モデルコードの内訳
| 分野 | 意味 |
| NZ2 | Series of CC-Link IE Field fieldbus remote I/O modules |
| GF | CC-Link IE Field (Gigabit Ethernet fieldbus) |
| 2 | Module hardware form factor: block-type remote I/O with dual Ethernet ports for daisy-chain cascading |
| B2 | 端子の種類: ネジ端子, 16 points sharing one common terminal (2-wire wiring) |
| 16 | I/O count: 16 output points |
| R | 出力タイプ: relay contact output (passive dry contacts) |
製品のポジショニング: CC-Link IE Field remote device station, block-type remote I/O with 16-point relay outputs. DIN rail mountable and supports Ethernet daisy-chain cascading.
- Core Electrical Specifications
2.1 Output Load Parameters
出力タイプ: Passive mechanical relay contacts
Rated load per channel: AC240V / DC24V, 2A per point
Total common terminal current: 8A for 16-point common terminal
出力応答時間: 約. 12MS (inherent relay actuation delay)
Common terminal specification: 16 points share one COM terminal (2-wire wiring)
2.2 電源 & 消費電力
External power supply: DC24V (module main power supply)
Overall current draw: 0.19A @ DC24V
2.3 物理的寸法 & 重さ
Outline dimensions: W200mm × H50mm × D68mm
重さ: 0.45kg, fits standard 35mm DIN rail mounting
2.4 Network Features
フィールドバス: CC-Link IE Field (1Gbps Ethernet)
Station occupation: 1 station
Dual RJ45 ports: Support daisy-chain cascading, no switch required
Supported functions: Synchronous communication, fast disconnection recovery, automatic I/O parameter recognition, output hold/clear switching
TSN Compatibility: Toggle switch enables CC-Link IE TSN mode (compatible with iQ-R motion master stations)
2.5 環境評価 & 認証
動作温度: 0 ~ +55°C; 保管温度: -25 ~ +75°C
湿度: 5 ~ 95%RH, 結露しないこと
認証: Full industrial certifications including CE, UL/cUL, RoHS, marine classification society approvals (LR/DNV/ABS), KC, 等.
- ターミナル & 配線説明書
- Network Interface: Dual RJ45 ports (P1 In, P2 Out) for daisy-chaining subsequent remote I/O modules via Ethernet cables
- 電源端子: DC24V and 0V power input
- Address DIP Switch: Rotary knob for setting remote station numbers (0 ~ 63 stations)
- I/O Terminals: 16-channel relay outputs (Y0 ~ Y15) with unified COM common terminal
Wiring Feature: Passive contacts compatible with AC220V solenoid valves, indicator lamps and contactor coils; non-polarized for both AC and DC loads.
- 同じシリーズの比較 (Screw vs Spring Terminals)
| モデル | 端子の種類 | 出力 | Common Terminal |
| NZ2GF2B2-16R | M3 screw terminals | 16-ポイントリレー | 1 COM for 16 ポイント |
| NZ2GF2S2-16R | Spring quick-disconnect terminals | 16-ポイントリレー | 1 COM for 16 ポイント |
The two models deliver identical electrical performance; only terminal structures differ, making them mutually interchangeable.
- Compatible Master Station PLCs
- iQ-R Series: R04/R08/R16/R32 CPUs, RD77GF motion modules (supports synchronous control)
- Qシリーズ: Q03UDVCPU + QJ71GF11-T2 CC-Link IE master station
- Lシリーズ: L06CPU + LJ71GF11-T2
- Motion Controllers: MELIPC, MR-J5 servo CC-Link IE fieldbus systems
- 典型的なアプリケーションシナリオ
- Remote drive of distributed solenoid valves and indicator lamps on production lines (compatible with AC220V loads)
- Long-distance I/O expansion for packaging machinery and logistics sorting lines
- Cabinet-split I/O for shipbuilding and construction machinery (marine classification certified)
- Production line retrofits: Deploy distributed remote outputs over existing Ethernet wiring to reduce control cabinet cabling
- モデルの選択 & 代替ソリューション
7.1 Direct Functionally Equivalent Replacement
Spring terminal variant: NZ2GF2S2-16R (fast wiring, screwdriver-free)
7.2 Alternatives for Higher Current Loads
For higher driving current requirements (transistor type): NZ2GF2B1-16T (DC24V transistor, 0.5A per point)
7.3 Legacy CC-Link Fieldbus Replacement (Non-Ethernet)
Legacy CC-Link (non-Gigabit IE) remote relay output module: AJ65SBTB2N-16R (incompatible fieldbus protocol, cannot be directly substituted)
- Critical Usage Precautions (Hard Restrictions)
- Relay outputs are prohibited from driving inductive loads exceeding 2A per point; surge suppressors must be paralleled with contactors and solenoid valves
- Industrial shielded Cat5e/Cat6 Ethernet cables are mandatory for fieldbus daisy-chaining; single link total length ≤ 100m
- An RC snubber circuit is recommended across contacts for AC inductive loads to extend relay service life
- The module only accepts DC24V main power supply; load voltage on the I/O side is independent and shall not share ground with the module power supply
- iQ-R series master stations are mandatory for synchronous motion control applications; Q series does not support fieldbus synchronization
Full Application Scenarios of Mitsubishi NZ2GF2B2-16R
Core Applicability Preconditions
This module features 16-point passive dry relay contact outputs, rated 2A per channel at AC240V/DC24V. As a CC-Link IE Field Gigabit Ethernet remote I/O module, it supports Ethernet daisy-chain cascading, universal AC/DC load compatibility and strong isolation between high/low voltage circuits. It is suitable for distributed control applications with scattered stations, long wiring distances, AC220V loads and infrequent switching cycles, and unsuitable for high-speed frequent switching loads.
- Logistics Conveyance & Sorting Automation (Most Common Application)
適用機器
ベルトコンベア, ローラー選別ライン, warehouse WCS systems, diverting/merging transfer machines, エレベーター, parcel scanning sorting stations
Controlled Loads
- AC220V pneumatic solenoid valves (diverter baffles, lifting cylinders, pushers)
- On-site station indicator lamps, fault alarm buzzers, 3-tier tower lights
- Small conveyor motor contactors, turnout reversing valves
選択のメリット
Production line stations are dispersed while the main control cabinet is centralized. Remote I/O modules connected via Ethernet replace numerous multi-core cables. One NZ2GF2B2-16R deployed per sorting station covers all cylinder and lamp outputs, drastically cutting cabling costs.
- Packaging Machinery Industry
適用機器
Vertical/horizontal packaging machines, blow molding machines, filling lines, ラベル貼り機, シール機, carton strapping machines, food dispensing production lines
Controlled Loads
- AC220V pneumatic actuation solenoid valves, heat-sealing heating relays
- Feed gates, cutter cylinders, pressing mechanisms
- Equipment status indicator lamps, audio-visual alarms, reject devices
選択のメリット
Filling and packaging workshops feature dust and humidity. Relay contacts provide superior high-voltage isolation and anti-interference performance compared to transistor outputs. CC-Link IE Gigabit communication delivers stable synchronization with zero delay for multi-station linkage.
- Automotive Manufacturing Lines (Welding / Coating / Final Assembly)
Applicable Stations
Body welding fixtures, coating drying lines, door assembly stations, component loading/unloading tooling, auxiliary I/O for robot peripherals
Controlled Loads
- AC220V clamping solenoid valves and positioning cylinders for welding fixtures
- Coating air dampers, drying oven damper actuators, spray valves
- Station safety indicator lamps, fault alarms, workpiece ejection mechanisms
Additional Compatibility Benefits
The module holds full marine certifications (LR/DNV/ABS) plus CE/UL approvals, meeting compliance standards for export automotive equipment. TSN-supported fieldbus enables synchronized linkage with robot servos when paired with iQ-R motion PLCs.
- 工作機械 & Metalworking Equipment
適用機器
CNC旋盤, マシニングセンター, グラインダー, スタンピングプレス, sheet metal bending machines, automated material warehouses
Controlled Loads
- Lubrication pump and cooling water pump contactors (AC220V)
- Pneumatic fixtures, door switch cylinders, chip removal solenoid valves
- Machine operation panel indicator lamps, alarm horns, tool magazine locking mechanisms
使用上の注意
Machine tools generate heavy electromagnetic interference. Relay isolation prevents high voltage from leaking into the PLC. Remote sub-distribution boxes installed near machine tools reduce wiring routed from the main cabinet.
- 食べ物, 飲料 & Pharmaceutical Production Lines
適用機器
Beverage filling lines, sterilization tunnels, pastry baking lines, pharmaceutical dispensing equipment, cleanroom conveyors
Controlled Loads
- Cleanroom pneumatic valves, filling head cylinders, bottle positioning mechanisms
- Cleaning spray solenoid valves, hot air circulation fan starters
- Cleanroom status lamps, production line emergency stop alarm outputs
環境適合性
Wide operating temperature range of 0~55°C with non-condensing resistance suits high-temperature sterilization zones and low-temperature cold storage dispensing stations. Screw terminals resist oil contamination and simplify cleaning & メンテナンス.
- ゴム, Plastic Extrusion & Injection Molding Equipment
適用機器
Automated pick-and-place robots for injection molding machines, extrusion lines, rubber vulcanization lines, pelletizers
Controlled Loads
- Mold clamping solenoid valves, ejector cylinders, feed gate reversing valves
- Temperature control fans, barrel auxiliary heater contactors
- Robot safety warning lamps, fault audio-visual alarms
- 海洋 & Port Maritime Equipment (Unique Certified Application)
Fully certified by marine classification societies, the module is engineered for distributed control on ship decks and in cargo holds:
- Cargo hold valve control, ventilation fan startup/shutdown
- Auxiliary cylinders and status indicator lamps for deck loading equipment
- Remote output control for sub-control boxes of port quay cranes and container gantry cranes
アドバンテージ
Marine systems feature mixed AC220V/DC24V power supplies. Passive relays are non-polarized and compatible with complex onboard power distribution systems.
- 空調設備, 水処理 & Environmental Complete Equipment
適用機器
Wastewater treatment control cabinets, waste gas treatment units, central air conditioning units, activated carbon waste gas adsorption towers
Controlled Loads
- Inlet/outlet electric valves, aeration fan contactors
- Dosing pumps, drain solenoid valves, dust removal dampers
- System fault alarms, running status indicator lamps
Application Feature
Equipment is located far from central control PLCs; discrete unit layout enables simple daisy-chain Ethernet wiring.
- Small Custom Non-Standard Automation Equipment
Test fixtures, assembly tooling, battery inspection equipment, electronic component sorting machines:
Drives small DC24V cylinders and fixture clamping valves
Station indicator lamps and defective product ejection solenoid valves
Ideal for low-volume multi-station tooling; 16 output points fully cover all actuators on a single fixture.
Unsuitable Application Scenarios (Model Selection Pitfall Avoidance)
- High-frequency switching loads (multiple on/off cycles per second): Mechanical relay contacts suffer short service life; select transistor output module NZ2GF2B1-16T instead
- Pure DC24V high-speed servo and fast cylinder control
- Emergency stop safety circuits and forced safety door cutoffs (special safety relay modules required)
- Single-channel loads exceeding 2A, or unprotected large inductive loads without surge suppression circuits
Core Selection Judgment Mnemonic
Scattered field layout, long-distance wiring, AC220V solenoid/contactor driving demand, low switching frequency → Prioritize NZ2GF2B2-16R
Centralized control cabinet layout, frequent cylinder actuation, DC24V-only loads → Select transistor output modules
コンタクタ,サーキットブレーカー,ソーラーインバーター,電気メーター,太陽電池