チントサージプロテクター NXU-ⅡG-40kA/275V - コンタクタ,サーキットブレーカー,ソーラーインバーター,電気メーター,太陽電池

微信: +86-13184948252 ワッツアップ: 0086-13811255435 電子メール: kent@bestcontactor.com

について 接触 |

チントサージプロテクター NXU-ⅡG-40kA/275V - コンタクタ,サーキットブレーカー,ソーラーインバーター,電気メーター,太陽電池

電気メーター/電気/

チントサージプロテクター NXU-ⅡG-40kA/275V

Chint Surge Protector NXU-40/275 (つまり, model NXU-ⅡG-40kA/275V) is a surge protection device specially designed for low-voltage distribution systems, suitable for household, commercial and industrial scenarios. 以下はその主要な情報と適用ガイドラインです。: Technical Parameters and Performance Core Indicators Maximum Continuous Operating Voltage (Uc): 275Vと, suitable for 220V/230V standard power grids. Maximum Discharge Current ...

  • 製品詳細

Chint Surge Protector NXU-40/275 (つまり, model NXU-ⅡG-40kA/275V) is a surge protection device specially designed for low-voltage distribution systems, suitable for household, commercial and industrial scenarios. 以下はその主要な情報と適用ガイドラインです。:

  1. Technical Parameters and Performance
  2. Core Indicators

Maximum Continuous Operating Voltage (Uc): 275Vと, suitable for 220V/230V standard power grids.

Maximum Discharge Current (Imax): 40の (8/20μs waveform), nominal discharge current (で) is 20kA, capable of withstanding multiple surge impacts.

Voltage Protection Level (Up): ≤1.5kV, which can limit the instantaneous overvoltage within the safe range of equipment, significantly lower than the tolerance threshold of most household appliances and electronic devices (usually ≥2kV).

Pole Number and Installation: Supports 2P (単相) configuration, adopts 35mm guide rail installation, and the modular design allows plug-in replacement of protection modules without rewiring.

  1. Safety Certifications

– IEC/ENに準拠 61643-11 および GB/T 18802.11 標準, and has passed CQC, CE, and CB certifications, suitable for most markets around the world.

Built-in thermal trip and short-circuit protection mechanisms, which automatically disconnect the circuit in case of failure to avoid fire risks.

  1. アプリケーション シナリオとインストールに関する推奨事項
  2. 適用範囲

Household Protection: Installed at the secondary distribution position of the distribution box to protect household appliances such as air conditioners, 冷蔵庫, and TVs, especially suitable for areas with frequent thunderstorms.

Commercial and Industrial: Used in office and shopping mall distribution systems, or at the front end of industrial equipment (such as PLC, frequency converters) to resist lightning strikes and operating overvoltages generated by equipment start-up and shutdown.

Photovoltaic Systems: Can protect inverters and components, reducing damage to new energy equipment caused by lightning strikes.

  1. 設置ポイント

Location Selection: Close to the power supply incoming end of the protected equipment, with a wiring length of ≤1.5 meters to reduce the impact of line inductance on protection effects.

接地要件: The grounding wire diameter is ≥4mm², length ≤5 meters, and grounding resistance <4Ω to ensure that surge energy is quickly discharged into the ground.

Cooperating with Circuit Breakers: A 10-16A circuit breaker needs to be connected in series at the front end to prevent fire caused by SPD short circuits.

Ⅲ. メンテナンスと交換

  1. 状態監視

The surface of the module is equipped with a degradation indicator window, which is green when normal and pops up a red warning after failure, requiring immediate replacement.

It is recommended to check the indicator lights and wiring terminals quarterly, and focus on testing the grounding system before the thunderstorm season.

  1. Lifespan and Replacement Cycle

The service life is about 5-8 years under normal use. If it frequently encounters high-current surges (such as direct lightning strikes), it needs to be evaluated for replacement in advance.

– 交換時, only need to pull out the old module and insert a new module of the same specification, without professional tools.

  1. Purchase and Price Reference
  2. チャネルと価格

国際市場: Purchases can be made through Whatsapp: 0086-13811255435

  1. Description of Alternative Models

The NXU-ⅡG series is an upgraded version of the previous NU6-II, with significant optimizations in response speed (<25ns), impact resistance times (≥20 times In), and heat dissipation design.

  1. 予防
  2. 環境適応力

The operating temperature range is -40℃~+70℃, and humidity ≤95% (結露なし), suitable for harsh environments such as high temperature and high humidity.

Avoid installation in areas with strong electromagnetic interference, and keep away from inductive loads (such as large motors) to reduce false triggers.

  1. 選択の推奨事項

If the grid voltage fluctuates greatly (such as in remote areas), the Uc=320V model can be selected; for industrial scenarios, it is recommended to match the NXU-ⅡG-F series with remote signaling contacts to realize remote status monitoring.

  1. Typical Troubleshooting
故障現象考えられる原因ソリューション
Indicator light turns redModule degradation or short circuitReplace the module after power off and check the front circuit breaker
Frequent misoperationPoor grounding or electromagnetic interferenceRe-lay the grounding wire and add shielding measures
Equipment still damaged after protectionExcessively high voltage protection levelUpgrade to a model with Up≤1.2kV (such as NXU-ⅡG-65)

Through reasonable selection and standardized installation, NXU-40/275 can effectively improve the stability of the electrical system and reduce the risk of equipment damage caused by surges. It is recommended to formulate a hierarchical protection scheme (such as primary + secondary + tertiary combination) according to local power grid characteristics and equipment requirements to achieve comprehensive protection.

故障現象考えられる原因ソリューション
Indicator light turns redModule degradation or short circuitReplace the module after power off and check the front circuit breaker
Frequent misoperationPoor grounding or electromagnetic interferenceRe-lay the grounding wire and add shielding measures
Equipment still damaged after protectionExcessively high voltage protection levelUpgrade to a model with Up≤1.2kV (such as NXU-ⅡG-65)