Mitsubishi NZ2GF2BN-60AD4 Remote Module

Complete List of Mitsubishi NZ2GF2BN Series (Screw Terminal Block CC-Link IE Field Remote Analog Main Units) 注記: NZ2GF2BN = NZ2GF2B + upgraded N revision (pin-compatible direct replacement for legacy NZ2GF2B-xxxx). Equipped with dual RJ45 ports and supports one NZ2EX2B expansion module. Only NZ2GF2BN main units (アナログ) are listed below. Digital I/O modules without the suffix ...

  • 製品詳細

Complete List of 三菱 NZ2GF2BN Series (Screw Terminal Block CC-Link IE Field Remote Analog Main Units)

注記:

NZ2GF2BN = NZ2GF2B + upgraded N revision (pin-compatible direct replacement for legacy NZ2GF2B-xxxx). Equipped with dual RJ45 ports and supports one NZ2EX2B expansion module.

Only NZ2GF2BN main units (アナログ) are listed below. Digital I/O modules without the suffix “N” do not belong to this analog BN series. Matching expansion modules are NZ2EX2B-xxxx (no network port; can only be mounted behind NZ2GF2BN main units).

NZ2GF2BN-60AD4

NZ2GF: CC-Link IE Field remote module series

2B: Block-type remote I/O main unit

N: Upgraded new generation model (replaces NZ2GF2B-60AD4; pin-compatible for direct replacement)

60広告: A/D analog input module

4: 4-チャンネルアナログ入力

製品のポジショニング

CC-Link IE Fieldリモートデバイス局, 4-チャンネルアナログ入力モジュール, DINレール取付, equipped with dual Ethernet ports for bus daisy-chain wiring.

  1. コア仕様
アイテムパラメータ
チャンネル数4CH analog input
サポートされる信号タイプ電圧: -10~10V, 0~5V, 1~5V
現在: 0~20mA, 4~20mA, -20~20mA
Input Impedance電圧: 1MΩ; 現在: 250おお
A/D Resolution16-bit signed, conversion range: -16000 ~ +16000
Selectable Conversion Speed100μs/ch / 400μs/ch / 1ms/ch
絶縁方法Isolation between analog channels and network power supply; no isolation between channels
External Power SupplyDC24V (20.4~28.8V), current consumption 210mA
通信インターフェース2×RJ45 (100M CC-Link IE Field, daisy-chain wiring)
Occupied Station Count1 駅 (remote device station)
拡張容量サポート 1 external expansion module NZ2EX2B-60AD4 (maximum extended to 8 チャンネル)
周囲温度手術: 0~55℃; ストレージ: -25~75℃, 結露なし
重さ約. 0.30kg
取り付けDIN35 rail
  1. 主な特長
  2. Direct Compatibility for NZ2GF2B-60AD4 Replacement

Fully compatible terminal layout; existing wiring remains unchanged for direct upgrade. The N-version optimizes noise suppression and synchronous timing performance.

  1. Network Synchronization Function

Supports CC-Link IE Field synchronous communication. Synchronized sampling with motion modules is available, ideal for high-speed acquisition and tension control applications.

  1. Trigger Conversion Function

Hardware-triggered sampling is supported for dynamic acquisition of high-speed pressure and flow signals.

  1. Built-in Diagnostics

Open-circuit detection (4~20mA loop), over-range alarm, module fault and communication abnormality monitoring; upper/lower limit supervision per channel.

  1. Digital Filtering

Average processing and moving average filter parameters can be configured via software to suppress on-site interference.

  1. 配線ガイドライン (18-point screw terminal)

V+ / V-: Voltage signal input

I+ / I-: Current signal input

FG: Shield ground (must connect to cabinet protective ground to reduce interference)

24V+/24V-: External operating power supply for module

⚠️ Prohibitions:

  1. Voltage and current signals cannot be connected to the same channel simultaneously;
  2. Shielded twisted-pair cables are preferred for 4~20mA sensors;
  3. No isolation between channels, creating common-ground risks for multi-signal systems. Single-point grounding on the sensor side is recommended for multiple transmitters.
  4. Software Configuration Guidelines

Available Master Station Modules: QJ71GF11-T2 / LJ71GF11-T2 / RJ71GF11-T2 (iQ-Rシリーズ)

プログラミングソフトウェア: GXワークス2 / GXワークス3

Configuration Steps:

  1. Register remote device stations and set station numbers in network parameters;
  2. Initialize buffer registers of the module: configure range, filtering and open-circuit detection enable for each channel;
  3. Read converted values of 4 A/D channels and channel status alarm bits via cyclic RX area.
  4. Cross-reference of Alternative Models
  5. Direct Drop-in Replacement: NZ2GF2B-60AD4 (legacy model, gradually phased out; BN upgraded version recommended)
  6. Matching Expansion Module: NZ2EX2B-60AD4 (can only be mounted behind this main unit for expansion; cannot access network independently)
  7. New-generation CC-Link IE TSN Platform: NZ2GN2B-60AD4 (protocol upgraded; cannot be mixed into CC-Link IE Field network)
  8. 典型的なアプリケーションシナリオ

Remote pressure/temperature acquisition for packaging machinery and injection molding machines

Fluid control: acquisition of flow rate, liquid level and regulating valve feedback signals

Distributed sensor acquisition on production lines to reduce cabinet wiring

High-speed analog signal sampling for test benches and inspection equipment

  1. Troubleshooting Table
現象考えられる原因解決
RUN LED blinkingAbnormal DC24V external power supplyMeasure terminal voltage and verify power capacity
ERR LED steady redIncorrect network parameters / station number conflictCheck network configuration in GX Works and terminal resistance
Fixed value on a single channelSensor open circuit, 端子の緩み, mismatched range settingEnable open-circuit detection and inspect loop wiring
Severe signal fluctuation接地不良, disabled filtering, unshielded cablesConnect FG terminal, activate software filtering and adopt shielded cables

NZ2GF2BN Main Units (Independent Network Access)

  1. NZ2GF2BN-60AD4

4-チャンネルアナログ入力 (電圧/電流: ±10V, 0~5V, 1~5V, 0~20mA, 4~20mA, ±20mA)

  1. NZ2GF2BN-60DA4

4-チャンネルアナログ出力 (電圧/電流)

  1. NZ2GF2BN-60TCRT4

4-channel RTD temperature input (Pt100/Pt1000 platinum resistance, 等)

  1. NZ2GF2BN-60TCTT4

4-channel thermocouple input (K, J, T, S, R, B, E, N types, 等)

  1. NZ2GF2BN-60MD4

Multi-function hybrid module: 4-channel universal input (電圧/電流 + 熱電対/測温抵抗体, configurable via software)

  1. Supporting Expansion Modules NZ2EX2B Series (No Network Port, Cannot Access Network Independently, Only for NZ2GF2BN Main Units)

A single NZ2GF2BN main unit supports maximum one expansion module

  1. NZ2EX2B-60AD4 4CH analog input expansion
  2. NZ2EX2B-60DA4 4CH analog output expansion
  3. NZ2EX2B-60TCRT4 4CH RTD expansion
  4. NZ2EX2B-60TCTT4 4CH thermocouple expansion
  5. NZ2EX2B-60MD4 4CH multi-function temperature/analog expansion

NZ2GF2BN-60AD4

NZ2GF2B1-32D

NZ2GF2B2-16R

  1. Model Naming Comparison for Revision Identification

NZ2GF2B-60AD4: Original legacy model

NZ2GF2BN-60AD4: Upgraded new generation model (model in use)

NZ2GN2B-60AD4: New-generation CC-Link IE TSN (異なるプロトコル; cannot mix with CC-Link IE Field network)

  1. Critical Distinction Reminders

Common confusion points:

✅ NZ2GF2BN series contains only the above 5 analog main units

❌ Digital modules such as NZ2GF2B1-16D / NZ2GF2B1-16T carry no suffix “N” and are not part of NZ2GF2BN series;

❌ NZ2GF2S spring terminal series and NZ2GFCE e-CON connector series belong to separate product lines.

  1. Channel Expansion Combinations

NZ2GF2BN-60AD4 + NZ2EX2B-60AD4 → 8CH AI

NZ2GF2BN-60TCRT4 + NZ2EX2B-60TCTT4 → 4 測温抵抗体 + 4 thermocouple channels

NZ2GF2BN-60AD4 + NZ2EX2B-60DA4 → 4AI + 4へ

Application Scenarios Summary – Mitsubishi NZ2GF2BN-60AD4

Module Feature Recap: CC-Link IE Field remote 4-channel analog input, supports voltage/current signals (4~20mA dominant), expandable to 8AI, network synchronous sampling, open-circuit diagnostics, distributed remote acquisition. Suitable for conditions with widely separated equipment, long-distance signal collection and difficulties in centralized cabinet wiring.

Applicable Bus: CC-Link IEフィールド; Matching Master Station: RJ71GF11-T2 / LJ71GF11-T2 / QJ71GF11-T2

  1. Packaging Automation Industry
  2. Vertical Form-Fill-Seal Machines, Horizontal Flow Wrappers

Collect 4~20mA signals from film tension sensors, level transmitters and pressure transmitters. Remote mounting on machine bodies reduces wiring to main control cabinets.

  1. 充填装置 (飲料, Daily Chemical, Sauce)

Liquid level transmitters, flow sensors and filling pressure feedback signals. Open-circuit detection enables early warning of sensor faults.

  1. Cartoning & Palletizing Lines

Distributed collection of pressure and weighing analog signals across production lines with multiple remote modules networked together.

  1. 射出成形 & Rubber-Plastic Machinery
  2. Remote acquisition for auxiliary equipment of injection molding machines: temperature/pressure of mold temperature controllers, barrel oil pressure, hydraulic pressure sensors;
  3. Extrusion production lines: melt pressure transmitters and vacuum pressure signal acquisition.

アドバンテージ: Modules installed close to auxiliary machines. Long analog cables are replaced by industrial Ethernet cables to minimize analog signal interference.

  1. Fluid Control, 水処理 & Environmental Protection Equipment
  2. Integrated Small Sewage Treatment Units, Water Purification Systems

Collect 4~20mA signals from pH transmitters, turbidity meters, level and flow sensors. Suitable for remote distributed I/O deployment on outdoor standalone cabinets.

  1. Circulating water systems and cooling tower units: プレッシャー, temperature transmitters and differential pressure sensor acquisition.
  2. Exhaust gas treatment equipment (VOC removal, dust removal): differential pressure, wind pressure and flow analog signal collection.
  3. Material Conveying & Automated Warehousing
  4. Belt conveyors and sorting lines: analog signals from belt tension sensors and load cells;
  5. Pressure detection for lifting transfer equipment. Distributed installation along production lines with daisy-chain CC-Link IE Field wiring.
  6. Test Machines & Inspection Equipment (Key Advantage Scenarios)

The module supports high-speed A/D conversion (minimum 100μs/ch) and bus synchronous sampling:

  1. Material tensile testers and compression test machines;
  2. Air tightness test benches and leak detection equipment.

Collect dynamic signals from force and pressure sensors and realize multi-channel synchronous sampling via bus synchronization.

  1. 工作機械 & 金属加工装置
  2. CNC grinding machines and hydraulic machine tools: hydraulic system oil pressure and cooling system pressure;
  3. Stamping equipment: mold pressure monitoring.

⚠️ Note: FG shield grounding and shielded sensor cables are mandatory in high-electromagnetic-interference machine tool environments.

  1. 新エネルギー & Battery Production Lines (中くらい & Small Workstations)
  2. Pressure and vacuum acquisition for cell testing stations;
  3. Temperature and pressure transmitter collection for liquid cooling units.

Suitable for layouts with scattered workstations where each station deploys one NZ2GF2BN-60AD4.

  1. Construction Machinery Test Platforms & Automated Test Benches

Hydraulic test benches and valve group test platforms for multi-channel remote pressure sensor acquisition.

✅ Recommended Application Conditions (選定基準)

  1. Sensors are installed far from the main PLC control cabinet;
  2. Multiple scattered analog signals exist on site, avoiding extensive laying of costly shielded analog cables;
  3. The project adopts CC-Link IE Field bus system;
  4. 4 AI channels required at one location, with potential future expansion to 8 チャンネル (matched with NZ2EX2B-60AD4);
  5. 4~20mA loop open-circuit detection and channel over-range alarms are required;
  6. Synchronized analog sampling among multiple modules (tension control and dynamic pressure monitoring applications).

❌ Not Recommended Application Conditions

  1. Only 1~2 analog signals available; single module configuration leads to low cost-effectiveness (signal isolators or integrated transmitters preferred);
  2. On-site network is CC-Link IE TSN (NZ2GN2B series required; mixing prohibited);
  3. Electrical isolation between channels is required (no inter-channel isolation onboard; external signal isolators needed);
  4. Highly corrosive and high-humidity environments without protective enclosures (protective cabinet mandatory).

Typical Matching Solutions

  1. NZ2GF2BN-60AD4 (4AI main unit) + NZ2EX2B-60AD4 (expansion 4AI) = 8-channel remote acquisition station;
  2. Matched with load cells, pressure transmitters and level transmitters with standard 4~20mA signal output;
  3. Multiple remote modules connected in daisy chain for simplified wiring.