di interruzioneTensione nominale
RT28-32/2A2UNRO15-2A100IL(AC 500V)AC 500V
RT28-32/4A4UNRO15-4A100IL(AC 500V)AC 500V
RT28-32/6A6UNRO15-6A100IL(AC 500V)AC 500V
RT28-32/10A10UNRO15-10A100IL(AC 500V)AC 500V
RT28-32/16A16UNRO15-16A100IL(AC 500V)AC 500V
RT28-32/20A20UNRO15-20A100IL(AC 500V)AC 500V
RT28-32/25A25UNRO15-25A100IL(AC 500V)AC 500V
RT28-32/32A32UNRO15-32A100IL(AC 500V)AC 500V

3.2 RT28-63 Series Fuse Link (for 63A Base, 14×51mm Ceramic)

Fuse Link ModelCorrente nominaleModello equivalenteCapacità di interruzioneTensione nominale
RT28-63/2A2UNRO16-2A100IL(AC 500V)AC 500V
RT28-63/4A4UNRO16-4A100IL(AC 500V)AC 500V
RT28-63/6A6UNRO16-6A100IL(AC 500V)AC 500V
RT28-63/10A10UNRO16-10A100IL(AC 500V)AC 500V
RT28-63/16A16UNRO16-16A100IL(AC 500V)AC 500V
RT28-63/20A20UNRO16-20A100IL(AC 500V)AC 500V
RT28-63/25A25UNRO16-25A100IL(AC 500V)AC 500V
RT28-63/32A32UNRO16-32A100IL(AC 500V)AC 500V
RT28-63/40A40UNRO16-40A100IL(AC 500V)AC 500V
RT28-63/50A50UNRO16-50A100IL(AC 500V)AC 500V
RT28-63/63A63UNRO16-63A100IL(AC 500V)AC 500V
  1. Typical Combination Model Examples
Complete Combination ModelBase ModelFuse Link ModelScenario applicativo
RT28N-32 1P + RT28-32/16ART28N-32 1PRT28-32/16ASingle-phase 220V circuit, 16A load protection
RT28N-32X 2P + RT28-32/20ART28N-32X 2PRT28-32/20ASingle-phase 2P circuit, 20A load protection with blown indicator
RT28N-32 3P + RT28-32/32ART28N-32 3PRT28-32/32AThree-phase 380V circuit, 32A load protection
RT28N-63X 3P + RT28-63/50ART28N-63X 3PRT28-63/50AThree-phase 380V circuit, 50A load protection with blown indicator
  1. Selezione & Note applicative
  2. Dimension Matching: Serie RT28-32 (10×38mm) only fits RT28N-32 base; RT28-63 series (14×51mm) only fits RT28N-63 base.
  3. Selezione del palo: Choose 1P/2P for single-phase circuits, 3P for three-phase circuits.
  4. Indicator Requirement: Select X-type with indicator if fuse blown alert is required.
  5. Current Selection: Fuse rated current shall be 1.1~1.5 times the rated current of protected equipment.
  6. Special Application: Not suitable for capacitor cabinets; adopt RT36 series as alternative.