NXC-185-380V (注文番号: 710010100000343) Segment Meaning Description NXC Product Series CHINT Kunlun series AC contactor, upgraded compact structure replacing traditional CJX2 series 185 Rated Current Rated operational current of main contact: 185あ (AC-3, 400V) 380V Coil Voltage Rated control coil voltage: AC380V, standard frequency 50Hz Supplementary Specifications: 3-ポール (3P), 3 normally-open main contacts, 2NO+2NC auxiliary ...

  • 製品詳細

NXC-185-380V (注文番号: 710010100000343)

セグメント意味説明
NXC製品シリーズCHINT Kunlun series AC contactor, upgraded compact structure replacing traditional CJX2 series
185定格電流Rated operational current of main contact: 185あ (AC-3, 400V)
380Vコイル電圧Rated control coil voltage: AC380V, standard frequency 50Hz

Supplementary Specifications: 3-ポール (3P), 3 normally-open main contacts, 2NO+2NC補助接点, standard mounting type

  1. コア仕様パラメータ
カテゴリ技術データ備考
Basic Properties
製品タイプElectromagnetic AC Contactor崑崙シリーズ, replacement for CJX2-1850
適用規格ギガバイト/トン 14048.4 / IEC 60947-4-1Compliant with GB 21518 安全規格
定格絶縁電圧1000VUnified standard for specifications above 120A
定格動作電圧220V~690VCompatible with various industrial power supply systems
電気的パラメータ
定格動作電流 (つまり)185あ (AC-3, 400V)Matches motor power around 90kW
Rated Making Capacity10×いえ (AC-3)1850あ, reliable load switching
定格遮断容量8×いえ (AC-3)1480あ, safe fault current interruption
コイルパラメータAC380V, 50Hz, power approx. 170バージニア州Pick-up/holding power ratio about 3:1
補助接点2NO+2NC, rated current 5ASignal transmission for control circuits
機械的パラメータ
極数3P (3 メイン接点なし)標準構成, 4P version optional
取付方法標準35mm DINレール / ネジ取付Fits mainstream control cabinets
ハウジング材質Flame-retardant engineering plasticUL94 V0 flame resistance grade
保護等級IP20Finger-touch safe, indoor cabinet installation only
機械的寿命10,000,000 オペレーション長寿命, low maintenance frequency
電気的寿命1,000,000 オペレーション (AC-3)Suitable for frequent start-stop operation
環境パラメータ
動作温度-30℃~+70℃Wide temperature range for harsh industrial conditions
保管温度-40℃~+85℃Meets storage and transportation requirements
相対湿度5%~95%, 結露しないことAdaptable to humid working environment
高度≤2000mDerating required for higher altitude
  1. Cross-brand Replacement Comparison
ブランドモデルSimilar Features違い
チントNXC-185-380V参考モデル崑崙シリーズ, 費用対効果の高い, preferred domestic replacement
シュナイダーLC1D18500Q7185あ, 3P, 380Vコイルより高い価格, 1NO+1NC auxiliary contacts
ABBA185-30-11185あ, 3P, 380Vコイル1NO+1NC auxiliary contacts, different mounting dimensions
シーメンス3RT2036-1AP00185あ, 3P, 380VコイルHigh price, 速い応答, ideal for precision control
デリシCDM3-185185あ, 3P, 380Vコイル国内代替品, 同様の価格, slightly lower performance

交換ノート:

  1. Confirm identical coil voltage, pole number and auxiliary contact configuration before replacement
  2. Verify mounting hole compatibility among different brands
  3. Check derating curve matching for high altitude and special environments
  4. Matching CHINT NXR thermal overload relay is recommended for optimal protection
  5. 全シリーズモデルリスト (Core NXC Models)
モデル 定格電流 コイル電圧 補助接点 ポール 注文番号.
NXC-06-220V 6あ AC220V 1NO+1NC 3P710010100000001
NXC-12-380V 12あ AC380V 1NO+1NC 3P710010100000002
NXC-18-220V 18あ AC220V 1NO+1NC 3P710010100000003
NXC-25-380V 25あ AC380V 1NO+1NC 3P710010100000004
NXC-32-220V 32あ AC220V 1NO+1NC 3P710010100000005
NXC-40-380V 40あ AC380V 1NO+1NC 3P710010100000006
NXC-50-220V 50あ AC220V 1NO+1NC 3P710010100000007
NXC-65-380V 65あ AC380V 1NO+1NC 3P710010100000008
NXC-80-220V 80あ AC220V 2NO+2NC 3P710010100000009
NXC-100-380V 100あ AC380V 2NO+2NC 3P710010100000305
NXC-120-220V 120あ AC220V 2NO+2NC 3P710010100000306
NXC-150-380V 150あ AC380V 2NO+2NC 3P710010100000307
NXC-185-380V 185あ AC380V 2NO+2NC 3P710010100000343
NXC-225-380V 225あ AC380V 2NO+2NC 3P710010100000344
NXC-265-380V 265あ AC380V 2NO+2NC 3P710010100000345

Model Extension Rules:

Suffix M: リバーシブルコンタクタ (例えば. NXC-25M-220V)

Suffix 4P: 4-極接触器 (例えば. NXC-65-4P-380V)

Suffix Z: DCコイル (例えば. NXC-18-24Z)

Auxiliary contact expansion: Max 6NO+6NC with F4-XX auxiliary contact block

  1. 一般的な障害 & トラブルシューティング
故障現象考えられる原因ソリューション
コンタクタが引き込まれない1. Abnormal coil voltage1. Verify stable 380V power supply
2. Open control circuit2. Check wiring and fuse
3. 焼けたコイル3. Test coil resistance (normal ~800Ω), replace damaged coil
4. Mechanical jam4. Clean iron core and reset spring
引き込み後の異音が大きい1. Oil contamination on core surface1. Clean contact surface of iron core
2. ショートリングの破損2. Replace iron core or short-circuit ring
3. 不足電圧3. Ensure voltage ≥85% rated value
Overheated / burned contacts1. 過大な負荷電流1. Upgrade to higher capacity model
2. Poor contact performance2. Clean contacts and adjust contact pressure
3. 頻繁な切り替え3. Optimize control logic to reduce unnecessary switching
4. Failed arc suppression4. Inspect and maintain arc shield
Malfunction of auxiliary contacts1. 接触酸化1. Polish and clean contacts
2. 接触アブレーション2. Replace auxiliary contact assembly
3. 配線の緩み3. Fasten terminal connections
Overheating and burnt coil1. 過電圧1. Keep voltage within rated range
2. Excessive operation frequency2. Reduce switching frequency or adopt AC-4 type contactor
3. 周囲温度が高い3. Improve ventilation condition
4. Stuck iron core4. Ensure flexible mechanical movement
  1. 航空貨物のコンプライアンス & 認証
  2. 認証

CE認証, compliant with EU Machinery Directive

cULus certification complying with North American safety standards

CCC compulsory certification of China

RoHS environmental compliance

  1. Air Transport Regulations

リチウム電池やスーパーキャパシタは内蔵していません, classified as ordinary industrial electrical equipment

非危険物, conforms to IATA DGR Class 9 要件

Standard industrial packaging, 最大 20 units per carton to avoid collision damage

Recommended marks: FRAGILE, ELECTRICAL EQUIPMENT, KEEP DRY

  1. アプリケーション環境 & Adaptation

該当するシナリオ

産業用モーター制御: 始める, stop and reverse control of three-phase asynchronous motors below 90kW

ファン & Water Pump System: 空調設備, industrial circulating water and sewage aeration equipment control

コンプレッサー制御: Heavy-duty air and refrigeration compressors for AC-3 working condition

自動生産ライン: Core component for sequence control and interlock protection

Building Electrical System: Central air conditioning, fire water pump and elevator room equipment control

Mining Machinery: Remote control and protection for belt conveyors and crushers

Metallurgical Equipment: Electrical control system for small rolling mills and furnace auxiliary units

不適切なシナリオ

DC circuit control (Select dedicated NXC-Z series DC contactors)

High-frequency operation over 1200 cycles per hour (AC-4 contactor or solid state relay recommended)

Use above 2000m altitude without power derating

Severe vibration environment over 5g without damping measures

Corrosive gas environment without anti-corrosion protection

  1. Application Cases

場合 1: Central Air Conditioning Control of Large Shopping Mall

応用: Control of 3 sets 90kW water chillers and 4 sets 75kW cooling tower fans

Challenges: 20-30 daily start-stop cycles, high reliability and energy saving requirement

解決: NXC-185-380V + NXR-185 thermal overload relay + intelligent PLC control system

Result: Trouble-free operation for 2 年, 30% energy saving with frequency conversion, 50% maintenance cost reduction

場合 2: Conveyor System for Auto Parts Production Line

応用: 12 belt conveyor lines with 75kW driving motor each, sequential start-stop and interlock protection

Challenges: Multi-motor synchronous control, frequent forward/reverse rotation, oily environment

解決: NXC-185-380V for main drive + NXC-65-380V for auxiliary drive + safety relay

Result: Precise synchronous operation, IP20 protection against oil contamination, までの機械的寿命 8 百万サイクル

  1. 選定ガイドライン

Quick Rules

定格電流: NXC-X ranging 6~630A, matching motor power about X/2 kW

Standard coil voltage: 220V / 380V; optional 110V / 24V / 48V

補助接点: 1NO+1NC for ≤80A; 2NO+2NC for ≥100A

取り付け: Universal 35mm DIN rail for mainstream cabinets

保護クラス: IP20, indoor cabinet use only, outdoor exposed installation prohibited

Specific Application Scenarios of NXC185-380V

  1. モーター制御

始める, stop and reverse control of three-phase asynchronous motors below 90kW

Continuous operation control of constant-load equipment including fans, ポンプとコンプレッサー

Motor control with operation frequency ≤1200 cycles per hour

  1. Industrial Automation System

Sequence control and interlock protection of production line facilities

Peripheral equipment control of robot workstations

Stacker and conveyor control in automated warehouses

  1. 工事 & インフラストラクチャー

Water chiller and cooling tower control for commercial central air conditioning

Fire water pump and exhaust fan control of high-rise buildings

Ventilation system control of underground parking lots

  1. エネルギー & 環境保護

Aeration equipment and sludge pump control in sewage treatment plants

Switch control of small photovoltaic inverters and energy storage systems

Control system of waste disposal equipment

  1. マイニング & 冶金

Belt conveyor and crusher control in mines

Auxiliary equipment control of small metallurgical furnaces

Electrical control system of mineral processing facilities

Restricted Application

DC circuit application

Operation frequency exceeding 1200 cycles per hour

Underrated use at altitude over 2000m

Heavy vibration environment without damping measures

Corrosive gas environment without protective treatment